ZipTwo LED - Zipper board with Diffuse Batwing Lens, High Output. IES File Performance Summary

Similar documents
Fixture is tested with no special conditions. No seasoning was performed in accordance with IESNA LM-79. PS-AC02 CD-SN03-S2 MT-SC01-S2 2MR97 SPR-3000

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

Number Eight Lighting Company 526 Portal Street, Cotati, CA 94931

Bartco Lighting 5761 Research Drive, Huntington Beach, CA

Number Eight Lighting Company 803/K2-HI-25-XX/DIM /FS-P-1-WH

Infinilux 5349 Zambrano St, Commerce, CA Electrical and Photometric tests as required by the IESNA test standards.

Revolution Lighting Technologies (RVLT) 2280 Ward Ave. Docks 5&6, Simi Valley, CA 93065

LM - 79 Reporting. Laboratory Information. Date of test report July 31 st, Product Information

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

IESNA LM79: 2008 Photometric Test Report

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

Photometric Test Report

PHONE: (303) FAX: (970) WEBSITE:

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

NVLAP LAB CODE:

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Fuel Pump Canopy Luminaires

NVLAP LAB CODE:

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: IRICO) 911 Denison St Markham, ON L3R 3K4 Canada

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

NVLAP LAB CODE LM Test Report. For. EiKO Global, LLC. (Brand Name: EiKO) W. 84th St, Shawnee, KS USA

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Product testing and evaluation to IES LM-79-08

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK Project No. G Date: October 29, 2010 REPORT NO CRT-001 TEST OF ONE LED DESK LAMP

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

LED Floodlight RoHS. Model: inner box: L273*W240*H165mm master carton: L549*W485*H175mm 4PCS

Report of Test LLIA A-R01*

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Test Report. Report Number: L15159 Date: Jan 6, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

PHONE: (303) FAX: (970) WEBSITE:

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU DI-24V-ES30-BK 3000K BLACK.

Photometric Test Report

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-12-BLBSC2-50-W***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-24-BLBSC2-30-W***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. INFINILINE X 120V LED Light DI-120V-INFX60

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. INFINILINE X 120V LED Light DI-120V-INFX27

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE 24V LED Tape Light DI-24V-BL35-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE 24V LED Tape Light DI-24V-BL28-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV50-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV24-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV20-90**

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE Basics 100 LED Tape Light - DI-24V-BLBSC1-63-***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-24V-BLBSC1-30-W***

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. Blaze Basics 200 LED Tapelight DI-12V-BLBSC2-27-***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. Blaze Basics 200 LED Tapelight DI-12V-BLBSC2-50-***

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Report of Test LLIA

LXT Series 2x2/2x4 LED/FLUOR

LUNERA SERIES L7 _ GEN 3

Evaluating and Specifying LED Lighting

DATASHEET. Intematix ChromaLit. Remote Phosphor Light Source. Features & Benefits. Applications and Uses

LINEAR DOWNLIGHT - PENDANT DIRECT

WEATHERPROOF LUMINAIRE

T5 LED Integrated Lamp

never recognized 7,307,391)

TLS RGBW CUT SHEET DESCRIPTION FEATURES

IESNA LM-79: Measurement and Test Report for Venture Lighting International Aurora Road, Suite A, Solon, OH 44139,United states

Vaya Cove, Color. Data sheet. Philips Lighting Rev Burlington Woods Drive Burlington, MA 01803

LIGHTING: ENCLOSED AND GASKETED AREA FLUORESCENT. Applications. Illustrated Feature. Certifications and Compliances

VIA 2 LED WALL INDIRECT ASYMMETRIC V. 2 W W W. L U M E N W E R X. C O M

Transcription:

Adaptive architectural lighting systems IES File Performance Summary The performance data in black text are confirmed through third party testing. See the following Light Laboratory report for details. The performance data in grey text are calculated by Vode. Use for reference only. ZipTwo LED - Zipper board with Diffuse Batwing Lens, High Output ZipTwo LED, 48, 3500K, Zipper board with diffuse batwing lens, high output 707-Z2-4-48-X-X-X-X-Z-HO-35-B1-X-X 2700K 3000K 3500K 4000K Efficacy - Lumens per Watt Total Lumens, 4 rail length (1219mm) Lumens per foot (305mm) Input Power (W), 4 rail length (1219mm) Watts per foot (305mm) CRI (>80min., 85 avg.) 69 4064 1016 58.6 14.7-72 4233 1058 58.6 14.7-75 4409 1102 58.6 14.7 83 78 4586 1146 58.6 14.7-08/11/15

