Specification DNA Tracking Resistant ADSS Cable AC024AP6821BD0

Similar documents
TECHNICAL SPECIFICATION

Specification for Loose Tube Fiber Optic Cable (Non-Metallic, Dry Block, Figure-8) (G.652.D)

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

OPTICAL FIBER CABLE, ALL DIELECTRIC SELF SUPPORTING CABLE

Sumitomo Cable Specification SE-*RU. OFNP Rated Central Tube Cable with Optical Fibers. Issued: December 2014

SOLO ADSS Short-Span Cables, Fibers

SPECIFICATION 96F SM LOOSE TUBE, DRY CORE MINI CABLE

Optical Fibre Cable Technical Specification. Duct Cable GYFTY-24,48,72,144,216B1.3

SPECIFICATION 192F SM LOOSE TUBE, DRY CORE MINI CABLE

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS-2 HIGH PERFORMANCE OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

SPECIFICATION. Optical Fiber Cable

FREEDM Loose Tube Interlocking Armored Cables

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxMSOS DIELECTRIC HIGH PERFORMANCE OSP TUBE CABLE SERIES

Mining and Petrochemical Fiber Optic Cables

Spec No.: ZTT Revision: 2 Date: Oct 3, Designer. Senior Technical Manager. Approver. Chief Technical Engineer

Sumitomo Cable Specification SE-*RD. All-Dielectric Ribbon Cable with Fibers. Issued: April 2014

Micro duct Cable with HDPE Sheath for Installation by Blowing

Sumitomo Cable Specification SE-*DB. 100% Dry - Armored Central Tube Ribbon Cable with Fibers. Issued: January 2014

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX-2 OSP TUBE CABLE SERIES WITH GALVANIZED STEEL INTERLOCKED ARMORING

TE CONNECTIVITY <cable type> <fiber type> MM/YY SO<shop order number> XXXXX FEET

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTOX / TOD DIELECTRIC OSP TUBE CABLE SERIES

SINGLE MODE OPTICAL FIBER CABLE SPECIFICATION (ARSS)

Number of Fiber 6 Core 12 Core 24 Core 48 Core

1. General. 1. Scope. 2. Quality Assurance

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX. TCxxTP2-1 PLENUM RATED TUBE CABLE SERIES (NFPA 262) WITH GALVANIZED STEEL INTERLOCKED ARMORING

Number of Fiber 12 Core 24 Core 48 Core. Part Number

Standard FTTH Drop Cable. FTTH DROP - nb6a1/g657a1

LD Series High Performance Loose Tube Fiberoptic Cables

GUWN. Central Loose Tube Cables Universal Indoor/Outdoor, Steel Wire Armor (SWA) A/I-DQ(ZN)HBH Full Rodent Protection. Ordering Information

ADDENDUM #3. SPECIAL NOTE: Addendum #3 information shall supersede the information contained in the Contract Documents

Revision No. 4 Page No. Page 1 of 7

SUMITOMO PRODUCT SPECIFICATION. FutureFLEX TC01TPX (NFPA 262) PLENUM RATED TUBE

Number of Fiber 6 Core 12 Core. Part Number

GBRE. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

1. Scope OUTDOOR OFC-ADSS, SM(0.9) LOOSE TUBE BLACK

Detailed Specifications & Technical Data

Product Catalogue. Fibre Optic Cable

Ø 1000 * 588 mm 50 kg

Product Catalogue. Fiber Optic Assemblies & Adapters. Table of Contents General Description... 2

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation

GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information.

OCC Installation Round Messenger Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

Section 8 FIBERLIGN Hardware for Aerial FTTP Applications

TENDER SUMMARY. Tender Title:

Empowering businesses through innovative network solutions.

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

OPTICAL CABLE FIBER-LAN INDOOR

OptiSPEED LC Keyed Red to Unconnectorized, Fiber Pigtail, 0.9 mm Tight Buffer, 12-fiber Kit, Blue - Aqua (1-12)

FIBER OPTIC CABLES. Models GYXTC-8SS GJFJV

OPTICAL CHARACTERISTICS (applied to 12c MPO/MTP ) Item Parameter Reference

SECTION 4 TABLE OF CONTENTS

Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7

GYFTY TECHNICAL SPECIFICATIONS FOR GYFTY CABLE

Table of Contents. Specifying AFL Premise Optical Cables Outdoor. Enterprise. Interconnect. MicroCore. Indoor.

