Category 5e F/UTP Euroclass D ca Cables

Similar documents
GIGALAN CAT.6 U/UTP 23AWGx4P - LSZH (EXP)

Part Number: 7965ENH Category 6 Nonbonded-Pair ScTP Cable

GIGALAN AUGMENTED CABLE CAT6A F/UTP 23AWGX4P LSZH

Table of Contents. Open Matrix System (OMS) 1-2

GenSPEED Category 5e Cables 3

CATALOGUE PRODUCT CATALOGUE CCS CONNECTIVITY & CABLING SYSTEM STRUCTURED CABLING SYSTEM. is a trademark of:

Volition TM Category 5e cable 100 Ω, FTP

Description: Pair Color Code Chart: Pair Color Chart 1 Brown White Brown 2 Orange White Orange 3 Green White Green 4 Blue White Blue.

PREMIUM 5e F/UTP PRODUCTS

CATEGORY 6A CABLING SOLUTIONS

Pre-terminated cabling system Modular cassette technology with 6x RJ45 C6 A ports

CATEGORY 5e CABLING SOLUTIONS

About Nexans 3. About Berk-Tek 4. LANmark-1000 Cat 6 UTP 5. LANmark-1000 Category 6 Plenum 6. LANmark-1000 Category 6 Riser 11

STRUCTURED CABLING SYSTEMS (SCS)

Gear up for the future.

Dimensions. Electrical Specifications. Environmental Specifications. General Specifications. Mechanical Specifications.

PRODUCT INFORMATION ETHERLINE PN FLEX. Info CPR: Article number choice under For Profinet applications Flexible use

CATEGORY 6A CABLING SOLUTIONS

Part Number: 7940A Cat 6 DataTuff, (4 pr) 23 AW G Solid BC, PO/PVC, EtherNet/IP, CMR, CMX-Outdoor

Mohawk Master Catalog

BTNS TM. FTP Compact Module

LCS3 3 DIMENSIONS OF EXCELLENCE PERFORMANCE SCALABILITY EFFICIENCY DATA CENTRE LOCAL AREA NETWORK POWERED BY SPECIALISTS

Compact Module. Category 6 FTP Cabling System

Product Description. Product Specifications. Technical Specifications. Construction and Dimensions. Conductor: Insulation: Color Chart 1:

About Nexans 3. About Berk-Tek 4. Hyper Plus 5e Cat 5e UTP 5. HyperPlus 5e Plenum 6. Hyper Plus 5e Riser 10. HyperPlus 5e Patch 14

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data

Pre-bid Supplement #01 Communications Specifications and Additional Scope Project Bid: CM Date: 05/26/2017

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

Min Dynamic Bend mm. Min Static Bend mm. EF 008 Uni4 L STA LU FS. EF 008 Uni8 L STA LU FS. EF 008 Uni12 L STA LU FS. EF 008 Uni16 L STA LU FS

Detailed Specifications & Technical Data

technicalreport MegaLine Connect100 Class E A links over 100 metres in length Data communication technology 09/2018 Classic structure 2-connector link

CAT6Plus System. Brand-Rex Limited

CATEGORY 6 CABLING SOLUTIONS

Mining and Petrochemical Fiber Optic Cables

Combining Value and Performance Like No One Else

GenSPEED 10 MTP Category 6A Cable An Unshielded 6A Cable with Superior Protection Against Alien Crosstalk

10G 6A F/UTP SYSTEM PRODUCTS 10G 6A F/UTP

SECTION TESTING OF COPPER CABLES

ACOM General Cable General Cable Canada

Cables for robot applications

Copper Solution Contents Cabinets Fiber Optic Solution

SECTION COMMUNICATIONS HORIZONTAL CABLING

Product Classification. Dimensions. Environmental Specifications. General Specifications. Material Specifications. Mechanical Specifications

SHIELDED DIGITAL CABLES (1249C SERIES)

