Installer manual. RS17.P Control panel for swing gates at 24 V DC with encoder EKKO 204D

Similar documents
CONTROL PANEL ENGLISH INSTRUCTIONS MOTORLINE MC 2 / SEAV LRS 2150 SET

MC2 USER / INSTALLER MANUAL. v5.1 REV. 03/2018

MC50BR USER / INSTALLER MANUAL. v5.0 REV. 07/ V

M150SP USER S AND INSTALLER S MANUAL. v2.0 REV. 03/2017

CONTROL UNIT BIOS1 HR Programmable Control board for sliding gates

414 P 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS 2. LAY-OUT OF STANDARD SYSTEM INSTALLATION DIMENSIONS. Fig. 1. Fig. A

POLARIS 4 ELECTRONIC CONTROL BOARD FOR SLIDING GATES MANUAL

L /2013 rev.4 CP.BISON OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

MC111 USER / INSTALLER MANUAL. v3.0 REV. 04/2018

VIVO-D203(M) Quick installation and programming guide. Elements of the complete installation

KR300 - KR302 - KR310 - KR312 KR510 - KR512

ROGER CONTROLLER. controller for 2 motors 230Vac H70/104AC - H70/105AC. EN - Instruction and warnings for the installer. automazioni evolute

L /2013 rev.3 CP.BISON OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

Gamma instabus. Technical product information

CONTROL PANEL FOR 230 V GEARMOTORS FA00385-EN INSTALLATION MANUAL ZM3E - ZM3EC - ZM3EP. English

Troubleshooting CS800/LC900 Bikes

BT Diverse Repeater. User Guide

intro Automation for swing gates with leaves up to 4 m Kg, undergroung installation

SWIFT624-CB AUTOMATION SYSTEMS. DRIVER FOR SWIFT624 DRIVE Assembly manual for the installers. automation systems. ver. 1.0

NECT 540 U CONNECT 540 UHD USER MANUAL 3 GEBRAUCHSANLEITUNG GUIDE UTILISATEUR MODO DE EMPLEO MANUALE D ISTRUZIONI GEBRUIKSAANWIJZING

PG SERIES Garage Door Openers USER MANUAL

CONTROL PANEL FOR 24 V GEARMOTORS FA00038-EN INSTALLATION MANUAL ZLJ24. English

EC5415B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 15-channel, bidirectional

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2

CONTROL PANEL FOR 230 V GEARMOTORS FA00385-EN INSTALLATION MANUAL ZM3E - ZM3EC - ZM3EP. English

E R A I GATE OPENERS DEPARTMENT

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

Manual. Kingpad mc-edition light-module. Bus system control pad for installation in the Graupner mc-16 / mc-20 / mc-26 / mc-28 transmitter

K9123, K9134, K9135 Remote Programming Instructions and Specifications

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

Tech Support: Customer Service: General Tech Questions: Tech Docs:

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Operating instructions

LIGHT AIR SWITCH. User Manual and Troubleshooting Guide WIRELESS LIGHTING MODULE ACKNOWLEDGEMENTS SAFETY WARNINGS EQUIPMENT DESCRIPTION

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

DLP200M 2 Relay Module for Heating and Cooling Plants

Fusion 120 Zoom. User Manual. Order code: EQLED068

DVBus and Multiplexer and demultiplexer assemblies for video channels, with bidirectional audio and data USER MANUAL

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

EA350. Generator Automatic Voltage Regulator Operation Manual

Connect 350 UHD. Connect 350 UHD USER MANUAL 3 GEBRAUCHSANLEITUNG GUIDE UTILISATEUR MODO DE EMPLEO MANUALE D ISTRUZIONI GEBRUIKSAANWIJZING

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

TruVision High Definition TVI Bullet Camera Installation Guide

Registers type ILR7XX and ILR7XXT

2-output DALI controller

RF Wireless Receiver (Model S4PU-DC-ANT3)

