Anatomical and Functional Neuroimaging of the Marmoset Brain

Similar documents
International Symposium on Global Neuroscience Cooperation. Sunday, July 29 th, 2018

Multi echo Multi slice (MEMS) High Performance fmri at CFMRI... 1

RAD 465 (MRI) Lecture one (Pulse Sequences) Ruba Khushaim MSc

Image quality in non-gated versus gated reconstruction of tongue motion using Magnetic Resonance Imaging:

PATIENT POSITION IMAGING PARAMETERS

MSK Imaging Fundamentals

True comfort and flexibility with the power of 3T.

4/14/2009. The Big Picture of Quality. MRI Quality Assurance and ACR MRI Accreditation Program. Basic Elements for Image Quality.

EPI. Thanks to Samantha Holdsworth!

Biograph Vision See a whole new world of precision

Multiparametric MRI Prostate Imaging Protocol November 2015 Full Acquisition Protocol with Parameters GE 3T Magnet with Software Version DV25

Requirements for Imaging

Peacefully quiet. Remarkably fast.

Comparison of Robarts s 3T and 7T MRI Machines for obtaining fmri Sequences Medical Biophysics 3970: General Laboratory

Re: ENSC 370 Project Physiological Signal Data Logger Functional Specifications

Nuclear Associates and

Involved brain areas in processing of Persian classical music: an fmri study

Object selectivity of local field potentials and spikes in the macaque inferior temporal cortex

Application of HDMI Cables as an MRI Compatible Single Cable Solution for Readout and Power Supply of SiPM Based PET Detectors

Procedure Manual for MRI of the Brain

Troubleshooting Guide. Prep, Scan Errors, and Artifacts

Technologist Quality Control Procedures

Phantom Test Guidance for Use of the Small MRI Phantom for the MRI Accreditation Program

Breast MR Imaging and Quality Control

Abstract. Learning Objectives 8/1/2017

Peacefully quiet. Remarkably fast.

Procedures for conducting User QA on the scanner

Experiences in ACR MRI Accreditation Vendor Nuances That Every Clinical MRI Physicist Should Know

Release Notes. Multi-Band EPI C2P. Release February 2013

The Healing Power of Music. Scientific American Mind William Forde Thompson and Gottfried Schlaug

WHY CHOOSE HITACHI? * Based on Hitachi's factory shipment records, as of end of March, Others 743 EUROPE.

Magnetic resonance imaging phase encoding:

Music Training and Neuroplasticity

TITLE: Tinnitus Multimodal Imaging. PRINCIPAL INVESTIGATOR: Steven Wan Cheung CONTRACTING ORGANIZATION: UNIVERSITY OF CALIFORNIA, SAN FRANCISCO

Research Assistant (Programmed models of sentence parsing in Chinese)

M R I Physics Course. Jerry Allison Ph.D. Chris Wright B.S. Tom Lavin M.S.M.P. Department of Radiology Medical College of Georgia

CMRRpack2. a collection of pulse sequences from the. University of Minnesota, Center for Magnetic Resonance Research (CMRR) Version: 2.

TITLE: Default, Cognitive, and Affective Brain Networks in Human Tinnitus

SMARTING SMART, RELIABLE, SIMPLE

WU-Minn HCP MEG Initial Data Release: Reference Manual

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

Datascope Spectrum OR With Gas Module 3 Monitor

MR Accreditation Programs - E. Jackson

Application Note #63 Field Analyzers in EMC Radiated Immunity Testing

Preparation of the participant. EOG, ECG, HPI coils : what, why and how

Environmental Controls Laboratory

(12) Patent Application Publication (10) Pub. No.: US 2008/ A1. (51) Int. Cl. be maintained. GRADENT SYSTEM PHYSOLOGICAL ACQUESTION CONTROLLER

Differential Representation of Species-Specific Primate Vocalizations in the Auditory Cortices of Marmoset and Cat

Philips Site Yearly Performance Evaluation Philips Achieva - Gibbons 1.5T 1-Jun-08. Table of Contents

SOTERIX MEDICAL MRI SOLUTION FOR tes and HD-tES

Open up to Extremity MRI

PV Series 850 nm VCSELs. Rise/ Fall Time Max. (nsec) 850nm GaAlAs VCSEL 1.8V, *indicates internal monitor photodiode)

Regional homogeneity on resting state fmri in patients with tinnitus

PREPARED FOR: U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland

Iterative Reconstruction with Philips idose Characterising Image Quality in Attempting to Realise its Potential

Portable in vivo Recording System

Light. Engineered for Performance- Esaote MRI, designed to make a difference.

