VIDEO DOOR PHONE CAV-51M

Similar documents
VIDEO DOOR PHONE. Model No. APV-4PM

User Manual Wide Color Video Phone

User Manual Color video door phone

User Manual Color video door phone

User Manual Color Video Door Phone

User Manual. Color video door phone CDV-70P PM0770P Printed In Korea /

User Manual. Color video door phone CDV-40Q

User Manual. Fineview Video Phone CDV-43MH/CDV-43MH(M)

DOOR STATION. .in.ua.

UTP TRANSMITTER & RECEIVER SUT-80/SUR-10 USER S MANUAL ENGLISH

KCV-J351 MANUAL DIGITAL COLOR VIDEOPHONE. Warranty. Warranty Card. To receive after service, have the following ready before you contact our branches.

LCD MONITOR. 27 Wide LED Monitor User Manual. User Manual P276L

Enterview 2 / Enterview 2V 4 WIRE VIDEO DOORPHONE SYSTEM

PNP300 / PNP300UN / PNP350

PLL2210MW LED Monitor

DVI-D Fiber Optic Cable

HAND-FREE COLOR VIDEO DOORPHONE. Installation and Operation Manual

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

Warning & Cautions. Warning. Cautions

PLL1920M LED LCD Monitor

Jinyoung Contech Co., Ltd.

Installation Guide VL-MV10. Model No.

PL2410W LCD Monitor USER'S GUIDE.

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

DISTRIBUTION AMPLIFIER

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

Proximity Card Reader. User s Manual

MC14 MC15 MC21 72-MC COLOR MONITOR. Product Implementation Standard No.:Q/WP :QB/

USER MANUAL. 27 Full HD Widescreen LED Monitor L270E

USER MANUAL. 28" 4K Ultra HD Monitor L28TN4K

Characteristics of DS p.03. Function of DS p.04

Table of Contents. 1. Safety Use. 2. General Description. 3. Connection Diagram. 4. Operations and Management. 4.1 Display Status. 4.

KCV-A374SD / D374SD MANUAL

ACCESSORIES MANUAL PART NUMBER: TNP500. Universal Tilt N Plug Interconnect Box USER'S GUIDE

VITEK VTM-TLM191 VTM-TLM240

OWNER S MANUAL MOTORIZED 7 WIDE TFT LCD COLOR MONITOR CNT-701

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

May result in personal injury or property loss. Indicate the behaviors that must be prohibited

Operating Instructions

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 PNP202. Interconnect Box USER'S GUIDE

LIGHT COPILOT II. elationlighting.com Internet:

28 & 32 & 40 & 55 & 65 & 84-INCH TFT-LCD 4K MONITOR

Proximity Card Reader. User s Manual

USER MANUAL Full HD Widescreen LED Monitor L236VA

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

Instruction Manual Digital Wireless Intercom SAMCOM FTAN20AA

PXL2760MW LED LCD Monitor

PNP300 & PNP350 POP N PLUG SLIM INTERCONNECT BOX USER S GUIDE

Broadcast A/V Division VAC-HT12-KIT. 4K/UHD/HD/SD HDBaseT Extender Kit Video, Power, and Control over one CAT cable. User Manual

RT AUDIO RETRACTABLE CABLE

RT USB RETRACTABLE CABLE

SM-10 SAT Level Meter User s Manual

VT VGA TFT NEMA 4/12 Flat Panel Monitor. User s Guide

Caller Display 1000 User Guide

New Multi Function Controller

Electric Motorized Projection Screen PowerMax Tension Series

User Guide. Centrex Recording Interface

TFT-LCD Color Monitor FS-L4201C

TABLE OF CONTENTS Important Safety Instructions Package Content Setting Up the Display Trouble shooting Specifications Product Dimensions

SAFETY WARNINGS AND GUIDELINES

RT USB RETRACTABLE CABLE

CS x1 RS-232 Computer Controlled Video Switcher. Instruction Manual

4, 8, 16 Port VGA and Audio Extender / Splitter with Audio over Single CAT5

Starling Tab-Tension 2 Series

ACCESSORIES MANUAL PART NUMBER: PRODUCT REVISION: 1 TNP100. Tilt N Plug Interconnect Box USER'S GUIDE

