LIGHT SOURCE 12W/FT OPTICS COLOR TEMPERATURES LUMEN MAINTENANCE ACTIVE WHITE - KELVIN TUNABLE 2700K - 6500K 75,000 hrs L70 ELECTRICAL LINE VOLTAGE Integral Power Supply, 120V or 277V CONTROL PHYSICAL TOTAL POWER CONSUMPTION DMX READY DIMENSIONS (HEIGHT X WIDTH) HOUSING LENS FIXTURE WATTAGE 6.0 W/ft 12.0 W/ft TOTAL POWER CONSUMPTION 6.0 W/ft 12.0 W/ft With Flat Lens: 3/4" X 1-5/8" With White Direct View Dome Lens: 1-3/8" X 1-5/8" Aluminum extrusion with molded end caps, powder-coated finish, White Flat Clear Acrylic Lens is standard Optional "Flat White Acrylic Lens" is available with 120 optics only. Allows for smooth light distribution, but does not remove diode images. Optional "White Direct View Lens" (DV) for direct view applications is available with 120 optics only. The Direct View Lens option creates a crisp white illuminattion and eliminates all diode images. CERTIFICATION OPERATING TEMPERATURES RoHS COMPLIANT -25 C to 40 C ETL and cetl Listed for Dry Location WARRANTY 5 Year Limited Warranty 5 Year Limited All PILOT products are tested to IES LM-79 standards Page 1 of 5
PLC Prefix PLC Pilot Cove Series Wattage Watts /Ft LED Color/CCT ACTIVE WHITE (TUNABLE) 12 AWH 120 = 120 X 120 Kelvin Tuning from 27K - 65K Optics Mounting Fixture Length ORDERING INFORMATION HM = Hinge FM = Fixed 24" 36" 48" Voltage/Wiring Method Control Options Finish Options ACV1 = 120V feed thru wiring for end-to-end fixture connection ACV2 = 277V feed thru wiring for end-to-end fixture connection Load not to exceed 16 amps See cable requirements below DMXFX = Resolution per power supply DMX Controls are required. Order separately Contact factory for Insight's Wireless Option W = Semi-Gloss White Contact factory for additional finishes WL = Flat diffusing lens (Available with 120 optics only) DV = Direct view dome lens for direct view applications (Available with 120 optics only) Contact factory for MRI applications All Active White products require a DMX programmer for proper mixing. Must order separately. One LPT is required for field re-addressing of factory DMX settings. See below. INTERIOR LEADER CABLES An AC Leader Cable is required with each fixture run for connection from first fixture to the j-box. ACL-5-W 5 WHITE LEADER CABLE - For line voltage only, Used for connection to the start of each run. INTERIOR JUMPER CABLES ACV WIRING METHOD allows for end-to-end fixture connection without additional AC jumpers. If fixtures are not mounted in an end-to-end continuous manner, AC jumpers are required. CATALOG # DESCRIPTION CATALOG # DESCRIPTION ACJ-2-W 2 WHITE JUMPER CABLE - For line voltage only ACJ-10-W 10 WHITE JUMPER CABLE - For line voltage only ACJ-5-W 5 WHITE JUMPER CABLE - For line voltage only ACJ-25-W 25 WHITE JUMPER CABLE - For line voltage only CATALOG NUMBER LPT CDS-A DMX PROGRAMMING KIT REQUIRED FOR ALL COLOR CHANGING INSTALLATIONS DMX PROGRAMMING TOOL One LPT is required for field re-addressing of factory DMX settings. DESCRIPTION DMX DISTRIBUTION KIT ONLY (4 OUTPUTS) CDS-A consists of four outputs. Each output accommodates up to 32 fixtures in INT/REM wiring methods and unlimted fixtures in ACV wiring method. Four terminators are included for use as required. Page 2 of 5
