IP66 IP67 IP68 KEY FEATURES DESCRIPTION MARKET SEGMENTS AND APPLICATIONS. UV Resistant I/O Cabling

Similar documents
Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

MAP110 AC-DC Series Data Sheet

Indoor Linear 80W Driver SI-C215280N2KR

SPECIFICATION ESD FSP500-80MPD. Released Date:2015/07/27-14:41:38

Electrical Specifications

Engineering Design Assurance Test Report ( Dual & Triple ) MODEL: SPS-100P-D2 V1 5 V 12 Amax

ODW-621. RS-232 Point-to-point applications

Fibre Optic Modem ODW-622

LONWORKS Fibre Optic Converter

Fibre Optic Modem ODW-611

02/11/2015

DPS-250AB-18 E. 電氣規格 (Electrical Specification) REV. Description Date DESCRIPTION : MODEL NO. : Date Drawn Desing(EE) Design(ME) DOCUMENT NO. : REV.

POWER. DA10-M Series. 10 Watts. Data Sheet. Total Power: 10 Watts Input Voltage: Vac # of Outputs: Single, 5 Volts SPECIAL FEATURES

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

Fibre optic router for TP/FT-10 LRW-112PP

LONWORKS Fibre Optic Router

American Power Design, Inc.

LED Driver Linear / area dimming industry. Driver LC 200W 1050mA UNV ADV IND ADVANCED series

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

R&S ZN-Z85 Switch Matrix Specifications

Rack mounted telephone- and leased line modem for industrial applications

NI PXI/PXIe-2543 Specifications

Digital Input Modules for Compact FieldPoint

R&S ZN-Z154 Calibration Unit Specifications

Agilent 87405C 100 MHz to 18 GHz Preamplifier

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

R&S RT-Zxx High-Bandwidth Probes Specifications

LED Driver Compact fixed output

Product Range Power Supplies

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

POWER. DS800SL Series. 800 Watts Bulk Front End. Electrical Specifications. Data Sheet. Total Output Power: 800 Watts +5.

OT 100/ /700 P5

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

LED Driver Compact dimming

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

LED MODULES READYLINE DL

LED Driver Compact fixed output

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

LED Driver Linear / area fixed output

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Process Transmitter RMA 422

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

Electrical Specifications. 12 ms minimum for main O/P 20 ms minimum for standby. 80 ± 2.5 Vac. Overvoltage lockout

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Dimmers SЕRIES. Kitchen light control. Bedroom light control. Living room light control

Specifications. Reference Documentation. Performance Conditions

Obsolete Product(s) - Obsolete Product(s)

15 Series - Dimmer

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

LED control gear Compact fixed output

Model Number Structure

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Electrical Specifications. Input range Vac (Operating) 115/230 Vac (Nominal) TERMINAL BLOCK Frequency Hz, Nominal 50/60

TOSHIBA Industrial Magnetron E3328

Gamma instabus. Technical product information

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Renewable Energy Test and Measurement Robotics Wireless Communication Process Control

FLIR CM82: 600 Amp Power Clamp Meter with VFD Mode

LED Driver Compact fixed output

Datasheet - SRB301LC 24VAC/DC

Catalogue Ignitors and power switches for HID

KRF EMC Filters Installation, Operation and Maintenance Manual

ADE-R3GLH+ CONVERSION LOSS 50. ISOLATION (db) 10 LO= +7 dbm LO= +10 dbm LO=+13 dbm FREQUENCY (MHz) RF VSWR

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

IFM65UG OPS-COMPLIANT 16/7 400 NITS ULTRA HD INTERACTIVE FLAT PANEL DISPLAY

Datasheet - SRB-E-201ST

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

R&S ZVA110 Vector Network Analyzer Specifications

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Agilent N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz

STM49UG02 49 SOC BASED/OPS COMPLIANT 16/7 FULL HD DIGITAL SIGNAGE DISPLAY

PRODUCT SPECIFICATION Date: VESTEL

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

PRODUCT SPECIFICATION Date: VESTEL

Process transmitter RMA422

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

OPTOTRONIC Intelligent

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

LAVI-U252VH+ Performance Charts. LO=+18dBm LO=+21dBm LO=+24dBm. LO=+18dBm LO=+21dBm LO=+24dBm. LO=+18dBm LO=+21dBm LO=+24dBm

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Linear flow controls VFC Linear flow controls with actuator IFC

