Benchmark and Benchmark Platinum Electrical Power Guide

Similar documents
PRE-INSTALLATION ELECTRICAL POWER GUIDE


Figure 1: Device components

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

Circulating Feed Delivery System Installation Instructions for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

Table of Contents. Introduction Pin Description Absolute Maximum Rating Electrical Specifications... 4

TAC1 Telephone Entry System

NOTICE Do NOT touch circuit board components, contact can create a static discharge, which can damage the microprocessor.

DIGITAL TIME CLOCK. used with the Meal-Time Control Panel. AGRI-TIME TM Control Instruction Page 1

MASTR II BASE STATION 12/24V POWER SUPPLY 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz

Electronic 1-Circuit 7-Day Time Switch With 100-Hour Backup

Ultra Quiet Series Electric Air Handler

Model PSKIT-H540 Ultrasonic Power Supply Kit 40 khz 500 Watts

Operating Instructions Dimmer for V Incandescent Lamps

KRF EMC Filters Installation, Operation and Maintenance Manual

AE-341 SERIES PROCESS INDICATORS 2 TO 6 DIGITS 0-20 MA, 4-20 MA, 0-5V, OR 0-10V SCALED INPUT

Table of Contents 5.0 WARRANTY. 1.0 Introduction Unpacking 1.2 Repacking and Storage

STEVAL-IHM021V W, 3-phase inverter based on the L6390 and UltraFASTmesh MOSFET for speed FOC of 3-phase PMSM motor drives. Features.

Electronic 2-Circuit 24-Hour Time Switch With 100-Hour Backup

Sprite TL Quick Start Guide

STEVAL-IHM025V1. 1 kw 3-phase motor control demonstration board featuring the IGBT SLLIMM STGIPL14K60. Features. Description

/ PAT01 USER MANUAL

Model Number Structure

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Installation Manual Original Instructions - IW4001

VHF + UHF Amplified HDTV Antenna Model OA8000 & OA8001 Installation Instructions Reception Frequencies

STEVAL-IHM043V1. 6-step BLDC sensorless driver board based on the STM32F051 and L6234. Features. Description

INTRODUCTION INSTALLATION LIGHTNING RETARDING LOOPS. Figure 1. Relay Box Antenna Connections. Relay Box Cable Connections

TRF STEP-DOWN TRANSFORMER USER MANUAL

Electronic 1-Circuit Astronomic 7-Day Time Switch With 100-Hour Backup

16-Channel Headstage Omnetics IFU

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

1:4 VGA Hub EXT-VGA-144 USER S MANUAL.

Electronic 2-Circuit Astronomic 7-Day Time Switch With 100-Hour Backup

Composite Video Extender

LEVEL ADJUST POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Environmental Technology, Inc.

STEVAL-IHM008V1. BLDC & AC motor control Power board SEMITOP 2 1kW. Features. Applications

FD932DVD-LP. Installation and Operation Manual Low-Profile DVD/CD/MP3 Player MAN FD932DVD-LP. TECHNICAL SUPPORT , or

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

INSTRUCTION BOOK FOR. Lectern

Warner Photoscanner MCS-500 Series LED Photoelectric Control

Installation Manual SaVi Note Underwater LED Light

EG4015. Digital Generator Governor Controller User Manual

VS-201H VS-401H VS-801H

SQM40/41 Actuators for air and gas dampers

Active UTP Transceiver Hub Installation Guide

STEVAL-IHM024V W 3-phase inverter using the L6390 and STGDL6NC60DI for vector control. Features. Applications. Description

Garmin GC 10 Marine Camera Instructions

VGA Extender LR EXT-VGA-141LR. User s Manual

MATE3 Owner s Manual Addendum

MP-7424 Football Scoreboard with MP5000 Console

YLAA YLAA0175 AIR-COOLED SCROLL CHILLERS STYLE A, B or C (60 Hz) TON KW

9I273 01/10/2012 COU-03/0 AUTOMATIC CHANGEOVER UNIT TO BACK-UP AMPLIFIER

Cast Aluminum Circuit Breaker Interlocked Receptacle (Cutaway View)

BC-R25 Series. Burner Controllers

GeniSys Display. Contractor s Tool. Description / Applications. for the GeniSys Advanced Burner Control

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

ENGLISH Antenna Distributor

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R. EXT-VGA-CAT5-148S EXT-VGA-CAT5-148R User Manual

