100G SR4 TxVEC Review Comment r01-43

Similar documents
Draft 100G SR4 TxVEC - TDP Update. John Petrilla: Avago Technologies February 2014

100G SR4 Link Model Update & TDP. John Petrilla: Avago Technologies January 2013

100G SR4 TxVEC - TDP Update (D2.1 comment 94) John Petrilla: Avago Technologies March 2014

Systematic Tx Eye Mask Definition. John Petrilla, Avago Technologies March 2009

100GBASE-SR4 Extinction Ratio Requirement. John Petrilla: Avago Technologies September 2013

100G MMF 20m & 100m Link Model Comparison. John Petrilla: Avago Technologies March 2013

100G CWDM Link Model for DM DFB Lasers. John Petrilla: Avago Technologies May 2013

100G PSM4 & RS(528, 514, 7, 10) FEC. John Petrilla: Avago Technologies September 2012

40G SWDM4 MSA Technical Specifications Optical Specifications

40G SWDM4 MSA Technical Specifications Optical Specifications

64G Fibre Channel strawman update. 6 th Dec 2016, rv1 Jonathan King, Finisar

500 m SMF Objective Baseline Proposal

Measurements Results of GBd VCSEL Over OM3 with and without Equalization

Channel Performance 2 vs 4 Wavelengths

New Metric Offers More Accurate Estimate of Optical Transmitter s Impact on Multimode Fiber-optic Links

Ali Ghiasi. Nov 8, 2011 IEEE GNGOPTX Study Group Atlanta

SMF Ad Hoc report. Pete Anslow, Ciena, SMF Ad Hoc Chair. IEEE P802.3bm, Geneva, September 2012

50 Gb/s per lane MMF objectives. IEEE 50G & NGOATH Study Group January 2016, Atlanta, GA Jonathan King, Finisar

40GBASE-ER4 optical budget

An Approach To 25GbE SMF 10km Specification IEEE Plenary (Macau) Kohichi Tamura

50 Gb/s per lane MMF baseline proposals. P802.3cd, Whistler, BC 21 st May 2016 Jonathan King, Finisar Jonathan Ingham, FIT

Proposed reference equalizer change in Clause 124 (TDECQ/SECQ. methodologies).

TP1a mask, noise and jitter for SRn

CAUI-4 Chip to Chip Simulations

By Jim Norton Bird Technologies Group Applications Engineer

Reducing input dynamic range of SOA-preamplifier for 100G-EPON upstream

Using SOAs as Booster and/or Pre-Amplifier for 4x25-Gb/s 40-km 1310-nm PMD

On Figure of Merit in PAM4 Optical Transmitter Evaluation, Particularly TDECQ

CABLE LOSS MASKING EFFECT

10GBASE-LRM Interoperability & Technical Feasibility Report

Validation of VSR Module to Host link

USB 3.1 ENGINEERING CHANGE NOTICE

Next Generation Ultra-High speed standards measurements of Optical and Electrical signals

Ali Ghiasi. Jan 23, 2011 IEEE GNGOPTX Study Group Newport Beach

Transmitter Preemphasis: An Easier Path to 99% Coverage at 300m?

Optical transmission feasibility for 400GbE extended reach PMD. Yoshiaki Sone NTT IEEE802.3 Industry Connections NG-ECDC Ad hoc, Whistler, May 2016

Proposal for 400GE Optical PMD for 2km SMF Objective based on 4 x 100G PAM4

400G-FR4 Technical Specification

SECQ Test Method and Calibration Improvements

PIN-PD based ONU for 10GE-PON (3)

Component BW requirement of 56Gbaud Modulations for 400GbE 2 & 10km PMD

EVLA Fiber Selection Critical Design Review

Toward Baseline for 400GBASE-ZR Optical Specs

QSFP SV-QSFP-40G-PSR4

Using Allegro PCB SI GXL to Make Your Multi-GHz Serial Link Work Right Out of the Box

TDECQ update noise treatment and equalizer optimization (revision of king_3bs_01_0117) 14th February 2017 P802.3bs SMF ad hoc Jonathan King, Finisar

Combating Closed Eyes Design & Measurement of Pre-Emphasis and Equalization for Lossy Channels

