Smothers Theatre Rental Technical Specifications Pepperdine University

Similar documents
Smothers Theatre Rental Technical Specifications

Smothers Theatre Technical Specifications Pepperdine University

Concert Hall Technical Specifications

The Breen Center for the Performing Arts Saint Ignatius High School

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Technical Specifications

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Sandusky State Theatre Technical Specifications

Concert Hall Technical Specifications

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Amarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101

Technical Specifications

Technical Specifications

Technical Specifications and Inventory Spring 2018

Arcadia Performing Arts Center Technical Specifications and Information

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Marjorie S. Deane Little Theater

Dale F. Halton Theater Technical Specifications

SAINT ANSELM COLLEGE DANA CENTER

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

Patriots Theater at the War Memorial Technical Data

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Dr. Fred Speckeen Theatre. Information and Technical Specifications

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Technical Specifications

University of Pittsburgh at Bradford Blaisdell Hall/Pitt-Bradford Arts

Facility Information

Technical Information

THE BELDING THEATER. 166 Capitol Avenue Hartford, CT The Bushnell Box Office: (860) The Bushnell Box Office FAX: (860)

Parking for cars, busses and tractor/trailers available on the east side of building. Handicapped parking available on the north side of building

Performing Arts Theatre

Technical Specifications. Taylor Little Theater

Tucker Theatre Policies and Procedures MTSU Department of Theatre 205 Boutwell Dramatic Arts Murfreesboro, TN 37132

Dinkelspiel Auditorium - Technical Specifications

Jerry Fay Wilhelm Center for the Performing Arts Technical Specifications AUDITORIUM

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

Technical Specifications

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

1/16 Virginia Tech/Blacksburg, VA/Haymarket Theatre

Rental Information. Smothers Theatre Raitt Recital Hall Lindhurst Theatre

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

TECHNICAL PACKAGE.

VENUE TECHNICAL REQUIREMENTS

SHUBERT THEATER 247 College Street, New Haven, CT

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

Quick-Advance Fact Sheet

RPAC REDLANDS PERFORMING ARTS CENTRE

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Technical Specifications

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Irish Heartbeat TECHNICAL RIDER. Video Projection Requested

Lighting Information

Stage Height: 3-2 CL to SL: 19-9 CL to SR: 22-3

Technical Services and Specification

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

TECHNICAL INFORMATION

THEATER INVENTORY * Inventory does not include equipment in rep / **Additional cost - Not included in theater rental fee

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

Laura Turner Hall Overview. Sound System Overview

Facility Rental Reservation & Contract

Technical Rider Vocal Point Season Performing Arts Management

Please note: the standard seating capacity of The Kaye Playhouse at Hunter College is 624. added to the orchestra lift at an extra charge.

Technical Specifications

Bartlesville Community Center

PRODUCTION INFORMATION

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.

SECREST AUDITORIUM TECHNICAL PACKAGE

TECHNICAL INFORMATION DRIVING DIRECTIONS

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Jane Mallet Theatre Technical Specifications

Directions. Driving directions and other UCSD maps

DEREHAM MEMORIAL HALL

Downtown Arts Center Tech Packet. General Information

Visy Theatre technical information and general specifications 2019

Baker Hall Technical Information Package

Technical Information

Auditorium Seating VISY THEATRE TECHNICAL SPECIFICATIONS

ARTPARK MAINSTAGE THEATER TECHNICAL PACKET

NORTH CHARLESTON PERFORMING ARTS

Clayton Center for the Arts Ronald and Lynda Nutt Theater Technical Specifications December 2014

Centre Stage and City Room at Surrey City Hall Venue Information

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

Camden Opera House Theater. Technical Information

SUBJECT TO CHANGE ADDENDUM ATTACHED AND MADE PART OF THE CONTRACT BETWEEN PRODUCER, BOOKING AGENT, AND THE LOCAL PRESENTER.

Theatre Technical Specifications

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

Theater Technical Information

Anvil Theatre. Technical Information

Studio 180. Electronic and Print versions of the venue ground plan are available from the Technical Director.

SABAN THEATER, BEVERLY HILLS TECHNICAL SPECIFICATIONS

Paramount Theatre Production Recap

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Little River Band Production Rider 2018

NORTH CHARLESTON PERFORMING ARTS

The performance is about 100 minutes long, excluding intermission. ACT 1 is 75min, ACT 2 is 20min. Intermission 20-25min.