Non-metallic Aerial Distribution Optical Cables for FTTH Networks

OCC Installation Conduit Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

1. Scope OUTDOOR OFC-DW-(Twisted), SM (0.9) LOOSE TUBE BLACK

Our cables at: ATHENS AIRPORT PIRAEUS PORT TUNNEL IN PARIS NATIONAL PETROLEUM OIL COMPANY

Aerial Cable Installation Best Practices

OCC Installation Figure 8 Guidelines Excerpt from Optical Cable Corporation s INSTALLATION GUIDE

SPECIAL SPECIFICATION 2284 Fiber Optic Cable (Self-Supporting)

Industry solutions: Broadcast

All Dielectric Self Supporting (ADSS) Fiber Optic Cable Installation

Delaware County Community College Project # Marple Campus Renovation - Phase % Construction Documents November 23, 2011

OPTICAL FIBRE CABLE NETWORK 2004/1

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

Panduit Recommended Best Case Practice Split Fibre

Aerial Installation Guidelines for Fiber Optic Cable

Fiber Optic Patchcords & Cable Assemblies. Exclusive CD edition March 2006

SPECIFICATION. Spec No : VSS-1402-CS603B

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

RFP LC Uniboot to RFP LC Uniboot Patch cord, 2 fibres, Interconnect tight-buffered cable, LSZH

INDUSTRY SOLUTIONS: MINING

New Ultra-Density Fiber Cable Technology for FTTx and Access Markets Using New SpiderWeb Ribbon

Mid-Span Access of Loose-Tube Ribbon Fiber Optic Cable

SJOF-BS604B. Fiber Optic Splice Closure User Manual Rev.1

Triax TechInfo. Installing and pulling Fibre Optic cables

HITRONIC Optical Transmission Cable

NC-1000 INSTALLATION MANUAL NC-1000 FIBRE OPTIC CROSS-CONNECTION SYSTEM

Cable Sets. Deployable reel available. Singlemode & multimode types. MIL Conformant Tactical Cable

SPECIAL SPECIFICATION 6191 Fiber Optic Cable

MT-RJ SECURE Product Expansion Now 10 Variants of the MT-RJ SECURE Products

White Paper. Next Generation of Fiber Optic Loose Tube Cable. ABSTRACT INTRODUCTION. Stephen Martin, Product Line Manager, RCDD

OPTICAL FIBRE CABLES. for very-high bit transmission and FTTx networks

Table of Contents. Teldor Cables and Systems Ltd.

ANSI/ICEA S STANDARD FOR OPTICAL FIBER OUTSIDE PLANT COMMUNICATIONS CABLE

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Fiber Optic Cable System

Dry-Core ADSS Cable Placement

Cables for robot applications

Gear up for the future.

TELECOM SOLUTIONS SOLUTIONS CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Special Specification 6242 Special Fiber Optic Cable

1 1/2 13.5, 625 JCASS)

The FiberMark1 offers an ideal solution for

The advantages of using reduced coating diameter optical fibers (200µm) in ADSS cables for deployment in FTTx networks

Cable Installation Tips

A Comparison of Dry Versus Gel Filled Optical Cables

The World Of Professional Fiber Optics. safe flexible reliable

Transcription:

PO Box 3127 Spartanburg, SC 29304 Tel: Fax: 1 800 235 3423 1 84 433 550 Specification DNA-31734 Trackg Resistant ADSS Cable Representative 8 unit Fiber Optic Core Representative AFL-ADSS Fiber Optic Cable Bder Tape Color Coded Buffer Tube Central Strength Member Outer Jacket Aramid Yarn Inner Jacket Optical Core Span Length (ft) Condition Installation Ice Alone Wd Alone Ice and Wd NESC Light Other AC024AP821BD0 24 Corng SMF-28e+ LL Sglemode Sag / Tension Performance 1,000 Add'l Input Data Resultant Data Wd Radial Ice Load Vert. Horiz. Vector Vert. Horiz Vector Tension (mi/hr) (ches) (lbs/ft) (ft) (ft) (ft) (ft) (ft) (ft) (lbs) --- --- --- 10.0 --- --- 10.00 --- 10.0 1,580 93.0 --- --- --- --- --- 4.59 39.9 40.1 3,441 0.0 --- 0.1 --- --- --- 7.32 2.4 27.4 2,38 Standards Designed and Manufactured accordance with the followg: Cable IEEE 1222 Fiber IEC 0793, ITU-T G.5x Series Color Code ANSI/EIA 359-A, 598-A, IEC 0304 DNA-31734 10/8/2013 Version 1.2 Page 1 of 5

Approximate Cable Diameter Approximate Cable Weight Mechanical / Physical Details 15.1 mm 0.594 188 kg/km 0.12 lbs/ft Maximum Rated Cable Load (MRCL) Approximate Cable Breakg Strength 2,299 kg 5,09 lbs 3,77 kg 8,10 lbs Mimum Bendg Radius Static Dynamic 1 cm 31 cm 12 Coefficient of Lear Expansion.24E-0 1/ C 3.47E-0 1/ F Cable Modulus Initial 11.45 kn/mm² 1,0.2 kpsi Fal 10 Year 12.34 kn/mm² 1,790.4 kpsi 9.54 kn/mm² 1,383.5 kpsi Environmental Temperature Recommendations Storage -50 to +70 C -58 to +158 F Operation Installation -40 to +70 C -30 to +70 C -40 to +158 F -22 to +158 F Optical Details Attenuation Characteristics for Corng SMF-28e+ LL Sglemode fibers Max Individual 0.35 db/km 1310 nm 0.25 db/km 1550 nm 48 Fiber ADSS Core (8 - fiber buffer tubes) Fiber Unit Fiber Type Count Blue Corng SMF-28e+ LL Sglemode fibers Orange Corng SMF-28e+ LL Sglemode fibers Green Corng SMF-28e+ LL Sglemode fibers Brown Corng SMF-28e+ LL Sglemode fibers Standard Fiber Color Code Fiber No. Color 1 Blue 2 Orange 3 Green 4 Brown 5 Slate White 7 Red 8 Black 9 Yellow Total Fiber Count 10 Violet 11 Rose 24 12 Aqua 1) 2) Designs with more than 12 fibers per tube will use the standard color code and bders for identification of the fibers. Designs with mixed fiber types will have multimode or NZDS fibers the first tube(s) followed by sgle-mode fibers the last tube(s). Installation and Handlg Recommendations Installation and cable preparation procedures are outled the AFL documents listed below. Contact AFL to request copies. Recommended Installation Procedures for All-Dielectric, Self-Supportg (ADSS) Fiber Optic Cable AFL-ADSS Fiber Optic Cable Installation Video DNA-31734 10/8/2013 Version 1.2 Page 2 of 5

