REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

Similar documents
REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

LM - 79 Reporting. Laboratory Information. Date of test report July 31 st, Product Information

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK Project No. G Date: October 29, 2010 REPORT NO CRT-001 TEST OF ONE LED DESK LAMP

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

Test Report. Report Number: L15159 Date: Jan 6, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Bartco Lighting 5761 Research Drive, Huntington Beach, CA

Fixture is tested with no special conditions. No seasoning was performed in accordance with IESNA LM-79. PS-AC02 CD-SN03-S2 MT-SC01-S2 2MR97 SPR-3000

Number Eight Lighting Company 526 Portal Street, Cotati, CA 94931

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

IESNA LM79: 2008 Photometric Test Report

ZipTwo LED - Zipper board with Diffuse Batwing Lens, High Output. IES File Performance Summary

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

Revolution Lighting Technologies (RVLT) 2280 Ward Ave. Docks 5&6, Simi Valley, CA 93065

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Number Eight Lighting Company 803/K2-HI-25-XX/DIM /FS-P-1-WH

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

PHONE: (303) FAX: (970) WEBSITE:

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: IRICO) 911 Denison St Markham, ON L3R 3K4 Canada

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Fuel Pump Canopy Luminaires

NVLAP LAB CODE LM Test Report. For. EiKO Global, LLC. (Brand Name: EiKO) W. 84th St, Shawnee, KS USA

Infinilux 5349 Zambrano St, Commerce, CA Electrical and Photometric tests as required by the IESNA test standards.

Photometric Test Report

Report of Test LLIA A-R01*

LED Floodlight RoHS. Model: inner box: L273*W240*H165mm master carton: L549*W485*H175mm 4PCS

Photometric Test Report

NVLAP LAB CODE:

NVLAP LAB CODE:

Report of Test LLIA

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

Product testing and evaluation to IES LM-79-08

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE 24V LED Tape Light DI-24V-BL35-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE 24V LED Tape Light DI-24V-BL28-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV50-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV24-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV20-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. INFINILINE X 120V LED Light DI-120V-INFX60

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. INFINILINE X 120V LED Light DI-120V-INFX27

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-24V-BLBSC1-30-W***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-12-BLBSC2-50-W***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-24-BLBSC2-30-W***

LightLab I N T E R N A T I O N A L

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU DI-24V-ES30-BK 3000K BLACK.

LightLab I N T E R N A T I O N A L

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE Basics 100 LED Tape Light - DI-24V-BLBSC1-63-***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. Blaze Basics 200 LED Tapelight DI-12V-BLBSC2-27-***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. Blaze Basics 200 LED Tapelight DI-12V-BLBSC2-50-***

PHONE: (303) FAX: (970) WEBSITE:

IESNA LM-79: Measurement and Test Report for Venture Lighting International Aurora Road, Suite A, Solon, OH 44139,United states

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC W 84th St, Shawnee, KS LED120WPT50KMOG-G6

American National Standard

Evaluating and Specifying LED Lighting

Guidelines for Specification of LED Lighting Products 2010

never recognized 7,307,391)

REPORT NO CRT-001h SOUND OUTPUT MEASUREMENTS ON SIX INVERTER GENERATOR SAMPLES RENDERED TO

IEC Standard for Luminaires Part 1: General Requirements and Tests, IEC Edition 8, Issued May The

Technical Report No Dated

Vaya Cove, Color. Data sheet. Philips Lighting Rev Burlington Woods Drive Burlington, MA 01803

PRODUCT FAMILY DATASHEET LEDVANCE DOWNLIGHT LED DALI

Light emitting diode standards where are we?