Detailed Specifications & Technical Data

Volition TM RJ45 K5e Jacks

Detailed Specifications & Technical Data

Instrumentation Cables

Frequency ASRL(db) Attenuation Max. NEXT Power Sum (MHz) Minimum db/100m db/1000ft Minimum db/100m Minimum db/100m

LAN Cabling Systems Copper

NCB-C6SGRYR M Category 6 STP Solid Cord. Specification. Doc. Version: /09/30

CONTENTS. Product Guide 1. Multi Conductor Cable 11. Paired Cable 20. RS-232 Application Cable 27. RS-422 Application Cable 28

Structured Cabling Systems

Solarstar Electronics Industrial Co.,Ltd. 3/F,58,Junxin Rd.,Guanlan,Longhua,Shenzhen,China

OPTICAL CABLE FIBER-LAN INDOOR

Robert Burén. Product Manager. Nexans Cabling Solutions. 10G Solutions

Detailed Specifications & Technical Data

6-Connector- Channel-Link Class E A (STP)

UC Copper / Fibre summary on USPs. Zoran Borcic, Axel Koplev

MX5-F(XX)... Flat MAX module, T568A/B, rear strain relief cap

Magic Patch Patch Leads & Accessories

NEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables

HARTING Ethernet cabling cables and connectors, 4 wire

NEMA Standards Publication WC Performance Standard for Twisted Pair Premise Voice and Data Communications Cables

LCS2 Cat. 6 RJ 45 Patch panels and units

1 1/2 13.5, 625 JCASS)

SWA Cable BS6724 Steel Wire Armoured LSZH Eland Product Group A9L

STRUCTURED CABLING SOLUTIONS

ENTERPRISE COPPER SOLUTIONS

COLORED CATEGORY 5e BULK CABLE, SOLID-CONDUCTOR PATCH CABLE, & CATEGORY 5e BACKBONE CABLE

RZ1-K BS EN XLPE LSZH Flexible Cable


Tender Report for Supply and installation of LAN in *Biomedical Imaging and Bioinformatics Lab*


What really changes with Category 6

INTERNATIONAL STANDARD

PRODUCT INFORMATION. ETHERLINE EC Flex Cat.5e M8

Instrumentation & copper telecom cables

Product Catalogue. Fibre Optic Cable

System List. Structured Cabling System. In-Building RF Solution. Shield/Unshield 4pr Cable. Patch Panel. Multi-pair Cable. Patch Cord.

10G 6A UTP SYSTEM PRODUCTS 10G 6A UTP

HI-DEX PRODUCT SET DATASHEET

DINTEK LAN Cabling Systems

Empowering businesses through innovative network solutions.

Product information. OpDAT VIK with breakout cable. Product description. Illustrations. Page 1/7

Data Communication Products

GUXT. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)BH Improved Rodent Protection. Ordering Information.

Flygt Submersible Motor Cables

FREEDM Loose Tube Interlocking Armored Cables

D-COAX, Inc. D-COAX d086 Series Cable Pair. High Frequency, Skew Matched, Phase Stable Cable Pair (65 GHz)

Siam Pacific Electric Wire & Cable Co., Ltd.

PATCH CORDS, PLUGS & CABLES

1672A. Product Description. Product Specifications. Technical Specifications. Conductor. APAC Standard. Bend Radius.

SOLO ADSS Short-Span Cables, Fibers

PRODUCT INFORMATION NYY-J, NYY-O

Our cables at: ENGLISH CHANNEL TALLIN PORT MECCA METRO PULKOVO AIRPORT

QED PROFESSIONAL INSTALLATION CABLES

Continuous Flex Data Cable

FLAT AND ROUND CABLE PRODUCT DESCRIPTION DESIGN ADVANTAGES. IDC Systems Cable

Transcription:

Category 5e F/UTP Euroclass D ca Cables Datasheet: GD103437v2 APPLICATION The Brand-Rex GPF D ca cables are compliant with the European Construction Products Regulation, achieving Euroclass level D ca according to EN 13501-6. These D ca Euroclass cables also have superior levels of smoke emission, flaming droplets and acid gas production making them a versatile choice for many internal installations. The GPF D ca Euroclass cables are suited to many high density backbone installations where people safety in the case of fire is a high priority. The Brand-Rex GPF cables exceed the Category 5e performance standards. They are rated to 100MHz and are suitable for use in all Class D structured wiring cable systems. The GPF cable supports Gigabit Ethernet, PoE, PoE+ and voice transmissions at frequencies up to 100MHz. FEATURES AND BENEFITS 24 AWG Solid Annealed Copper Wire 4 Unshielded Twisted Pairs Cabled Together Aluminium Polyester screen Designed to Support all Class D protocols including Gigabit Ethernet Supports Power Over Ethernet (PoE / PoE+) Applications HFFR-LS* jacket material meets the requirements of the Construction Products Regulation (CPR) Euroclass D ca Blue Coloured Jacket to identify Euroclassification level D ca Included in the Leviton and Brand-Rex 25 Year System Warranties when used in conjunction with Leviton or Brand-Rex copper connectivity. System warranties available for qualified projects installed by certified contractors. * Halogen Free Flame Retardant Low Smoke Also available in a range of non-standard colours GPF-Dca STANDARDS Applicable Cable Standards: IEC 61156-5 and EN 50288-2-1 REACTION TO FIRE CHARACTERISTIC STANDARD RATING Single Cable Flame Rating IEC 60332-1-2 Pass Bundled Cable Flame Rating EN 50399 20.5kW source D ca Smoke Production EN 50399 s2 Flaming Droplets / Particles EN 50399 d1 Acid Gas Emission / Acidity EN 50267-2-3 a1 Euroclassification EN 13501-6 D ca s2 d1 a1 Brand-Rex 2017 Page 1 of 3 www.brand-rex.com

Category 5e F/UTP Euroclass D ca Cables Datasheet: GD103437v2 PRIMARY ELECTRICAL PARAMETERS Conductor Loop Resistance Max 19Ω/100m 16Ω/100m Conductor Resistance Unbalance Max 2% 0.1% Insulation Resistance >5GΩ.km >310GΩ.km Dielectric Strength 2500 Vdc/2secs Pass SECONDARY ELECTRICAL PARAMETERS Propagation Delay <534nsec/100m @ 100MHz 480nsec/100m @ 100MHz Delay Skew Max 45nsec/100m @100MHz 11nsec/100m @100MHz Mean Characteristic Impedance 100Ω +/- 5Ω @ 100MHz 100Ω +/- 3Ω @ 100MHz Transfer Impedance Grade 2 14mΩ/m @ 10MHz ELECTRICAL PERFORMANCE Frequency (MHz) 1 4 10 16 20 31.25 100 200 250 Insertion Loss NEXT (db) PSNEXT (db) ELFEXT PSELFEXT Return loss (db) Standard 2.1 4.0 6.3 8.0 9.0 11.4 21.4 na na Typical 2.0 3.8 6.0 7.6 8.6 10.8 20.4 30.3 34.5 Standard 65.3 56.3 50.3 47.2 45.8 42.9 35.3 na na Typical 73.3 64.3 58.3 55.2 53.8 50.9 43.3 38.8 37.3 Standard 62.3 53.3 47.3 44.2 42.8 39.9 32.3 na na Typical 70.3 61.3 55.3 52.2 50.8 47.9 40.3 35.8 34.3 Standard 63.8 51.8 43.8 39.7 37.8 33.9 23.8 na na Typical 78.8 66.8 58.8 54.7 52.8 48.9 38.8 32.8 30.8 Standard 60.8 48.8 40.8 36.7 34.8 30.9 20.8 na na Typical 76.8 64.8 56.8 52.7 50.8 46.9 36.8 30.8 28.8 Standard na 23.0 25.0 25.0 25.0 23.6 20.1 na na Typical 25.0 28.0 30.0 30.0 30.0 28.6 25.1 23.0 22.3 ACR Typical 71.3 60.5 52.3 47.6 45.2 40.0 22.9 8.5 2.9 PSACR Typical 68.3 57.5 49.3 44.6 42.2 37.0 19.9 5.5-0.1 Brand-Rex 2017 Page 2 of 3 www.brand-rex.com

