SERIES PATENTED DUAL PATH PROTECTION SM. Global LIGHTNING PRODUCT INFORMATION BE PREPARED, BE PROTECTED.

Similar documents
PRODUCT CATALOGUE 2010 Accessories

Broadband Quadplexer Combiner

HexPort Multi-Band Antenna

Small Business - Privately Held Company. Headquartered in Westford, MA USA. Founded in Years of Design Excellence. Moved to New Facility in

Series SK (2.92 mm) prec. submini. connectors

2W SDARS ECHO Repeater

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

HDRFI Series Tensolite High-Performance Cable & Interconnect Systems. High Density RF Interconnect

Fibre Optic Modem ODW-622

SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver

Directional Couplers and Splitters

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

SUHNER QMA SUBMINIATURE CONNECTORS

Orbital 4400X & 4400XI Series X-Band Ext Ref LNB

Orbital 694XA Series. Ka BAND EXTERNAL REFERENCE LNB with rear anchor posts. Wide range of Frequencies and Bandwidths LNB 1855R 1000 XA-WN60

Multiple Band Outdoor Block Up- and Downconverters

ODW-621. RS-232 Point-to-point applications

4400X Series. Orbital. X-Band Ext Ref LNB. MIL Spec MIL-STD A, 45 db internal filter LNB630S-500X-WN60-G12. Orbital Features: Orbital Specs:

AMERICAN NATIONAL STANDARD

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure. 1

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

NanoStation NanoStation. NanoStation. Compact, Hi-Power, 2x2 MIMO AirMax TDMA Station. *Respaldo y Garantía. Datasheet

Amplifier Systems. 1:1, Dual 1:1 and 1:2 Redundant Low-Noise. Back to

FREQUENCY CONVERTER. MULTIPLE OUTPUT WIDEBAND Ku AND Ka DOWNCONVERTERS. Narda-MITEQ FEATURES OPTIONS

Industrial Wi-Fi Access Point and Client - DM500

X-Band Redundant LNB Systems

User Manual Entry Line Industrial Fast Ethernet Switch 4x 10/100Base-TX, 1x 100Base-X Fiber Port 4x PoE+ up to 30W

Reverse polarity connectors

FREQUENCY CONVERTER HIGH-PERFORMANCE OUTDOOR BLOCK UP AND DOWNCONVERTERS. Narda-MITEQ 1 FEATURES OPTIONS

DA E: Series of Narrowband or Wideband Distribution Amplifiers

SignalOn Series. L-Band Power Inserter Module INSTALLATION & OPERATION MANUAL. 1.2 GHz. D3.

D-COAX, Inc. D-COAX d086 Series Cable Pair. High Frequency, Skew Matched, Phase Stable Cable Pair (65 GHz)

Non Magnetic Connectors Product Catalog

LONWORKS Fibre Optic Converter

Orbital Ka-ISO. Ext Ref Ka LNB with integrated isolator. Orbital Research Ltd Marine Drive, White Rock, BC. Canada V4B 1A9

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

Rack mounted telephone- and leased line modem for industrial applications

Spec Sheet. InterReach Fusion Wideband 2.5 GHz WiMAX. In-Building Wireless Networking System. Product Highlights

IMC-21A Series. Industrial 10/100BaseT(X) to 100BaseFX media converters. Introduction. Specifications. Ethernet Media Converters and Extenders

Type "N" Connectors. Type "N" Interface Dimensions

Surge-Gap Drop Amplifier 1 GHz with 42/54 MHz Split

High Performance Outdoor Test Translators

Remote Tuner Options for the DXE-MBVE-1 Vertical Antenna

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Wideband LNB: 2.4 GHz

R-1580A Microwave Downconverter. Product Brochure

Installation. SAPTF33xx-1xx in the Network. Standard Configuration

Fibre Optic Modem ODW-611

Model /29S RF Splitter

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

JD725A Cable and Antenna Analyzer - Dual Port

MAXX BOX. MX102/202 Series. MAXX Box

Model FS-4608R. Features. Overview

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

10 GHz to 26 GHz, GaAs, MMIC, Double Balanced Mixer HMC260ALC3B

DA : Series of Narrowband or Wideband Distribution Amplifiers

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

LONWORKS Fibre Optic Router

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

GPS4000. GPS Time Receiver System. User Manual Version 1.1. World Time Solutions. World Time Solutions Limited

Ku-Band Redundant LNB Systems

A449-6S 70 CENTIMETER FM YAGI ANTENNA MHz

FREQUENCY CONVERTER 1/3 RACK-MOUNTED BLOCK CONVERTER. Narda-MITEQ FEATURES OPTIONS. Unit shown with Option 17. Unit shown without Option 17