Combating Closed Eyes Design & Measurement of Pre-Emphasis and Equalization for Lossy Channels

TP2 and TP3 Parameter Measurement Test Readiness

Further information on PAM4 error performance and power budget considerations

Technical Feasibility of Single Wavelength 400GbE 2km &10km application

DATA SHEET. Two (2) fibers Detachable HDMI 2.0 Extender,

Module 11 : Link Design

100G-FR and 100G-LR Technical Specifications

Product Specification 100m Multirate Parallel MMF 100/128G QSFP28 Optical Transceiver FTLC9551SEPM

40GBd QSFP+ SR4 Transceiver

Comparison of options for 40 Gb/s PMD for 10 km duplex SMF and recommendations

100GBASE-DR2: A Baseline Proposal for the 100G 500m Two Lane Objective. Brian Welch (Luxtera)

Comparison of NRZ, PR-2, and PR-4 signaling. Qasim Chaudry Adam Healey Greg Sheets

Draft Baseline Proposal for CDAUI-8 Chipto-Module (C2M) Electrical Interface (NRZ)

10Gbps SFP+ Optical Transceiver, 10km Reach

Comment #147, #169: Problems of high DFE coefficients

Application Note 5098

10GBASE-R Test Patterns

Ordering information. 40Gb/s QSFP+ ER4 Optical Transceiver Product Specification. Features

Further work on S/N Budget Channel specification May 8

Maps of OMA, TDP and mean power. Piers Dawe Mellanox Technologies

XLAUI/CAUI Electrical Specifications

DATA SHEET. Two (2) fibers Detachable DisplayPort 1.2 Extender, DPFX-200-TR

100G QSFP28 SR4 Transceiver

TRFM Series RF Amplifier Module

IMC-21A Series. Industrial 10/100BaseT(X) to 100BaseFX media converters. Introduction. Specifications. Ethernet Media Converters and Extenders

Updated Considerations on 400Gb/s Ethernet SMF PMDs

Fast Ethernet Consortium Clause 25 PMD-EEE Conformance Test Suite v1.1 Report

New Serial Link Simulation Process, 6 Gbps SAS Case Study

10Gb/s SFP+ ER 1550nm Cooled EML with TEC, PIN Receiver 40km transmission distance

Measurements and Simulation Results in Support of IEEE 802.3bj Objective

10Gbps 10km Range SFP+ Optical Transceiver

BER margin of COM 3dB

Improving the Performance of Advanced Modulation Scheme. Yoshiaki Sone NTT IEEE802.3bs 400 Gb/s Ethernet Task Force, San Antonio, Novenver 2014.

Experimental results of SOA pre-amplification for 25G-EPON IEEE P802.3ca Task Force Meeting, March 2017 Vancouver BC, Canada

10Gbps 10km Range 1310nm SFP+ Optical Transceiver

Project: IEEE P Working Group for Wireless Personal Area Networks (WPANs)

Simula'on Study on 100G EPON Wavelength Plan A. Eugene (Yuxin) Dai Cox Communica'ons IEEE 802.3ca 100G EPON TF November, 2016 San Antonio, Texas, USA

December Spectrum Management and Telecommunications Policy

10Gb/s SFP+ Optical Transceiver Module 10GBASE-LR/LW

Application Space of CAUI-4/ OIF-VSR and cppi-4

EMPOWERFIBER 10Gbps 2km SFP+ Optical Transceiver EPP C

InfiniBand Trade Association

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

DATA SHEET. Two (2) fibers Detachable DisplayPort Extender, DPFX-100-TR

InfiniBand Trade Association

In support of 3.5 db Extinction Ratio for 200GBASE-DR4 and 400GBASE-DR4

Improved extinction ratio specifications. Piers Dawe Mellanox

TP2 con-call comment resolution - actions from Austin - May 26 June 9 (3 calls) Tom Lindsay 802.3aq London, June 2005

FIBRE CHANNEL CONSORTIUM

Practical De-embedding for Gigabit fixture. Ben Chia Senior Signal Integrity Consultant 5/17/2011

Parameter Symbol Min. Typ. Max. Unit. Supply Voltage Vcc V. Input Voltage Vin -0.3 Vcc+0.3 V. Storage Temperature Tst C