Report No: L041508508 Date: 5/12/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Report No: L041508508 Report Prepared For: Vode Lighting 1206 E MacArthur Street Suit 3, Sonoma, CA 95476 Model Number: 707-Z2-48-Z-HO-B1-AL Test: Electrical and Photometric tests Standards Used: Appropriate part or all test guidelines were used for test performed: IESNA LM79: 2008 Approved Methods for Electrical and Photometric Measurements of Solid-State Lighting Products ANSI NEMA ANSLG C78.377: 2008 Specification of the Chromaticity of Solid State Lighting Products ANSI C82.77:2002: Harmonic Emission Limits-Related Quality Requirements for Lighting Equipment Description of Sample: Client submitted the sample. Catalog number is 707-Z2-48-Z-HO-B1-AL. Received in working and undamaged condition. No modifications were necessary. Testing Condition: Driver output set to 1403mA. Sample Arrival Date: Date of Tests: Seasoning of Sample: 5/5/15 5/11/15-5/12/15 No seasoning was performed in accordance with IESNA LM-79. Equipment List Equipment Used Model No Stock No Calibration Due Date Chroma Programmable AC Source 61604 PS-AC02 -- Yokogawa Digital Power Meter WT210 MT-EL06-S1 11/10/15 Xitron Power Analysis System 2503AH MT-EL01 10/20/15 BK Precision DC Power Supply 1747 PSDC-04 01/08/16 Fluke Digital Thermometer 52k/J MT-TP02-GC 01/05/16 LLI Type C Goniophotometer System RMG-C-MKII CD-LL04-GC -- LLI 2M Sphere 2MR97 CD-SN03-S2 -- LLI Spectroradiometer SPR-3000 MT-SC01-S2 Before Use *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 1 of 4

Report No: L041508508 Date: 5/12/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Summary Manufacturer: Model Number: Driver Model Number: Current ATHD @ 277V(%): N/A Efficacy: 75 Vode Lighting Total Lumens: 4409.94 Input Voltage (VAC/60Hz): 120.00 Input Current (Amp): 0.49 Input Power (W): 58.58 Input Power Factor: 1.00 Current ATHD @ 120V(%): 5% Color Rendering Index (CRI): 83 Correlated Color Temperature (K): 3528 Chromaticity Coordinate x: 0.4051 Chromaticity Coordinate y: 0.3937 Ambient Temperature ( o C): 25.0 Stabilization Time (Hours): 0:30 Total Operating Time (Hours): 1:20 Off State Power(W): 0.00 707-Z2-48-Z-HO-B1-AL MEAN WELL HLG-60H-36A FIG. 1 LUMINAIRE *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 2 of 4

Percent Output Report No: L041508508 Date: 5/12/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 1.0 0.8 0.6 0.4 0.2 0.0 Spectral Power 380 430 480 530 580 630 680 730 780 Wavelength(nm) Wavelength W/m 2 nm 440 0.3129 510 0.4760 580 0.9710 650 0.6251 720 0.1122 380 0.0011 450 0.6892 520 0.5498 590 0.9991 660 0.5191 730 0.0835 390 0.0012 460 0.5490 530 0.6223 600 0.9993 670 0.4202 740 0.0614 400 0.0024 470 0.3746 540 0.6955 610 0.9800 680 0.3348 750 0.0449 410 0.0094 480 0.2799 550 0.7687 620 0.9050 690 0.2625 760 0.0325 420 0.0365 490 0.3058 560 0.8446 630 0.8222 700 0.2020 770 0.0238 430 0.1120 500 0.3893 570 0.8988 640 0.7287 710 0.1535 780 0.0176 CRI & CCT x 0.4051 y 0.3937 u' 0.2344 v' 0.5125 CRI 83.30 CCT 3528 Duv 0.00135 R Values R1 81.32 R2 89.83 R3 95.80 R4 80.70 R5 80.61 R6 85.35 R7 86.81 R8 66.17 R9 17.67 R10 75.32 R11 78.04 R12 63.69 R13 83.22 R14 97.49 Y 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 510 500 490 520 480 530 470 460 440 430 380 CIE 1931 Chromaticity Diagram 540 550 560 570 580 0.4051, 0.3937 590 600 610 620 630 640 650 700 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 X *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 3 of 4