Installation Instructions for Installg All-Dielectric, Self-Supportg (ADSS) an AFL Telecommunications Splice Enclosure Fiber Optic Cable Receivg, Handlg and Storage. Document ACS-WI-809 DNA-31734 10/8/2013 Version 1.2 Page 3 of 5

Approximate Cable Diameter Maximum Strgg Tension (at tensioner)* Mimum Bull Wheel Diameter Strgg Sheave Diameter** Mimum Bendg Radius Cable Static (No load) Dynamic (under tension) Fiber After Installation (Static) Plastic Buffer Tube After Installation (Static) Specification DNA-31734 Quick Reference Installation Notes 15.10 mm 0.594 735 kg 1,21 lbs 10 cm 42 1 cm 24 1 cm 31 cm 12 3.8 cm 1.5 8 cm 3 * - The strgg tension is always measured at the tensioner side. In general the maximum strgg tension should be a half of the maximum saggg tension and never should exceed 20% RBS of the ADSS Cable. ** - The value dicated is for the first and last structures of the pull and is based on 40 times the diameter of the ADSS cable. Smaller diameters can be used at tangent structures. Reference AFL's stallation structions for more details. Reference AFL's "Recommended Installation Procedures for All-Dielectric, Self-Supportg (ADSS) Fiber Optic Cable" for detailed stallation structions. Reel Type Shippg Reels FL TR DR OW Tare FL TR DR OW Tare Capacity (cm) (kgs) () (lbs) (meters) (feet) Wood 147 81 71 97 200 58 32 28 38 441 4,210 13,810 Wood 18 91 91 107 20 3 3 42 573 5,40 18,500 Wood 183 91 91 107 300 72 3 3 42 2 7,000 22,90 Wood 213 8 89 104 385 84 34 35 41 849 7,000 22,90 Steel 152 81 81 97 345 0 32 32 38 71 4,140 13,580 Steel 183 91 102 107 540 72 3 40 42 1,191,90 21,940 Steel 213 114 107 130 773 84 45 42 51 1,704 7,000 22,90 FL - Flange Diameter; TR - Inside Traverse Width; DR - Drum Diameter; OW - Outside Overall Width Arbor Hole Diameter: Wood: 3-1/8 (7.9cm) Steel: 3 (7.cm) Maximum lengths shown are the longest lengths that AFL offers. Longer lengths may be possible. Ordered lengths should clude a distribution of lengths, i.e., all reels cannot be ordered at the maximum. A typical reel length distribution is as follows: 000m 7000m ~ 15% of reels 4500m 000m ~ 55% of reels 2500m 4500m ~ 25% of reels <2500m ~ 5% of reels Wood reels with flex-wrap coverg are standard. Non-returnable steel reels and/or wood laggg are available upon request. Additional reel sizes may be available upon request. Steel reels are recommended for long term storage. Reference AFL's "Fiber Optic Cable Receivg, Handlg and Storage" document for additional formation. DNA-31734 10/8/2013 Version 1.2 Page 4 of 5

The Screen Inputs for ADSS cables PLS Cad Cable Data Name: Description: AFL ADSS DNA-31734 AC024AP821BD0 Cross section area (^2) 0.277 Unit weight (lbs/ft) 0.12 Outside diameter () 0.594 Ultimate Tension (lbs) 8,10 Temperature at which data below were obtaed (deg F) 70 Outer strands Fal modulus of elasticity (psi/100) 17,904 Thermal expansion coeff. (/100 deg F) 3.47E-04 Generate Coefficients Polynomial coefficients (all stra %) A0 A1 (psi/100) A2 A3 A4 Stress-stra Creep 1,02 13,835 Core strands (if different from outer strands) Fal modulus of elasticity (psi/100) Thermal expansion coeff. (/100 deg F) Polynomial coefficients (all stra %) Stress-stra Creep A0 A1 (psi/100) A2 A3 A4 DNA-31734 10/8/2013 Version 1.2 Page 5 of 5