Installation instructions Roxtec RM PE B

Similar documents
Installation instructions Roxtec RM ES B

Installation instructions Roxtec RM PE

Installation instructions Roxtec RM ES

Installation instructions Roxtec RM ES systems

Installation instructions Roxtec RM BG B systems

Installation instructions Roxtec RM BG systems

Installation instructions Roxtec CM PE systems

Installation instructions Roxtec CF 16 EMC and Roxtec CF 16 O EMC

Installation instructions Cable transit device Roxtec RS ES Ex

Installation instructions Roxtec RS ES Ex

Installation instructions Ex frames

3M Distribution Box (DDB)

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

2178-L/S Series Fiber Optic Splice Case with Gasket

Instructions. Cable with Armor F CAUTION. October Rev A

3M Better Buried Compound Compression Closure System

3M SLiC 530/533/733-2 Port 0.61 Cable Entry Bracket 3M SLiC 530/533/733-2 Port-MSM 0.61 Cable Entry Bracket

FOSC 450 C6 and D6 Closures

2178 Fiber Optic Splice Case and 2181 Cable Addition Kit

3M Fiber Optic Splice Closure 2178-XSB/XSB-FR & 2178-XLB/XLB-FR 3M Cable Addition Kit 2181-XB/XB-FR

3M Better Buried Closures

18mm ECAM Cable Entry Port

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR

3 SLiC Aerial Closure with Rubber End Seal

K & B Flame Retardant Building Riser Closures

Installation Instructions

3M Better Buried Closure (with 3M Scotchlok Shield Bond Connector 4462-FN and 3M High Gel Re-enterable Encapsulant 8882)

Medium Box for Cable Termination

3M Fiber Optic Splice Closure 2178-XL & 2178-XL/FR 3M Cable Addition Kit 2181-XL and 2181-XL/FR

3M Scotchcast Reenterable Signal and Control Cable Splicing Kits 78-R Series

3M Locator Plate N

3 Foam Sealed Closure 2" (50 mm) with Compound Compression

HSK Mine and Portable Cable Splice

FOSC-600 C and D I N S T A L L A T I O N I N S T R U C T I O N

3M Cold Shrink Foldback Splice Jacket Kit

3M Scotchcast Mine and Portable Cable Splice and Jacket Repair Kit M-40

FIST-MB2-S. FIST Medium Box for Cable Splicing Only. 4 Cable installation. 1 Introduction. Contents. 2 General. 5. Fiber routing to individual trays

27mm ECAM Double Cable Entry Port

Quante BPEO Splice-Protection Closure for Optical Fiber Cables. Features Advantages Benefits

3M Fiber Optic Splice Tray 2527 with 3M PLC Optical Splitter

SLiC Fiber Aerial Closure System

Scotch Heavy Duty Vinyl Electrical Tape 22

FIST-GCO2-OTIAN I N S T A L L A T I O N I N S T R U C T I O N

3M Cold Shrink Splice Kit QS-III 5515A

SPECIFICATION. Spec No : VSS-1402-CS603B

3M Cold Shrink Splice Kit QS-III 5416A

3M Fiber Closures BPEO

3M Fiber Optic Closure System LL

3M Scotchcast Flexible Power Cable Splice Kits 82-F Series

3M Cold Shrink Splice Kit QS-III 5514A

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

Cold Shrink Three-Conductor Splice Kit QS-III for use on Armor and Non-Armor Cables Instructions IEEE Std kv Class 250 kv BIL

2178 L/S Series Fiber Optic Splice Cases and Accessories

LCC (Little Coaxial Connector) Installation Instructions)

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN-4/0-500

3M Cold Shrink QS4 Integrated Splice Kit QS4-35TS

3M Super 23 Electrical Tape

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

3M No Polish Jacketed SC/APC Connector

Instruction Guide February 2017

3 Closure preparation 3.1 Work-stand 3.2. Opening FIST-GCOG2-Dx Preparing drop cable with micro-tubes

SLiC Fiber Aerial Closure 533 and 733

OPERATION AND MAINTENANCE MANUAL

F CAUTION. Jacketed Concentric Neutral (JCN) Cable. Concentric Neutral (CN) Cable. IEEE Std. No. 48 Class 1 Termination 15 kv Class 110 kv BIL

Solutions for Electronic Specialty Markets (ESM)

Cable installation guidelines

3M Coupling Tray FDTC-10S-COUPLINGTRAY

INSTALLATION INSTRUCTIONS

FOSC-450D. Fiber Optic Splice Closure. 1 Introduction. Content. 5 Cable termination. 6 Fiber routing. 2 General. 7 Installation of the gel block

MX-MOLDED READY VGA TO BNC CABLES MX-2076 MX MDR Electronics

ENGINEERING COMMITTEE

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

Backlight Replacement

VGA Extender over Single CAT 6 Cable with Audio Support. Model Extend both video and audio up to 1000 feet

Sections 1. Application Equipment 2. Cable Preparation 3. Assembly 4. Termination Procedure 5. Inspection 6. Repair 7.

