LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Similar documents
DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DMP 331i / DMP 333i LMP 331 i

Pressure transmitter For applications in hazardous areas Model IS-3

TPHADA TRANSMITTER FOR HIGH PRESSURE WITH DIGITAL AUTO-ZERO & SPAN

Mechanical flow switch for On/Off control

Level Measurement silometer FMC 420, FMC 423

Panel-mounting thermostats, type series EM

Inductive sensor NI3-EG08K-Y1-H1341

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Linear encoders without bearings incremental System for linear motion feedback

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Panel-Mounted Thermostat

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor BI1.5-EG08K-Y1

Selection matrix for electronic pressure switches

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Panel-mounting Thermostats EM Series

JUMO extherm-at Type , Explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Signet 2250 Hydrostatic Level Sensor

Connecting cables for valves, round plug connectors Product range overview

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Connecting cables NEBS, for sensors

Single Point Flow Monitor SW118 SW119

JUMO extherm-at Type , explosion-proof surface-mounted thermostat for zones 1, 2, 21, and 22

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

Inductive sensor With analog output BI15-M30-LI-EXI

Surface-mounting thermostat, type series ATH.-SE to monitor seagoing vessel equipment

Connecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath

-V- New. Connecting cables for valves, socket type B, industry standard Type codes Connecting cable with PUR cable sheath NEBV B2 W 3 F P K 0.

APPLICATIONS. Automatic warehouse. Trasportation lines

Oxymax W COS71. Technical Information. Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

MID-EX-E. Figure: MID-EX-E*010* ka052000en; Rev. 2.3 J

RSCC. Load cells. Special features. Data sheet

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Capacitive sensor BCT5-S18-UP6X2T-H1151

Surface-mounting thermostat, type series ATH.-SE

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Okta 1000, Roots pump without motor

Capacitance Limit Detection nivotester FTC 420/421/422

PROPORTIONAL VALVES Sentronic plus

Photoelectrics Through-beam Type PA18C.T..., DC

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

3 Cleaning. 4 Technical data

Connecting cables for valves, Sub-D Type codes

DRAW WIRE SENSOR. Series MH120 for mobile hydraulics applications. Key-Features:

TUC: Universal thermostat

ultrasonic sensors analogue output 0-10V, 4-20mA 2 programmable switching outputs

Sentronic PLUS. Electronic Pressure Regulator. Installation Manual

Capacitance Level Measurement Electronic insert FEC 12

Okta 600, Roots pump, 230/400 V, 50 Hz; 265/460 V, 60 Hz

Process transmitter RMA422

I Ex-protected connectors exlink I

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

-V- New. Connecting cables for valves, socket type A, EN Type codes Connecting cable with PUR cable sheath NEBV A1 W 3 F P K 0.

Surface-mounting thermostats ATH series

TFRH Hygienic RTD temperature sensor. CombiTemp TM

SERIES 400 SERIES 620

Ultrasonic Sensor Diffuse Mode Sensor RU40U-M18E-LIU2PN8X2T-H1151

CSM Color sensors. Color sensors for the detection of a single color in restricted space conditions

estat20 Electronic Humidistat with remote sensor head Technical data Electrical data Humidity Temperature +125 C

TFRN Industrial RTD temperature sensor. CombiTemp TM

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

M5 plug connector, 3-pin or hard-wire encapsulated cable. With. With connection cable. M5 plug connector. Active face LED

TFRN Industrial RTD temperature sensor. CombiTemp TM

Technical data. General specifications. 60 ma Power consumption P 0. 1 W Time delay before availability t v. 120 ms Interface. Protocol IO-Link V1.

Wall-/Pipe-Mount Level Indicator

Pressure transmitter COMPACT IO-Link,

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Process Transmitter RMA 422

Guide for installers. METTLER TOLEDO MultiRange System solution Point Ex.

HARTING Ethernet cabling cables and connectors, 4 wire

Contactless Encoder Analog RI360P0-QR24M0-ELIU5X2-H1151

2291 Guided Wave Radar Level Transmitter

Coils for solenoid valves

1 Inductive proximity switches. 5 Connecting cables. Highlights: New:

Contactless encoder RI360P0-QR24M0-INCRX2-H1181

Absolute Encoders Multiturn

ATEX. 50D (Pneumatic) Electronic pressure switch bar, bar, bar, bar, bar

Data sheet: Wilo-Drain TP 65 E 114/11 (1~230 V)

Material: Weight: IP Rating: Cable: Connector:

APPLICATIONS. Automatic warehouse. Trasportation lines

Transcription:

Slimline Probe Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire: 4... 20 ma others on request Special characteristics diameter 9 mm for cramped areas small thermal effect excellent long term stability excellent linearity Optional versions different kinds of cable specific versions e.g. special pressure ranges The slimline probe LMP 305 with silicon stainless steel sensor is designed for continous level measurement in confined space conditions. Permissible media are clean or waste water and thin fluids. A piezoresistiv stainless steel sensor with low thermal error, an excellent linearity and a long term stability, is basis of LMP 305. Preferred areas of use are Water level measurement in confined space conditions ground water monitoring depth or level measurement in wells and open waters drinking water system level measurement in container BD SENSORS GmbH BD-Sensors-Straße Tel: +49 (0) 92 35 / 98-0 www.bdsensors.com D - 9599 Thierstein Fax: +49 (0) 92 35 / 98 - info@bdsensors.de