Automatic Control Panel, Type EP103 For electrically operated gates, barriers & doors

Access Converter/ 3. Operation Manual. International Headquarters. European Headquarters. B&B Electronics. 707 Dayton Road Ottawa, IL USA

MICROMASTER Encoder Module

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

FOREST SHUTTLE S / L / M RECEIVER

A B C D. Call-way AB

USER AND INSTALLATION MANUAL ENGLISH SWITCHPACK. PART01245 CONTROL GEAR. rev 01-00

Multi-functional safety relay modules PROTECT SRB-E

PROGRAMMING MANUAL MTMRFID FB00435-EN

Satellite B or D. Satellite Inputs (LNB Trunk)

TruVision High Definition TVI Vandal Dome Installation Guide

PHOBOS AC A CONTROL UNIT TECHNICAL FEATURES

TVAC20000 User manual

SQM40/41 Actuators for air and gas dampers

Automation for: SWING GATES

HDMI Extender over UTP Cable

PRO Mixer Distro User Guide

RADIO RECEIVER RGBW CONTROLLING LED STRIP COMMON ANODE

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

Transfer Switch. OTECA (Spec A) OTECB (Spec A) OTECC (Spec A) OTECD (Spec A) Amperes. English Original Instructions (Issue 5)

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

Digital differential Pressure switch Model DPS Instruction manual

Foreword: The purpose of this document is to describe how to install and configure Neets 4 relay box

Operating Manual. Basic Control BC16. two-channel for eco moon

SWIFT6-CB AUTOMATION SYSTEMS. DRIVER FOR SWIFT6 DRIVE Assembly manual for the installers. automation systems. ver. 1.0

RDC vision Installation and operating instructions 1-48

Operating instructions Through-beam sensor. OJ51xx laser / / 2010

Junior Max (JR Max ) Controller

HP Presentation Scanner. Quick Reference Guide

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

4 Wiring Brochure Wiring and installation of specific control

.Power Distribution Center. PD-1. Instruction Manual

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

KHT 1000C HV-Probe Calibrator. Instruction Manual

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

Aspect 2 Circuit Digital Scene Control

AES-404 Digital Audio Switcher/DA/Digital to Analog Converter

Figure 1: Device components

SceneStyle2 User Guide

TETRA 42x0. 1. General description. Four Channel Digital Video Multiplexer with Two-Way Data USER MANUAL

MATE3 Owner s Manual Addendum

SY-HDBT-SLIM-100S Extender Set

Single Axis Position Controller

IFS MC252-1T-1CXP and MC252-1P-1CX User Manual

MSF1000. MSF Radio Time Code Receiver. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

Installing the FOREST SHUTTLE S / L

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

SY-HDBT-100 Extender Set

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

Transcription:

Installer manual RS17.P Control panel for swing gates at 24 V DC with encoder EKKO 204D

