SLS-50 Stabilized Laser Source. User s Manual. Shineway Technologies, Inc. All rights reserved.

Similar documents
OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

Light Source. Specification & User Manual

OFI Optical Fiber Identifier User s Guide

OpticalProducts. Illuminating Your Network. Testing the World s Networks

LTS-1500 Fiber Optic Test Set Operating Instructions

OPTICAL POWER METER WITH SMART DETECTOR HEAD

OFI-400 Series Optical Fiber Identifiers. OFI-400 Series Models

VGA to DVI Extender over Fiber SET

OLP-87/87P. SmartClass Fiber PON Power Meter and Microscope

Datasheet: SimpliFiber Pro

PM-1500 / LS-1500 Fiber Optic Power Meter and Light Source Operating Instructions. Quality Fiber Optic Test Equipment

Fiber Optic Meter Fiber Optic Source

PM-240-MTP Multifiber Optical Power Meter INSTRUCTION MANUAL

VIP-35 Manual. Video Inspection Probe

Fiber Meter. Specification & User Manual

L-Band Fiber Optic Link

FTK200. Users Guide. Optical Fiber Test Kit

OP750. Multichannel Source Instruction Manual

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

900-Lumen Portable LED Projector Part #: User manual

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE

ST800K-U Optical Power Meter. User Manual V1.0

Two (2) fibers Detachable DisplayPort Extender

Compact live fiber identifier with integrated optical power meter

CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE

NS-3 RF Noise Source Operation Manual

Agilent 86120B, 86120C, 86122A Multi-Wavelength Meters Technical Specifications

AXS-200/350 OPTICAL LOSS TEST SET. part of the SharpTESTER Line LAN Applications

Options: - Master Patchcord - Launch cable - Set of optical adapters

FIBER QUICKMAP. Users Manual. Multimode Troubleshooter

Two (2) fibers Detachable DisplayPort 1.2 Extender. User s Manual for the DPFX-200-TR. Manual Contents

Fiber tester. Optical power meter XL-FM141. Optical power meter User s Manual

SK2002DA SIDEKICKER 1-IN, 2-OUT VGA-UXGA DISTRIBUTION AMPLIFIER CABLE USER S GUIDE DISTRIBUTION AMPLIFIERS

OTS-300 Express Series Power Meters/Sources and Testers

Instruction Manual. 4x1 VGA Routing Switcher Series

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

Two (2) fibers Detachable HDMI 2.0 Extender. User s Manual for the HDFX-300-TR. Manual Contents

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

Product Operation Manual

U SER S G UIDE. TS2002A Fiber Optic Test Kit

User Guide. DVI + HDCP Fiber Optic Extender DVI-7330

DA1909 COMPUTER VIDEO LINE DRIVER WITH EQUALIZATION USER S GUIDE

User Manual PS-684. HDBaseT Extender Kit 70m. All Rights Reserved. Version: UHBT70P_2016V1.2

INSTRUCTION MANUAL MUSICAL LASER LIGHT SHOW TM

DISTRIBUTION AMPLIFIER

OptEnet OC48 Regenerator Module User Manual

User Guide. HDMI Fiber Optic Extender. DVI-7350a

NT-9600 Wireless Barcode Scanner. Introduction

TC Mbps - 622Mbps FIBER OPTIC MODE CONVERTER/REPEATER (Rev A0.1) User's Manual

User Guide. Single-Link DVI Active Cable Extender. DVI-7171c

EXT-HBT70-SET_2016V1.2

FiberLink 3350 Series

Perle Fast Ethernet Fiber to Fiber Media Converter Module. Installation Guide. P/N (Rev D)

SmartCrystal Cinema Neo

Operating Instructions

User Manual TPHD-BYE. HDBaseT Extender Set 70m. All Rights Reserved. Version: TPHD-BYE_2014V1.0

INSTRUCTION MANUAL SUPER LASER

USER MANUAL. DV-HSW-41 HDMI 4x1 SWITCHER LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web

UNDER TABLE 4X1 HDMI SWITCHER

User Manual TP70P. HDBaseT Extender Set 70m. All Rights Reserved. Version: TP70P_2016V1.0