Input pressure range Nominal pressure gauge [bar] 0. 0.6 0.25 0.4 0.6.6 2.5 4 6 0 6 25 Level [mh 2O].6 2.5 4 6 0 6 25 40 60 00 60 250 Overpressure [bar] 3 3 6 6 20 20 60 60 00 Output signal / Supply Standard 2-wire: 4... 20 ma / V S = 2... 36 V DC Performance Accuracy standard: nominal pressure > 0.4 bar: ± 0.35 % FSO nominal pressure 0.4 bar: ± 0.50 % FSO option: nominal pressure > 0.4 bar: ± 0.25 % FSO Permissible load R max = [(V S V S min) / 0,02 A] Ω Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / kω Long term stability ± 0. % FSO / year Response time < 0 msec accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) Nominal pressure P N [bar] 0. 0.25 0.4 > Tolerance band [% FSO] ± 2 ±.5 ± ± ± 0.75 TC, average [% FSO / 0 K] ± 0.3 ± 0.2 ± 0.4 ± 0. ± 0.07 in compensated range [ C] 0... 50 0... 70 Permissible temperatures Permissible temperatures medium: -0... 70 C storage: -25... 70 C Electrical protection 2 Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 6326 2 additional external overvoltage protection unit in terminal box KL or KL 2 with atmospheric pressure reference available on request Electrical connection Cable with sheath material 3 PVC (-5 70 C) grey PUR (-0 70 C) black FEP (-0 70 C) black others on request 3 cable with integrated air tube for atmospheric pressure reference Materials (media wetted) Housing stainless steel.4404 (36L) Seals FKM / EPDM Diaphragm stainless steel.4435 (36L) Protection cap POM Cable sheath PVC / PUR / FEP Miscellaneous Connecting cables cable capacitance: signal line/shield also signal line/signal line: 60 pf/m (by factory) cable inductance: signal line/shield also signal line/signal line: µh/m Current consumption signal output current: max. 25 ma Weight approx. 00 g (without cable) Ingress protection IP 68 CE-conformity EMC Directive: 2004/08/EC Wiring diagram 2-wire-system (current) p supply + A VS I supply pressure and level

Pin configuration Electrical connection cable colours (DIN 4700) Supply + wh (white) Supply bn (brown) Dimensions (in mm) Shield gn/ye (green / yellow) Protection cap removable This data sheet contains product specification, properties are not guaranteed. Subject to change without notice. www.bdsensors.com

Technical Accessories Data Mounting flange with cable gland Technical data Suitable for all probes Flange material stainless steel.4404 (36L) Material of cable gland standard: brass, nickel plated on request: stainless steel.4305 (303); plastic Seal insert material: TPE (ingress protection IP 68) Hole pattern according to DIN 2507 Version Size (in mm) Weight DN25 / PN40 D = 5, k = 85, b = 8, n = 4, d= 4.4 kg DN50 / PN40 D = 65, k = 25, b = 20, n = 4, d= 8 3.2 kg DN80 / PN6 D = 200, k = 60, b = 20, n = 8, d= 8 4.8 kg Ordering type Ordering code DN25 / PN40 with cable gland brass, nickel plated ZMF2540 DN50 / PN40 with cable gland brass, nickel plated DN80 / PN6 with cable gland brass, nickel plated Cable clamp Suitable for all probes with cable 5.5... 0.5 mm Material standard: steel, zinc plated optionally: stainless steel.430 (304) Weight approx. 60 g Ordering type Terminal clamp, of steel, zinc plated Terminal clamp, of stainless steel.430 (304) Display program CIT 200 Process display with LED display CIT 250 Process display with LED display and contacts CIT 300 Process display with LED display, contacts and analogue output ZMF5040 ZMF806 CIT 350 Process display with LED display, bargraph, contacts and analogue output Ordering code Z00528 Z00527 CIT 400 Process display with LED display, contacts, analogue output and Ex-approval CIT 600 Multichannel process display with graphics-capable LC display CIT 650 Multichannel process display with graphics-capable LC display and datalogger CIT 700 Multichannel process display with graphics-capable TFT monitor, touchscreen and contacts PA 440 Field display with 4-digit LC display cable gland M6x.5 with seal insert (for cable- 4... mm) For further information please contact our sales department or visit our homepage: http://www.bdsensors.com LMP305_E_9032 pressure Tel and +49 level (0) 92 35 / 98-0 www.bdsensors.com Fax +49 (0) 92 35 / 98 - info@bdsensors.de

Ordering code LMP 305 LMP 305 - - - - - - - - - Pressure in bar in mh 2 O 4 0 0 4 0 Input [mh 2 O] [bar].0 0.0 0 0 0.6 0.6 6 0 0 2.5 0.25 2 5 0 0 4.0 0.40 4 0 0 0 6.0 0.60 6 0 0 0 0.0 0 0 6.6 6 0 25 2.5 2 5 0 40 4.0 4 0 0 60 6.0 6 0 0 00 0 0 0 2 60 6 6 0 2 250 25 2 5 0 2 9 9 9 Housing Stainless steel.4404 (36L) Diaphragm Stainless steel.4435 (36L) Output 4 20 ma / 2-wire Seals FKM EPDM Accuracy standard for P N > 0.4 bar 0.35 % 3 standard for P N 0.4 bar 0.5 % 5 option for P N > 0.4 bar 0.25 % 2 Electrical connection Cable length Special version PVC-cable PUR-cable FEP-cable standard cable with integrated air tube for atmospheric pressure reference in m 9 9 9 3 2 3 0 0 0 9 9 0.0.203 This price list contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.