HM - HINGE MOUNT DIM 'A' FLAT CLEAR LENS IS STANDARD WITH HINGE MOUNT DIRECT VIEW LENS IS OPTIONAL 2-1/8" 2-1/8" DIM 'C' 3-1/8" 2-5/8" 3-7/8" 3-3/8" BOTTOM VIEW 100 2-3/8" 4-3/8" FIXTURE ROTATION DIM 'B' DIM 'D' DIM 'E' 2x clearance holes for #8 mounting hardware (by others, per hinge) MOUNTING BRACKET DETAIL 1-1/4" 2X Ø 1/8" FOR #6 MOUNTING FASTENERS (BY OTHERS) Static White, Dimming, RGBWWA, Dim DMX & RGB+W Fixture DIM -A- DIM -B- DIM -C- DIM -D- DIM -E- 24" 24-1/2" 4" 16-1/2" 1-1/4" to 6-1/4"< 4" to 14" 36" 36-1/2" 10" 16-1/2" 1-1/4" to 6-1/4"< 4" to 14" 48" 48-1/2" 16" 16-1/2" 1-1/4" to 6-1/4"< 4" to 14" Page 3 of 5
FM - FIXED MOUNT DIM "B" DIM "B" / 2 C L FLAT CLEAR LENS IS STANDARD 2 3/4" 2 5/8" 2 1/8" Ø1 1/8" Ø 1.25 THRU HOLE RECOMENDED DIM "A" INPUT 16 3/8" 3/8" DIM "B" DIM "B" / 2 C L DIRECT VIEW LENS IS OPTIONAL 2 1/8" DIM "A" 3 3/8" 3 3/8" Ø1 1/8" Ø 1.25 THRU HOLE RECOMENDED INPUT 16 3/8" 3/8" 2X Ø.188 THRU FOR #6 MOUNTING FASTENERS (BY OTHERS) 2 5/8" 1/2" Fixture DIM "A" DIM "B" 24" 24-1/2" 6" TO 15" 36" 36-1/2" 6" TO 15" 48" 48-1/2" 6" TO 15" Page 4 of 5
WIRING DETAILS TYPICAL -DMX, COLOR CHANGING ACV WIRING CONCEPT MAXIMUM FIXTURE RUN LENGTHS 16 AMP, 120V CIRCUIT WHITE LIGHT, STATIC COLORS AND RGB APPLICATIONS 32 FIXTURES @ 15 WATTS PER FOOT 16 AMP, 277V CIRCUIT WHITE LIGHT, STATIC COLORS AND RGB APPLICATIONS 32 FIXTURES @ 15 WATTS PER FOOT DMX LINE NOTES: 32 FIXTURES MAX PER OUTPUT 4 OUTPUTS PER CDS-A 800' MAX. TOTAL CABLE LENGTH PER DMX SPLITTER, (CDS-A ) ACV J-BOX BY OTHERS ( TYP. ) WARNING: REMOVAL OF END CAP ON THIS FIXTURE VOIDS ALL WARRANTIES! 120-277 AC LINE ( BY OTHERS ) BELDEN 9841 OR EQUIVALENT CABLE, IF APPLICABLE ( BY OTHERS ) CDS-A ( SEE DMX LINE NOTES ) CONTROL SOURCE 120-277 AC LINE ( BY OTHERS ) ACL REQUIRED ( 4FT LEAD PROVIDED TYP. ) From Previous Fixture DMX DAISY CHAIN To Fixture Line Black Ground Green Neutral White To Next Fixture Data + Yellow Data - Blue Data In CAUTION: THIS IS AN ELECTRONIC DEVICE. CARE MUST BE TAKEN DURING STORAGE AND HANDLING. STORE IN CLEAN, COOL, AND DRY LOCATION. ELECTROSTATIC DISCHARGE (ESD) CAN HARM THIS PRODUCT. AVOID STATIC DISCHARGE WHILE HANDLING THIS PRODUCT. 5/1/15 WARNING: ALL ELECTRICAL CONNECTIONS TO BE MADE BY A LICENSED ELECTRICIAN. WARNING: CAUTION: MAKE SURE ALL ELECTRICAL POWER IS OFF WHEN INSTALLING LUMINAIRES. INSIGHT LIGHTING IS NOT RESPONSIBLE FOR THE STRUCTURAL INTEGRITY OF THE BUILDING TO SUPPORT THE LUMINAIRE. ADDITIONAL BACKING MAY BE REQUIRED. NOTICE: SECONDARY CONNECTIONS SHALL BE MADE IN ACCORDANCE WITH NEC ARTICLE 725. 1 OF 1 Page 5 of 5