A dedicated data acquisition system for ion velocity measurements of laser produced plasmas

The Marmoset Brain in Stereotaxic Coordinates

Premium 1.5T MRI System

GIfMI MRI user manual

Displays AND-TFT-5PA PRELIMINARY. 320 x 234 Pixels LCD Color Monitor. Features

CARE, USE AND WELFARE OF MARMOSETS AS ANIMAL MODELS FOR GENE EDITING-BASED BIOMEDICAL RESEARCH

ADNI 2 Alzheimer s Disease Neuroimaging Initiative 3T MRI Technical Procedures Manual

Standard Operating Procedure of nanoir2-s

Application Guide & Release Notes

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

In-process inspection: Inspector technology and concept

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

NeXus: Event-Related potentials Evoked potentials for Psychophysiology & Neuroscience

Supplemental Material for Gamma-band Synchronization in the Macaque Hippocampus and Memory Formation

Artifacts in Abdominopelvic MR A Pictorial Review

Tuning the Brain: Neuromodulation as a Possible Panacea for treating non-pulsatile tinnitus?

Supporting Online Material

Blending in action: Diagrams reveal conceptual integration in routine activity

Mahdad Manavi LOTS Technology, Inc.

New Generation of MEA-Systems: MEA2100-System

2019 Marmoset Community White Paper

Guide to artifacts in MRI: classification, explanation, countermeasures.

PlexBright LED Optogenetic Stimulation System

LED Display Product Data Sheet LTP-1557TBE Spec No.: DS Effective Date: 06/16/2010 LITE-ON DCC RELEASE

Investigation of time-of-flight PET detectors with depth encoding

The Ultimate Long-term EEG Monitoring System

Small animal stereotaxy

Open Your Vision Make a Smart Choice

Tuesday, Dec 3rd 10:15 to 11:00 IHE Classroom at InfoRAD at RSNA 2002.

Music Lexical Networks

Vascular. Development of Trinias FPD-Equipped Angiography System. 1. Introduction. MEDICAL NOW No.73 (2013.2) Yoshiaki Miura

NMR. picospin. Maintenance Guide

Optical Technologies Micro Motion Absolute, Technology Overview & Programming

Standard Operating Procedure II: EDS (Bruker Flat-Quad)

Jinsheng Zhang on Neuromodulation to Suppress Tinnitus.mp3

HDMI Extender via Single SC Fiber Support 3D/4K2K Up To 10Km In One Single-mode Fiber

The e ect of musicianship on pitch memory in performance matched groups

DOSE DELIVERY SYSTEM OF THE VARIAN PROBEAM SYSTEM WITH CONTINUOUS BEAM

The Widest Wide Bore in the Industry

An fmri study of music sight-reading

loss in frame rate. 3. Color flow with capability of automatically picking up color flow as a function of focal depth. 4. Color Angiography.

This is an electronic reprint of the original article. This reprint may differ from the original in pagination and typographic detail.

Fiber Type Core/Cladding (um) Rise/ Fall Time Max. (nsec) 850nm GaAlAs VCSEL 1.8V, *indicates internal monitor photodiode)

Transcription:

Anatomical and Functional Neuroimaging of the Marmoset Brain Afonso C. Silva Cerebral Microcirculation Section Laboratory of Functional and Molecular Imaging NINDS - NIH

Marmoset as a Model in Neuroscience Search performed on 10/22/2018 Search terms: marmoset neuroscience marmoset MRI

Marmosets are Lissencephalic fmri Optical Imaging Electrophysiology

Marmosets Retain the Primate Anatomical and Functional Brain Organization Human Macaque Marmoset http://www.brainmuseum.org/ G. Paxinos et al. The Marmoset Brain in Stereotaxic Coordinates, 2011 Web caret, Washington University St. Louis, MO, USA

In Vivo MRI of Marmosets Two basic setups: Anesthetized animals Isoflurane (anatomic studies) MRI compatible stereotaxic head frame Awake animals Anatomical or functional Studies Extensive Physiological Monitoring Temperature Heart Rate Pulse oximetry (MR-compatible sensor) Breathing (waveform acquired via pressure balloon) ETCO 2 (anesthetized animals only)