RS17.P Table of Contents...Page Product features...1 System type...1 of the terminal blocks...2 Connecting accessories...4 Trimmer functions...5 Button functions...5 DIP-switch functions...6 LED functions...6 Time setting...7 Programming the remote controls...8 Troubleshooting...9 WARNINGS FOR THE INSTALLER Carefully read all the instructions and warnings in this document as they provide important information regarding safe installation, operation and maintenance. After removing the packaging, check the condition of the equipment. The packaging must not be left within reach of children as it is potentially harmful. Installation must be carried out in accordance with national safety regulations. This equipment must be used only for the purpose for which it was expressly intended, i.e. for the automation of motors for roller blinds and for controlling resistive loads such as lights. Any other use is considered improper and therefore hazardous. The manufacturer declines all liability for damage caused by improper, incorrect or unreasonable use. Always disconnect the equipment from the power supply at the main switch before performing maintenance or cleaning procedures. In the event of faults and/or malfunctions, disconnect the equipment from the power supply at the switch and do not tamper with it. For repairs, contact only a service centre authorized by the manufacturer. Failure to observe the above may jeopardize the safety of the equipment. All equipment within the system must be used exclusively for the purpose for which it is intended. This document must always be kept with all paperwork regarding the installation. Directive 2002/96/EC (WEEE). The crossed out wheelie bin symbol marked on the equipment indicates that, at the end of its useful working life, the product must be handled separately from household refuse and must therefore be assigned to a differentiated collection centre for electrical and electronic equipment or returned to the dealer upon purchase of a new, equivalent item of equipment. The user is responsible for ensuring the equipment is disposed of through the correct channels when no longer in service. Proper sorted waste collection for subsequent recycling, processing and environmentally conscious disposal of the old equipment helps to prevent any possible negative impact on the environment and human health while promoting the practice of recycling materials used in manufacture. For further details regarding available collection systems, contact your local waste disposal service or the shop from which the equipment was purchased. Risks associated with substances considered hazardous (WEEE). According to the new WEEE Directive, substances which for some time have been widely used in electrical and electronic equipment are considered hazardous to human heath and the environment. Proper sorted waste collection for subsequent recycling, processing and environmentally conscious disposal of the old equipment helps to prevent any possible negative impact on the environment and human health while promoting the practice of recycling materials used in manufacture. Enclosure sizes 2

1 - Product features: Control panel for governing swing gates for 24 Vdc gearmotors with encoder with battery charger and integrated receiver. The control panel: - enables customizing the deceleration distance - is equipped with an obstacle detection system - is equipped with input diagnostics LED - is equipped with an integrated 433 MHz receiver with a maximum capacity of 50 remote controls - is equipped with short-circuit protection - is equipped with a switching power supply Technical data: Power supply Motor power supply voltage Maximum motor power Output for flashing light Electrical lock output Accessories power supply Receiver memory Receiver frequency Remote controls code Fuse F1 Fuse F2 Operating temperature 120 to 230 Vac 24 Vdc 80 to 80 W 24 Vdc 10 W max 12 Vsc 15 VA max 24 Vdc 300 ma 50 remote controls 433 MHz Rolling code or fixed Line protection 5x20 mm T1.6 A Accessories protection 5x20 mm T8A -10 to +50 C 2 - System type: For the sizing of the cable routing, the required cross-sections of the cables are shown below C 4x0,5 mm 2 +RG58 G F 2x2,5 mm 2 E 2x2,5 mm 2 4x0,5 mm 2 E B A A 2x2,5 mm 2 +3x0,5 mm 2 (encoder) 2x2,5 mm 2 +3x0,5 mm 2 (encoder) D 3x2,5 mm 2 120/230 Vac Legend A - Linear actuator B - Control unit C - Flashing light with aerial D - 2-channel remote control E - Pair of photocells F - Selector G - Electrical lock VIMAR group 1

1 + 3 - of the terminal blocks - - 2 3 4 5 6 7 8 9 10 + ANT _ L N F1 MOT 2 PROG A 21 22 25 26 19 18 11 0 17 F2 PWR OFF MRX 1 2 3 4 5 6 7 8 9 10 51 MOT 1 64 63 62 +E 41 45 -E 1 0 +B -B 52 51 62 63 64 61 99 51 52 61 B A F1 T 1 OP L N 21 22 25 26 19 18 11 0 17 +E 41 45 -E 2 CLOSE 3 CODER+ L N OP M1 CLOSE M1 OP M2 CLOSE M2 LOCK+ BLINK+ CODER- LOCK- 24V- SCA+ CODER+ C SIG M1 C SIG M2 4 C SIG 5 CODER- 230 Vac 120 Vac M2 SCA M1 Terminal Rated data L Phase 2 Earth N Neutral 21 Opening motor 1 22 Closing motor 1 25 Opening motor 2 26 Closing motor 2 18 Electrical lock negative 19 Electrical lock positive 11 Flashing light positive 0 Accessories negative 17 Photo-test or gate open warning light positive 0 Accessories negative 120 to 230 V AC 24 V DC 80W 24 V DC 80W 12 V AC 15 VA 24 V DC 10 W 24 V DC 120 ma Terminal Rated data +E Encoder positive 41 Motor 1 encoder signal 45 Motor 2 encoder signal -E Encoder negative Note: The cable connecting the encoder to the control panel must be no longer than 10 m and have no shielding. For encoder cabling longer than 10 m and in any case no longer than 15 m, a shielded cable must be used.