Transcription:

Smothers heatre Rental echnical Specifications Pepperdine University Staff Contacts heatre Operations Manager Paul Vacchiano E: Paul.Vacchiano@Pepperdine.edu P: 0-0-0 Hospitality, Merchandise Advance Director of Production Danielle Lobello E: Danielle.Lobello@Pepperdine.edu P: 0-0- Production and Schedules Advance Box Office and Patron Communications Manager yler Gabbard E: yler.gabbard@pepperdine.edu P: 0-0- Production Manager Nathan Grater E: Nathan.Grater@Pepperdine.edu P: 0-0- From Pacific Coast Highway, turn onto Malibu Canyon Road (northbound). At the first traffic light, Seaver Drive, turn left and enter the campus. From the Ventura Freeway (US 0), exit at Las Virgenes Road, Malibu Canyon. Head south on Las Virgenes (which turns into Malibu Canyon Road) for 0 miles to Seaver Drive. urn right on Seaver Drive and enter the campus. At the booth, ask for directions to the theatre. he theatre is adjacent to the Seaver College Main Lot (Lot B). echnical Specifications All technical needs and staffing must be advanced at least one month prior to the performance. Crew he minimum back of house crew is three persons and a echnical Supervisor. he Center for the Arts may require additional crew based on show needs. All Federal and California labor laws will be followed. Smothers heatre House Capacity Without Seated Pit: capacity in rows With Seated Pit: 0 capacity in rows Stage Dimensions Proscenium Height: 0-0 Proscenium Width: -0 Stage Depth with lowered pit: - Stage Depth with raised pit: - Stage Width including wings: -0 Scenery Door USC: - h by -0 w Stage Floor he wooden stage floor is covered with ¼ tempered fiber hard board. he floor is painted matte black. Holes and screws may be used in the floor with approval. enant is responsible for repairing any large holes as deemed necessary by theatre representative.

Fly System All flys must be operated by paid Center for the Arts Personnel. Rigging Information Batten High rim: Varies for each pipe due to building architecture. Batten Low rim: -0 above stage floor House Pipes: All battens are pipe construction with -0 width, some are adjustable to 0-0 wide House soft goods may not be moved for rentals unless approved in advance. Please advance any additional rigging items. Line Sets sets with center and lift lines Single purchase manual control Arbors All arbors are -0 length with 00lb capacity Rigging Schedule : See additional PDF attachment Soft Goods Main Curtain: Black Velour Borders: Black Velour Legs: Speakers Curtain: Mid Stage Black: Up Stage Full Black: White Cyclorama: Scrim: @ Red Velour, % fullness (traveler) @ 0-0 w x -0 h @ -0 w x -0 h @ -0 w x 0-0 h @ -0 w x -0 h, 0% fullness (traveler) @ -0 w x -0 h, 0% fullness @ 0-0 w x -0 h, flat black @ 0-0 w x -0 h @ 0-0 w x 0 - h Backstage Facilities Loading Area Location: Rear of facility with no dock. Load-In is stage level through the scene shop. Loading Bay Dimensions: -0 w x -0 d Loading Door: -0 w x 0-0 h CFA does not have access to a scene shop. All painting and repairs must take place on stage or off site. Wardrobe Location: Dressing Rooms: Green Room: Locker Rooms: Quick Change: Additional Space: Stage Level chorus rooms located in hallway off stage right Green room located in hallway off stage right. locker rooms, male and female Portable quick change locations available upon advance Larger classroom or black box theatre available for warm up or dressing spaces, additional cost for use

Restrooms: Electrics Company Switch Restrooms are shared with working student/staff personnel. Separate from audience. - 0amp phase company switch with Cam-Lok Use must be advanced Stage Lighting Control All lighting must be operated by paid Center for the Arts Personnel EC Ion 000 with 0 fader wing Universes: Universe Conventional Fixtures, Universe Intelligent Fixtures Show Position: in upper center booth at rear of auditorium Dimmers/Patching ype: EC Sensor dimmers Connection: Stage Pin Number: 0 Wattage:.k ea. Conventional Instrument Inventory Conventional lights will be in House Plot unless otherwise advanced. his includes: Front Cool and Warm Wash op Light systems in Red, Blue and Amber High Side Breakup and Warm System onstage specials specials from FOH two-fered circuits/specials from balcony rail EC Source Lustr+ Cyc Lights Disco Ball as advanced Dance Booms as advanced Additional lights can be added per advance House Plot : See additional PDF attachment Intelligent Lighting Inventory Only available with additional paid Center for the Arts programmer Position of these cannot be moved from their house plot locations. -Vari-Lite VL000AI Moving Lights -Robe Colorspot A Follow Spots Only available with additional paid Center for the Arts operator(s) -Lycian Midget Spotlights located in the audience left and audience right sections of the upper booth. Spotlights may not be moved from their locations