200GBASE-DR4: A Baseline Proposal for the 200G 500m Objective. Brian Welch (Luxtera)

Features: Compliance: Applications: Warranty: 49Y7928-GT QSFP+ 40G BASE-SR Transceiver IBM Compatible

Transcription:

100G SR4 TxVEC Review Comment r01-43 John Petrilla: Avago Technologies September 2014

Presentation Summary Link model analysis results from various combinations of worst and best case Tx attributes are shown to provide background for determination of the max TxVEC limit. Simulations results show that while instrumentation noise can affect the observed eye, TxVEC results appear unaffected. A variety of Tx eyes (as observed after a 12.6 GHz LPF with 9 uw additive noise) and associated TxVEC results are shown. BER plots are shown for a TxVEC = 4.56 db Tx and a TxVEC = 5.30 db Tx, a 110 m, 5023 MHzkm EBW OM4 fiber and several receivers. Comment r01-43 The value, 5, entered for max TxVEC may not be correct for the method defined 95.8.5 and its subclauses and should be verified. One check was to use a link model and replace the worst case Rx with an Ref Rx with the same sensitivity and then replace the worst case Tx with an idealized Tx. The difference in link penalties and margin varies from 4.9 db to 5.0 depending on inclusion/deletion of Pmn. SuggestedRemedy Review the value entered in Table 95-6 for max TxVEC and the factors 0.0257 and 0.01 in the equation for M and adjust as appropriate. For details see petrilla_01_0914_optx Ottawa September 2014 Avago Technologies: 100G SR4 TxVEC Review 2

Consideration of Max and Min TxVEC Results WC B Rx B Tx F BC Max 1 TxVEC Min TxVEC Reach 100 100 2 2 2 2 2 Max 2 TxVEC Uc 840 840 860 860 840 840 840 Uw 0.60 0.60 0.05 0.05 0.60 0.60 0.60 tt 21 21 1 1 21 1 21 krin 0.70 0.70 0 0 0.70 0 0.70 kmpn 0.30 0.30 0 0 0 0 0 Pmn 0.129 0.129 0 0 0 0 0.129 TP1 RJ (BER) 0.053 0.053 0 0 0.053 0 0.053 TP1 DJ 0.110 0.110 0 0 0.110 0 0.110 DCD 0.05 0.05 0 0 0.05 0 0.05 TP3 DJ 0.247 0.247 0 0 0.247 0 0.247 Rx DJ 0.05 0 0.05 0 0 0 0 TP4 TJ 0.780 0.780 0.780 0.780 0.780 0.780 0.780 BLW 0.025 0 0.025 0 0 0 0 RxBW 18.05 19.34 18.05 19.34 12.60 12.60 12.60 Signal Budget 8.20 8.20 8.20 8.20 8.20 8.20 8.20 IL 1.86 1.86 1.51 1.51 1.51 1.51 1.51 LP Pen 6.34 5.34 0.21 0.10 4.86 0.75 5.17 Margin 0.00 1.00 6.48 6.59 1.83 5.94 1.52 The table shows link penalty, LP Pen, and link margin, Margin, for combinations of attributes relevant in the determination of the max acceptable TxVEC value. A worst case, WC, is shownas a base line. A best case, B Rx, shows the approximate Rx penalties (1.00 db). A best case, B Tx F, shows the approximate Tx and fiber penalties and insertion loss ( 6.48 db). The combined best cases, BC, shows that penalties and insertion losses can be reduced by 6.59 db. Note the combined penalty reduction is less than the sum of the individual cases. Penalties included in the max TxVEC cases can amount to 4.86 db to 5.17 db depending on the inclusion of Pmn in the TxVEC calculation. Inclusion to Pmpn (not shown) can add another 0.1 db to 0.2 db to the Tx VEC calculation. The max value for TxVEC should be 4.9 db to 5.3 db depending on the inclusion of Pmn & Pmpn. The min expected value for TxVEC is expected is 0.8 to 1.1 db depending on the inclusion of Pmn and Pmpn. Ottawa September 2014 Avago Technologies: 100G SR4 TxVEC Review 3