In Vivo MRI of Marmosets * Requires 10 cm or larger clear bore (15 cm ID or larger gradient set)

Setup for fmri of Conscious Awake Marmosets Cradle needs to be comfortable Sphinx as the natural resting position Training of animal to being restrained Acclimatize animal Non-invasive individualized helmets to hold head comfortably Equipment to support experiment RF Coil array Monitoring equipment Reward delivery devices * Requires 10 cm or larger clear bore (15 cm ID or larger gradient set)

Anatomical MRI of the Marmoset Brain in vivo T1w-MPRAGE 150 µm 3 ex vivo DTI 150 µm 3

Anatomical MRI of the Marmoset Brain T1w T2w PDw 50 25 T2*w T2-FLAIR MTR 0 Maggi P, Sati P, Massacesi L, J Neuroimmunol (2017) Absinta M, Sati P, Reich DS. Nat Rev Neurol. (2016);12:358-68. 125 µm x 125 µm in-plane resolution

7T MRI of a marmoset model of EAE 125 µm x 125 µm in-plane resolution Maggi P, Sati P, Massacesi L, J Neuroimmunol (2017) Absinta M, Sati P, Reich DS. Nat Rev Neurol. (2016);12:358-68.

Central vein in EAE and MS lesions Marmoset EAE Human MS Gaitán MI et al. Mult Scler. 2014 Slide Courtesy of Dr. Pascal Sati

Enhancing lesions in EAE and MS Marmoset EAE Triple-dose gadabutrol (0.3 ml/kg) Human MS Single-dose gadabutrol (0.1 ml/kg) Slide Courtesy of Dr. Pascal Sati pre-injection post-injection

Retrospective Lesion Detection IHC t lesion = -1 week t lesion = 0 t lesion = +1 week Lesion age can be determined based on serial MRI Potential therapeutic window! Maggi P et al. Ann Neurol. 2014

In vivo spinal cord images in marmoset EAE A C1/ C2 B L Post Ant R C D H I C3 C4 C5 2 mm C1 2 mm C2 2 mm C3 1.7 mm T1 C6 E F G T9 J C7 T1 2 mm C6 2 mm C7 2 mm C8 2.5 mm T10 Enlarged view of the spinal cord (FOV acquired: 26x34mm; 16 slices) at the cervical levels (B-G) and thoracic levels (I,J). PD-w FSE sequence 2D RARE: TR=3500 ms, TE= 15 ms, Rare factor= 2, NA=4, TA: ~ 30 min Sagittal: 0.125 x 0.125 x 0.6 mm and axial plane: 0.135 x 0.135 x 0.6 mm

In vivo spinal cord images in marmoset EAE A B C D E F G 1 mm In vivo PD-w TSE (A, B): in the EAE animal depict abnormal hyperintense signal corresponding to an area of demyelination Ex-vivo T2* GRE 3D sequence (C, D): TR=50 ms, TE= 10 ms, FA: 12, NA=32, TA: 21 min per acquisition, Total TA: ~12h (entire SC), coronal slice orientation, resolution: 70 x 200x 70 µm, FOV: 11 x 38 x 11 mm Histopathology(E-G): 5-µm thickness microtome sectioning, Luxol fast blue-periodic Acid Shif (LFB-PAS) for myelin.

fmri/ecog during visual stimulation C.-C. Hung et al Neuroimage 2015;120(10):1-11. C.-C. Hung et al J Neurosci 2015 35(3):1160-72.

Experimental paradigm for fmri of Visual System C.-C. Hung et al J Neurosci 2015 35(3):1160-72. 16 s 20 s blocks Interblocks 500 ms Reward if gazed is maintained

C.-C. Hung et al J Neurosci 2015 35(3):1160-72. Typical behavior of awake marmoset in magnet Positive reinforcement Infra-red eye-tracking Visual Stimulus

Face-selective patches along ventral visual pathway C.-C. Hung et al J Neurosci 2015 35(3):1160-72.