B Terminal Rated data 1 Accessories positive 24 Vdc 300 ma 0 Accessories negative Emergency battery +B positive Emergency battery -B negative 52 Pedestrian (N.O.) 51 Step by step (N.O.) Photocell when closing (N.C.) 62 63 Photocell (N.C.) 64 Sensitive edge (N.C.) 61 Stop (N.C.) 99 Common inputs ANT Aerial signal - Aerial earth E 41 45 -E 51 52 1 0 +B -B 52 51 62 63 64 61 99 61 - + - + 12 Vdc 1,3Ah 12 Vdc 1,3Ah + - 24V+ 24V- PED P.P. PHC PH ANT BAR _ STOP 3.1 - of output function: 0-1 - Accessories power supply voltage: Permanent 24 Vdc output 18-19 - Electrical lock: 12 Vac output powered for 2 s at the start of the opening movement 0-11 - Flashing light: 24 Vdc output powered when the gate is moving 0-17 - Photo-test or gate open warning light: 24 Vdc output for signalling gate status or performing the safety test: With DIP 8 = OFF it is Gate Open Warning Light - Not powered with gate closed - Powered continuously with gate open or moving With DIP 8 = it is Photo-test Used for the power supply of the transmitters of the safety devices. Note: Using the photo-test requires specific wiring of the safety devices (par. 4.3). 3.2 - of input function: 51 - Step by step (N.O.): Sequential command input, to control the complete travel of the gate. It works with the following cycle: open-stop-close-stop or open-stop-close-open according to the setting of DIP 3 52 - Pedestrian (N.O.): Command input for opening to the pedestrian distance 61 - Stop (N.C.): Gate stops, does not turn off automatic closing. If not used, jumper with the common (99) 62 - Photocell when closing - PHC (N.C.): Photocell when closing, with the gate stationary it allows opening, when opening it does not trigger, with the gate open it does not allow closing and on release it resets the automatic closing time, when closing it commands immediate reopening. If not used, jumper with the common (99) 63 - Photocell - PH (N.C.): Photocell, active both when closing and when opening, with the gate stationary it does not allow opening, during opening it stops the movement and on release it continues opening, with the gate open it does not allow closing and on release it resets the automatic closing time, when closing it stops the movement and on release it commands reopening. If not used, jumper with the common (99) 64 - Sensitive edge (N.C.): Safety sensitive edge, N.C. dry contact, with the gate stationary it does not allow opening, when opening it disengages, with the gate open it does not allow closing and on release it resets the automatic closing time, when closing it disengages. If not used, jumper with the common (99) VIMAR group 3

4 - Connecting accessories: 4.1 - Key switch and control devices 52 51 62 63 64 61 99 N.C. N.C. Pedestrian PED P.P. N.O. N.O. Step by step 4.2 - Photocells and photocells when closing RX1 RX2 TX1 TX2 1 0 +B -B 52 51 62 63 64 61 99 (FSW) NO NC - + (FSW) NO NC - + - + - + 24V+ 24V- PHC PH 4.3 - Photocells and photocells when closing with photo-test active (DIP 8 = ) TX1 TX2 0 17 - + - + RX1 (FSW) NO NC - + RX2 (FSW) NO NC - + 1 0 +B -B 52 51 62 63 64 61 99 24V+ 24V- PHC PH 24V- SCA+ 1 2 3 4 5 6 7 8 9 10 OFF 1 2 3 4 5 6 7 8 9 10 4