Ka-Band Outdoor Block Upconverters and Low-Noise Block Downconverters

HN Connectors. Automatic Connector. Introduction. Contents. 631/ FAX 631/

HDMI Over IP Extender Kit - 4K

ModuMAX SSPA Systems. C, X, and Ku Bands. Completely modular solid-state power amplifier systems for world-wide satellite communications

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

C-Band Redundant LNB Systems

Requires half the number of feeder cables

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

R&S ADMC8 Multicoupler Active UHF multicoupler for 8-port ATC signal distribution

Features. = +25 C, As a Function of LO Drive & Vdd. IF = 1 GHz LO = -4 dbm & Vdd = +4V

Keysight N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz High Performance Power Limiters. Technical Overview

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Features. Parameter Min. Typ. Max. Min. Typ. Max. Units

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

2x2 HDMI Matrix Switch - 4K with Fast Switching and Auto-Sensing

Agilent N9355/6 Power Limiters 0.01 to 18, 26.5 and 50 GHz

Model FS-HD4616VPS-36VDC. Features

User Manual POE. Twisted Pair POE Extender

Synthesized Block Up- and Downconverter

CS Series Motorized Coaxial Transfer Switches

AMERICAN NATIONAL STANDARD

Filters for Power Lines (Low Leakage Current)

Smart Bias Tees, Configurations and Practical Usage

Stevens SatComm FAQs For use with SatCommSet or Terminal Setup programs

Typical applications:

= +25 C, IF= 100 MHz, LO = +15 dbm*

Drop Passives: Splitters, Couplers and Power Inserters

= +25 C, IF= 100 MHz, LO = +15 dbm*

User Manual DVM-HDBT-EX3

HDMI over CAT5 Extender with IR and Serial - HDBaseT Extender - 4K

FREQUENCY CONVERTER. MULTIPLE WIDEBAND Ku AND Ka UPCONVERTERS. Narda-MITEQ FEATURES OPTIONS

COHERENCE ONE PREAMPLIFIER

INTER SERIES ADAPTERS INTRODUCTION & 2.4 MM, 2.9 MM INTER SERIES

Instrumental technique. BNC connector

PiMPro Rack Mount Analyzer

R&S HF907DC SHF Downconverter Specifications

User Manual RTHDBT402PT & RTHDBT402PR

Transcription:

TM PATENTED DUAL PATH PROTECTION SM PRODUCT INFORMATION Global LIGHTNING Solutions The GX Series radio frequency DC-pass filter protectors are ideal for RF coaxial applications where DC is required. The GX Series can be used on GPS radios, and active tower mounted electronic equipment that operate in the range of 2 to 3,700 MHz. The GX Series is available in a multitude of connector configurations each exhibiting low return loss, insertion loss and let through voltage. BE PREPARED, BE PROTECTED.

