Contactor Monitoring Relay CMD Cost-Effective Solution for Safe Machines

Similar documents
Safe Switching with Safe Contactors

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Multi-functional safety relay modules PROTECT SRB-E

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

High performance circuit breakers

Clearly BETTER! The new signal towers: SL7 SL4

Intelligent compressor solutions. EFC, EFCe Systems Electronic Frequency Control EFC. EFCe

Series CT7N Bimetallic Overload Relays

Type: DILM12 10(24VDC) Article No.:

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

AC1036. Definite Purpose Contactors

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Combination Motor Controllers. XT IEC Power Control

Type: DILM25 10(24V50HZ) Article No.:

Selection guide siemens.com/sirius-modular-system

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

Failure Modes, Effects and Diagnostic Analysis

english SGC inverter series hf transformer input voltage up to 800 V touch screen built-in data loggers

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

PRINCIPLES AND APPLICATIONS

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

Ordering details. Approval. Classification

Datasheet - SRB301LC 24VAC/DC

HS-509 VIBRATION TRIP MODULE

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

Installation Operation Maintenance

Function Manual SIMATIC HMI TP900. Operator Panel.

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

Kuhnke Technical Data. Contact Details

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

OT 100/ /700 P5

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

MICROMASTER Encoder Module

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

LED Driver Linear / area fixed output

PRELIMINARY Sunny Boy 240-US

Datasheet - SRB-E-201ST

SUNNY TRIPOWER 8000TL / 10000TL / 12000TL / 15000TL / 17000TL

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Product Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)

HYL-035D0850G103. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Circuit-Breakers for Motor Protection Series 8523/8

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Inductive sensor BI1.5-EG08K-Y1

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

G1-M1 (Protection Relay)

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

XT IEC Power Control Combination Motor Controllers

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

SURGE PROTECTIVE DEVICES

and Refrigeration Institute). Hydraulic Elevator Wye-Delta Contactors

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

TeSys circuit-breakers

>Inductive. REFERENCE guide. Proximity

and Refrigeration Institute). CAQ7 Capacitor Switching Contactors

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

Features XT SC 012 B B A

Bulletin 190 IEC Modular Starter System

>Inductive and. REFERENCE guide. Capacitive Sensors

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

llen-bradley 194R-HM4-NFPA3

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Minicontactorrelay,2NO/2NC,DCoperated

GuardPLC Certified Function Blocks -- Basic Suite

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Arc Detector for Remote Detection of Dangerous Arcs on the DC Side of PV Plants

Contactors and Contactor Assemblies

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Model Number Structure

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

HARMONIZATION OF SYNOPTIC BLOCK DIAGRAMS ON THE CONTROL PANELS OF MV SWITCHGEAR AND CONTROLGEAR

Inductive sensor NI3-EG08K-Y1-H1341

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

Figure 1: Device components

Features XT SC 012 B B A

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Magnecraft Power Relays

Sales guideline for PROTECT SELECT Version 1.0 of

Bulletin 109 TABLE OF CONTENTS Bulletin 109 IEC Non-Reversing Starters. Enclosed Type Molded Plastic. Description Page Description Page

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

EB 3000 as of Version 1.7

Inductive sensor NI10-M18-Y1X-H1141

Transcription:

Contactor Monitoring Relay CMD Cost-Effective Solution for Safe Machines The complete range of contactors, efficient motor-starters and variable speed drives for the motor circuit. New simple to install solutions based on clever communication. Technical Paper Dipl.-Ing. Wolfgang Nitschky Contactors DIL Motor-protective circuit-breakers PKZ Motor starters MSC Soft starters DS 4 Frequency inverters DF, DV Rapid Link