AGS Low profile capacitive air gap measuring sensor for rotating machines

INSTALLATION AND OPERATION INSTRUCTIONS EVOLUTION VIDEO DISTRIBUTION SYSTEM

Manual No: Revision: D. IQ Box. Software Upgrade Instructions

8-Port HDMI Splitter with Up Data SP-H User Manual V

Installation And Programming Guide

WIRING INSTRUCTIONS CROP-LINK Drip Installation

Model /29S RF Splitter

FD104CV. Installation and Operation Manual 10.4 LCD MAN FD104CV. TECHNICAL SUPPORT , or Document Number: Rev:

Colour Explosion Proof Video Camera USER MANUAL VID-C

Power Injector 1520 Series

LBS-1 (Lowrance Broadband Sounder)

VGA Extender LR EXT-VGA-141LR. User s Manual


Portable Automatic Satellite System. Model VQ2000

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

Caution. Hanging the Screen:

Installation and Operation Manual

A. Section Includes: Division 1 applies to this section. Provide GPS wireless clock system, complete.

Adire Audio ADA Series Subwoofer Amp Manual ADA300 - ADA600 - ADA1200

MaxLite LED Wall Packs (Cutoff & Standard)

TVAC20000 User manual

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

Dial Ezy INSTRUCTION MANUAL N IRRIGATION CONTROLLER 4 or 6 Station Model SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID

Instruction Manual. 2.4G Digital Wireless Four Channel Transmitter System RVS-554W. Reverse With Confidence 1

TECHNICAL SUPPORT , or FD151CV-LP Installation and Operation Manual 15.1 Low Profile LCD

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

User Manual. 1x8 S-Video Distribution Amplifier With Stereo Audio AT-SAV18

LED control gear Compact fixed output. Uconverter LCI 55 W 1400 ma O010 TOP series Ø4,4. Ordering data

FD171CV-C-4. Installation and Operation Manual. 17 HDSDI Special Mission Quad Monitor. Revision Date: 01/11/2017 Page 1 of 14.

CENTRAL BLOWER COMPANY 211 S. 7th Ave. City of Industry, CA (626) Fax (626)

STEVAL-ILL037V1. Demonstration board for the HVLED805 IC for LED power supply. Features. Description

FDCONV-HDSDI-D VER SW FDCONV-HDSDI-S VER SW

STD-525T PRECISION TIMER

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

FD70CV-M-C-6. Installation and Operation Manual. 7 Widescreen LCD /Standard Arm. Revision Date: 05/05/2017 Page 1 of 13. Rev: B

Prodigy Eclipse ECC and EH222 Service Parts EH222 Cabinet - C Series

STEVAL-ILL043V1. High end, 75 W high power factor flyback LED driver based on the L6562A with two dimmable strings. Features.

Instruction Manual Model BlockUpconverter

Portable In-Motion Automatic Satellite System. Model VQ3000

Transcription:

Pre-Installation Application Guide Benchmark and Benchmark Platinum Electrical Power Guide Benchmark Models 750 through 6000 Other documents for this product include: OMM-0115, GF-200 BMK 750-3000 Platinum Installation-Startup OMM-0116, GF-201 BMK 750-3000 Platinum Operation-Maintenance OMM-0117, GF-202 BMK 5000-6000 Platinum Installation -Startup OMM-0118, GF-203 BMK 5000-6000 Platinum Operation-Maintenance OMM-0121, GF-205 BMK 750-3000 Install-Startup OMM-0122, GF-206 BMK 750-3000 Operation-Maintenance OMM-0123, GF-207 BMK 5000-6000 Installation -Startup OMM-0124, GF-208 BMK 5000-6000 Operation-Maintenance OMM-0127, GF-205-K BMK 750K-3000K Installation-Startup KOREA OMM-0128, GF-206-K BMK 750K-3000K Operation- Maintenance KOREA OMM-0136, GF-210 BMK 750-6000 Platinum-Edge Installation-Startup OMM-0137, GF-211 BMK 750-6000 Platinum-Edge Operation-Service OMM-0138, GF-212 BMK 750-6000 Platinum-Edge Reference Manual TAG-0019, GF-2070 Benchmark Boiler Application Guide TAG-0022, GF-2050 Benchmark Vent & Combustion Air Guide TAG-0047, GF-2030 Benchmark Gas Guide Disclaimer The information contained in this manual is subject to change without notice from AERCO International, Inc. AERCO makes no warranty of any kind with respect to this material, including, but not limited to, implied warranties of merchantability and fitness for a particular application. AERCO International is not liable for errors appearing in this manual, not for incidental or consequential damages occurring in connection with the furnishing, performance, or use of these materials TAG-0048_K GF-2060 1/10/2019