High performance circuit breakers

Filters for Power Lines (Low Leakage Current)

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

R&S HF907DC SHF Downconverter Specifications

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

R&S BBL200 Broadband Amplifier Specifications

Transcription:

SELED IP66/67/68, 600 W CDC, COMPCT, EFFICIENT, POWER SUPPLY KEY FETURES Sealed enclosure, IP66/67/68 Ingress Protection grade High efficiency (94% from 50% to 100% load) Low standby power consumption (< 0.35 W) Universal input voltage range (85 305 V C) Input inrush current limiting (<30 ) 800 W peak power (up to 10 s) Single 24, 48 V DC voltages ctive PFC, EN6100032 compliant (Class C, >25% load) Low earth leakage current (typ. <400 µ, 264V C, 60 Hz) Over temperature, OV, OC and SC protections. Stand by +5 V, 1.5 output. Remote On / Off signal IT approval to IEC/EN 609501 LED lighting safety approval to UL8750 Package ingress protection grade IP66, IP67, IP68 UV resistant input / output cables RoHS 2 compliant (Directive 2011/65/EU) INDUSTRIL TELECOM LED LIGHTING LED VIDEO WLL DISPLY IP66 IP67 IP68 UV Resistant I/O Cabling DESCRIPTION The DDP600 SC Series of industrial grade CDC power supplies provides the compact form factor, ingress protection index and high efficiency that the marketplace demands. It provides a steady 600 W of regulated DC power through the full 85 to 305 V C input range, all in a 4.92 X 9.86 X 2.36 form factor. The DDP600 SC series is available in an aluminium extruded chassis having fins for an optimal heat dispersion via natural convection. Being its PW assembling full potted within the enclosure, it offers a base plate that, once installed in contact with a system metallic frame, can be an effective path to dispel heat also through conduction helping thermal management. The input / output connections are by flying wires fixed to the chassis through water tight glands which combined with the sealed enclosure give the power supply an IP66/67/68 ingress protection grade (IP68 characterized as 1 m depth for 40 days). By converting energy at up to 94% efficiency, the DDP600 SC series generates less heat, facilitating optimal thermal management in space constrained environments, resulting in very high reliability. The DDP600 SC standard variant comes in a 24 and 48 V DC single output voltages (28, 36, and 52 V DC can be developed upon project assessment). The option variant (S) offers in addition, a +5 V DC standby output and the following control signals: +/ remote sense, remote On/Off (PS_Inhibit), power good (PS_Ok), Ishare (ISHRE1+V_SLOGIC). The power unit can be operated in a 30 to 70 C ambient temperature being the output power derated above certain limits depending on the input C. It provides UV resistant Input / Output cabling. Protection features include High Breaking capacity fuses on both C lines, input under voltage lockout (IUV), output overcurrent (OC), output shortcircuit (SC), output overvoltage (OV) and overtemperature (OT). The DDP600 SC series comply with the 2 nd edition of the IEC609501 standard for IT equipment and UL8750 standard for LED lighting applications. The DDP600 SC series meets the EN 55011, EN55032, EMC limits of Class B for conducted and radiated emissions as well as the IEC/EN610003, for harmonic and flicker, and IEC/EN 6100062, EN 55024 for EMC immunity standards. MRKET SEGMENTS ND PPLICTIONS Video Wall Display and SSL Lighting Industrial Process Control and utomation Telecommunications / Broadcasting Harsh environment supply www.efore.com Page 1

SELED IP66/67/68, 600 W CDC, COMPCT, EFFICIENT, POWER SUPPLY MODEL CODING ND OUTPUT RTINGS Model Grade and Output Power Output Voltages Packages ITE: DDP600 24 V DC: US24 28 V DC: US28 36 V DC: US36 48 V DC: US48 52 V DC: US52 Sealed Chassis: SC Standard Signals: S Model Code V1 Nominal [VDC] DDP600US24SC (S) 24 25 16.6 1.5 1.5 DDP600US28SC (S) 28 21.4 15 1.5 1.5 DDP600US36SC (S) 36 16.7 11.7 1.5 1.5 DDP600US48SC (S) 48 12.5 8.8 1.5 1.5 DDP600US52SC (S) 52 11.5 8 1.5 1.5 (*) Rated currents and combined power are referred to 55 C ambient and VC 180 VRMS. OUTPUT DERTING CURVES I1 ISTBY Max Combined Rated (*) Rated (*) Cooling Output Power (*) [] [] [W] [LFM] 55 C 70 C 55 C 70 C 55 C 70 C 600 400 600 470 600 470 600 425 600 470 The above derating curves are effective regardless mounting orientation www.efore.com Page 2