Transcription:

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 1345 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 142-.. Project No. G1258525 Date: May 26, 216 REPORT NO. 1258524CRT-1 TEST OF ONE LED TRACK LUMINAIRE MODEL NO. LX22-ZE13-934 LED MODEL NO. LUMILEDS Z ES DRIVER MODEL NO. LTF DA5W12C RENDERED TO: LIGHTING SERVICES INC. 2 HOLT DR STONY POINT, NY 198-192 TESTS: Electrical and Photometric tests as required to the IESNA test standard. STATEMENT OF LIMITATION: This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. AUTHORIZATION The testing performed was authorized by signed quote number Qu-694949. STANDARDS USED: IESNA LM-79-28: Electrical and Photometric Measurements of Solid State Lighting ANSI NEMA ANSLG C78.377: 215: Specifications of the Chromaticity of Solid State Lighting Products DESCRIPTION OF SAMPLE: The client submitted one production sample of model number LX22-ZE13-934. The sample was received by Intertek on May 11, 216 in undamaged condition and one sample was tested as received. The sample designation was CRT165111157-1A. DATE OF TESTS: May 25, 216 through May 26, 216. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

SUMMARY: MODEL NO. LX22-ZE13-934 DESCRIPTION: LED TRACK LUMINAIRE Criteria Light Output (Lumens) Total Power (W) Lumen Efficacy (Lm/W) Power Factor ( ) Criteria Current ATHD (%) Correlated Color Temp. (CCT-K) Color Rendering Index (CRI - Ra) CRI - R9 DUV ( ) Chromaticity Coordinate (x) Chromaticity Coordinate (y) Chromaticity Coordinate (u') Chromaticity Coordinate (v') Integrating Sphere Goniophotometer 116.3 116.2 5.4 5.39 21.5 21.6.899.95 Results 32.15 386 93.1 73.2..432.45.247.521 EQUIPMENT LIST Equipment Used LSI High Speed Mirror Goniometer Elgar AC Power Supply Sorenson DC Power Supply Yokogawa Power Analyzer Omega Thermometer M-D Building Products Digital Level NIST Luminous Intensity Standard Source NIST Luminous Intensity Standard Source NIST Luminous Intensity Standard Source NIST Luminous Flux Standard Source 2M Integrating Sphere Spectrometer System Yokogawa Power Analyzer Fluke Temperature Meter Extech Hygro-thermometer Elgar AC Power Supply Secondary Spectral Flux Standard Source Secondary Luminous Flux Standard Source Secondary Luminous Flux Standard Source Secondary Luminous Flux Standard Source Sorenson DC Power Supply Model No. Control No. 644 --- CW1251 --- XG 15-1 --- WT21 E464 DPi8-C24 M263 Smart Tool L112 NBS1322 N1427 NBS1215 N1432 96629-3 N1428 NBS1428 N1424 CDS 11 N38 WT16 E536 53II D588 445715 T155 CW1251 -- BS5186 RF5186 6836 -- BS4116 -- BS3616 -- XG 15-1 -- Last Cal. Cal. Due 5/4/216 6/4/216 5/2/216 5/2/217 5/2/216 5/2/217 4/8/216 4/8/217 12/12/214 12/12/216 12/12/214 12/12/216 12/12/214 12/12/216 12/17/214 12/17/216 5/9/216 6/9/216 12/18/215 12/18/216 5/6/216 5/6/217 1/8/216 1/8/217 1/27/216 1/27/217 1/27/216 1/27/217 1/27/216 1/27/217 1/27/216 1/27/217 Report No. 1258524CRT-1 2 of 8 Date: May 26, 216

TEST METHODS: Seasoning in Sample Orientation LED Products No seasoning was performed in accordance with IESNA LM-79. Photometric and Electrical Measurements Integrating Sphere Method A Labsphere Model CDS 11 CCD Array Spectroradiometer and two meter or ten foot sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to stabilize for at least thirty minutes before measurements were made. Stabilization procedures to LM-79 were followed. Electrical measurements including voltage, current, and power were measured using a power analyzer. The calibration of the sphere photometer-spectroradiometer system is traceable to the National Institute of Standards and Technology. Photometric and Electrical measurements Distribution Method A LSI Type C High Speed Model 644 Mirror Goniometer was used to measure the intensity (candelas) at each angle of distribution for the SSL sample. Ambient temperature was measured equal to the height of the sample mounted on the goniometer equipment. The SSL sample was operated on the client provided driver at rated input volts in its designated orientation. The SSL sample was allowed to stabilize for at least thirty minutes before measurements were made. Stabilization procedures to LM-79 were followed. Electrical measurements including voltage, current, and power were measured using a power analyzer. Report No. 1258524CRT-1 3 of 8 Date: May 26, 216