Comparison of Fiber & Filter in TxVEC results WC Reach 100 100 2 100 2 100 2 100 2 100 2 Uc 840 840 840 840 840 840 840 840 840 840 840 Uw 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 tt 21 21 21 1 1 21 21 21 21 1 1 krin 0.70 0.70 0.70 0.70 0.70 0 0 0.70 0.70 0 0 kmpn 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 Pmn 0.129 0.129 0.129 0.129 0.129 0.129 0.129 0.129 0.129 0.129 0.129 TP1 RJ (BER) 0.053 0.053 0.053 0.053 0.053 0.053 0.053 0 0 0 0 TP1 DJ 0.110 0.110 0.110 0.110 0.110 0.110 0.110 0 0 0 0 DCD 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0 0 0 0 TP3 DJ 0.247 0.247 0.247 0.247 0.247 0.247 0.247 0 0 0 0 Rx DJ 0.05 0 0 0 0 0 0 0 0 0 0 TP4 TJ 0.780 0.780 0.780 0.780 0.780 0.780 0.780 0.780 0.780 0.780 0.780 BLW 0.025 0 0 0 0 0 0 0 0 0 0 The table show comparisons of penalties between a worst case fiber and the 12.6 GHz filter used for TxVEC tests. A reference Rx replaces the worst case Rx. Depending on the case, the results based on the 12.6 GHz filter appear to slightly understate the penalties based on a worst case fiber. Consequently, the credit for a better than worst case Tx is understated. RxBW 18.05 19.34 12.6 19.34 12.6 19.34 12.6 19.34 12.6 19.34 12.6 Signal Budget 8.20 8.20 8.20 8.20 8.20 8.20 8.20 8.20 8.20 8.20 8.20 IL 1.86 1.86 151 1.86 151 1.86 151 1.86 151 1.86 151 LP Pen 6.34 5.34 5.17 2.32 2.18 4.68 4.55 3.54 3.42 0.98 0.88 Margin 0.00 1.00 1.52 4.02 4.51 1.66 2.14 2.8 3.27 5.35 5.81 Ottawa September 2014 Avago Technologies: 100G SR4 TxVEC Review 4

TxVEC Simulations Simulation results are shown above for two different Tx output signal levels, -3.0 dbm and -8.1 dbm, as observed after a 12.6 GHz LPF with 8.5 uw additive noise. Note the TxVEC result for this ideal Tx is relatively unaffected by the scope noise. This is a significant benefit of the TxVEC method. Also note that the TxVEC result for this ideal Tx is ~ 1.0 db. Ottawa September 2014 Avago Technologies: 100G SR4 TxVEC Review 5

Tx Eyes and TxVEC Results with 12.6 GHz, 9uW Plug-in (1) The above charts show eyes and TxVEC results for cases ranging from a TxVEC = 5.3 db to a TxVEC = 2.0 db. These transmitters included little to no equalization. Ottawa September 2014 Avago Technologies: 100G SR4 TxVEC Review 6

Tx Eyes and TxVEC Results with 12.6 GHz, 9uW Plug-in (2) These charts show eyes and TxVEC results for a TxVEC = 2.78 db Tx and a TxVEC = 3.77 db Tx. Here modest amounts of equalizaton were used to yield better eye openings. Ottawa September 2014 Avago Technologies: 100G SR4 TxVEC Review 7

BER with a TxVEC=4.56/5.30 db Tx & 100 m of OM4 The charts show a BER plot and the eyes and TxVEC characteristics for the transmitters used for the BER plot. Here TxVEC= 4.56 db for one and 5.30 db for the other. A worst case 100 m OM4 fiber (actually 110 m of 5023 MHzkm EBW OM4) was used to connect the Tx and Rx along with breakout jumpers and VOA. These results indicate that a 100 m OM4 link can operate using a Tx with a TxVEC = 5 db. Ottawa September 2014 Avago Technologies: 100G SR4 TxVEC Review 8

BER with a TxVEC=4.56/5.30 db Tx & 100 m of OM4 Top charts TDEC = 4.56 db J2 = 0.40 UI J4 = 0.51 UI J5 = 0.56 UI Bottom charts TDEC = 5.30 db J2 = 0.45 UI J4 = 0.56 UI J5 = 0.60 UI Ottawa September 2014 Avago Technologies: 100G SR4 TxVEC Review 9