The way to safe machines During the engineering design phase of a machine, every design engineer in addition to considering the functional aspects of the machine is confronted eventually with the issue of safety features, and is posed with the following question: How dangerous is the machine that they are designing? The potential dangers posed by the machine can be identified by a risk assessment. A portion of the danger can be suppressed by mechanical modifications or extensions (no sharp edges, bulkheads in front of moving parts, etc.). If an electrical control is engineered, safety tasks are shifted to the control. Typical safety tasks are the Emergency-Stop or monitoring of safety doors, contact mats or photoelectric barriers. The question of the reliability of the control during a malfunction should be considered in order to delegate the control of safety-relevant tasks to the control. The EN 954-1 The European standard EN 954-1 can easily claim to be simple to apply. Based on the simplicity of its fundamental design, the standard can be easily integrated and applied in the field of mechanical engineering. The classification in specific cases is not always easy, but the basic steps to be applied remain transparent in all cases. Using the tree structure (Figure 1) it is possible to appraise what can happen if the control fails. First of all the seriousness of the injury is assessed, followed by the time spent in the danger area and finally the perceptibility of the danger. The assessment results in the safety categories to which the control must comply. The safety categories are a measure of the reliability of the control during a malfunction. The fundamental difference between controls of safety category 1 or 2 to controls of categories 3 or 4 is that the controls in safety categories 1 and 2 may lose their safety function during a fault scenario. Controls of safety category 3 or 4 must maintain their safety function even in a fault scenario. Contactor control circuits conform to EN 954-1 If the electrical circuits for control of motors are now examined, the motors are switched by contactors. A typical contactor fault is welding of the contactor contacts. If the control voltage on the contactor coil is removed by an Emergency-Stop and there is a fault involving welded contactor contacts, further measures for maintaining the safety function in controls of safety category 3 or 4 must be provided. Generally, a connection of two contactors in series (Figure 2) is provided. With the rare exception that both contactors have not welded at the same time, the safety function is maintained as the second contactor will bring the drive which is the source of danger to a standstill. This expensive solution, which requires significantly more space in the control panel and additional time and expense for manufacturing the main wiring harness, is not always acceptable in the engineering design. This is where Moeller uses the CMD Contactor Monitoring Device. Not a second, expensive and large contactor to maintain the safety function, but rather a small attractively priced relay. This continuously compares the specified state of the contactor based on the control voltage with the actual state which is signalled with the assistance of an auxiliary contact. In a fault scenario, the CMD switches the B 1 2 3 4 Category in accordance with EN 954-1 Risk graph S1 P1 Starting point for risk assessment S2 F1 P2 Category selection P1 F2 P2 S Severity of injury S1 Slight injury S2 Serious irreversible injury to one or several persons, or death F Frequency and time of exposure to the hazard F1 Rarely to often and/or a short duration F2 Frequent to continuous and/ or a long duration Preferred category for reference points Possible categories which require additional measures, e.g. over-dimensioning Over-dimensioned categories for the risk concerned P Possibility of avoiding hazards P1 possible under specific conditions P2 Scarcely possible Figure 1: Risk assessment graph according to EN 954-1 2