1. General Benchmark (BMK) Gas Fired Boilers are fully factory wired packaged units which require simple external power wiring as part of the installation (Figure 1). This technical guide is intended to help designers provide electrical power wiring (line voltage) to Benchmark units. Control wiring details are provided in other publications, depending upon unit application. This document is intended only as a guide and therefore cannot include all possible alternatives or unit applications. In order to comply with all codes and authorities having jurisdiction, designers and installers must plan the electrical wiring carefully and execute the installation completely. Emergency shutoffs, fusible fire switches, break glass stations, and other electrical requirements should be considered and installed whenever necessary. 2. Boiler Electrical Requirements Benchmark boilers are available with the following power options: BMK Model Voltage Phase Amperage BMK 750 2000 Domestic 120 V 1 / 60 Hz 20 BMK 750 2000 International 230 V 1 / 50-60 Hz 20 BMK 2500-3000 Domestic 208-230 V 3 / 60 Hz 20 460 V 3 / 60 Hz 15 BMK 2500-3000 International 380-415 V 3 / 50-60 Hz 15 BMK 5000-6000 Domestic 208 V 3 / 60 Hz 30 460 V 3 / 60 Hz 20 BMK 5000-6000 Canada 575 V 3 / 60 Hz 20 BMK 5000-6000 International 380-415 V 3 / 50-60 Hz 20 Voltages lower than those specified in the table above will result in increased wear and premature failure of the blower motor. Wire size and type should be made per the National Electrical Code based on length and load. For all Benchmark models, the power box for field wiring connections is located in the upper right corner behind the unit front panel. All copper wire must be connected to the power box. Service Disconnect Switch Figure 1: Service Disconnect Switch Typical Location TAG-0048_K GF-2060 1/10/2019 Technical Support (800) 526-0288 Mon-Fri, 8 am - 5 pm EST Page 2 of 11

12V BOX LABEL 110 V INPUT 24 VDC FLAME ROD SIGNAL AMPLIFIER Figure 2a: Power Box Components, BMK 750 & 1000 DOMESTIC 12V For INTERNATIONAL units, Molex is plugged into 220 V Transformer Harness 220 V Transformer Harness To 220 V 24 VDC FLAME ROD SIGNAL AMPLIFIER BOX LABEL 220 V INPUT Figure 2a: Power Box Components, BMK 750 & 1000 INTERNATIONAL TAG-0048_K GF-2060 1/10/2019 Technical Support (800) 526-0288 Mon-Fri, 8 am - 5 pm EST Page 3 of 11

BOX LABEL 110 V INPUT 24 VDC 12 V FLAME ROD SIGNAL AMPLIFIER Figure 3a: Power Box Components, BMK 1500 2000 DOMESTIC For INTERNATIONAL units, Molex is plugged into 220V Transformer Harness 220 V Transformer Harness 24 VDC 12V FLAME ROD SIGNAL AMPLIFIER To 220V BOX LABEL 220 V INPUT Figure 3b: Power Box Components, BMK 1500 2000 INTERNATIONAL TAG-0048_K GF-2060 1/10/2019 Technical Support (800) 526-0288 Mon-Fri, 8 am - 5 pm EST Page 4 of 11

24 VDC 12 V BOX LABEL 208 V INPUT BMK 2500-3000 BOX LABEL 208 V INPUT BMK 5000-6000 BOX LABEL 460 V INPUT Figure 4a: Power Box Components, BMK 2500 6000 DOMESTIC TAG-0048_K GF-2060 1/10/2019 Technical Support (800) 526-0288 Mon-Fri, 8 am - 5 pm EST Page 5 of 11

24 VDC 12V BOX LABEL, 380 to 415 V INPUT Figure 4b: Power Box Components, BMK 2500 6000 INTERNATIONAL 3. Provisions for Service Designers must provide emergency shutoffs and other devices to satisfy electrical codes. It is also recommended to provide an electrical shutoff disconnect switch of suitable load carrying characteristics on or near each BMK boiler. No electrical boxes or field components should be mounted to the surface of the boiler or where they would interfere with the removal of the side or top panels for maintenance. The service disconnect switch should be mounted near the unit, as illustrated in Diagram 1. Wiring conduit, EMT, or other wiring paths should not be secured to the unit, but supported externally. Electricians should be instructed as to where the wiring conduit should be located, such as away from the relief valve discharge, drains, etc. All electrical conduit and hardware should be installed so that it does not interfere with the removal of any covers, inhibit service or maintenance, or prevent access between the unit and walls or another unit. TAG-0048_K GF-2060 1/10/2019 Technical Support (800) 526-0288 Mon-Fri, 8 am - 5 pm EST Page 6 of 11

