HIGH VOLTAGE SWITCH PERFORMANCE OF THE EIMAC X-2159 TETRODE ABSTRACT

Similar documents
TEST WIRE FOR HIGH VOLTAGE POWER SUPPLY CROWBAR SYSTEM

w. R. Scarlett, K. R. Andrews, H. Jansen

RADIOGRAPHIC PERFORMANCE OF CYGNUS 1 AND THE FEBETRON 705

GA A26497 SOLID-STATE HIGH-VOLTAGE CROWBAR UTILIZING SERIES-CONNECTED THYRISTORS

THE LIQUID METAL PLASMA VALVE CLOSIN"G SWITCH. John R. Bayless Hughes Research Laboratories 3011 Malibu Canyon Road Malibu, California

KLYSTRON GUN ARCING AND MODULATOR PROTECTION

Fig. 1. Hawk switch/load vacuum section in the standard configuration.

A Comparison of the Temporal Characteristics of LCS, LCoS, Laser, And CRT Projectors

Svetlana 3CX10,000A7/8160

REPORT DOCUMENTATION PAGE

K800 RF AMPLIFIER TUBE UPGRADE

Thyratrons. High Energy Switches. Features. Description

STUDIES OF ENHANCED EDGE EMISSION OF A LARGE AREA CATHODE *

A Unique Power Supply for the PEP II Klystron at SLAC*

4.9 BEAM BLANKING AND PULSING OPTIONS

RATE-ADAPTIVE VIDEO CODING (RAVC)

AFRL-RY-WP-TR

IOT OPERATIONAL EXPERIENCE ON ALICE AND EMMA AT DARESBURY LABORATORY

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

American Power Design, Inc.

AMERICAN NATIONAL STANDARD

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

THE CARE AND FEEDING OF CROWBAR THYRATRONS

E2V Technologies CX2668A, CX2668AX Air-Cooled, Hollow Anode, Two-Gap Metal/Ceramic Thyratrons

SCR Characteristics Trainer NV6530 Learning Material Ver 1.1

Applying LaPO 4 Phosphor via Spinning for BetaPhotovoltaic Devices

UNITED STATES AIR FORCE RESEARCH LABORATORY

About vacuum power tubes.

Continued Development of the Look-up-table (LUT) Methodology for Interpretation of Remotely Sensed Ocean

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency

INSTRUCTION BOOK. A Digital Readout for Real World Analog Measurements

4617 Super Power Triode

CX1725W Liquid Cooled, Hollow Anode Two-Gap Metal/Ceramic Thyratron

Computational Studies of X-ray Framing Cameras for the National Ignition Facility

Search Strategies for a Wide-Field Electro-Optic Sensor

Operating Experience and Reliability Improvements on the 5 kw CW Klystron at Jefferson Lab

29.1 PULSED POWER BIBLIOGRAPHY. R. L. Druce and A. H. Guenther Air Force Weapons Laboratory (CA) Kirtland AFB Albuquerque, NM 87117

Valves Artzt circuit (a.k.a. the SRPP and the µ-follower)

Protecting ETO Alpha 76A Amplifiers

Processing the Output of TOSOM

The Knowledge Bank at The Ohio State University. Ohio State Engineer

A Look-up-table Approach to Inverting Remotely Sensed Ocean Color Data

Overview of All Pixel Circuits for Active Matrix Organic Light Emitting Diode (AMOLED)

INSTRUCTION BOOK. A Digital Readout for Real World Analog Measurements

THE EXPLOSIVE PULSED POWER TEST FACILITY AT AFRL

Australian Technical Production Services

DESIGN AND PERFORMANCE OF THE MARX GENERATOR FOR THE DARHT SECOND AXIS ELECTRON INJECTOR*

SECTION I INTRODUCTION

GA A23551 THE PERFORMANCE OF THE 8.4 MW MODULATOR/REGULATOR POWER SYSTEMS FOR THE ELECTRON CYCLOTRON HEATING FACILITY UPGRADE AT DIII D

16 Stage Bi-Directional LED Sequencer

System Troubleshooting for

RF Power Generation II

4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER. 6. AUTHOR(S) 5d. PROJECT NUMBER

CERN EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH. A 50 Hz LOW-POWER SOLID-STATE KLYSTRON-MODULATOR

Nutube.US. 6P1 Evaluation Board. User Manual

V6118 EM MICROELECTRONIC - MARIN SA. 2, 4 and 8 Mutiplex LCD Driver

American National Standard for Lamp Ballasts High Frequency Fluorescent Lamp Ballasts

Solid State Modulators for X-Band Accelerators

TOSHIBA Industrial Magnetron E3328

A HIGH POWER LONG PULSE HIGH EFFICIENCY MULTI BEAM KLYSTRON

Lecture 17 Microwave Tubes: Part I

4664 Power Tube. UHF High Power Tetrode Amplifier Tube GENERAL DATA

MATE3 Owner s Manual Addendum

Simulation of DFIG and FSIG wind farms in. MATLAB SimPowerSystems. Industrial Electrical Engineering and Automation.