Haze -DF-0 Hazer (must be advanced as per fire policy) Only available with dedicated Center for the Arts Fire Watch Personnel. If haze is used, the double doors on either side of the backstage hallway must remain closed as per LA County Fire Code. Projection Equipment Only available with additional paid Center for the Arts operator(s). Projection screen: Projector: Location: Lens Options: Playback Options: x 0 front projection screen Panasonic P-DZ0K 0,00 Lumens, :0 Aspect Native, Full HD Center Light Booth Long hrow Lens E-DLE0 (in projector) Short hrow Lens E-DLE (available per advance) PC computer with Power Point, Windows Media Player and VLC Player DVD Player VGA connection for renter provided computer. Renter must supply necessary adapter to convert to VGA. Sound Equipment All audio equipment must be operated by paid Center for the Arts Personnel. he mix position is located at house left behind the last row of seats approx. from edge of stage. Position cannot be moved. here is a x location audience right of the house mix position for a road mix position. Our house db limit is db C weighting. FOH Equipment FOH Console: Stage IO: FOH IO: FOH Speakers: Wired XLR Inputs: Monitor Speakers: Wired XLR Inputs: Yamaha CL: mono/ stereo/ aux/ matrix/fx/ DCA -Yamaha RIO0-D -Yamaha RIO-D -Yamaha IO0-D -EAW KFe (Flown left and right, tri-amped) -Yamaha SWIV (Mono Subs) -Danley SM0F (Center Cluster) 0- copper onstage inputs and onstage return lines -EAW LA (monitor wedges) 0-onstage inputs and onstage return lines Video aping Audio feed is possible for videotaping purposes however it must be requested no later than one hour to show time.

LA County Fire Code requires blocking off rows if necessary due to camera equipment, please consult CFA Staff for best locations to place video equipment. Communications and Paging Clear-Com headset communications available to all necessary stations. Single channel operation. here is a stage audio monitor to control booth and dressing rooms. Monitor System here is no in house monitor console or split snake. All monitors are mixed from FOH. Additional Equipment and Accessories Microphones, wired and wireless (list available upon request and must be advanced) Microphone stands Choral Risers and orchestra shell (at additional cost) Music stands and chairs Vinyl Dance floor (at additional cost) Steinway Hamburg Model D (at additional cost of piano tuning) Genie GS- 0 Scissor Lift JLG 0MVL Personnel Lift General Info Pepperdine is a dry campus and no alcohol is allowed. No food or drink is allowed in backstage, on stage or in the house besides water. Smoking is only allowed in designated areas on campus Open flames are not permitted in the theatre. Firearms, live explosives and lasers require prior approval and possible additional Center for the Arts staff. Shoes must be worn at all times in Smothers heatre and can only be removed when going on stage. Parking Info Parking is worked out as per advance. We can make space for a Semi and a level parking surface for a tour bus. When the tour bus has a trailer, there is a 0 downhill push to the loading dock. here is no shore power. Generators are fine to run. Semi-trucks and busses are not permitted to enter campus before :00am because of nearby residential housing. Lobby Use In order to use the front doors of the lobby, a House Manager must be present. If a backstage crew is here, the lobby can be accessed but only through the theatre, not through the front doors. We can provide tables in our lobby plus chairs for use by renters. If your sales personnel accepts and processes credit cards, the University s Wi-Fi or wired networks may not be used for processing credit cards. Outside Rental Companies Renters are allowed to set up additional outside rentals to be delivered at the venue day of for the show. Any deliveries or pick-ups need to be coordinated in advance and companies need to be approved by CFA staff. Storage and Dead Cases Because of the strict fire codes, no storage of dead cases, instruments, costumes, boxes, or other miscellaneous touring equipment may occur in the hallways surrounding the theatre. Our scene shop is

also unavailable for storage because of its continual use. All storage must occur in designated locations on stage or as directed by the Center for the Arts staff. Wi-Fi Information How to Connect: First, connect to the Pepperdine network. Open a web browser on your device and visit any webpage. You will be redirected to WavesConnect. If you are not, go to pepperdine.edu/wavesconnect. Click start and select the Visitor heading. After you select this you will be required to agree. Click register and after a short period your internet will be ready for use. his must be done every hours.

Label Legend Vectorworks Educational Version R Color emplate Unit Number L+R R0+R 00 L+R R0+R 00 L+R R0+R 00 L+R R0+R 00 L+R R0+R st BEAM : - + -0 Dimmer 0 0 Channel L+R R0+R L+R R0+R L+R R0+R L+R R0+R L+R R0+R nd BEAM 0: - 0 0 0 0 0 0 0 F 0 0 0 0 0 F L+R R0+R L+R R0+R L+R R0+R L+R R0+R L+R R0+R L+R R0+R rd BEAM : - 0 0 BOX SR NEAR BOX SR MID 0 L0 0 L0 BLUES 0 0 HOUSE -0 0 0 L0 0 0 0 0 0 0 0 0 (drawn out of position for clarity) L0 BOOH RAIL : 0-0 HAZE 0 0 L0 L0 BOX SL NEAR BOX SL MID R R R R Instrument Key Etc Source deg BOX SR FAR SR BOX BOOM Color Summary Color Size Count L0." L+R." L0." R." R0+R." EC Source Etc Source deg Source PAR WFL Robe ColorSpot A Vectorworks Educational Version Show heatre House Repertory Plot Smothers heatre Subject Beams Over House Revised June, 0 Plate Scale # (of ) /" = ' SL BOX BOOM BOX SL FAR