RESULTS: Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) Distribution Method Intertek Control No. CRT165111157-1A Base Orientation Base Up Voltage (VAC) 12.8 Current (ma) 49.6 Power (W) 5.39 Power Factor ( ).95 Light Output (Lumens) Lumen Efficacy (lm/w) 116.2 21.6 Intensity (Candlepower) Summary at 25 C - Candelas Angle 22.5 45 67.5 9 2616 2616 2616 2616 2616 5 1 49 11 52 1 65 11 128 11 244 12 15 6 6 5 4 5 2 4 4 4 4 4 25 1 1 3 35 4 45 5 55 6 65 7 75 8 85 9 Report No. 1258524CRT-1 4 of 8 Date: May 26, 216

RESULTS: Illumination Plots Illuminance - Cone of Light Mounting Height: 1ft Isoillumination Plot Zonal Lumen Summary and Percentages at 25 C Zonal Lumens and Percentages at 25 C Zone Lumens % Luminaire Zone Lumens % Luminaire -3 116.2 1. -1 114.1 98.2-4 116.2 1. 1-2 1.7 1.5-6 116.2 1. 2-3.4.3 6-9.. 3-4.. -9 116.2 1. 4-5.. 9-18.. 5-6.. -18 116.2 1. 6-7.. 7-8.. 8-9.. Report No. 1258524CRT-1 5 of 8 Date: May 26, 216

y RESULTS: Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) Sphere Method Intertek Control No. Base Orientation Voltage (VAC) Current (ma) Power (W) Power Factor ( ) Current ATHD (%) CRT165111157-1A Base Up 12.1 5. 5.4.899 32.15 Light Output Lumen Efficacy Correlated Color CRI CRI DUV (Lumens) (lm/w) Temperature - CCT (K) -Ra -R9 ( ) 116.3 21.5 386 93.1 73.2. CIE 31 Chromaticity Coordinate (x).432 CIE 31 Chromaticity Coordinate (y).45 CIE 76 Chromaticity CIE 76 Chromaticity Coordinate (u') Coordinate (v').247.521 ANSI C78.377 SSL Chromaticity (215 Version).46.44.42.4.38.36.34 65K 57K 5K ANSI ANSLG C78.377-215 LED QUADRANGLES - 7 STEP 45K 4K 35K 3K 27K 25K 22K.32.3.29.31.33.35.37.39.41 x.43.45.47.49.51.53 Report No. 1258524CRT-1 6 of 8 Date: May 26, 216

(mw/nm) RESULTS: Spectral Distribution Over Visible Wavelengths nm mw/nm nm mw/nm nm mw/nm nm mw/nm 35.19 46.582 57 1.549 68 1.232 355.16 465.48 575 1.577 685 1.114 36.16 47.419 58 1.616 69 1.1 365.16 475.388 585 1.654 695.896 37.15 48.44 59 1.78 7.794 375.12 485.475 595 1.774 75.74 38.1 49.564 6 1.839 71.619 385.14 495.676 65 1.95 715.541 39.14 5.789 61 1.965 72.472 395.17 55.895 615 2.29 725.41 4.21 51.983 62 2.66 73.354 45.29 515 1.6 625 2.93 735.37 41.5 52 1.139 63 2.91 74.266 415.93 525 1.22 635 2.79 745.231 42.162 53 1.259 64 2.36 75.2 425.27 535 1.313 645 1.974 755.172 43.47 54 1.36 65 1.93 76.15 435.535 545 1.42 655 1.81 765.13 44.684 55 1.435 66 1.71 77.111 445.881 555 1.471 665 1.591 775.96 45.975 56 1.495 67 1.475 78.83 455.797 565 1.521 675 1.35 Spectral Data Over Visible Wavelengths 2.5 2. 1.5 1..5. 35 4 45 5 55 6 65 7 75 8 Nanometers Report No. 1258524CRT-1 7 of 8 Date: May 26, 216

PRODUCT PICTURE: CONCLUSION The results tabulated in this report are representative of the actual test samples submitted for this report only. The data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not determined in this report. In Charge Of Tests: Report Reviewed By: Jeffrey Davis Engineering Supervisor Lighting Division Ryan Siddon Engineer Lighting Division Attachments: IES File - CRT165111157-1A Report No. 1258524CRT-1 8 of 8 Date: May 26, 216