+ + 4.4 - Sensitive edge 52 51 62 63 64 61 99 BAR 4.5 - Stop push button 52 51 62 63 64 61 99 STOP 5 - Trimmer functions - Trimmer MOT 1 Power of motor 1 (turn the trimmer clockwise to increase the power) MOT 2 MOT 2 Power of motor 2 (turn the trimmer clockwise to increase the power) - MOT 1 6 - Functions of the buttons: PROG MRX 51 Button PROG MRX Button for programming the travel Button for programming or deleting remote controls 51 Step-by-step command button VIMAR group 5

7 - DIP-switch functions: R 1 2 3 4 5 6 7 8 9 10 OFF 1 2 3 4 5 6 7 8 9 10 DIP Function Status DIP 1 Close immediately OFF Close immediately off Close immediately on: The engagement and subsequent disengagement of the photocell when closing, while opening or during the pause time causes the gate to reclose immediately at least 3 s after full opening, regardless of the set automatic closing time. DIP 2 Automatic closing OFF Automatic closing off Automatic closing on DIP 3 Step-step logic OFF 2 steps: step-by-step (term. 51 and radio) with logic in 2 steps (open - close - open) Step-by-step command (term. 51 and radio) with logic in 4 steps (open - stop - close - stop - open - stop) DIP 4 Apartment block OFF Apartment block off Apartment block on (while the gate is opening, you cannot stop the movement with a radio command or with inputs 51 (step-by-step) and 52 (pedestrian). With automatic closing on (DIP-switch 2 = ) and the gate open, an additional step-bystep command (terminal 51 or radio command) renews the pause time and if input 51 remains engaged the control panel suspends the pause count until the input is disengaged (for connecting any coils or a timer). DIP 5 Slowdown distance OFF Slowdown distance at 10% of the travel Slowdown distance at 20% of the travel DIP 6 Hammering OFF Hammering for electrical lock off Hammering for electrical lock on (required when using an electrical lock) DIP 7 Status of gate at reset OFF Status of gate closed at reset Status of gate open at reset When the power supply is restored, a step-by-step command causes closing and if automatic closing is on (DIP-switch 2 = ), closing occurs after the pause time DIP 8 Photo-test OFF Photo-test off Photo-test on At the start of each action, the control panel checks the operation of the photocells. It requires specific wiring DIP 9 Normal speed OFF High normal speed Low normal speed DIP 10 Number of motors OFF Double swing gate leaf (M1 and M2 on) Single swing gate leaf (only M1 on) 8 - LED functions 64 63 62 51 52 LED Status PWR OFF Mains power supply not present Mains power supply present MRX 1 blink Saving a new remote control 2 blinks Saving a remote control already in memory 3 blinks Deleting a remote control 4 blinks Radio memory full 5 blinks Savable remote control not in memory 10 blinks Complete deletion of the radio memory 51 OFF Step-by-step input (term. 51) not engaged Step-by-step input (term. 51) engaged 52 OFF Pedestrian input (term. 52) not engaged Pedestrian input (term. 52) engaged 61 OFF Stop contact (term. 61) open (engaged) Stop contact (term. 61) closed (not engaged) 62 OFF Photocell engaged when closing (term. 62 open) Photocell not engaged when closing (term. 62 closed) 63 OFF Photocell engaged when opening (term. 63 open) Photocell not engaged when opening (term. 63 closed) 64 OFF Sensitive edge engaged (term. 64 open) Sensitive edge not engaged (term. 64 closed) 6