Figure 2: Redundant power section upstream contactor or switch-disconnector off using the undervoltage coil. Enhancements of the EN 954-1 in the EN ISO 13849 The simple handling of the EN 954-1 described at the outset has the disadvantage that it fails to make any mention of the reliability of the control in the scheduled service life. This circumstance has lead to the EN 954-1 only being valid for a transitional period. The successor standard EN ISO 13849, has been expanded in some aspects and makes statements regarding the occurrence of malfunctions. PL Performance Level The assessment of the consequences of a control failure using a tree structure no longer results directly in a safety category, but rather in a Performance Level in accordance with the EN ISO 13489. This can result in PLs ranging from a to e (Figure 3). The PL reflects the level of danger that exists due to the failure of a control. On machines featuring a control of PL a, there is only a low level of danger, whereas machines with a control categorised as PL e are categorised as very dangerous The actual Performance Level that a control complies with no longer depends solely on the design of the control. Additionally, qualitative declarations regarding the service life and fault detection must also be considered. MTTF Mean time to failure The MTBF time (mean time between failure) is a measure of the reliability of a component or a control which has been in use for a long time with electronic components. As the electromechanical components of an assembly no longer function after the first fault, the MTTF time (mean time to failure) is taken into consideration here. It is a measure of how long the component or control will function reliably. As only the faults, which can cause dangerous failures need to be examined from the safety technology perspective, the MTTF d (Mean time to failure dangerous) is considered for assessment of the Performance Level. 3 years <= MTTF d < 10 years r low 10 years <= MTTF d < 30 years r medium 30 years <= MTTF d < 100 years r high DC Diagnostic Coverage The Diagnostic Coverage enables a quantitative statement with regard to detected faults. This involves the assumption principle that a control that detects a large number of faults is more reliable than a control that hardly detects any faults. DC < 60% r no error detection 60% DC < 90% r low error detection 90% DC < 99% r medium error detection 99% DC r high error detection Common cause failure In order to avoid a failure burst measures must be undertaken to avoid common cause failures. For this purpose, a range of measures is provided by the standard to assist the users. Interaction between PL, DC, MTTF d The Performance Level to which the control complies can be read off of a bar chart (Figure 4). Operating principle of the CMD The CMD relay has the task of monitoring the high-power contacts of the motor contactor for welding. For this purpose, the control voltage of the contactor coil is applied as the specified on the CMD. On the other side the actual state of the contactor is signalled via a reliable auxiliary N/C contact. The CMD compares the nominal and actual state. The undervoltage coil of the upstream circuit-breaker or switch-disconnector is supplied via a relay output. In the event of a fault the circuit-breaker / switchdisconnector is switched off via the Legend PL Performance Level 1 MTTF d every channel = low 2 MTTF d every channel = medium 3 MTTF d every channel = high Risk parameters S Severity of the injury S1 Slight (generally a reversible injury) S2 Severe (irreversible injury including death) F Frequency and/or exposure time to the hazardous condition F1 Seldom up to quite often and/or the exposure time is brief F2 Frequent up to continuous exposure to the hazardous condition P Possibility of avoiding the hazard or limiting the damage P1 Possible under certain conditions P2 Scarcely possible Legend 1 Starting point to the assessment of the risk reduction L Low contribution to risk reduction H High contribution to risk reduction PL r Required Performance Level Source: DIN EN ISO 13849-1 Figure 3: Risk assessment graph according to EN ISO 13489 DC avg low DC avg low DC avg medium DC avg medium DC avg none DC avg none DC avg High Figure 4: Performance Level Source: DIN EN ISO 13849-1 3

L1 L1 L01 L01 L2 L2 -F1 L3 L3 -Q1 -Q11 L1 L2 L3 1.13 I > I > I > T1 T2 T3 1 3 5 2 4 6 a -Q1 -S1 1.14 -K 21 22 -S2 13 14 -Q11 13 14 -Q11 21 22 -Q11 33 34 -S3 21 22 TEST b 13 14 PE -X1 U V W PE PE -Q11 A1 A2 -F2 CMD A1 A2 L S21 S22 S13 S14 S31 S32 -Q1 D1 D2 U < D2 -M1 M 3 L02 1 2 3 4 5 6 13 14 21 22 33 34 L02 Figure 5: Circuit diagram of direct-on-line starter with redundant shutdown undervoltage coil and the motor voltage source is switched off (Figure 5). The CMD in combination with the circuit-breaker / switch-disconnector complies with the demand for a redundant shutdown. Irrespective of the welded contactor fault, the control continues to maintain its safety function (Figure 6). Reliable signalling using auxiliary contacts 4 Figure 6: High level of reliability of the contactor monitoring relay The quality of the signal relating to the state of the power contacts is decisive in the described application. Welding of the power contacts must be reliably detected. The IEC EN 60947 standard for electrical low-voltage switchgear has defined the term mirror contacts for this purpose. A mirror contact on a contactor