3M Fiber Optic Splice Closure 2178-L/S Series with Gasket

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

3M 8900 Single-mode SC Crimplok Connector

REQUIRED TOOLS. Wire cutters Razor blade Soldering iron Pliers 11/16 Wrench for Tube 18mm Wrench for Ring

User Manual. Model 979T and 979R Digital Audio Converters

3M Sensored Termination (15 kv) QX-T15I-vi1-E

MX-MOLDED READY VGA CABLES MX-2074, 2075, 2079,(LOW AND MID) MX-2987,(HIGH END) MDR Electronics

KEL 24 Cable entry frames

Fiber Optic Splice Closure GPJ Instruction Manual

TFT-150R-G. Tape Shield Cable (page 2) Suggested Installation Equipment (not supplied with kit) Wire Shield Cable (page 7)

OFDC-B8-72. Outdoor fiber distribution closure. 6 Closing. Content 1 Introduction. 7 Re-entry. 2 Kit content. 3 Closure preparation

Rotor Blade Protection Kit 8999K11

RAIL D-SUB BACKSHELLS

3M Motor Lead Inline Splice 5331, 5332, 5333 & 5334

1672A. Product Description. Product Specifications. Technical Specifications. Conductor. APAC Standard. Bend Radius.

High Density Block BRCP. HD BRCP- 128/192/256 pair. Installation Instructions

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

MX-VGA CABLE MX-2107 AND MX MDR Electronics

3M Fiber Optic Wall Mount Enclosure 8430 Series

XS_-EU. M8 and M12 Sensor Connectors. Ordering Information

LGX Compatible (LSX) Connector Module) User Manual)

SPECIFICATION FIBER OPTIC SPLICE CLOSURE. Spec No : VSS-1007-BS403A-04A/SD. VSS-0107-BS403A-04A/SD R & D Center Manufacturing Division

DVDO VS4 HDMI Switch. User s Guide How to install, set up, and use your new DVDO product

imac Intel 20" EMC 2133 and 2210 LCD Backlights (CCFL) Replacement

Transcription:

Installation instructions Roxtec RM PE B Environmental side Termination/ interior side Pipe Cable screen/armor Layers Termination/ interior side Cable sheath Layers Environmental side Plastic film Conductive tape Integrated environmental sealing system for shielded applications. One side provides environmental protection and the other is for the termination. For use with armored/shielded cables. For approvals, see www.roxtec.com. Module sizing chart Module type For cable/pipe outer diameter a-b (mm) RM 15 PE B 3-11 RM 15w40 PE B 3.5-10.5 RM 20 PE B 4.0-14.5 RM 20w40 PE B 3.5-16.5 RM 30 PE B 10-25 RM 40 PE B 21.5-34.5 RM 40 10-32 PE B 9.5-32.5 RM 60 PE B 28-54 RM 60 24-54 PE B 24-54 RM 80 PE B 48-71 RM 90 PE B 48-71 RM 120 PE B 67.5-99 Note: The range of the modules indicates the smallest possible diameter of the exposed cable screen or pipe to the largest possible diameter of the cable sheath or pipe.

Components Roxtec PE B module Roxtec solid PE B module Roxtec Wedge Roxtec Stayplate Roxtec Wedge Clip Roxtec Lubricant Recommended tools (Not included) 13 mm spanner Screwdriver Heat gun Cable stripper Pre-compression tools EMC marking tool Protective goggles Continuity tester Stayplate Clip

Installation 1 2 3 4 Clean the frame from dirt, paint etc. to secure good electrical conductivity. For pipes: continue from step 6. Hold the cable in its final position and mark where the cable sheath is to be removed using the guide. Cut and remove the outer sheath to expose the shield or armor of the cable. Remove the outer sheath and any plastic foil. Make sure the cable screen/armor/pipe is clean and conductive. 5 Optional: Attach shrink tubing to cable end to prevent fraying. 6 w Measure your frame height (H) and check the corresponding packing height (h) in the table. Consider your packing height when inserting the modules. h H Packing space Frame size Frame height (H) Frame width (w) Packing height (h) 1 101 60 60 2 101 120 60 3 160 60 120 4 160 120 120 5 218 60 180 6 218 120 180 7 278 60 240 8 278 120 240 7 8 9 10 Lift the conductive tape. Remove the protection paper from the modules and fold back the tape. Note: This must also be done on all spare modules. Adapt layers on the environmental protection side to the cable sheath. The number of layers may not differ by more than one between the halves. Adapt layers on the termination side to the cable screen/armor. The number of layers may not differ by more than one between the halves. 11 0.1 1.0 mm 0.004 0.039" Test with a cable. Achieve a gap of 0.1-1.0 mm between the module halves. If not, repeat 9-10. The halves may not differ by more than one layer. Make sure the screen/armor is in good contact with the tape.