Category 5e F/UTP Euroclass D ca Cables Datasheet: GD103437v2 INSTALLATION Temperature (Installation) 0 C to +50 C Min Bend Radius (Installation) 8 x Outer Diameter Temperature (Operation) -20 C to +75 C Min Bend Radius (Operation) 4 x Outer Diameter Max Tensile Load (Installation) 10kg per simplex cable Field Test NVP Value 0.68 Segregation Class Class C PRINT LEGEND Example print legend: [Length Mark]m BRAND-REX a LEVITON company GPF-Dca Cat 5e F/UTP EN 50399 Euroclass Dca s2 d1 a1 NVP 0.68 MADE IN UK [ID number] [Week/Year] STANDARD PACKAGING SPECIFICATIONS Brand-Rex Part Number Packaging Length (m) Colour Nominal Cable Diameter Nominal Cable Weight (kg/km) Reel Size Flange x Width Gross Weight (kg/item) Items Per Pallet GPF-Dca-500BU 500 Blue 6.1 40.0 400 x 315 22.0 18 GPF-Dca-1000BU 1000 Blue 6.1 40.0 465 x 390 43.1 6 Also available in a range of non-standard colours Brand-Rex is dedicated to designing, developing and manufacturing sustainable high performance structured cabling and speciality cabling solutions The information contained in this document is valid and correct at the time of issue. Brand-Rex reserves the right to modify details without notice in light of subsequent standard/specification changes and ongoing technical developments. Brand-Rex 2017 Page 3 of 3 www.brand-rex.com

Category 5e F/UTP Euroclass D ca Cables Datasheet: GD103437v2 APPLICATION The Brand-Rex GPF D ca cables are compliant with the European Construction Products Regulation, achieving Euroclass level D ca according to EN 13501-6. These D ca Euroclass cables also have superior levels of smoke emission, flaming droplets and acid gas production making them a versatile choice for many internal installations. The GPF D ca Euroclass cables are suited to many high density backbone installations where people safety in the case of fire is a high priority. The Brand-Rex GPF cables exceed the Category 5e performance standards. They are rated to 100MHz and are suitable for use in all Class D structured wiring cable systems. The GPF cable supports Gigabit Ethernet, PoE, PoE+ and voice transmissions at frequencies up to 100MHz. FEATURES AND BENEFITS 24 AWG Solid Annealed Copper Wire 4 Unshielded Twisted Pairs Cabled Together Aluminium Polyester screen Designed to Support all Class D protocols including Gigabit Ethernet Supports Power Over Ethernet (PoE / PoE+) Applications HFFR-LS* jacket material meets the requirements of the Construction Products Regulation (CPR) Euroclass D ca Blue Coloured Jacket to identify Euroclassification level D ca Included in the Leviton and Brand-Rex 25 Year System Warranties when used in conjunction with Leviton or Brand-Rex copper connectivity. System warranties available for qualified projects installed by certified contractors. * Halogen Free Flame Retardant Low Smoke Also available in a range of non-standard colours GPF-Dca STANDARDS Applicable Cable Standards: IEC 61156-5 and EN 50288-2-1 REACTION TO FIRE CHARACTERISTIC STANDARD RATING Single Cable Flame Rating IEC 60332-1-2 Pass Bundled Cable Flame Rating EN 50399 20.5kW source D ca Smoke Production EN 50399 s2 Flaming Droplets / Particles EN 50399 d1 Acid Gas Emission / Acidity EN 50267-2-3 a1 Euroclassification EN 13501-6 D ca s2 d1 a1 Brand-Rex 2017 Page 1 of 3 www.brand-rex.com