Control voltage Type Article number 24 V DC CMD(24VDC) 106170 110 V/50 Hz, CMD(110-120VAC) 106171 120 V/60 Hz 230 V/50 Hz, 240 V/60 Hz CMD(220-240VAC) 106172 Most of the conventional safety-related control circuits operate at 24 VDC. However, with larger drive systems 230 V/50 Hz, 240 V/60 Hz are used and in American systems 110 V/50 Hz, 120 V/60 Hz are used. The variants thus cover the typical control voltages for contactor drives (Figure 8). Permissible combinations Figure 7: Contactor auxiliary contact with mirror contact is an auxiliary N/C contact that can only close if all power contacts have opened. All auxiliary N/C contacts on the threepole contactors DILM 7 to DILM 1600 and DILH 1400 to DILH 2000 and the four-pole contactors DILM P comply with the demands of a mirror contact (Figure 7). With the (high power) contact modules the side-mounted auxiliary contacts NHI2-11S-PKZ2 comply with the demands for a mirror contact. contact NHI2-11S-PKZ2, all the contact modules are positively-drive with respect to each other. CMD variants The supply voltage of the CMD must be identical to the control voltage of the contactor to be monitored. The CMD is available for different control voltage variants in order to cover the largest possible range of applications: In order to guarantee a reliable functioning of the combinations of circuitbreaker/switch-disconnectors, contactors and CMD, only defined components are approved for use. Other contactors featuring other switching times or undervoltage releases with other voltage levels can cause a loss of the safety function. Contactors The following contactors are approved for establishing safety relevant control sections: The contactor must feature an auxiliary N/C contact with mirror contact functions and a further auxiliary contact that As it is also possible that an auxiliary N/C contact can weld, monitoring is also necessary here. The IEC EN 60947 standard has also defined a solution for this situation. Mutual monitoring of auxiliary N/O contacts and auxiliary N/C contacts is possible with positively-driven contacts, as they may never by closed simultaneously. This is used for monitoring of mirror contacts. An additional auxiliary N/O contact which must be positively-driven to the mirror contact, is additionally monitored by the CMD. Welding of the auxiliary contact is thus detected which forces the drive to a standstill. In the Moeller contactor series, all auxiliary contacts of an auxiliary contact module comply with the demands of positive operation. Auxiliary N/O contacts are positively driven against auxiliary N/C contacts on the same auxiliary contact module. Even in the standard auxiliary Figure 8: Contactor monitoring relay CMD 5

Contactor type is positively-driven to the mirror contact (Figure 9). Circuit-breaker/switch-disconnector The CMD is approved with the following circuit-breakers / switch-disconnectors (Figure 10): Switch PKZ2 NZM1, N1 NZM2, N2 NZM3, N3 NZM4, N4 Control voltage CMD (24 VDC) DILM 7 to DILM 15 24 VDC DILM 17 to DILM 500 RDC24 SE1A-G-10-PKZ2, S-G-PKZ2 24 VDC CMD (110-120 VAC) DILM 7 to DILM 95 110 V 50 Hz, 120 V 60 Hz 110 V 50/60 Hz DILM 115 to DILM 170 RAC120 DILM 185 to DILM 1600 RA110, RA250 SE1A/..-PKZ2, S-PKZ2 110 V 50 Hz, 120 V 60 Hz 110 V 50/60 Hz CMD (220-240 VAC) DILM 7 to DILM 95 230 V 50 Hz, 240 V 60 Hz 220 V 50 Hz, 240 V 60 Hz 220 V 60 Hz 240 V 50 Hz 220 V 50/60 Hz 230 V 50/60 Hz DILM 115 to DILM 170 RAC240 DILM 185-S to DILM 500-S 220-240 V 50/60 Hz DILM 185 to DILM 1600 RA250, RAW250 DILH 1400 to DILH 2000 RAW250 SE1A/..-PKZ2, S-PKZ2 230 V 50 Hz, 240 V 60 Hz 220 V 50 Hz, 240 V 60 Hz 220 V 60 Hz 240 V 50 Hz 230 V 50/60 Hz Undervoltage release U-PKZ2(18VDC) NZM1-XUVL NZM2-XUV NZM3-XUV NZM4-XUV Safety-relevant observation of the CMD From the safety technology perspective a circuit consists of two parallel paths: The contactor The series connection of CMD and undervoltage release MTTF d of the circuit Die MTTF d Zeit wird für beide Pfade getrennt berechnet. For contactors the MTTF d time is dependent mainly on the switching conditions of the application. A contactor that switches once a day will achieve a significantly higher MTTF time than a contactor that must switch every 5 seconds (12 x 60 x 8 switching per day). Moeller cannot define fixed MTTF times for the observation as a result. Moeller provides the B10 d values for calculation of the MTTF d time of the application in question. In combination with the application data the MTTF values of the contactors can be calculated using formula 1: B10 d MTTF d = 0, 1 n op where n op : average count of annual switching The following table provides the B10 d values for calculation purposes with AC-3 applications at 400 V: Figure 9: Contactor with fitted auxiliary contacts Figure 10: Circuit-breaker with fitted undervoltage release 6