9 - Time setting The control panel is programmed by default with the following times: - automatic closing: 30 s - offset for opening: 3 s - offset for closing: 6 s To change the default times, follow the procedure below (the phases for installing a double swing leaf gate have a grey background; if there is a single leaf, the leaf offsets are not programmed) The control panel does not need travel setting as this is automatically measured with each action. For this to happen, run a complete open-close action (it will take place at reduced speed as the control panel does not know the exact position of the leafs). NOTE: In order to perform this procedure, the gate must be stationary. CAUTI! THE SAFETY DEVICES ARE DISABLED WHILE CARRYING OUT THIS PROCEDURE.. No. Pressing push button Phase 1 PROG Procedure activation Press and hold down the PROG push button until the flashing light comes on steady, then release the button, and the automatic gate system will now close the gate. 2 - Leaf closing Unless the leafs are already closed, the first action MUST be CLOSING; otherwise, cut off the power supply to the control panel and invert the cables of the motor that opens instead of closing. N.B. DO NOT INVERT THE CODER CABLES. 3 - Opening M1 M1 starts to open and the control panel starts the count of the offset for opening 4 51 Setting the offset for opening After the desired time, press and release button 51 to set the offset for opening (if not pressed, after 40 s M2 will start automatically). M2 starts opening 5 - Completion of opening M1 and M2 continue to open at low speed until they reach the mechanical stops on opening 6 51 Setting the pause time With the gate stationary in the fully open position, the automatic closing time count starts, after the required length of time has passed, press and release push button 51, the control panel will save the elapsed time (max. 250 seconds) 7 - Closing M2 M2 starts to close and the control panel starts the count of the offset for closing 8 51 Setting the offset for closing M1 starts closing 9 - Completion of closure and end of programming Note: If you want to return the control panel to default, perform the following procedure: 1. Disconnect the power to the control panel 2. Press and hold the PROG button. 3. Reconnect the power to the control panel and wait for the flashing light to come on steady. 4. After 3 sec., release the PROG button. The flashing light will turn off. 5. The control panel is now set with the default times. After the desired time, press and release button 51 to set the offset for closing (if not pressed, after 130 s M1 will start automatically). The automation completes the closure when it reaches the closing mechanical stops and the flashing light goes out to signal that the travel programming procedure has been exited. 10 - Remote control programming Note: Remote control programming can only be done with the automatic gate system stationary Step-by-step programming: No. Pressing push button Signal MRX LED 1 MRX Off Press and hold down the MRX push button for no more than 7 s 2 MRX+ remote control - With the MRX push button still pressed, press the button of the remote control to be saved 3-1 blink Button of the saved remote control (new remote control) 2 blinks Button of the saved remote control (remote control already in memory) Programming the pedestrian: No. Pressing push button Signal MRX LED 1 MRX+PROG Off Press and hold down the MRX and PROG push buttons for no more than 7 s 2 MRX+PROG+remote control - With the MRX and PROG push buttons still pressed, press the button of the remote control to be saved 3-1 blink Button of the saved remote control (new remote control) 2 blinks Button of the saved remote control (remote control already in memory) Deleting a remote control No. Pressing push button Signal MRX LED 1 MRX On steady Press and hold down the MRX push button for at least 7 s until the MRX LED comes on steady 2 MRX+ remote control - With the MRX push button still pressed, press the button of the remote control to be deleted 3-3 blinks Deletion successful VIMAR group 7