Category 5e F/UTP Euroclass D ca Cables Datasheet: GD103437v2 PRIMARY ELECTRICAL PARAMETERS Conductor Loop Resistance Max 19Ω/100m 16Ω/100m Conductor Resistance Unbalance Max 2% 0.1% Insulation Resistance >5GΩ.km >310GΩ.km Dielectric Strength 2500 Vdc/2secs Pass SECONDARY ELECTRICAL PARAMETERS Propagation Delay <534nsec/100m @ 100MHz 480nsec/100m @ 100MHz Delay Skew Max 45nsec/100m @100MHz 11nsec/100m @100MHz Mean Characteristic Impedance 100Ω +/- 5Ω @ 100MHz 100Ω +/- 3Ω @ 100MHz Transfer Impedance Grade 2 14mΩ/m @ 10MHz ELECTRICAL PERFORMANCE Frequency (MHz) 1 4 10 16 20 31.25 100 200 250 Insertion Loss NEXT (db) PSNEXT (db) ELFEXT PSELFEXT Return loss (db) Standard 2.1 4.0 6.3 8.0 9.0 11.4 21.4 na na Typical 2.0 3.8 6.0 7.6 8.6 10.8 20.4 30.3 34.5 Standard 65.3 56.3 50.3 47.2 45.8 42.9 35.3 na na Typical 73.3 64.3 58.3 55.2 53.8 50.9 43.3 38.8 37.3 Standard 62.3 53.3 47.3 44.2 42.8 39.9 32.3 na na Typical 70.3 61.3 55.3 52.2 50.8 47.9 40.3 35.8 34.3 Standard 63.8 51.8 43.8 39.7 37.8 33.9 23.8 na na Typical 78.8 66.8 58.8 54.7 52.8 48.9 38.8 32.8 30.8 Standard 60.8 48.8 40.8 36.7 34.8 30.9 20.8 na na Typical 76.8 64.8 56.8 52.7 50.8 46.9 36.8 30.8 28.8 Standard na 23.0 25.0 25.0 25.0 23.6 20.1 na na Typical 25.0 28.0 30.0 30.0 30.0 28.6 25.1 23.0 22.3 ACR Typical 71.3 60.5 52.3 47.6 45.2 40.0 22.9 8.5 2.9 PSACR Typical 68.3 57.5 49.3 44.6 42.2 37.0 19.9 5.5-0.1 Brand-Rex 2017 Page 2 of 3 www.brand-rex.com

Category 5e F/UTP Euroclass D ca Cables Datasheet: GD103437v2 INSTALLATION Temperature (Installation) 0 C to +50 C Min Bend Radius (Installation) 8 x Outer Diameter Temperature (Operation) -20 C to +75 C Min Bend Radius (Operation) 4 x Outer Diameter Max Tensile Load (Installation) 10kg per simplex cable Field Test NVP Value 0.68 Segregation Class Class C PRINT LEGEND Example print legend: [Length Mark]m BRAND-REX a LEVITON company GPF-Dca Cat 5e F/UTP EN 50399 Euroclass Dca s2 d1 a1 NVP 0.68 MADE IN UK [ID number] [Week/Year] STANDARD PACKAGING SPECIFICATIONS Brand-Rex Part Number Packaging Length (m) Colour Nominal Cable Diameter Nominal Cable Weight (kg/km) Reel Size Flange x Width Gross Weight (kg/item) Items Per Pallet GPF-Dca-500BU 500 Blue 6.1 40.0 400 x 315 22.0 18 GPF-Dca-1000BU 1000 Blue 6.1 40.0 465 x 390 43.1 6 Also available in a range of non-standard colours Brand-Rex is dedicated to designing, developing and manufacturing sustainable high performance structured cabling and speciality cabling solutions The information contained in this document is valid and correct at the time of issue. Brand-Rex reserves the right to modify details without notice in light of subsequent standard/specification changes and ongoing technical developments. Brand-Rex 2017 Page 3 of 3 www.brand-rex.com