Contactor DILM 7 to DILM 12 DILM 15 DILM 17 to DILM 65 DILM 72 DILM 80 to DILM 150 DILM 170 DILM 185 to DILM 820 DILM 1000 to DILM 1600 B 10d value at 400 V AC-3 1.3 million switching 0.75 million switching 1.3 million switching 0.75 million switching 1.3 million switching 0.75 million switching 1.3 million switching 0.3 million switching The MTTF d time of the CMD relay is 125 years under the condition that a maximum switching frequency of n op = 350,400 switching / year is not exceeded. The B 10d values of the undervoltage release are: Undervoltage release PKZ 2 NZM 1, NZM 2 NZM 3 NZM 4 B 10d value 10,000 switching 10,000 switching 7,500 switching 5,000 switching Diagnostic coverage of the circuit The Diagnostic Coverage is also calculated separately for both branches. As the contactor is switched operationally and the state with each switch operation is checked by the auxiliary N/C contact with mirror contact, the error detection on the contactor is very high: DC contactor: = 99 % Performance Level of the circuit The parallel connection of the CMD and undervoltage release to a contactor complies with Performance Level PL=e. The calculation is subject to the following preconditions: Maximum of the contactor: 350,400 switching / year Maximum switching of the undervoltage release: 1095 switching / year In the calculation of the overall Performance Level for the control the upstream safety components must be considered. Overall, controls that comply with Performance Level d can be established in this way. Summary The CMD is used in safety-relevant current circuits. It monitors if the main contacts of the contactor have welded. If welding is detected, it switches off the supply of power to the application using the upstream circuit-breaker. Using the CMD, controls that comply with Performance Level d can be set up. In contrast to the contactor, the undervoltage release is a dormant component. The functional capability of the undervoltage release cannot be operationally tested. By additional testing of the circuit once a year a DC=90 % is achieved for the undervoltage release. The Diagnostic Coverage of the CMD DC = 90 % 7

Moeller addresses worldwide: www.moeller.net/address E-Mail: info@moeller.net Internet: www.moeller.net Issued by Moeller GmbH Hein-Moeller-Str. 7-11 D-53115 Bonn 2007 by Moeller GmbH Subject to alterations VER2100-961D ip Printed in Germany (11/07) Article No.: 113748 Xtra Combinations Xtra Combinations from Moeller offers a range of products and services, enabling the best possible combination options for switching, protection and control in power distribution and automation. Using Xtra Combinations enables you to find more efficient solutions for your tasks while optimising the economic viability of your machines and systems. It provides: flexibility and simplicity great system availability the highest level of safety All the products can be easily combined with one another mechanically, electrically and digitally, enabling you to arrive at flexible and stylish solutions tailored to your application quickly, efficiently and cost-effectively. The products are proven and of such excellent quality that they ensure a high level of operational continuity, allowing you to achieve optimum safety for your personnel, machinery, installations and buildings. Thanks to our state-of-the-art logistics operation, our comprehensive dealer network and our highly motivated service personnel in 80 countries around the world, you can count on Moeller and our products every time. Challenge us! We are looking forward to it!