SELED IP66/67/68, 600 W CDC, COMPCT, EFFICIENT, POWER SUPPLY INPUT SPECIFICTIONS Specification Test Conditions / Notes Min. Nominal Max. Units C Input Voltage PS starts and operates at 85 V C at all load conditions 85 100277 305 V RMS DC Input Voltage 170 300 V DC Input Frequency Input Current Inrush Current Fusing 440 Hz with reduced PFC and output power rating Consult factory for details. RMS at 180 V C, maximum load, 50 / 60 Hz RMS at 85 V C, maximum load, 50 / 60 Hz Cold start, 25 C ambient, full load High breaking, 10, 250V on each C lines. 115 V C 230 V C 47 50/60 440 Hz 4.0 8.5 20 30 10 Efficiency t 115 V C, 20% rated load 50% rated load 100% rated load t 230 / 277 V C, 20% rated load 50% rated load 100% rated load Input Power Consumption Power on, 115 V C, no load Power on, 230 V C, no load Stand by, 115, 230 V C, no load Power Factor From 50 to 100% of rated load, 230, 115 V C, 50 / 60 Hz input voltages. THDi From 50 to 100% rated load, 115, 230, 277 V C 50 / 60 Hz. Harmonic Current Fluctuations and Flicker Earth Leakage Current Complies with EN 6100032 at 230 V C, 50/60 Hz, Class, D. Complies with EN 6100032 Class C at 230 V C, 50/60 Hz, >150 W load. Complies with EN 6100033 at nominal voltages and full load. Normal conditions 115 V RMS, 60 Hz 230 V RMS, 50 Hz 264 V RMS, 60 Hz 277 V RMS, 60 Hz (worst case) 89 93 92 90 94 94 5 4 0.35 0.90 % W 20 % 170 290 460 490 µ www.efore.com Page 3

SELED IP66/67/68, 600 W CDC, COMPCT, EFFICIENT, POWER SUPPLY OUTPUT SPECIFICTIONS Specification Test Conditions / Notes Min. Nom. Max. Units V1 Output Voltages ±0.5% set point accuracy RS+ closed on +V1, RS closed on V1 RTN, at 20% load on option variant (S). V V1 Output Power Rating cooling 600 (Refer to the derating curves below) W Peak (less than 10 s, after P_OK high) 800 5V SB Output Voltage ±3% set point accuracy, 20% load. 5 V 5V SB Output Current 1.5 V1 Voltage djustment Range Factory calibration upon customer request ±5 %V1 V1 LoadLineCross Regulation V C: 85 305 V RMS ; I1: 0 100% ±2 %V1 5V SB LoadLineCross regulation V C: 85 305 V RMS ; I 5SB: 0 100% ±5 %5V SB V1 Line Regulation V C: 85 305 V RMS ±0.1 %V1 Transient Response: V1, 5V SB Voltage Deviation V1 Ripple and Noise 25% load changes at 1 /µs 24V at 1000 µf load / I OUT> 2.5 28V at 1000 µf load / I OUT> 2.5 36V at 680 µf load / I OUT> 1.9 48V at 560 µf load / I OUT> 1.25 52V at 560 µf load / I OUT> 1.25 5V SB at 560 µf load / I OUT> 0.1 Rated load, Peaktopeak, 20 MHz BW. (100 nf ceramic, 10 µf tantalum at load) 24 28 36 48 52 ±5 %V1 %5V SB 1 %V1 V1 Startup Rise Time 85<V IN<305, any load conditions. 10 100 ms Startup Delay V1 in regulation after deasserting PS_Inhibit V1 in regulation after C is applied (worst case: 85 V C) 5V SB in regulation after C is applied (worst case: 85 V C) Turnon Overshoot 10 %V1 10 %V SB V1 Holdup Time t nominal V IN, full load 16 ms Minimum Load V1 and 5V SB 0 Maximum Load Capacitance V1 Current Sharing ccuracy V1: 24 V DC V1: 28 V DC V1: 36 V DC V1: 48 V DC V1: 52 V DC Two units in parallel at I1 rated load. VSLogic and IShare signals connected together. RS +, RS signals connected together and to the load. 450 2050 1500 16000 15000 12000 8000 7000 ms µf 45.5 54.5 %I1 www.efore.com Page 4