Category 5e UTP EuroClass D ca Cables Datasheet: GD103609v4 APPLICATION Brand-Rex GPU cables exceed the Category 5e performance standards. They are rated to 100MHz and are suitable for use in all Class D structured wiring cable systems. GPU cables support Gigabit Ethernet, Power over Ethernet and voice transmissions at frequencies up to 100MHz. FEATURES AND BENEFITS 24 AWG solid annealed copper wire 4 unshielded twisted pairs cabled together Blue HFFR-LS* sheath enables cable to meet the requirements of the Construction Products Regulation (CPR) EuroClass Dca Included in the Leviton and Brand-Rex 25 Year System Warranties when used in conjunction with Leviton or Brand- Rex copper connectivity. System warranties available for qualified projects installed by certified contractors. * Halogen Free Flame Retardant Low Smoke Also available in a range of non-standard colours GPU - Dca STANDARDS Designed and constructed to give optimum electrical performance to the following standards: o ISO/IEC 11801 Class D, IEC 61156-2 o EN50173-1 and EN 50288-3-1 Supports Gigabit Ethernet Recommended for PoE standards: IEEE 802.3at types 1 & 2 (PoE & PoE+) up to 25.5W at the powered device (PD) FIRE CLASSIFICATION CHARACTERISTIC IEC STANDARD EN STANDARD CPR RATING Reaction to Fire Classification / EuroClass - EN 13501-6 Dca s2 d2 a1 Single Cable Flame Rating IEC 60332-1-2 EN 60332-1-2 Pass Smoke Emission - EN 50399 s2 Acid Gas Emission IEC 60754 EN 60754 Pass PRIMARY ELECTRICAL PARAMETERS Conductor Loop Resistance Max 19 Ω / 100m 18 Ω / 100m Conductor Resistance Unbalance Max 2% 0.1% Insulation Resistance >5GΩ.km >45GΩ.km Dielectric Strength 2500 Vdc/2secs Pass Brand-Rex 2018 Page 1 of 3 www.brand-rex.com

Category 5e UTP EuroClass D ca Cables Datasheet: GD103609v4 SECONDARY ELECTRICAL PARAMETERS Propagation Delay <534nsec/100m @ 100MHz 487nsec/100m @ 100MHz Delay Skew Max 45nsec/100m @100MHz 38nsec/100m @100MHz Mean Characteristic Impedance 100Ω ± 5Ω @ 100MHz 100Ω ± 3Ω @ 100MHz Transverse Conversion Loss (TCL) 50-10log(f)dB 65dB @ 10MHz ELECTRICAL PERFORMANCE Frequency (MHz) 1 4 10 16 20 31.25 100 200 250 Insertion Loss NEXT (db) PSNEXT (db) ELFEXT (db) PSELFEXT (db) Return Loss (db) Standard 2.0 4.1 6.5 8.2 9.3 11.7 22.0 n/a n/a Typical 1.9 3.8 6.0 7.7 8.6 10.9 20.6 30.4 34.6 Standard 65.3 56.3 50.3 47.2 45.8 42.9 35.3 n/a 38.3 Typical 76.8 67.8 61.8 58.7 57.3 54.4 46.8 42.3 40.8 Standard 62.3 53.3 47.3 44.2 42.8 39.9 32.3 n/a n/a Typical 73.8 64.8 58.8 55.7 54.3 51.4 43.8 39.3 37.8 Standard 63.8 51.8 43.8 39.7 37.8 33.9 23.8 n/a n/a Typical 81.4 69.4 61.4 57.3 55.4 51.5 41.4 35.4 33.4 Standard 60.8 48.8 40.8 36.7 34.8 30.9 20.8 n/a n/a Typical 78.4 66.4 58.4 54.3 52.4 48.5 38.4 32.4 30.4 Standard 20.0 23.0 25.0 25.0 25.0 23.6 20.1 n/a n/a Typical 24.8 27.8 29.8 29.8 29.8 28.4 24.9 22.8 22.1 ACR (db) Typical 74.9 64.0 55.8 51.1 48.7 43.4 26.2 11.9 6.2 PSACR (db) Typical 71.9 61.0 52.8 48.1 45.7 40.4 23.2 8.9 3.2 INSTALLATION Temperature (Installation) 0 C to +50 C Min Bend Radius (Installation) 8 x Outer Diameter Temperature (Operation) -20 C to +75 C Min Bend Radius (Operation) 4 x Outer Diameter Max Tensile Load (Installation) 10kg per simplex cable Field Test NVP Value 0.69 Segregation Class Class B PRINT LEGEND Example print legend: [Length Mark]m BRAND-REX a LEVITON company GPU-Dca Cat 5e U/UTP EN 50399 EuroClass Dca s2 d2 a1 NVP 0.69 MADE IN UK [ID number] [Week/Year] Brand-Rex 2018 Page 2 of 3 www.brand-rex.com