TC3005(LED/ELED/LASER) User's Manual

User Guide. HDMI Active Cable Extender. DVI-7370c

MS2540 Current Loop Receiver with RS485 Communication

Assembly Level Service Guide

Reference 150 LINEAR

OPERATOR MANUAL OSD351 FIBRE OPTIC CCTV TRANSMITTER CARD

One (1) fiber Detachable HDMI Extender

DisplayPort Extender over 2 LC Fibers

PLL2210MW LED Monitor

OTFOA-25XX SERIES ERBIUM-DOPED FIBER AMPLIFIER (EDFA)

KHT 1000C HV-Probe Calibrator. Instruction Manual

DisplayPort Extender over 2 LC Fibers

User Manual. Model 979T and 979R Digital Audio Converters

User Manual TL-2X1-HDVC 2x1 HDMI & VGA Switcher with Control All Rights Reserved Version: TL-2X1-HDVC_160630

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

Zigen ZIG-PAX. Premium Digital / Analog Audio Extender. 4K 60 Hz 4:4:4 HDCP 2.2 ZigNet, Full Web Interface and System Diagnostics

PSM-003. Micro Polarization Controller/Scrambler. User Guide

DC162 Digital Visualizer. User Manual. English - 1

User's Guide to the PROLITE-30B

22" Touchscreen LED Monitor USER'S GUIDE

HOME THEATER. HDMI Selector Switches. Vanco Part Numbers (5x1) (3x1) Technical Support

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

Contents. Instruction Manual T-Rex Page 2 of 16 Release 1.01

OTLT / OTLR 3000 Manual. L-Band Fiber Optic Link MHz INSTRUCTION MANUAL

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

Fiber Optic. Foreword. Special Tips:

Instruction Manual AVT-8710 Time Base Corrector

PXL2760MW LED LCD Monitor

RemotePoint. Navigator. User s Manual VP4150

Model: UHD41-ARC. Installation Guide

ASP-FIBRS1 User Manual

Optical Channel Analyzer

VersiVision. FVTM4BCxA-CE / FVRM4BCxA-CE MULTIPLEXER SYSTEM 4-CHANNELS DIGITALLY ENCODED VIDEO 2-CHANNELS BI-DIRECTIONAL DATA

*Prefer. 600 MHz 4K ULTRA. 60Hz, 4:4:4. over one SC-Terminated Fiber-Optic Cable EXT-DP-4K600-1SC. User Manual. Release A1

4 PORT HDMI SWITCH

TRIPLETT. PairMaster. Lan Cable Test Set. Instruction Manual

TC3301. User's Manual

MP-7424 Football Scoreboard with MP5000 Console

HD-CM HORIZON DIGITAL CABLE METER

Transcription:

SLS-50 Stabilized Laser Source User s Manual Shineway Technologies, Inc. All rights reserved.

Safety Instructions The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the like, which, if not correctly performed or adhered to, could result in personnel injury. Do not proceed beyond a WARNING sign until the indicated conditions are fully understood and met. The CAUTION sign denotes a hazard. It calls attention to an operating procedure, or the like, which, if not correctly performed or adhered to, could result in damage to or destruction of part or the entire product. Do not proceed beyond a CAUTION sign until the indicated conditions are fully understood and met. The NOTE sign information that may be beneficial during the use and maintenance of the instrument. Users should avoid looking directly into optic output of any working laser source or live fiber. And the use of microscope or magnifier should also be avoided, for the use of such devices can focus a highly intense beam onto the retina, which may result in permanent eye damage Battery: SLS-50 battery type is lithium battery. Do not take battery out without technical staff s assistance. Do not expose battery to fire or intense heat. Do not open or mutilate battery. Avoid touching the electrolyte in the battery, which is corrosive and may cause injuries to eyes, skin or damage to clothes. External Power Supply: (Optional) Power Adaptor, 5V DC/750mA Laser Radiation: To avoid serious eye injury, never look directly into the optical output of fiber optic network equipment, test equipment, patch cords or tested jumpers. Shineway Technologies, Inc. - 1 -

Always avoid looking directly into the optical output port, when the instrument is working Always put protective dust cap on the detector port when the instrument is not in use. Always avoid looking directly at unconnected end of optic fiber in testing; point the unconnected end at a non-reflective object. Shineway Technologies, Inc. - 2 -