MRI Protocols for Marmoset Connectome Section 1: Anatomical (structural) protocol: T1, T2 and DTI Data acquired under anesthesia (e.g. isoflurane) in a single 3 hour long session Spatial resolution: 250 µm isotropic resolution for T1 and T2, and 500 µm isotropic resolution for DTI Localizer 6s AutoAlign 54s B1- mapping 27s Localizer for confirming alignment 24s MAPSHIM for up to 3 rd order shimming 82s AFI for B1+ mapping 123s MP3RAGE for T1 mapping 9.5m x 5 3RARE for T2 mapping 10.5m x 5 DTI EPI with blip up and down 2shells, 192dirs 34m FieldMap for B0 mapping 82s 0min 1min 2min 3min 5min 8min 60min 120min 155min 160min MP3RAGE 3DRARE

MRI Protocols for Marmoset Connectome Section 2: Functional protocol: rsfmri Data acquired under awake conditions in a single 3 hour long session Spatial resolution: 500 µm isotropic resolution Localizer 6s AutoAlign 54s B1- mapping 27s Localizer for confirming alignment 24s MAPSHIM for up to 3 rd order shimming 82s AFI for B1+ mapping 123s Reverse SEEPI for distortion correction 24s x 2 512 BOLD EPI with blip up and down interleaved 17m x 8 InplaneT2 144s FieldMap for B0 mapping 82s 0min 1min 2min 3min 5min 8min 10min 150min 153min 158min

Incidental Finding: Dysgenesis of the Corpus Callosum 2 0 1 8 C C (m m 2 ) 1 6 1 4 1 2 1 0 Bonnie Sonic & Luce 8 n = 24

Incidental Finding: Dysgenesis of the Corpus Callosum Normal CC Hypoplasic CC

Resting State Networks In Conscious Marmosets High Order Visual Cortex V3, V4, A19, A19DI Basal Ganglia Primary Visual Cortex Dorsomedial Somatomotor High Order Visual Cortex V4, V5, V6, FST, TE3 High Order Visual Cortex V2, A19M, V6(DM) Default Mode Network Salience Orbitofrontal Cortex Cerebellum Ventrolateral Somatomotor Frontal Pole Belcher et al., J Neurosci. 2013 33(42):16796 16804

NIH Marmoset Brain Atlas Project Version 1.0: Cortical atlas at 150um 3 (Liu, et al, 2017) Cortical Atlas

150 µm 3 80 µm 3 Multi-shell Diffusion MRI 3D diffusion-weighted spin-echo EPI Three shells [b = 2400, 4800, 7200] 6 b0 + 126 directions per shell 6.25 days / 7T MRI (Bruker 35mm linear TxRx RF Coil) MTR [T1-like, 3.5 hrs per image, 5 repetitions, 17.5 hrs] Multi-shell Diffusion MRI 3D diffusion-weighted spin-echo EPI Two shells [b = 2400, 4800] 6 b0 + 64 [b2400] + 126 [b4800] 15 days / 7T MRI (Quadrature Millipede TxRx Coil) MTR [T1-like, 10 hrs per image, 5 repetitions, 50 hrs]

Examples: Coronal Radiation A complex region with different fibers run different directions 150 um 3 150 µm 3 80 µm 3 64 µm 3

Examples: : Fibers in Occipital lobe

Examples: : Fibers in Occipital lobe Homologous across primates Marmoset Macaque

Supported by Version 1.0 Cortical Atlas + Cortical Atlas Paxinos Atlas Location-based MRI-based Connectivity-based Version 2.0 White matter & Fiber pathways atlas

Supported by AFNI Just like our old version 1.0, version 2.0 will be fully implemented in AFNI [ Easy Installation] <bash>$ @Install_NIH_Marmoset <bash>$ afni NIH_Marmoset AFNI whereami: NIH cortical atlas (v1.0) + Paxinos cortical atlas + NIH white matter atlas (v2.0)

Conclusions Non-human primates are essential animal models in biomedical research and neuroscience Marmosets have many advantages in biomedical research, particularly as a model of aging and for the implementation of genetic tools The combined use of high resolution anatomical and functional MRI will allow better understanding of functional cortical organization and study of marmoset models of neurological disorders

Cerebral Microcirculation Section Chief: Afonso Silva Research Fellow: Sang-Ho Choi Postdoctoral Fellows: Jungeun Park Cirong Liu Predoctoral Fellow: Diego Szczupak Post-bac IRTAS: Madeline Marcelle Kathy Crystal Young Lab Manager/Technician: Lisa Zhang