CU103 User Manual. Contents

AUTO - SCANNING WITH DIGITAL CONTROL LCD COLOR MONITOR FS-L1903C. User manual (Rev.01) SMITHS HEIMANN

DMX LED light effect with 4 lenses

Electric Wall/Ceiling Projection Screen Saker Plus Series User s Guide

TP VGA/COMPONENT+ AUDIO TWISTED PAIR (UTP) TRANSMITTER

User manual S19C150N S19C150F S20C150FL S22C150N

Owner s Manual. TFT-LCD TV High Brightness & Contrast NICAM/A2 Stereo Sound MODEL: L15SV6-A0, L17LV6-A1,L20AV6-A0 L17L6A-G1,L20L6A

HongZhao Innovation Electronic Co., Ltd. Wireless Video Door Phone

USER MANUAL. 27" 2K QHD LED Monitor L27HAS2K

Wireless Video Door Phone

LINK-MI LM-WHD05B. Wireless HDMI AV Transmission System. User Manual

FOREST SHUTTLE S / L / M RECEIVER

CNK JR. SERIES CABLE-NOOK JR. TABLETOP INTERCONNECT BOXES USER'S GUIDE

CONTENTS 8 ACCESSORIES 13 9 TROUBLE SHOOTING AND ADVICE SPECIFICATIONS BATTERY USAGE CAUTION 13

32LD9800TA 37LD9800TA

DA VGA Line Receiver User s Guide

2.4 GHz WIRELESS SURVEILLANCE SYSTEM

SyncMaster 153V/173V/152V/172V/193V/192V/153S/173S/153B/173B

CNK221 CABLE-NOOK JR. INTERCONNECT BOX USER S GUIDE

HDMI 1.4 OVER SINGLE CAT5/6/7 EXTENDER WITH BI-DIRECTIONAL IR and RS232 TRANSMITTER & RECEIVER AT-HD4-100SR

CNK221/241/261/321/341/361 Cable-Nook Jr. User s Guide

Subwoofers ENGLISH FRANCAIS SPANISH DEUTSCH OWNER S MANUEL MODE D EMPLOI MANUEL DEL USUARIO BEDIENUNGSANLEITUNG

Thank you for purchasing SEIKO SHOOTING TIMER KT-401. Before using your SEIKO SHOOTING TIMER, please read this manual carefully for its proper use

21.5-INCH VALUE TFT-LED MONITOR SM-F212

Studio 300/400 Monolight with Built-in R2 2.4GHz Radio Remote System

4K LED MONITOR 430LED4K & 550LED4K INSTRUCTION MANUAL. Please read this manual thoroughly before use, and keep it handy for future reference.

Table of Contents Precautions... 2

ARS x4 MATRIX SWITCHER Instruction Manual

Important Safety & Warning Precautions

User Manual. Tensioned Screens. Website: Tel:

Led Dynamic DMX Tri Curtain Manual

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

USER MANUAL Full HD Widescreen LED Monitor L215IPS

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

1. Safety precautions (Must Read)

Transcription:

VIDEO DOOR PHONE CAV-51M 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133 Web site : www.commax.com Printed In Korea/ 2010.0 4.101 Thank you for purchasing COMMAX products. Please carefully read this User s Guide (in particular, precautions for safety) before using a product and follow instructions to use a product exactly. The company is not responsible for any safety accidents caused by abnormal operation of the product.

