Standard RS232 RS ma

Similar documents
02/11/2015

Electronic converter for level transmitters MT03L Instructions manual

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

MT03A Electronic converter for flow rate transmitters

Process Transmitter RMA 422

PRINCIPLES AND APPLICATIONS

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

LONWORKS Fibre Optic Converter

Quick Operation Guide of LTN7700/7600 Series NVR

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Process transmitter RMA422

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

INSTALLATION & USER GUIDE

Datasheet - SRB301LC 24VAC/DC

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

Operating instructions Electronic preset counter Type series 717

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

Magnecraft Power Relays

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

BE3-GPR GENERATOR PROTECTIVE RELAY

Ordering details. Approval. Classification

Intelligent Security and Fire Ltd

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

ODW-621. RS-232 Point-to-point applications

Fibre Optic Modem ODW-611

LED control gear Compact dimming. Uconverter LCAI 2x38 W 0500 K013 one4all ECO series. Ordering data

High Performance Outdoor Test Translators

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

DCP100 Digital Control Programmer Specifications

High performance circuit breakers

Multifunction devices

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

Series CT7N Bimetallic Overload Relays

MK4 S CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (SYNCHRONOUS SERIAL OUTPUT)

Absolute Encoders Multiturn

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P

SCALE & WEIGHT DISPLAYS

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Fibre optic router for TP/FT-10 LRW-112PP

Model IQ4-PC User Manual Revision Date:

AF-300 E11 Adjustable Frequency Drive

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

PQ-Box 100 Quick Start Instructions

LONWORKS Fibre Optic Router

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Description. Specifications and Ordering Information 1900/27 Vibration Monitor

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

Standard signal metering in wall-mounting case

ISOMAG THE FRIENDLY MAG METER. Gas, mists or vapours Zone 0 1G Gas, mists or vapours Zone 1 2G. Gas, mists or vapours Zone 2 3G

Sensopress LCD Special English

Gamma instabus. Technical product information

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

LAUREL ELECTRONICS, INC.

Multifunction Digital Timer

ABB EQmatic Energy Analyzer, M-Bus QA/S , 2CDG110226R0011, QA/S , 2CDG110227R0011

User Manual M1. Direct current / Direct voltage signals 0-20 ma, 4-20 ma, 0-10 VDC. Technical features:

ORDERING Page 6 BASLER RELAY STANDARDS, DIMENSIONS, ACCESSORIES Request bulletin SDA

User Manual. TCU/RCU RF Head Control Units. TCU/RCU Analogue 11/6/

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Henkel Installation Handbook LINEGUARD 2001

Fibre Optic Modem ODW-622

Wall-/Pipe-Mount Level Indicator

K-BUS Dimmer Module User manual-ver. 1

DUCATI SISTEMI S. P. A. DUCA47-96 USER MANUAL

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

Digital output modules

Ku-Band Redundant LNB Systems. 1:1 System RF IN (WR75) TEST IN -40 db OFFLINE IN CONTROLLER. 1:2 System POL 1 IN (WR75) TEST IN -40 db POL 2 IN

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

Controllers, series CON Indicators, series IND. Controllers and indicators

Operating Instructions

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Rack mounted telephone- and leased line modem for industrial applications

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

MCR3 POWER EQUIPMENT. Microprocessor Controlled Constant Current Regulator. Compliance with Standards. Uses. Features

OM2000N INSTALLATION MANUAL

M-relays, 2, 3 or 4 pole, 7-12 A Datasheet

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

PROXIMITY SWITCHES INDUCTIVE TUBULAR SENSOR M30 SERIES HIGHLIGHTS APPLICATIONS

Light Curtain Type LA

Detect Color and Shape for various inspection

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

2-output DALI controller

DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

Digital differential Pressure switch Model DPS Instruction manual

USER MANUAL. Compact dimensions 6 DIN modules, with 4 LED s display with 7 segments, for an excellent reading of the measurements

DATA SHEET Panorama Rudder Indicator, TRI-2

IV 251. Signal Converter SSI => Analogue and SSI => Serial. Operating Instructions. control motion interface

Model Number Structure

Hardware & software Specifications

Transcription:

1 / 5 CONTROL AND VISUALIZATION OF AC CURRENT IN SINGLE PHASE LINES BY EXTERNAL SHUNT Function Operating mode Current control Frequency control DC component control Shunt Timer Resolution Current precision Frequency precision Display of the reading value Top of scale Offset Output relay Output 4-20 ma PC communication Range Current relay for AC single phase lines. Performs the control of the current, the frequency and the DC voltage component running through a shunt connected at a line independent of the supply voltage. Configurable by the user. Each one of the available relays it is assigned with its own operating mode for one or more magnitudes, reacting by the first one which is produced. Operativity by max. and/or min. current. At each case, adjustment for detection and/or for release. RMS reading value. Adjustable from 43..70 Hz. Operativity by max. and/or min. frequency. At each case, adjustment for detection and/or for release. If the frequency changes in such a value that the relay loose the required precision for a normal operating mode, it switches to the alarm mode (See page 3 for detailed information). Adjustable from 0..3 VAC. Operativity by maximum DC component. Adjustment for detection and/or for release. It can be used three values of shunt: 50 mv, 60 mv and 100 mv. Associable to the detection and/or to the release of whichever relay. Adjustable from 0,01s..999,9h Repeating precision ±30 ppm 1 mv Taken over the read value: 1% Taken over the read value: 0,3% The value of the read magnitudes is displayed by means of the following status screens: CURRENT: Current across the shunt (ma, A or ka, according to the range) FREQUENCY: Frequency in the line (Hz) DC COMPONENT: Component of the DC voltage in the line (VDC) This option sets the maximum value of the choosen magnitude. It can be applied a correction factor of the read current in front of an standard instrument. From 1..3 independent relays, SPST NO. By default, we supply three relays. It is assigned to whichever of the measured magnitudes (current, frequency, DC component) to be transmitted through a 4-20 ma current loop, being able to coexist with the relays. Precision: 1% additional to the read value. This kind of output is optional. It is possible to establish different types of communication with a computer (see also last page): - By telephonic connector that incorporates standard equipment and CPBZ programming interface. - By a RS232 connection (optional). - By a RS2485 connection and SBAZ converter (optional). [V10] 1..100 mv AC Communication (According options) Standard RS232 RS485 4-20 ma Code 0 Code 3 Code 8 Code 4 Connection diagram

Control of maximum/minimum current, alarm for maximum and alarm for minimum 2 / 5 In this application a current threshold is controlled (maximum/minimum) by means of the relay R3. Relay R1 is set for the detection of an alarm of maximum current and R2 for a minimum one. Settings available in program 1 for relays R1, R2 and R3. Parameters must be adapted to the installation. mv Scaling control of maximum current In this application, three different set points of maximum current are controlled, assigning each one to a different relay. Settings available in program 2 for relays R1, R2 and R3. Parameters must be adapted to the installation. mv

AC AC - DC 2/4 L A1 Constructive and enviromental data Output relays Resistive AC load DC Inductive AC load DC Mechanical life Max. mech. operations Electric life at full load Contact material Operating voltage Voltage between contacts Voltage coil/contact Isolation resistance Indication Voltage phase-neutral Overvoltage category Shock voltage Pollution degree Protection Approx. weight Store temperature Operating temperature Humidity Housing Leds window Buttons, connector, clamp Connector s terminals Screws torque 6 A / 240 V 6 A / 24 V 3 A / 240 V 3 A / 24 V > 10 6 oper. 18.000 operations / hour 360 operations / hour AgSnO Alloy 240 VCA (85 ºC) 1000 VAC 4000 VAC > 100 M (500 VDC) 1 red led per relay 300 V I I I 4 kv 2 (EN61010) IP 20 280 g -30..+80ºC -20..+50ºC < 95% HR Cycoloy - Light grey Lexan - Transparent Technyl - Dark blue Brass 0,8 Nm Dessigned and manufactured under EEC normative. Directives referred: Electromagnetic compatibility: EMC 2004/108/EEC. Low voltage: LVD 2006/95/EEC. Hazardous substances: 2011/65/EEC Plastics: UL 91 V0 Supply voltage Parts of the equipment Supply voltage code Galvanic isolation Frequency Operating margins Consumption Startup time Deteccion time Reset Indication * In the worst of the cases Options selection Screens selection Change of values Text edition Validation Signaling of the supply voltage and status of the relays A2 N [024].. [440] [903] [904] 4000 V 2500 V 50 Hz 60 Hz - +10% -15% 15-70 V 60-240 V 2,5 VA 3,5 W 3,1 W 100 ms 96,6 ms < 525 ms * < 135 ms* 25 ms 21,6 ms 115 ms 110 ms > 1 network cycle >70 ms* and/or -30% of the and/or -30% of the nominal voltage nominal voltage Green led Contacts of the relays Supply voltage input LCD screen Connector communication (under) Control - Interface Number of relays Type of relays Communication Version Supply Range Order code 9 - Q - With display Default languages: Spanish English French Catalan (Other on request) Without display Without communication 0 - No relays 3-3 relays 0 - No relays A - SPST NO 0 - No bus 4-4-20 ma 3 - RS232 8 - RS485 00..99 [024] 24 VAC [110] 110..125 VAC [230] 220..240 VAC [400] 380..415 VAC [440] 440 VAC [903] 15..70 VAC/DC [904] 60..240 VAC/DC [V10] 1..100 mv U - Without display Communication RS232 / RS485 (By default, 3) (By default, A) (By default, 0) (By default, 00) To compose a reference, select one option of each one of the columns. Example: 9 3A000 400 V10 Dimensions [ S ]