The. Radio History. How and Why Quincy, IL Became the Digital Capitol of the World. By Tom Yingst

TECHNICAL SPECIFICATION Multi-beam S-band Klystron type BT267

Technical Article. TD350 IGBT driver IC including advanced control and protection functions. Introduction. Device description

Specifications. Mechanical Information. Mass (grams) Dimensions (mm) 15 x 75 Housing. Anodised Aluminium Isolated Body

Analog Circuits Prof. Nagendra Krishnapura Department of Electrical Engineering Indian Institute of Technology, Madras. Module - 04 Lecture 12

HY-32 Deuterium Triode Thyratron

Atlas SCR. User Guide. Thyristor and Triac Analyser Model SCR100

REPORT DOCUMENTATION PAGE

Pulsed Klystrons for Next Generation Neutron Sources Edward L. Eisen - CPI, Inc. Palo Alto, CA, USA

1 Power Protection and Conditioning

AN555 APPLICATION NOTE AUTOMOTIVE PROTECTION WITH THE RBOxx SERIES

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

THERMIONIC GUN CATHODE-GRID ASSEMBLY TEST PROCEDURE

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

IOT RF Power Sources for Pulsed and CW Linacs

CR7000. CRT Analyzer & Restorer. Easily Test And Restore CRTs With The Most Complete Tests Available For Added Profit And Security.

CATHODE-RAY OSCILLOSCOPE (CRO)

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

DSO138mini Troubleshooting Guide

LM MHz RGB Video Amplifier System with OSD

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

Emcore SITU2831 Externally Modulated RF Amplified Fiber Optic Transmitter and SIRU3000 Fiber Optic Receiver

Experimental Results of the Coaxial Multipactor Experiment. T.P. Graves, B. LaBombard, S.J. Wukitch, I.H. Hutchinson PSFC-MIT

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

RICHLAND COLLEGE School of Engineering Business & Technology Rev. 0 W. Slonecker Rev. 1 (8/26/2012) J. Bradbury

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 4, July 2013

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

Agilent Technologies 54522A

The Venerable Triode. The earliest Triode was Lee De Forest's 1906 Audion.

EA350. Generator Automatic Voltage Regulator Operation Manual

A U D I O, I N C

RF plans for ESS. Morten Jensen. ESLS-RF 2013 Berlin

Projection Television Troubleshooting. Training Manual KDP-57XBR2. RA-3/3A, RA-4/4A, RA-5A, RA-6 Chassis. Practical Troubleshooting Tips

Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science Introductory Digital Systems Laboratory

Transcription:

HIGH VOLTAGE SWITCH PERFORMANCE OF THE EIMAC X-2159 TETRODE by Bobby R. Gray High Power Component & Effects Section Techniques Branch Surveillance Division Rome Air Development Center Griffiss Air Force Base, NY ABSTRACT High Power Tetrodes designed as RF power amplifiers often times have excellent characteristics that enhance their performance when used as switch tubes. This paper reports on the test and evaluation of one such high power tetrode, the EIMAC X-2159. This tube has a design anode dissipation rating of 1.25 megawatts average power and the cathode grid and screen have very substantial ratings. The objective of the test was to determine the maximum achievable pulsed power with this tube. One main data, point of interest was a pulsed current of 1000 amperes - 10-20 microseconds and 50 KV hold-off. This point has been achieved. Further testing is planned to fully evolve the limits. Problems encountered included secondary emission causing the load pulse to increase in length as if it were a function of primary'emission from grid. Other features of the tube to be discussed will be the ability to interrupt a faulted load current pulse and its overall operating stability. Introduction Purpose of this program is to determine the maximum power handling ability of the EIMAC X-2159 Tetrode. The maximum reliable anode voltages and current are to be determined over a number of pulse lengths and repetition frequencies. Of particular interest is pulsewidth up to 1 (one) millisec at duty factor up to 0.01. Mode of operation is to seek the maximum pulse current for the minimum anode voltages by varying the load resistance, grid voltage, screen voltages and filament voltage. No attempt is being made to exercise the tube as a regulator or be modulated with any waveform other than a rectangular pulse. Because of some of the problem areas identified with secondary electron emission, these types of operation must be considered in greater detail. IC4-l