Vectorworks Educational Version / / / / / /0 / / / / / # ELECRIC : - + - 0 0 0 0 0 0 0 0 0 0 0 CYC - NOE: Relay circuits + - park at FULL! 0 0 R 0 0 R 0 L0 0 LH L 0 / 0 0 0 L0 LH L 0 0 L0 0 0 LH 0 0 L / 0 0 0 L0 0 0 LH 0 L 0 R 0 R # ELECRIC : -0 00 0 R 00 0 0 R 0 L0 LH L 0 0 L0 LH L 0 0 L0 0 LH L 0 0 0 L0 LH L 0 R 0 R # ELECRIC 0: - + -00 F 0 0 0 0 0 F L+RR0+R L+RR0+R 0 L+RR0+R L+R R0+R 0 0 #A ELECRIC / /0 0 R 0 R 0 0 L0 LH L 0 0 0 L0 LH L 0 0 0 L0 LH L 0 0 0 0 L0 LH L 0 R 0 # ELECRIC : - R + - 0: - B R SL Instrument Key Label Legend R R R R 0 SR AB Etc Source deg EC Source Etc Source deg S Source PAR WFL VL-000 Color Summary Color Size Count L0." L." L+R." LH."." R." R0+R." R." Vectorworks Educational Version Show heatre R 0 House Repertory Plot Smothers heatre Subject Above Deck Electrics Revised June, 0 Color emplate Unit Number Dimmer Channel Plate Scale # (of ) /" = ' 0: - + -00 R R R SL AB

Vectorworks Educational Version 0 0 0 0 0 R R 00 R 0 R R 0 R 0 R R L L 0 L 0 L L 0 L 0 L L <------ DS SR DANCE BOOMS SL DANCE BOOMS DS ------> Instrument Summary Etc Source deg Label Legend Color Summary Color Size Count L Source deg Source deg R Source deg R 0 Color emplate Unit Number Dimmer Channel Vectorworks Educational Version Show heatre House Repertory Plot Smothers heatre Subject Booms On Deck Revised June, 0 Plate Scale # (of ) /" = '

Pepperdine University Center for the Arts Lineset Schedule Detail As of -Jul 0 Lineset Distance from Plaster Line MAX Out rim MAX Out rim w/ SR Extension Out '-" Purpose Length Extensions Available Each Side Length w/ Extensions Notes 0'-0" ' *same* Cyclorama 0' -- -- '-" ' *same* ' @ ' 0' 0 '-0" ' *same* ' @ ' 0' '-" '-" *same* FULL BLACK # ' @ ' 0' '-" '-" *same* ' @ ' 0' '-" '-" *same* ' @ ' 0' '-0" ' *same* ' @ ' 0' '-" '-" *same* LEGS # ' @ ' 0' '-" '-" *same* ELECRIC 0' -- -- '-" '-" *same* BORDER # ' @ ' 0' '-" '-" '-" ' @ ' 0' 0'-0" '-" '-" ' @ ' 0' 0 '-" '-" *same* ELECRIC 0' -- -- '-" '-0" '-" ' @ ' 0' '-" '-" '-" Legs/Border # ' @ ' 0' '-0" '-" '-" ' @ ' 0' '-0" '-0" '-" FULL BLACK # ' @ ' 0' '-" '-" '-0" Black Scrim ' @ ' 0' '-" '-" *same* ' @ ' 0' '-0" 0'-" *same* ELECRIC 0' -- -- '0" '-" *same* LEGS & BORDER # ' @ ' 0' '-0" '-" *same* ' @ ' 0' 0 0'-0" -" *same* Speaker's Curtain (Black) ' @ ' 0' Has ravel rack '-" '-0" *same* Projection Screen ' @ ' 0' '-" '-" *same* ' @ ' 0' '-0" '-" *same* Border # ' @ ' 0' '-" -" *same* Leg # ' @ ' 0' '-" *** *same* ELECRIC A (tied to ) ' @ ' 0' ied to LS '-" '-" *same* ELECRIC (tied to A) 0' -- -- ied to LS ------ ------ ------ **Side ab Electrics** @ ' -- -- abs on the SAME Arbor '-0" *** *same* House Portal ' @ ' 0' Has ravel rack '-0" *** *same* House Grand Drape 0' -- -- 0 0'-" '-" *same* ' @ ' 0' 00 0'-0" *** *same* Procenium Portal ' -- --