User s manual How to programm Types of screens Interactive menus Changing values User s programms Display lighting Value added GENERAL CHARACTERISTICS OF THE DIGITAL CONTROL RELAYS For a wide knowledgment of the options offered by the digital control relays, the own User s Manual for each model must be read. Although an issue is given with every purchased equipment, a copy can be donwloaded in our web site (www.disibeint.com). The digital control relays can be indistinctly programmed either with the buttons placed in the front of the housing or with a personal computer. Please refer at the end of this page to learn more about the PC programming alternative. Status: They show the actual values of the magnitudes controlled by the relay. User: Where the user can write a customized text to help to the relay identification. Options: For accessing to the menus for the options selection. Informatives for values: They show the information of the different set parameters. Change of value: For modifying the values of the different values. Screens menus: Group of screens related under the same concept and that can contain whichever type of the screens previously described. For an ease programming, into the menus only the options that can be set are the ones visible. The rest of the options are not visible. This feature is interactive, ie., it is produced automatically according whether other functions are activated or not. The screens for changing the values contain the margins betwen such value can be adjusted. These margins can depend of other options and this is because different margins could be displayed according to other previous relations. Provided by factory two programs with options and pre-configured settings for quick start-up team. In most cases, these parameters should be tweaked to suit the characteristics of each installation. The user can create your own program and store it on your computer. The display remains backlihghted while it is accessed to the different screens. If any button is not pressed for longer than 30 seconds, the light turns off. In order to turn the light on, it is enough to press any button. - Four languages available in each relay - Graphic bar for the intuitive visualization of the displayed value - Historical control of the maximum values obtained by the relay - Screen s refresh selectable between 1 and 8 times per second - Possibility of locking the keyboard to avoid any undesired modification - Complementary timing functions Alarm by frequency deviation SPECIFIC CHARACTERISTICS FOR THE MODEL This option affects to those relays with any voltage parameter activated. By default, this option is activated. Inhibits the activation of the relay in the state of alarm when the requency is deviated in ± 0,4 Hz during the detection process, and of ± 0,3 Hz during the releas process. For this kind of deviation in the frequency, the operating precision is reduced. More the frequency in the net is deviated, worse precision when reading its voltage. If this option is deactivated, you must remember that the reading precision of the voltage parameters decrease when the frequency gets deviations from its nominal values (50 Hz / 60 Hz). You must consider this reduction of precision when setting the values for detection and/or release. PC COMMUNICATION decom Communication and programming software for the digital control relays. It allows the interactivity between the different types of communication: through the interface, RS232 or RS485. It displays the complete data related to the relay, gruoped by concepts and easing the intuitive programming. It has control tools to do not exceed the operating margins of each model according to its range. It is provided with templates to facilitate the programming of each model. It allows to store the own settings. Windows XP operative system (.NET Framework required).

5 4/4 / 5 OUTPUTS COMMUNICATIONS REMOTE PROGRAMMING FROM PC CURRENT LOOP 4-20 ma RS232 COMMUNICATION STANDARD MODE ACCESSORIES 1 2 Interface for remote programming from a PC. It allows the connection between whichever digital relay not provided with bus and a PC. Not required for devices provided with bus RS232, RS485 or with 4-20mA output. *Connector RJ 12 (6 pins) Seen from the cable entry * 88.88 ma 2 RxD 3 5 *RS-232 wire 3 5 3 5 *Serial adapter/usb SBAZ Supply voltage 12..30 VDC RS485 to RS232 signal converter for the remote programming or for the data capture and visualization from a PC. It allows the connection of up to 31 digital control relays provided with RS485 communication bus, to get a unique codified RS232 output. 2 RxD 3 3 *Connector RJ 10 (4 pins) 5 5 RS485 COMMUNICATION Seen from the cable entry # 1 # 2 # 31 SBAZ *RS-232 wire *Serial adapter/usb * Disibeint not supply cables or connectors. You can find these products in stores specializing in computer equipment. 5 3 2 2 3 5 Segle XX, 91 E08032-Barcelona Rev. 03/01 30/12/16 DISIBEINT reserves the right to modify this document without previous notice T: +34 934 330 370 F: +34 934 354 532 www.disibeint.com disibeint@disibeint.com