Category 5e UTP EuroClass D ca Cables Datasheet: GD103609v4 STANDARD PACKAGING SPECIFICATIONS - REELS Brand-Rex Part Number Packaging Length (m) Colour Nominal Cable Diameter Nominal Cable Weight (kg/km) Reel Size Flange x Width Gross Weight (kg/item) GPU-Dca-500BU 500 Blue 5.05 32.2 400 x 400 x 210 17.6 24 GPU-Dca-1000BU 1000 Blue 5.05 32.2 400 x 400 x 390 34.7 12 Items Per Pallet STANDARD PACKAGING SPECIFICATIONS - BOXES Brand-Rex Part Number Packaging Length (m) Colour Nominal Cable Diameter Nominal Cable Weight (kg/km) Box Size L x W x H Gross Weight (kg/item) Items Per Pallet GPU-Dca-Rlx-305BU 305 Blue 5.05 32.2 365 x 250 x 365 9.9 27 or 18 Also available in a range of non-standard colours Double or single stack pallets Brand-Rex is dedicated to designing, developing and manufacturing sustainable high performance structured cabling and speciality cabling solutions The information contained in this document is valid and correct at the time of issue. Brand-Rex a Leviton Company reserves the right to modify details without notice in light of subsequent standard/specification changes and ongoing technical developments. Brand-Rex 2018 Page 3 of 3 www.brand-rex.com

Category 5e SF/UTP Cables Datasheet: GD103688v2 APPLICATION Brand-Rex GigaPlus GPS cables exceed the Category 5e performance standards. They are rated to 100MHz and are suitable for use in all Class D structured wiring cable systems. The GigaPlus GPS cables support Gigabit Ethernet, PoE, PoE+ and voice transmissions at frequencies up to 100MHz. FEATURES AND BENEFITS 24 AWG solid annealed copper wire Polyolefin core insulation 4 unshielded twisted pairs cabled together Aluminium polyester shield Overall braided shield for improved shielding efficiency, increased mechanical robustness and heat dissipation Violet HFFR-LS* sheathing enables the cable to meet Construction Products Regulation (CPR) EuroClass Eca Designed to support all Class D protocols including Gigabit Ethernet Supports Power Over Ethernet (PoE & PoE+) applications Included in the Leviton and Brand-Rex 25 Year System Warranties when used in conjunction with Leviton or Brand- Rex copper connectivity. System warranties available for qualified projects installed by certified contractors. GigaPlus GPS * Halogen Free Flame Retardant Low Smoke Also available in a range of non-standard colours Applicable Cable Standards: IEC 61156-5 and EN 50288-2-1 MATERIAL PERFORMANCE Material Identifier Material Description HF1 Standard HFFR-LS* Flammability Rating IEC/EN 60332-1-2 EuroClass Level EN13501-6 Eca Brand-Rex 2017 Page 1 of 3 www.brand-rex.com