Contents SLS-50 User s Manual SAFETY INSTRUCTIONS... 1 1. GENERAL INFORMATION... 4 1.1 SCOPE OF THIS MANUAL... 4 1.2 UNPACKING AND INSPECTION... 4 1.3 INTRODUCTION... 5 2. BASIC OPERATION... 6 2.1 FOREWORD... 6 2.2 INSTRUMENT DETAILS... 6 2.2.1 External Interfaces... 7 2.2.2 Keypad... 7 2.2.3 Indicator... 8 2.3 USE OF BATTERY... 8 2.4 CONNECTOR CLEANING... 8 3. OPERATION... 10 3.1 POWER ON... 10 3.2 CONTRAST... 11 3.3 ATTENUATION... 11 3.4 LANGUAGE SETTING... 12 3.5 REFERENCE... 12 3.6 LASER ON/OFF... 14 3.7 AUTO OFF... 14 4. CALIBRATION... 16 4.1 OPTICAL INTERFACE CLEANING... 16 4.2 CALIBRATION REQUIREMENTS... 16 5. SPECIFICATIONS... 17 6. WARRANTY INFORMATION... 18 6.1 WARRANTY PERIOD... 18 6.2 EXCLUSION... 18 6.3 WARRANTY REGISTRATION... 18 6.4 RETURNING INSTRUMENT... 18 6.5 CONTACT CUSTOMER SERVICE... 19 Shineway Technologies, Inc. - 3 -

1. General Information 1.1 Scope of this Manual Thank you for purchasing ShinewayTech instrument. Please read this manual carefully before using ShinewayTech fiber optic instrument. Always be aware of the Warning and Caution sign appearing throughout this manual. This manual contains the information necessary for proper operation and maintenance of ShinewayTech instrument, troubleshooting instructions as well as information regarding maintenance services. All ShinewayTech instruments are carefully assembled and undergo rigorous mechanical, electrical, and optical inspection prior to shipment. Beside the instrument, the package also includes a lithium battery pack, a charging/data transfer cable, a power adapter, a FC/PC flange and this user's manual. For detailed information, please refer to the packing list. Upon receiving the instrument, please check for any obvious signs of physical damage that may have occurred during shipment. Report any damage to the shipping agent or the representative of Shineway Technologies Inc. immediately. Retain the original packing materials in case reshipment is necessary. 1.2 Unpacking and Inspection This instrument has been carefully packed in accordance with standard shipping procedures. Examine the instrument for damage that may have occurred during shipment. If you find any damage or the instrument is not working, or if any of the following items are not included, please contact your representative of Shineway Technologies, Inc. If necessary, you may contact Shineway Technologies, Inc via this email: support@shinewaytech.com. Shineway Technologies, Inc. - 4 -

1.3 Introduction ShinewayTech SLS-50 can generate highly stable optical signals at multiple wavelengths to precisely measure optical link loss and identify optical fiber paired with ShinewayTech OPM-50 Intelligent Optical Power Meter. Features: 6dB adjustable power output range Automatic wavelength identification Remote reference value setting FTTx applicable USB power charging No warm-up, quick start Backlight display Over 70 hours continuous operation Pocketsize, lightweight and easy-to-use CE, FCC, FDA certificates Automatic Wavelength Identification SLS-50 can transmit digital encrypted signals through tested fiber to OPM-50 which can automatically identify input wavelength and switch to the corresponding test mode. This feature greatly reduces the workload at both ends and avoids potential error. 6dB Adjustable Power Output Range Output Power can be adjusted at minimum 0.01dB/step within a range of 6dB. Remote Reference Value Setting SLS-50 can transmit digital-encrypted signal with power parameters through tested fiber to OPM-50 as reference for precise link loss measurement even the two units are far apart. Compatible with FTTx SLS-50 can generate highly stable signals at 1310nm, 1490nm, 1550nm and 1625nm wavelength, compliant with Passive Optical Network (PON) and FTTx standards. Direct LCD Display of Output Power The power value of SLS-50 output signal can be directly displayed on its screen for easy reference. Shineway Technologies, Inc. - 5 -

2. Basic Operation 2.1 Foreword This part introduces the basic operation on SLS-50. Specific operations of each type instrument are elaborated in Chapter 3 of this manual. Please read this manual carefully for optimal operation. If you encounter any problems during operation, you are welcome to contact the technical staff of our company or representatives. 2.2 Instrument Details 1 2 Shineway Technologies, Inc. - 6 -