SELED IP66/67/68, 600 W CDC, COMPCT, EFFICIENT, POWER SUPPLY SIGNLS / CONTROLS ND TIMING Signal Notes Min Typ. Max Unit PS_Inhibit ctive low. Input low voltage 0 1.5 V Input high voltage (I IN= 300 µ) 3.5 5.5 V V1 disabled when PS_Inhibit is pulled low 5V SB not affected by PS_Inhibit V1 enabled when PS_Inhibit is floating or high P_OK* Logic level low (<10 m sinking) 0.7 V Logic level high (100 µ sourcing) 2.4 5.5 V Low to high time after V1 in regulation 40 350 ms Power down warning time 1 ms 5V SB Output ctive and in regulation after a 85<V C<264 is applied 1500 ms 5V SB not affected by PS_Inhibit * When V1 is On, a P_OK low may indicates V1 under voltage condition. When two MDP600 operate in parallel, P_OK low in one unit indicates that it is not sharing the expected amount of current (current sharing fault). 10 kω internal pull up to 5VSB is used; do not add any other external pull up. bove waveforms are expected with C Input ON/OFF: 5VSB On V1 On 250 ms T1 550 ms V1 rise time 10 ms T2 100 ms 5VSB rise time 3 ms T10 40 ms V1 On POWER_OK delay 200 ms T3 350 ms Power down warning T4 1 ms V1 Off 5VSB Off T5 0.5 s (V1 load > 25 W) C Off POWER_OK low T6 15 ms C_On 5VSB turn on time T7 1.5 s bove waveforms are expected with PS_Inhibit Signal On/Off state change: V1 rise time 10 ms T2 100 ms V1 On POWER_OK delay 200 ms T3 350 ms Power down warning T4 1 ms PS_Inhibit POWER_OK low timing T8 2 ms PS_Inhibit V1 On delay T9 450 ms www.efore.com Page 5

SELED IP66/67/68, 600 W CDC, COMPCT, EFFICIENT, POWER SUPPLY PROTECTION FETURES Specification Test Conditions / Notes Min. Nominal Max. Units Input Under Voltage utorecovering 58 65 75 VC Input Fuse High breaking, 10, 250V on L and L1. 10 Over Current Short Circuit Over Voltage t nominal input voltages V1: Hiccup mode, autorecovering (>10 s) V1: Hiccup mode, autorecovering (<10 s) 5VSB: Hiccup mode, autorecovering: t nominal input voltages V1: Hiccup mode, autorecovering. 5VSB: Hiccup mode, autorecovering. V1, Power shut down, latch off. 5VSB, Hiccup mode, autorecovering. Shut down, latch off. 108 135 1.6 132 163 3.6 Over Temperature (on primary stage) C Over Temperature Hiccup mode, autorecovering. (on secondary side) C Isolation: PrimarytoSecondary Reinforced 5660 VDC 4000 VC Isolation: InputtoEarth Basic 2121 VDC Production tested at 2121 VDC 1500 VC Isolation: V1to5VSB Basic 100 VC Isolation: OutputtoEarth Basic 1500 VC Equipment Protection Class Class I 120 145 150 %I1Rated %I1Rated %VNOM ENVIRONMENTL SPECIFICTIONS Specification Test Conditions / Notes Min Nominal Max Units Operating Temperature Range No derating up to 55 C, at 180 VC 30 55 C Operating Temperature Range with See derating curves and conditions in the Output Derating Specifications section 70 C Storage Temperature 40 85 C Humidity RH, Noncondensing Operating. 90 % Nonoperating 95 % Operating ltitude 5000 m Shock EN 60068227 Operating: Half sine, 30 g, 18 ms, 3 axes, 6x each (3 positive and 3 negative). NonOperating: Half sine, 50 g, 11 ms, 3 axes, 6x each (3 positive and 3 negative). Vibration EN 60068264 Operating: Sine,10 500 Hz, 1 g, 3 axes, 1 oct/min., 60 min. Random, 5 500 Hz, 0.02 g 2 /Hz, 1 grms, 3 axes, 30 min. NonOperating: 5 500 Hz, 2.46 grms (0.0122 g 2 /Hz), 3 axes, 30 min. MTBF Full Load, 40 C ambient 80% Duty cycle, Telcordia SR332 Issue 2 200000 Hours Useful Life Worst nominal VIN, 80% load, 40 C ambient 10 Years www.efore.com Page 6