4. Boiler Wiring A dedicated protected circuit should be provided from the power source to the boiler. No other electrical devices should be permanently wired on the same circuit. The protected circuit and circuit breaker switch must be sized for the amperage values below. An emergency switch (electrical shutoff) must be in series with power to the unit. DOMESTIC UNITS INTERNATIONAL UNITS BMK Model Diag. Voltage/Phase/Frequency Amps Wires Diag. Voltage/Phase/Frequency Amps Wires 750 2000 1 120V / 1 / 60 Hz@ 20 A 3 1b 220V / 1 / 50-60 Hz 20 A 3 2500/3000 2 208-230V / 3 / 60 Hz 20 A 5 2500/3000 3a 460V / 3 / 60 Hz 15 A 4 3b 380V / 1 / 50-60 Hz 15 A 4 5000/6000 4 208V-230 / 3 / 60 Hz 30 A 4 5000/6000 5 460V or 575V / 3 / 60 Hz 20 A 4 5b 380V / 3 / 50-60 Hz 20 A 4 For applicable wiring connections, refer to the schematic diagrams below. 1 POLE 20 AMP CIRCUIT DISCONNECT SWITCH 1 POLE 20 AMP 120V / 1 / 60 Hz Diagram 1a - BMK 750 2000: 120V / 1 / 60 Hz Wiring Schematic 3 Wire DOMESTIC 1 POLE 20 AMP CIRCUIT DISCONNECT SWITCH 1 POLE 20 AMP 220V / 1 / 50-60 Hz Diagram 1b - BMK 750 2000: 220V / 1 / 50-60 Hz Wiring Schematic 3 Wire INTERNATIONAL TAG-0048_K GF-2060 1/10/2019 Technical Support (800) 526-0288 Mon-Fri, 8 am - 5 pm EST Page 7 of 11

208-230V / 3 / 60 Hz Diagram 2 - BMK 2500/3000: 208-230V / 3 / 60 Hz Wiring Schematic- 5 Wire DOMESTIC 460V / 3 / 60 Hz Diagram 3a - BMK 2500/3000: 460V / 3 / 60 Hz Wiring Schematic- 4 Wire DOMESTIC 380V / 3 / 50-60 Hz Diagram 3b- BMK 2500/3000: 380 / 3 / 50-60 Hz Wiring Schematic- 4 Wire INTERNATIONAL TAG-0048_K GF-2060 1/10/2019 Technical Support (800) 526-0288 Mon-Fri, 8 am - 5 pm EST Page 8 of 11

208V / 3 / 60 Hz Diagram 4: BMK 5000/6000: 208V / 3 / 60 Hz Wiring Schematic- 4 Wire DOMESTIC 3 POLE 20 AMP CIRCUIT DISCONNECT SWITCH 3 POLE 20 AMP 460V / 3 / 60Hv or 575V / 3 / 60 Hz Diagram 5a: BMK 5000/6000: 460V or 575V / 3 / 60 Hz Wiring Schematic- 4 Wire DOMESTIC 3 POLE 20 AMP CIRCUIT DISCONNECT SWITCH 3 POLE 20 AMP 380V / 3 / 50-60Hv Diagram 5b: BMK 5000/6000: 380V / 3 / 50-60 Hz Wiring Schematic- 4 Wire INTERNATIONAL TAG-0048_K GF-2060 1/10/2019 Technical Support (800) 526-0288 Mon-Fri, 8 am - 5 pm EST Page 9 of 11

5. Multiple Unit Wiring Whenever multiple units are installed within the same mechanical spaces, electrical code requirements call for a single electrical shutoff for emergency use. It is the responsibility of the electrical designer to comply with local codes and regulations affecting an individual installation. TAG-0048_K GF-2060 1/10/2019 Technical Support (800) 526-0288 Mon-Fri, 8 am - 5 pm EST Page 10 of 11

Change Log: Date Description Changed by 02/16/2017 1/10/2019 Rev J: PIR 998-1: Addition Of 575V Option For BMK 6000. Clarified Power Options in Section 2 and in Diagrams. DIR 359: Addition restriction added to section 4 Boiler Wiring. Reformatted per new design. Rev K: DIR 18-60: Added BMK 5000 to diagrams that apply to BMK 6000, reformatted per current design standard. DIR 19-03: Added International (380V) power option. Chris Blair & Curtis Harvey Chris Blair AERCO International, Inc., 2019 TAG-0048_K GF-2060 1/10/2019 Technical Support (800) 526-0288 Mon-Fri, 8 am - 5 pm EST Page 11 of 11