Table of Contents Warnings and caution Features & Specifications 2 4 Part Name & Function Multi Entry Panel Calling Sub unit calling (Intercommunication) Guard station or external area calling Call/ Talk duration Setting In-House unit as a Master and Sub Unite Chime sound Changing and initialization of the password Opening the entrance of a Multi-entry Panel With Password Wiring System diagrm 5 6 6 6 7 7 8 8 9 10 11 1

Warnings and caution Make sure to follow the instructions to prevent any danger or property losses. It indicates prohibition. Warning Death or serious injury is expected. It indicates prohibition of disassembly. It indicates prohibition of contact. It indicates dos and don ts. It indicates that the plug should be pulled out from the socket. Warning Do not put the plug in the socket simultaneously. It may generate abnormal heat or cause a fire. Do not connect to other products while in use. It may cause breakdown. Do not forcibly bend the cord or put a heavy object on the product. It may cause a fire. Do not use water, thinner or a detergent used to wash oil products when you wash the exterior. Make sure to wash it by using a dry cloth to prevent any breakdown or electric shock. Do not install the product in a humid place. It may cause an electric shock or a fire. Do not forcibly pull out the cord from the socket. If the cord is damaged, it may cause a fire or an electric shock. 2 Do not put the plug in the socket with a wet hand. It may cause an electric shock. Do not disassemble, repair or modify the product. It may cause a fire, an electric shock or an injury due to malfunction of the product. Do not use AC circuit breaker. It may cause an electric shock.

Warnings and caution It indicates prohibition. Caution An injury or property losses are expected It indicates prohibition of disassembly. It indicates prohibition of contact. It indicates dos and don ts. It indicates that the plug should be pulled out from the socket. Caution If the socket holes are larger than normal, do not put the plug. It may cause an electric shock or a fire. Make sure that dust or foreign substances are not gathered on the product. Make sure to prevent foreign substances from entering the product. It may cause a breakdown. Do not put a heavy object on the product. It may cause a breakdown. Do not disassemble or give an impact to the product. Avoid direct rays of the sun or heating devices at a time of installation. Install the product in a flat and stable place. Otherwise, it may not function properly. Pull the plug if the product is not used for a long time. If the product generates strange sound, make sure to pull the plug immediately and contact Commax service center. 3

This is a DC type Color Video phone. It can add up to a maximum of 2 sub-units in each residence and is a surface mount type videophone that connects to a guard station or an external area. Its functions include Door release and Room-to-room call. 1. Features 1. DC type Color video phone 2. When installing only 1 master unit, power is supplied from a Floor Distributor without an additional power supply. 3. Sub-monitors need an extra power source. 4. 5 TFT LCD Monitor 5. 3 buttons : Guard station call, Door release and Extension call 6. COMMAX chime (Sol, Mi, Do) is the ring tone that sounds from Multi Entry Panel. Ding-Dong sounds from an individual door when there is a call. 7. Door release 8. 6 wires UTP Cable (CAT.5) including a power source. 2. Specifications ITEMS CAV-51M Wiring Floor distributor: 6 wires(talk2, DATA1, POWER1, VIDEO1, GND1) Power Voltage DC24V~28V/ 5A (supplied from Floor Distributor) - an extra power is required for Sub units Transmission Method Full duplex Screen Dimension Power 5 TFT LCD Stand by : 60mA requirements Maximum operation : 500mA Distance Between Floor Distributor UTP (Ø0.5) range and In-house uni 50m 4

3. Parts Names & Functions No Details No Details 1 Handset 7 Color Control 2 LCD Screen 8 Contrast Control 3 Extension call button and a Lamp 9 Video brightness control 4 Guard station call button and a Lamp 10 Call volume control 5 Door release button and a Power Lamp 11 Speaker 6 Power switch This is an in-house unit that is a Color videophone. Up to 4 residences are connectable with a single Floor distributor through a Building Distributor connected with the Multi Entry Panel. Each residence can add 2 sub-units, which comes to 3 units in total including a master unit. 5

4. Multi Entry Panel Calling 1. When receiving a call from the Multi-Entry Panel, you will hear the COMMAX chime and the image of the visitor will be shown on the screen 2. Pick up the handset to initiate conversation. 3. When opening the door of the Multi Entry Panel during a conversation, Press the Door release button and the entrance will open. (The call conversation is ended right after the release of the door) 4. When conversation is over, hang up the handset. 5. Sub unit calling (Intercommunication) 1. Pick up the handset and, press the Extension call button to make a call to the sub unit. 2. When the sub unit responds, conversation occurs. (Calling both the Extension and Master unit is possible) * When calling the Guard station with another unit or while talking with the other Extension, another in-house unit cannot make a call. 3. While talking with another extension unit and an incoming call from the Multi-Entry- Panel arrives, You have 30 seconds to answer the call from the Multi-Entry panel by pressing the hook switch of CAV-51M once on the extension unit (only one extension can have a conversation with Multi-Entry panel at a time) 6. Guard station or external area calling 1. Pick up the handset and press the Guard call button to call the Guard Station. 2. When the guard station responds, conversation can occurs. * The Guard station unit does not have an outgoing calling function, it can only receive calls) * If the Guard unit is on the line with another residence or Multi entry unit, you will hear a busy tone) 6