12 13 14 15 Fold the adhesive tape tightly inside the module half from one side. Separate the plastic film from the conductive tape and fold it to the side. Fold the tape on the other side tightly inside the module half. Fold the plastic film back inside the module half. 16 17 18 19 Plastic film Conductive tape Lubricate all modules used for cables/pipes with Roxtec Lubricant on inside and outside rubber surfaces only. Do not lubricate the plastic film. Lubricate all spare modules for the frame thoroughly, both the inside and the outside surfaces. Do not remove the core. Lubricate solid modules on the sealing surfaces only. Remove the plastic film! Keep the tape clean. 20 21 22 23a Note: Plastic must be removed also on solid and spare modules. Lubricate the whole frame and especially its corners. Lubricate the area that will be in contact with the tape sparsely. Place cables, according to your transit plan, in the module halves. Place corresponding module halves directly on top. 23b 24 25 26 Stayplate Module Module Conductive tape For pass-through cables, make sure the braid/armor is visible on the termination side. Insert a stayplate on top of every finished row of modules. Make sure the stayplate is clean. To simplify installation, the use of an optional pre-compression tool on every second module row is recommended. Roxtec installation tools are available. Ensure that the modules are secured within the stayplate edges.

27 28 2x Before inserting the final row of modules, insert two stayplates. 31 Separate the two stayplates and insert the final row of modules between the stayplates. Avoid damaging the conductive tape. 32 29 30 Drop the upper stayplate on top of the modules. 33 Stop Frame flange If there is not enough room for the wedge, insert the optional Roxtec pre-compression tool and precompress. 34 Wedge Compressed Uncompressed Ensure that the wedge is fully uncompressed by untightening the screws of the wedge before inserting it. 35 Stayplate Lubricate both short sides of the wedge thoroughly. 36 Orientate the wedge so the face marked Stayplate this side faces a stayplate. Insert the wedge to the stop flange. Ensure that the wedge is accommodated and secured by the stayplate. 37 Recommended wedge positions. 38 25 mm Tighten the screws alternately until full mechanical stop, approx 20 full revolutions per screw. Do not exceed 20 Nm (15 ft.lb.). Earth continuity test Optional: Verify earth continuity from each cable screen/armor to earth. Use a suitable instrument. 25 mm of the screws shall be exposed. Attach the wedge clip to the wedge screws to complete the installation.

Disassembly 1 2 3 Wedge Remove the wedge clip from the wedge. Release the compression by loosening the screws alternately to full stop. Do not exceed 20 Nm (15 ft.lb.). Stayplate Insert a flat tool between the wedge and the stayplate to simplify removal of the wedge. Roxtec special tools are available. 4 5 Remove modules and stayplates. Note: Keep the rows sorted until it is time to re-install the transit. If a module is damaged or replaced, all modules in that row must be replaced. Re-installation 1 2 3 Make sure that the inside surfaces of the exposed packing space are free from dirt or dust. Lubricate the inside surfaces all around with Roxtec Lubricant, especially into the corners. Continue the re-installation. Note For optimum reliability, wait 24 hours or longer after installation before exposing the cables or pipes to strain or pressure. Optional wedge positions. The wedge can be placed in the top or bottom of the frame. Cables shall go straight through the frame. Make sure the tape is not damaged on re-used modules.

Article number: ASS2006004901 Document number: DOC-000312 version A DISCLAIMER The Roxtec cable entry sealing system ( the Roxtec system ) is a modularbased system of sealing products consisting of different components. Each and every one of the components is necessary for the best performance of the Roxtec system. The Roxtec system has been certified to resist a number of different hazards. Any such certification, and the ability of the Roxtec system to resist such hazards, is dependent on all components that are installed as a part of the Roxtec system. Thus, the certification is not valid and does not apply unless all components installed as part of the Roxtec system are manufactured by or under license from Roxtec ( authorized manufacturer ). Roxtec gives no performance guarantee with respect to the Roxtec system, unless (I) all components installed as part of the Roxtec system are manufactured by an authorized manufacturer and (II) the purchaser is in compliance with (a), and (b), below. (a) During storage, the Roxtec system or part thereof, shall be kept indoors in its original packaging at room temperature. (b) Installation shall be carried out in accordance with Roxtec installation instructions in effect from time to time. The product information provided by Roxtec does not release the purchaser of the Roxtec system, or part thereof, from the obligation to independently determine the suitability of the products for the intended process, installation and/or use. Roxtec gives no guarantee for the Roxtec system or any part thereof and assumes no liability for any loss or damage whatsoever, whether direct, indirect, consequential, loss of profit or otherwise, occurred or caused by the Roxtec systems or installations containing components not manufactured by an authorized manufacturer and/or occurred or caused by the use of the Roxtec system in a manner or for an application other than for which the Roxtec system was designed or intended. Roxtec expressly excludes any implied warranties of merchantability and fitness for a particular purpose and all other express or implied representations and warranties provided by statute or common law. User determines suitability of the Roxtec system for intended use and assumes all risk and liability in connection therewith. In no event shall Roxtec be liable for indirect, consequential, punitive, special, exemplary or incidental damages or losses. Roxtec International AB Box 540, 371 23 Karlskrona, SWEDEN PHONE +46 455 36 67 00, FAX +46 455 820 12 EMAIL info@roxtec.com, www.roxtec.com Roxtec and Multidiameter are registered trademarks of Roxtec in Sweden and/or other countries.