Complete deletion of the receiver No. Pressing push button MRX LED indicator 1 MRX Flashing light Press and hold down the MRX push button for at least 14 s until the MRX LED starts flashing 2-10 blinks Complete deletion of the receiver Note: After deleting all the remote controls, the first saved remote control configures the control panel to accept only remote controls with a rolling code or only remote controls with a fixed code. 11 - Troubleshooting Problem Cause Solution The automation system does not No mains supply Check the power line switch work Blown fuses Replace blown fuses with others of the same value Control and safety inputs not working Check the diagnosis LEDs (FCL, FOP, COSTA and STOP must be on) You cannot save the remote controls Safety devices open FCL, FOP, COSTA and STOP must be on Batteries of the remote control discharged Replace the batteries As soon as the gate starts, it stops and reverses Movement of one of the 2 motors is reversed During calibration the motor M1 starts and stops after 1 second With the electrical lock the motor 1 is not able to start opening or does not close completely After a command the flashing light blinks 6 times but the gate fails to open The flashing light does not work during the movement The gate moves at slowdown speed The gate opens one leaf at a time with an offset of 40s The gate detects an obstacle even when it is not there Closing one leaf at a time Remote control not compatible with the first one saved Reached memory saturation Motor torque not sufficient Wrong wiring Encoder 1 wiring reversed with encoder 2 Electrical lock unable to get freed The first saved remote control configures the control panel to save only rolling-code remote controls or only dip-switch remote controls Delete at least one remote control or add an external receiver (maximum capacity 50 remote controls) Increase the power via trimmer MOT 1 for motor M1 and MOT 2 for M2 Check the motor wiring Check the encoder wiring Set DIP-switch 6 in position (hammering on) Photo-test check failed Check the electrical wiring (see section 4) and DIP-switch 8 Check the alignment of the photocells No mains power supply and motors on battery operation Probable 230 V AC mains failure The leaf offset has not been programmed - Incorrect bracket dimensions - Force trimmer too low - Gate mechanics stiff - Previous no mains - Reset action in case of overlapping leafs. Check the mains power supply Run 1 complete open/close action Return the working times to default or if necessary program them. - Check dimensions - Raise force trimmer - Service the gate Wait for the operation to be completed, the gate will be reset automatically 8

EC DECLARATI OF CFORMITY (Declaration of incorporation of partly completed machinery annex IIB 2006/42/EC) The undersigned, representing the following manufacturer Vimar SpA Viale Vicenza, 14-36063 Marostica (VI) Italy herewith declares that the products No. : ZDT00737.00 Electronic control unit Articles Trade mark Type ref. Cat. ref. * Elvox RS16 RS16 24V ACTO 404D control card Elvox RS17 RS17 24V EKKO 204D control card Elvox RS17.A RS17.A Switchboard 24V EKKO ART 204D Elvox RS17.P RS17.P Switchboard 24V EKKO 204D when installed with the appropriate accessories and/or enclosures for devices are in conformity with the provisions of the following EU directive(s) (including all applicable amendments) Machinery Directive 2006/42/CE 60335-2-103 (2015), 13241 (2003) + A2 (2016), 12453 LV Directive 2014/35/EU (2002) R&TTE Directive 1999/5/CE 301 489-3 (2013), 300 220-2 (2012) EMC Directive 2014/30/EU 61000-6-1 (2007), 61000-6-3 (2007) + A11 (2011) Further hereby declares that the product must not be put into service until the final machinery into which it is to be incorporated has been declared in conformity with the provisions of Directive 2006/42/EC, where appropriate. Declares that the relevant technical documentation is compiled by Vimar SpA and in accordance with part B of Annex VII of Directive 2006/42/EC and the following essential requirements of this Directive are applied and fulfilled: 1.1.1, 1.1.2, 1.1.3, 1.1.5, 1.1.6, 1.2.1, 1.2.2, 1.2.6, 1.3.1, 1.3.2, 1.3.3, 1.3.4, 1.3.7, 1.3.8, 1.3.9, 1.4.1, 1.4.2, 1.5.1, 1.5.2, 1.5.4, 1.5.5, 1.5.6, 1.5.7, 1.5.8, 1.5.9, 1.6.1, 1.6.2, 1.7.1, 1.7.2, 1.7.3, 1.7.4. I undertake to make available, in response to a reasoned request by the national authorities, any further supporting product documents they require. Marostica, 24/02/2015 The Managing Director Note: The contents of this declaration correspond to what declared in the last revision of the official declaration available before printing this manual. The text herein has been re-edited for editorial purposes. A copy of the original declaration can be requested to Vimar SpA VIMAR group 9

RS17.P installer 01 1706 Viale Vicenza 14 36063 Marostica VI - Italy www.vimar.com