7. Call / Talk duration This is applied to all calls and conversation. 1. Calling time lasts for 30 seconds. 2. Talking duration lasts for 60 seconds. 8. Setting In-House unit as a Master and Sub Units. - This setting should be set by the Multi Entry Panel which should be connected to channel 1 - When a single unit is installed, the setting should be set as a master unit. (In case more than 2 units are installed, one should be set as a master, and the rest should be set as slave units.) - The Door Release and Extension call button on the unit run as a selection to the master or slave in this mode. 1) Setting Master 1) Set the ID as 0 on the Multi Entry Panels that should be connected to channel 1. - The default of all Multi Entry Panel is assigned to 0 2) While picking up the handset of an in-house unit, press the extension cal button and the door release button at the same time. 3) You can communicate with the Multi Entry Panel while the resident s number is displayed on it. When the ->M message is displayed on the Multi Entry Panel when you press the Door Open button on an in-house unit. 4) Then, register the ID of the shown residence, and press button to hear a sound of completion. 5) The registration is complete when you hang up the handset. (Repeat this process for other residences) 6) Set the ID as 1 on the multi-entry panel after completing the registration. 7

1) Setting Master 1 Set the ID as 0 on Multi-Entry panel which shold be connected to chanel 1 - The default of all Multi Entry Panels is assigned to 0. 2 While picking up the handset of an in-house unit, press the extension call button and the door release button at the same time. 3 You can communicate with the Multi Entry Panel while the resident s number is displayed on it. 4 When the *** -> M message is displayed on the Multi Entry Panel when you press the Door Open button on an in-house unit. 5 Then, register the ID of the shown residence, and press button to hear a sound of completion. 6 The registration is complete when you hang up the handset. (Repeat this process for other residentes) 7 Set the ID as 1 on the Multi-Entry panel after completing the registration 9. Chime Sound Chime will sound when calling an individual door bell with audio type. 10. Changing and initialization of the password. 8 Note) the doors do not open by default password 1234 Only after changing default Password, can you use this function 1) Initialization for the password (only the password for the Master unit is initialized) 1 Shut off master unit and turn it on again while holding the Extension call button and Door release button at the same time for 3 seconds. 2 The password will initialize to 1234 when the LCD stops blinking. Note : Default password: 1234 2) Changing Resident Password 1 Hold Residence Number and button for 2 seconds and release when LCD stops blinking. 2 Enter Current password. 3 Hold button for 2 seconds and release when the LCD stops blinking. 4 Enter New Password with 4 digits on Multi Entry Panel displaying NEW PW : message. 5 Hold Key button for 2 seconds and release when the LCD stops blinking. 6 Repeat New password to confirm it. 7 Hold button for 2 seconds and release when the LCD stops blinking.

11. Opening the entrance of a Multi-entry panel with password Note : The doors do not open by default password 1234 Only after changing default Password, can you use this function. 1) Open the entrance with resident password. 1 Enter the resident number and 2 Enter the PIN number and the button button The door opens with the OPEN message will be displayed on the LCD screen. 2) Open the entrance with Building password. 1 Enter 9900 and button 2 Enter the Building password and the button The door opens with the OPEN message display on the LCD screen 9

12. Wiring and System diagram 1. Wiring 2. Wiring method - Please pay attention to the polarity of the wires. Units will not work properly when mis-wired. - The Power of the Master unit is supplied from the Building distributor without an additional power supply, but additional sub units requires a separate a power source. (There is no power line connection between Master unit and Sub units) 10

3. Diagram 11

12