Report Documentation Page Form Approved OMB No. 0704-0188 Public reporting burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to a penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE NOV 1976 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE High Voltage Switch Performance Of The Eimac X-2159 Tetrode 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) High Power Component & Effects Section Techniques Branch Surveillance Division Rome Air Development Center Griffiss Air Force Base, NY 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR S ACRONYM(S) 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release, distribution unlimited 11. SPONSOR/MONITOR S REPORT NUMBER(S) 13. SUPPLEMENTARY NOTES See also ADM002371. 2013 IEEE Pulsed Power Conference, Digest of Technical Papers 1976-2013, and Abstracts of the 2013 IEEE International Conference on Plasma Science. Held in San Francisco, CA on 16-21 June 2013. U.S. Government or Federal Purpose Rights License. 14. ABSTRACT High Power Tetrodes designed as RF power amplifiers often times have excellent characteristics that enhance their performance when used as switch tubes. This paper reports on the test and evaluation of one such high power tetrode, the EIMAC X-2159. This tube has a design anode dissipation rating of 1.25 megawatts average power and the cathode grid and screen have very substantial ratings. The objective of the test was to determine the maximum achievable pulsed power with this tube. One main data, point of interest was a pulsed current of 1000 amperes - 10-20 microseconds and 50 KV hold-off. This point has been achieved. Further testing is planned to fully evolve the limits. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT SAR a. REPORT unclassified b. ABSTRACT unclassified c. THIS PAGE unclassified 18. NUMBER OF PAGES 8 19a. NAME OF RESPONSIBLE PERSON Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18

IC4-2 Considerable data has been taken to date but unfortunately a mechanical failure in the regulator for the high voltage supply has caused a delay in achieving the maximum levels the tube is conceptually able to handle. Enough data has been taken to highlight some particular problem areas to be considered in using the tube. These will be covered in detail. Grid Circuit The basic pulser scheme shown in Figure 1 utilizes a 4CW100000E Tetrode driven by a Caber Electronics Mod 604 Pulser. It would seem that it is a bit 11 overki11 11 to use a tube which has an average anode dissipation rating of 100 kilowatts to drive a tube which has a anode rating of 1.25 megawatts. Although a smaller tube should be able to provide adequate drive, a 4CW100000E was used because of uncertainty of the maximum drive current required to keep a net positive grid current flow during the pulse. The driver tube is run as a cathode follower with its bias supply and screen voltage supply floating at some voltage above ground but referenced to its 1 cathode. Isolation for the Caber pulse driver is provided within the unit itself which has internal floating circuitry of bias supply current for isolation of either output level to 2500 VDC. Figure 2 is a photograph of the tube in the test set. Grid Circuit Regulation Realizing that it was essential to maintain a low grid input impedance in order to maintain stability under any drive condition, the driver stage for this test was initially loaded with 50 ohms of low inductance type resistance. Operation appeared to be satisfactory until screen voltage of about 1500 volts and grid voltage 200-300 were reached. At these levels the anode current pulse tends to stretch out and the grid current reverses to a negative direction at the end of the pulse. Stretching out of the anode current pulse usually is caused by primary emission from the grid because of overheating. Under the test condition however, the average power supplied to the grid was only about 20 watts; far below maximum rating of tube grid. Apparently at the point w'here the screen voltage was beginning to affect the grid current, the secondary electrons were beginning to be accelerated away from the grid by the screen. In the presence of the normal forward drive voltage the negative grid current was suppressed but at the end of the voltage pulse flat top, the grid goes toward cutoff and in doing so passes through the region where secondary voltages are easily emitted. These secondaries thus created a new driving pulse that kept the tube turned on. At this point, the driver stage was loaded with a total of 20 ohms resistance in parallel with the grid. The negative grid current spike was greatly reduced and plate current stretchout was virtually eliminated. Figure 3 shows the effect of screen voltage at 1700 volts prior to extra loading of the grid.

IC4-3 Without some way of regulating the bias voltage to the tube grid intercept electrons, the bias voltage will increase in proportion to the intercepted positive grid current. One could use (1) sturdy zener diodes (2) a fixed resistor drawing heavy current at all times (3) an electronic shunt regulator (4) a simple, yet rugged, soft 11 regulator, able to absorb any increased voltage arising from grid interception yet not draw heavy shunt currents when the tube is not pulsing. A simple form of the soft type of regulator was found in a series of varistor disks made by General Electric. Six (6) each of the 150 VDC disks rated at 10 watts each were connected in series for a continuous current of 20 milliamperes of bias supply current when the X-2159 was not pulsing. Anode Circuit Transient Suppression A problem of considerable magnitude was that of controlling the induced voltage in the power supply-anode-cathode circuit which includes the energy storage capacitor bank. The rate of rise of current in the anode circuit is in the order of 1000 amperes/microsecond. Because of an excessive amount of inductance in the HV lead connecting the anode to the capacitor bank and its return path, the anode plate voltage and current had a poor transient response. Connecting the tube to the load capacitor bank with coaxial cable and adding an additional snubbing network directly at the tube anode helped make the transient response of the system manageable. Using the open bus type system, the anode voltage would rise to several times greater than the DC value at the end of the pulse causing anode breakdown. Figure 4 and 5 are photographs of anode voltage waveforms. The first is with the tube pulsing a resistive load while the second photo is with the load shorted. This latter one shows the transient effect of the circuits inductance quite clearly. An additional effect of inductance in the anode circuit is to cause the anode voltage to be momentarily reduced to near zero voltage until current builds up at the beginning of the pulse. This sudden drop in anode voltage causes the screen circuit to react by drawing heavy screen current until the anode voltage rises again to the level determined by the operating parameters of the tube. At this point the load should be mostly resistive and the pulse current essentially flat topped. Protection Schemes To protect the tubes from the effects of arcing, an open air type crowbar was used to discharge the capacitor bank and divert the power supply follow through current. Signals to trigger the crowbar were derived from (1) a current transformer in series with a spark gap connected between the screen and ground (2) an anode voltage sensing circuit consisting of a back biased diode and a small capacitor in series connected between anode and ground.