Category 5e SF/UTP Cables Datasheet: GD103688v2 PRIMARY ELECTRICAL PARAMETERS Conductor Loop Resistance Max 19Ω/100m 16Ω/100m Conductor Resistance Unbalance Max 2% 0.1% Insulation Resistance >5GΩ.km >310GΩ.km Dielectric Strength 2500 Vdc/2secs Pass SECONDARY ELECTRICAL PARAMETERS Propagation Delay <534nsec/100m @ 100MHz 480nsec/100m @ 100MHz Delay Skew Max 45nsec/100m @100MHz 11nsec/100m @100MHz Mean Characteristic Impedance 100Ω +/- 5Ω @ 100MHz 100Ω +/- 3Ω @ 100MHz Transfer Impedance Grade 2 14mΩ/m @ 10MHz ELECTRICAL PERFORMANCE Frequency (MHz) 1 4 10 16 20 31.25 100 200 250 Insertion Loss NEXT (db) PSNEXT (db) ELFEXT PSELFEXT Return Loss (db) Standard 2.1 4.0 6.3 8.0 9.0 11.4 21.4 na na Typical 2.0 3.8 6.0 7.6 8.6 10.8 20.4 30.3 34.5 Standard 65.3 56.3 50.3 47.2 45.8 42.9 35.3 na na Typical 73.3 64.3 58.3 55.2 53.8 50.9 43.3 38.8 37.3 Standard 62.3 53.3 47.3 44.2 42.8 39.9 32.3 na na Typical 70.3 61.3 55.3 52.2 50.8 47.9 40.3 35.8 34.3 Standard 63.8 51.8 43.8 39.7 37.8 33.9 23.8 na na Typical 78.8 66.8 58.8 54.7 52.8 48.9 38.8 32.8 30.8 Standard 60.8 48.8 40.8 36.7 34.8 30.9 20.8 na na Typical 76.8 64.8 56.8 52.7 50.8 46.9 36.8 30.8 28.8 Standard na 23.0 25.0 25.0 25.0 23.6 20.1 na na Typical 25.0 28.0 30.0 30.0 30.0 28.6 25.1 23.0 22.3 ACR Typical 71.3 60.5 52.3 47.6 45.2 40.0 22.9 8.5 2.9 PSACR Typical 68.3 57.5 49.3 44.6 42.2 37.0 19.9 5.5-0.1 Brand-Rex 2017 Page 2 of 3 www.brand-rex.com

Category 5e SF/UTP Cables Datasheet: GD103688v2 INSTALLATION Temperature (Installation) 0 C to +50 C Min Bend Radius (Installation) 8 x Outer Diameter Temperature (Operation) -20 C to +75 C Min Bend Radius (Operation) 4 x Outer Diameter Max Tensile Load (Installation) 10kg per simplex cable Field Test NVP Value 0.69 Segregation Class Class C PRINT LEGEND Example print legend: [Length Mark]m BRAND-REX a LEVITON company GPS-HF1-Eca Cat 5e SF/UTP IEC 60332-1-2 EuroClass Eca NVP 0.68 MADE IN UK [ID number] [Week/Year] STANDARD PACKAGING SPECIFICATIONS Brand-Rex Part Number Nominal Cable Diameter Nominal Cable Weight (kg/km) Reel Size Flange x Width Gross Weight (kg/item) Items Per Pallet GPS-HF1-Eca-500VT 6.3 44.9 400 x 310 24.5 18 GPS-HF1-Eca-1000VT 6.3 44.9 600 x 325 50.9 6 500 = 500m length 1000 = 1000m length Brand-Rex is dedicated to designing, developing and manufacturing sustainable high performance structured cabling and speciality cabling solutions The information contained in this document is valid and correct at the time of issue. Brand-Rex a Leviton Company reserves the right to modify details without notice in light of subsequent standard/specification changes and ongoing technical developments. Brand-Rex 2017 Page 3 of 3 www.brand-rex.com