Report No: L041508508 Date: 5/12/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Methods Photometric Measurements - Goniophotometer A Custom Light Laboratory Type C Rotating Mirror Goniophotometer was used to measure candelas(intensity) at each angle of distribution as defined by IESNA for the appropriate fixture type. Ambient temperature is set to 25 o C and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25 o C throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment. Spectral Measurements - Integrating Sphere A Sensing Spectroradiometer SPR-3000, in conjunction with Light Laboratory 2 meter integrating sphere was used to measure chromaticity coordinates, correlated color temperature(cct) and the color rendering index(cri) for each sample. Ambient temperature is set to 25 o C and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25 o C throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment. Disclaimers: This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of Federal Government. Report Prepared by : Keyur Patel Test Report Released by: Test Report Reviewed by: Jeff Ahn Engineering Manager Steve Kang Quality Assurance *Attached are photometric data reports. Total number of pages: 10 *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 4 of 4

DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] L041508508 [TESTLAB] LIGHT LABORATORY, INC. [ISSUEDATE] 5/11/2015 [MANUFAC] VODE LIGHTING [LUMCAT] 707-Z2-48-Z-HO-B1-AL [LUMINAIRE] 1-1/4"L. X 48"W. X 1/4"H. LED LUMINAIRE [MORE] FROSTED LENS [BALLASTCAT] MEAN WELL HLG-60H-36A [BALLAST] INPUT: 100-277VAC, 0.30-0.64A, 50/60HZ. OUTPUT: 36VDC, 1.7A [LAMPPOSITION] 0,0 [LAMPCAT] N/A [OTHER] INDICATING THE CANDELA VALUES ARE ABSOLUTE AND [MORE] SHOULD NOT BE FACTORED FOR DIFFERENT LAMP RATINGS. [TEST CONDITION] DRIVER OUTPUT SET TO 1403mA. [INPUT] 120VAC, 58.58W [TEST PROCEDURE] IESNA:LM-79-08 CHARACTERISTICS Lumens Per Lamp N.A. (absolute) Total Lamp Lumens N.A. (absolute) Luminaire Lumens 4410 Total Luminaire Efficiency N.A. Luminaire Efficacy Rating (LER) 75 Total Luminaire Watts 58.58 Ballast Factor 1.00 CIE Type Direct Spacing Criterion (0-180) 1.60 Spacing Criterion (90-270) 1.12 Spacing Criterion (Diagonal) 1.54 Basic Luminous Shape Rectangular Luminous Length (0-180) 0.08 ft Luminous Width (90-270) 4.00 ft Luminous Height 0.00 ft Page 1

LUMINANCE DATA (cd/sq.m) Angle In Average Average Average Degrees 0-Deg 45-Deg 90-Deg 45 64968 56983 36357 55 59351 53492 34334 65 44451 42542 32364 75 25839 25969 25709 85 10411 10796 10796 Page 2