2.2.1 External Interfaces 1. Optical Output SLS-50 is available with FC connector (Interchangeable SC/ST). 2. USB Power /Data Port SLS-50 can be charged by external power adapter (5V DC, 750mA). 2.2.2 Keypad Power on/off Toggle between output wavelengths Toggle between mw and dbm Adjust reference value in [Reference] interface; Adjust attenuation value in [Attenuator] interface; Adjust contrast in [Contrast] interface; Toggle between working modes:, Mod & AutoID; Adjust reference value in [Reference] interface; Adjust attenuation value in [Attenuator] interface; Adjust contrast in [Contrast] interface; Toggle between functional interfaces Shift digit positions in [Reference] or [Attenuator] interface Enter functional interface Confirm Shineway Technologies, Inc. - 7 -

Turn backlight on/off 2.2.3 Indicator Charging indicator 2.3 Use of Battery SLS-50 works on lithium battery, please make sure battery is mounted properly before use. When battery is low, low battery indicator will appear on LCD. You can still use SLS-50 as long as its display on LCD is identifiable. Please charge as soon as possible when battery is low to ensure accurate measurement. Please take out the battery if SLS-50 is not in use for a long time. 2.4 Connector Cleaning Please follow the instructions below when cleaning: Turn off the instrument before cleaning. Non-compliant operation may result in hazardous radiation exposure. Turn off laser source before cleaning optical interface. Always avoid looking directly into the optical output port when the instrument is working, laser is invisible and can cause serious eye damage. Disconnect instrument from power supply before cleaning to prevent electric shock. Do not install unauthorized parts or make unauthorized adjustments on instrument. Please consult qualified professional about maintenance and repair services. Always clean optical connector before using optical power meter to ensure accurate measurement. Clean the optical connector gently with cleaning swab. Inappropriate maintenance may result in low performance or error: Distance error increases; Shineway Technologies, Inc. - 8 -

Linearity error; Extra optical power attenuation; Received optical power is beyond normal range. Shineway Technologies, Inc. - 9 -

3. Operation 3.1 Power On Press [On/Off] button and loading screen appears, see Figure 3.1. ShinewayTech SLS-50 Figure 3.1 Then it enters functional interface (The last interface before last shutdown), see Figure 3.2. -6.50 dbm Contrast Figure 3.2 Press and button to toggle between below functional interfaces: Auto Off Contrast Attenuator Lang/ 语言 Laser OnOff Setup Reference Press button to enter selected functional interface. Please see below the detailed information of each interface. Shineway Technologies, Inc. - 10 -

3.2 Contrast Press and button to [Contrast] interface, see Figure 3.3. -6.50 dbm Contrast Figure 3.3 Press button to enter the interface. Press and button to adjust contrast and press button to confirm. 3.3 Attenuation Press and button to [Attenuator] interface, see Figure 3.4. -6.50 dbm Attenuator Figure 3.4 Press button to see interface shown in Figure 3.5, Press button to shift the digit position of output power value to be adjusted; Press and button to adjust output power value. Shineway Technologies, Inc. - 11 -

-6.50 dbm Attenuator Figure 3.5 Note: 1. Attenuation adjustment is effective only when laser is on ( mark appears in the right lower corner of the screen); 2. The attenuation range is 6dB. 3.4 Language Setting Press and button to [ 语言 /Lang.] interface, see Figure 3.6. -6.50 dbm 语言 /Lang. Figure 3.6 Press button to toggle between English and Chinese interface. 3.5 Reference Press and button to [Reference] interface, see Figure 3.7. Ref :- 7.00 dbm -6.50 Reference dbm Shineway Technologies, Inc. - 12 -

Figure 3.7 In this interface you can set reference value and send it to the optical power meter on the other side of the tested fiber by enabling AutoID function (ShinewayTech optical power meter with AutoID function), which can enhance the testing efficiency and avoid potential operation fault. If you need manually adjust reference value, press interface, see Figure 3.8. Ref :- 7.00 dbm button to enter reference setting -6.50 dbm Reference Figure 3.8 Press button to shift the digit position to be adjusted; press and button to adjust the value and press button to confirm. 3.6 Setup Press and button to [Setup] interface, see Figure 3.9. Laser Off Setup Fig 3.9 press button to enter Fig.3.10 interface: Shineway Technologies, Inc. - 13 -

AutoID setup mode:manual 1310nm 1650nm 850nm Setup Fig 3.10 When point to mode, press button to switch mode of Manual and Automatic. When point to 1310nm, 1650nm or 850nm, press button to select or cancel this wavelength. Note: Manual means switch the wavelength by manually press means switch the wavelength in turn automaticly. ; Automatic 3.6 Laser On/Off Press and button to [Laser OnOff] interface, see Figure 3.9. -6.50 dbm Laser Off dbm Laser OnOff Laser OnOff Figure 3.9 Press button in current interface to turn on/off laser source. Note: Press button to toggle between, 270Hz, 1000Hz, 2000Hz and AutoID modes only when laser is on. 3.7 Auto Off Press and button to [Auto Off] interface, see Figure3.10. Shineway Technologies, Inc. - 14 -