ELECTROMGNETIC COMPTIBILITY (EMC) EMISSIONS SELED IP66/67/68, 600 W CDC, COMPCT, EFFICIENT, POWER SUPPLY Phenomenon Conditions / Notes Standard Equipment/Performance Class Conducted 115, 230, 277 V RMS. Maximum load. EN 55032 (ITE) EN 55011 (ISM) FCC Part 15 B Radiated The S variant compliance to the Class B is EN 55032 (ITE) conditioned by the use of a common EN 55011 (ISM) ground plane between the power supply FCC Part 15 and its load B Line Voltage Fluctuation t 20%, 50% and 100% maximum load. EN 6100033 and Flicker Harmonic Current Emission Nominal input voltages 230 V C input voltage, 50 / 60 Hz 230 V C 50 / 60 Hz, >150 W load EN 6100032 EN 6100032, D C ELECTROMGNETIC COMPTIBILITY (EMC) IMMUNITY Phenomenon Conditions / Notes Standard Test Level Criteria Reference standards for ITE Reference standard for Industrial/IMS equipment EN 55024 EN 6100062 ESD 15 kv air discharge, 8 kv contact, at any point of the system. EN 6100042 4 Radiated Field 10 V/m, 801000 MHz, 1 KHz, 80% M. EN 6100043 3 Electric Fast Transient ±2 kv on C power port EN 6100044 3 Surge ±2 kv line to line; ± 4 kv line to earth on C power port EN 6100045 4 Conducted RF Immunity 10 V RMS, 0,1580 MHz, 1 khz, 80% M EN 6100046 3 Dips and Interruptions 200 277 V C: Dropout to 0% for 10 ms Dip to 40% for 5 cycles (100 ms) Dip to 70% for 25 cycles (500 ms) Dropout to 0% for 5 s EN61000411 EN61000411 EN61000411 EN61000411 B 100 127 V C: Dropout to 0% for 10 ms Dip to 40% for 5 cycles (100 ms) Dip to 70% for 25 cycles (500 ms) Dropout to 0% for 5 s EN 61000411 EN 61000411 EN 61000411 EN 61000411 (derate to 150 W) (derate to 400 W) B SFETY GENCIESPPROVLS Certification Body Safety Standards and file numbers Category CS/UL CS C22.2 No. 609501, UL 609501; 2007, 2 nd edition +1 + 2 Information Technology Equipment IEC IECEE CB Certification CE UL8750, CS C22.2 No 250.13 IEC/EN 609501 2 nd edition + 1 + 2 Directive 2014/35/EU: Electrical Safety: Low Voltage electrical equipment (LVD) Directive 2014/30/EU: Electromagnetic Compatibility (EMC) Directive 2011/65/EU: RoHS 2 Designed to meet IEC/EN/UL/CS 610101 2 nd edition Lighting Information Technology Equip. Information Technology Equipment www.efore.com Page 7

SELED IP66/67/68, 600 W CDC, COMPCT, EFFICIENT, POWER SUPPLY OUTLINE DRWING ND CONNECTIONS Overall dimensions: (125.0 X 250.5 X 60.0) mm; (4.92 X 9.86 X 2.36) in Weight: 2770 g; 6.11 lb (Standard); 2850 g; 6.28 lb (Signals S) Input cable Output Cable 24, 28V Signal Cable 36, 48, 52V 24, 28V 36, 48, 52V Specifications appearing in EFORE s catalogues and brochures as well as any oral statements are not binding. ll descriptions, drawings and other particulars (including dimensions, materials and performance data) given by EFORE are as accurate as possible but, being given for general information, and are not binding on EFORE. EFORE makes thus no representation or warranty as to the accuracy of such material. We assume no liability other than as agreed in the terms of the individual contracts and we reserve the right to make technical modifications in the course of our product development. Our product information solely describes our goods and services and is in no way to be construed or interpreted as a quality or condition guarantee. The aforesaid shall not relieve the customer of its obligation to verify the suitability of our Products for the use or application intended by the purchaser. Customers are responsible for their products and applications. EFORE assumes no liability from the use of its products outside of specifications. No license is granted to any intellectual property rights by this document. www.efore.com Page 8