CANDELA TABULATION 0 5 10 15 20 25 30 35 40 45 0 1444 1444 1444 1444 1444 1444 1444 1444 1444 1444 5 1463 1463 1462 1461 1459 1457 1455 1452 1450 1447 10 1508 1508 1505 1502 1496 1489 1482 1473 1463 1453 15 1558 1557 1553 1547 1538 1526 1512 1496 1478 1459 20 1595 1593 1588 1579 1567 1552 1533 1510 1485 1457 25 1610 1608 1602 1592 1578 1559 1537 1510 1478 1443 30 1602 1600 1593 1583 1566 1546 1521 1491 1455 1414 35 1561 1559 1553 1543 1528 1507 1482 1450 1411 1366 40 1484 1482 1477 1469 1455 1437 1413 1382 1344 1296 45 1367 1366 1362 1354 1344 1330 1310 1282 1245 1199 50 1209 1208 1206 1202 1196 1186 1170 1147 1113 1071 55 1013 1012 1012 1011 1008 1003 993 975 948 913 60 788 789 790 791 792 791 786 775 756 729 65 559 560 561 564 567 568 567 562 551 535 70 356 357 358 360 363 365 366 364 359 351 75 199 199 200 201 203 204 205 204 202 200 80 92 92 93 93 94 95 95 95 94 93 85 27 27 27 27 27 28 28 28 28 28 90 0 0 0 0 0 0 0 0 0 0 Vert. Horizontal Angles Angles 50 55 60 65 70 75 80 85 90 0 1444 1444 1444 1444 1444 1444 1444 1444 1444 5 1444 1441 1438 1436 1434 1432 1431 1430 1430 10 1443 1433 1422 1414 1406 1399 1394 1391 1390 15 1438 1417 1398 1379 1362 1348 1337 1331 1329 20 1426 1395 1364 1333 1306 1282 1265 1254 1250 25 1404 1362 1320 1278 1239 1206 1180 1165 1159 30 1367 1317 1264 1211 1163 1120 1088 1068 1061 35 1313 1255 1194 1132 1076 1028 991 968 960 40 1239 1176 1110 1042 983 931 892 869 861 45 1142 1077 1010 942 883 834 795 773 765 50 1016 956 893 832 778 734 701 681 674 55 866 814 762 712 669 634 608 592 586 60 695 657 619 584 555 531 513 503 499 65 514 492 471 452 437 424 415 409 407 70 342 334 326 320 316 312 309 308 307 75 197 196 195 195 195 196 197 198 198 80 93 92 93 93 94 95 95 96 96 85 28 28 28 28 28 28 28 28 28 90 0 0 0 0 0 0 0 0 0 Page 3

ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt 0-20 548.61 N.A. 12.40 0-30 1200.4 N.A. 27.20 0-40 2020.05 N.A. 45.80 0-60 3645.36 N.A. 82.70 0-80 4369.31 N.A. 99.10 0-90 4409.94 N.A. 100.00 10-90 4271.73 N.A. 96.90 20-40 1471.44 N.A. 33.40 20-50 2338.91 N.A. 53.00 40-70 2129.6 N.A. 48.30 60-80 723.95 N.A. 16.40 70-80 219.66 N.A. 5.00 80-90 40.64 N.A. 0.90 90-110 0.00 N.A. 0.00 90-120 0.00 N.A. 0.00 90-130 0.00 N.A. 0.00 90-150 0.00 N.A. 0.00 90-180 0.00 N.A. 0.00 110-180 0.00 N.A. 0.00 0-180 4409.94 N.A. 100.00 Total Luminaire Efficiency = N.A.% ZONAL LUMEN SUMMARY Zone Lumens 0-10 138.22 10-20 410.39 20-30 651.79 30-40 819.65 40-50 867.47 50-60 757.84 60-70 504.30 70-80 219.66 80-90 40.64 90-100 0.00 100-110 0.00 110-120 0.00 120-130 0.00 130-140 0.00 140-150 0.00 150-160 0.00 160-170 0.00 170-180 0.00 Page 4

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD Effective Floor Cavity Reflectance 0.20 RC 80 70 50 30 10 0 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 1 109 105 101 97 107 103 99 96 98 95 93 95 92 90 91 89 87 85 2 100 92 85 80 97 90 84 79 86 81 77 83 79 75 80 77 74 71 3 91 81 73 66 89 79 72 66 76 70 65 73 68 64 71 66 62 60 4 83 72 63 56 81 70 62 56 68 61 55 65 59 54 63 58 54 52 5 77 64 55 48 74 63 54 48 61 53 48 59 52 47 57 51 47 44 6 71 57 48 42 69 56 48 42 55 47 42 53 46 41 51 45 41 39 7 65 52 43 37 64 51 43 37 50 42 37 48 41 36 47 41 36 34 8 61 47 39 33 59 47 38 33 45 38 33 44 37 32 43 37 32 30 9 57 43 35 30 55 43 35 29 42 34 29 40 34 29 39 33 29 27 10 53 40 32 27 52 39 32 27 38 31 27 37 31 26 37 31 26 25 Page 5

POLAR GRAPH 1610 1208 805 3 403 2 1 Maximum Candela = 1610 Located At Horizontal Angle = 0, Vertical Angle = 25 # 1 - Vertical Plane Through Horizontal Angles (0-180) (Through Max. Cd.) # 2 - Vertical Plane Through Horizontal Angles (90-270) # 3 - Horizontal Cone Through Vertical Angle (25) (Through Max. Cd.) Page 6