IC4-4 (3) bias failure circuit (4) excessive DC cathode current and (5) screen voltage interlock system. Anode Voltage Level The data sheet from the manufacturer lists the hold-off voltage as 40 KVDC. We have hipotted the tube to 90 KV. Eimac has had similar results in hipotting. Unfortunately this does not appear to be a safe operating voltage. The maximum anode voltage one could expect to operate is about 60-65 KVDC. The X-2159 has slightly over 1 em of spacing between the anode and screen grid so at 60-65 KVDC arc-over could be expected under operating conditions. This voltage could be subject to the current loading also. Determining the minimum anode voltage for maximum anode current has been somewhat of a problem. It appeared for awhile in the test that our data was following fairly closely with the test data taken by Eimac on the tube. After an extended shutdown period for repair of the regulator, the anode voltage during the pulse always appeared higher than our previous test indicated by about 3-8 KV. Suspecting that the calibration of voltage divider and current transformer were the problem, they were rechecked. Next the load was shorted out and a low current supply was used in place of the larger supply to charge up a large capacitor. This capacitor's voltage could then be measured more accurately with a precision meter as well as with a scope and HV probe. The results in this test were essentially the same i.e., the anode drop appeared to be too high. The problem has not been resolved as yet. It is suspected that a shifting has taken place somewhere in the tube or that some other damage has occurred. The confusing thing is that the same levels of anode current can be achieved and voltage hold-off does not appear to have deteriorated. A second tube is to be installed and tested to see if the same conditions exist. Test Results The following table gives some typical data points taken. The figures at the top of the table indicate earlier readings.

IC4-5 Ebb 1 AVG 1 PEAK Eb Eg Es KV AMP AMP KV VOLT VOLTS 40 5-39 36 4. 7 29.5 3.4 48 51 51 60 60 8.2 680 600 440 800 1000 1080 1280 1320 (1200) 4.8 225 1650 3-7 200 1500 5-7 200 1100 9.2 380 1500 4.3 400 2050 3.4 450 2300 12.4 600 2400 17.7 600 2400 9.2 340 2200 Maximum peak power switched has been up to 80 MW and average up to about 400 KW. Pulse lengths of 400 microseconds have been achieved at peak currents of 1000 amperes. Conclusions and Recommendations Although we have not conclusively determined what the expected anode voltage drop during the pulse is, it probably is about 5 KVDC at 1000 amperes pulse current. This is based on the output spacing of the tube and data taken at RADC and Eimac. To achieve this level the screen current is getting fairly high, 5-10% of the anode current The screen dissipation rating is adequate however so the screen primary emitter should be no problem. Another point to consider is secondary emission of electrons and resulting negative grid currents. Heavy grid eire~:~ loading is necessary for stability. Further testing to fully establish the maximum power that can be switched and the minimum anode drop will be performed as soon as our HV power supply is repaired at which time a full report will be ava i 1 ab 1 e.

IC4-6 2 511. 2511. 6-65 - KVOC 0-2500 v 18 J,lfO i jl_ PULSE 11'4,I ).If 0 SCOPE VIEW I METER Figure 1. Simplified Schematic of Pulser Figure 2. Photograph of Tube and Pulser

IC4-7 Figure 3. Negative Grid Current Spike at Pulse Tailend (Bottom) and effect on Anode Current Pulse (Top) Time: 40 usee/em Figure 4. -------- ----------------- Scope Photograph of Anode Voltage Pulse and Current at 60 KVDC Anode Voltage and 1220 Amp Pulse Current Time: 1rr usee/em

IC4-8 Figure 5. Scope Photograph of Anode Voltage and Current with Load Shorted. Anode Voltage 12 KVDC and Current 1200 Amps. Time 5 usee/em