-6.50 dbm -6.50 dbm Auto Off Auto Off Figure 3.10 Press button to enable or disable Auto Off function. Shineway Technologies, Inc. - 15 -

4. Calibration 4.1 Optical Interface Cleaning Optical interface must be always kept clean. Always put protective dust cap on when the unit is not in use, and keep the protective dust cap clean. 4.2 Calibration Requirements Calibration of the instrument is recommended every 3 years. Please contact our representatives or customer service centers for proper calibration. Shineway Technologies, Inc. - 16 -

5. Specifications Model Wavelength (±20nm) 1310/1550 850/1300 Spectrum Width Application Range Emitter Type Output Power Power Stability Output Mode Adjustment Range Adjustable Steps Auto Wavelength Identification Output Power Display Connector Power Supply Battery Life Power Saving Weight Dimensions (H W T) SLS-50 A B P V X 1310/1490/ 1550 5nm 650/1310/ 1550 Multimode/Singlemode fibers FP-LD@650,850,1300,1310,1550nm; DFB-LD@1490,1625nm 3dBm@650nm; -3dBm@850/1300/1310/1490/1550/1625nm ±0.05dB/15min; 1310/1550/ 1625 ±0.10dB/8hr@1310/1490/1550/1625nm; ±0.15 db/8hr@850/1300nm, 1Hz@650nm;,270Hz,1KHz,2KHz@850/1300/1310/1490/1550/1625nm 6dB 0.01/0.1/1dB Yes (With OPM-50) Yes FC/PC (Interchangeable SC, ST) Lithium Battery / AC Adapter Continuous operation 70 hours; Standby 250 hours Auto-off after 5 minutes idle 315g (0.69 lbs) 177 80 44mm (6.97 3.15 1.73 inch) * Specifications subject to change without notice Shineway Technologies, Inc. - 17 -

6. Warranty Information 6.1 Warranty Period All ShinewayTech products are warranted against defective material and workmanship for a period of one (1) year from the date of shipment to the original customer. Any product found to be defective within the warranty period would be repaired or replaced by Shineway Technologies Inc free of charge. In no case will Shineway Technologies, Inc liabilities exceed the original purchase price of the product. 6.2 Exclusion The warranty on your equipment shall not apply to defects resulting from the following: Unauthorized repair or modification Misuse, negligence, or accident Shineway Technologies, Inc. reserves the right to make changes to any of its products at any time without having to replace or change previously purchased units. 6.3 Warranty Registration A warranty registration card is included with the original shipment of equipment. Please take a few minutes to fill out the card and mail or fax it to the local Customer Service Center of Shineway Technologies, Inc. for your product warranty activation. 6.4 Returning Instrument To return instrument for yearly calibration or other purposes, please contact the local Customer Service Center of Shineway Technologies, Inc to obtain additional information and a RMA (Return Materials Authorization) number. And describe brief reasons for the return of the equipment to help us offer you efficient services. To return the instrument in the case of repair, calibration or other Shineway Technologies, Inc. - 18 -

maintenance, please note the following: Be sure to pack the instrument with soft cushion like Polyethylene, so as to protect the shell of the instrument. Please use the original hard packing box. If you use other packing material, please ensure at least 3 cm soft material around the instrument. Be sure to correctly fill out and return the warranty registration card, which should include the following information: company name, postal address, contact, phone number, email address and problem description. Be sure to seal the packing box with exclusive tape. Be sure to ship to your representative or agent of Shineway Technologies, Inc in a reliable way. 6.5 Contact Customer Service Please check our web site (www.shinewaytech.com) for updates to this manual and additional application information. If you need technical or sales support, please contact local Shineway Technologies Customer Service. Shineway Technologies (China), Inc.: Address: Fl.7, Zhongtai Plaza, No.3 Shuangqing Rd, Haidian District, Beijing, China Postal code: 100085 Tel: +86-10-62953388 Fax: +86-10-62958572 Email: support@shinewaytech.com WEB: www.shinewaytech.com THANK YOU FOR CHOOSING SHINEWAY TECHNOLOGIES! Shineway Technologies, Inc. - 19 -