Features Patented Dual Path RF+DC Protection Multi-strike Capable Industry s Best RF Performance Fully Weatherized Housing Wide Bandwidth Maintenance Free Industry s Lowest throughput Energy 10 Year Warranty GX, DC pass, Integrated Bias-T Protection Easy excellent Bulkhead Grounding Let through Energy Value Mounting Protection Insertion Loss VSWR DGXZ DC PASS PRODUCT INFORMATION GXZ DC PASSING Part # Frequency Connector Connector Operating Max RF Power Insertion Return Surge (Max) User Drawing # (MHz) Surge Side Protected Side DC Voltage (Watts) @20 C Loss (db) Loss (db) Multi-Strike Current ** BGXZ-60NFNM-AT* 40-400 N Female N Male +/-60 100 <0.25 db* >26dB* 20kA @ 8x20µs 4 Amps 12 BGXZ-60NFNF-AT* 40-400 N Female N Female +/-60 100 <0.25 db* >26dB* 20kA @ 8x20µs 4 Amps 11 BGXZ+24NFNF-A* 30-400 N Female N Female +24 40 <0.1 db* >26dB 3kA @ 8x20µs 4 Amps 11 BGXZ-60TFTM-A* 5-10, 50-400 TNC Female TNC Male -60 40 <0.1 db* >26dB* 3kA @ 8x20µs 4 Amps 1 CGXZ+15NFNF-A 400-1200 N Female N Female 15 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 11 CGXZ+24DMDF-A 400-1200 Din Male Din Female 24 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 4 CGXZ+24NFNF-A 400-1200 N Female N Female 24 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 11 CGXZ+24NMNF-A 400-1200 N Male N Female 24 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 5 CGXZ+36NFNF-A 400-1200 N Female N Female 36 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 11 CGXZ+48NFNF-A 400-1200 N Female N Female 48 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 11 CGXZ-48NFNF-A 400-1200 N Female N Female -48 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 11 DGXZ+06DFDF-A 800-2500 Din Female Din Female 6 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 14 DGXZ+06DFDM-A 800-2500 Din Female Din Male 6 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 6 DGXZ+06DMDF-A 800-2500 Din Male Din Female 6 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 4 DGXZ+06NFNF-A 800-2500 N Female N Female 6 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 11 DGXZ+06NFNM-A 800-2500 N Female N Male 6 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 12 DGXZ+06NMNF-A 800-2500 N Male N Female 6 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 5 DGXZ+06TFTF-A 800-2500 TNC Female TNC Female 6 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 13 DGXZ+15DFDF-A 800-2500 Din Female Din Female 15 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 14 DGXZ+15DFDM-A 800-2500 Din Female Din Male 15 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 6 DGXZ+15DMDF-A 800-2500 Din Male Din Female 15 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 4 DGXZ+15NFNF-A 800-2500 N Female N Female 15 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 11 DGXZ+15NFNM-A 800-2500 N Female N Male 15 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 12 DGXZ+15NMNF-A 800-2500 N Male N Female 15 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 5 DGXZ+15TFTF-A 800-2500 TNC Female TNC Female 15 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 13 DGXZ+24DFDF-A 800-2500 Din Female Din Female 24 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 14 DGXZ+24DFDM-A 800-2500 Din Female Din Male 24 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 6 DGXZ+24DMDF-A 800-2500 Din Male Din Female 24 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 4 DGXZ+24NFNF-A 800-2500 N Female N Female 24 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 11 DGXZ+24NFNM-A 800-2500 N Female N Male 24 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 12 DGXZ+24NMNF-A 800-2500 N Male N Female 24 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 5 DGXZ+36NMNF-A 800-2500 N Female N Male 36 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 5 DGXZ+48DFDF-A 800-2500 Din Female Din Female 48 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 14 DGXZ+48NFNF-A 800-2500 N Female N Female 48 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 11 DGXZ+48NMNF-A 800-2500 N Male N Female 48 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 5 DGXZ+60NMNF-A 800-2500 N Male N Female 60 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 5 DGXZ-48DFDF-A 800-2500 Din Female Din Female -48 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 14 DGXZ-48DFDM-A 800-2500 Din Female Din Male -48 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 6 DGXZ-48DFDM-A 800-2500 Din Female Din Male -48 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 6 DGXZ-48NFNF-A 800-2500 N Female N Female -48 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 11 DGXZ-60NFNF-A 800-2500 N Female N Female -60 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 11 DGXZ-72DFDF-A 800-2500 Din Female Din Female +/-72 300 <0.1 db >26dB 20kA @ 8x20µs 6 Amps 14 DGXZ-72DFDM-A 800-2500 Din Female Din Male +/-72 300 <0.1 db >26dB 20kA @ 8x20µs 6 Amps 6 * Consult www.polyphaser.com for complete telemetry frequency, insertion loss and return loss specifications. ** Drawings subject to change. Go to www.polyphaser.com for the most up-to-date drawings. BE PREPARED, BE PROTECTED. 2

OUR PHILOSOPHY Our philosophy has always been to manufacture surge protection that far surpasses our customer s expectations. The GX Series is a result of this philosophy. The GX Series is like no other DC-passing protector. It has separate circuits for RF-path protection and DC pass protection. This extra filtering allows us to provide the lowest let through voltage in the industry. The GX Series is the protector to which all others are compared, and is the standard protector for GPS and tower mounted equipment. Specs Environmental Electrical Fully weatherized housing meets IEC 60529 IP67 Surge Throughput Energy: <15µJ @ 6Vdc to 610µJ @ 60Vdc Meets Bellcore #TA-NWT-00487 (Procedure 4.11) (4kV/2kA 8x20µs waveform) 120 MPH wind driven rain IEC 61000-4-5, 10/350µs @ 5kA IEC 61000-4-5, 8/20µs @20kA Insertion loss 0.1dB Typical DC Resistance Temperature Vibration Relative Humidity <0.1 Ω Typical -50 C to +85 C Storage and Operating 1G @ 5Hz to 500Hz 0 to 95% GXJ BIAS-TEE INJECTOR PRODUCT INFORMATION HIGH POWER Part # Frequency (MHz) BIAS-T INJECTORS AND LIGHTNING PROTECTORS Connector Surge Connector Protected Operating DC Voltage Max RF Power (Watts) @20 C Insertion Loss (db) Return Loss (db) Surge (Max) Multi-Strike User Current Injector Port Drawing # Equipment Side ** CGXJ+15NFNF-A 400-1200 N Female N Female 15 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 15 CGXJ+15NFNM-A 400-1200 N Female N Male 15 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 2 CGXJ+36DFDM-A 400-1200 Din Female Din Male 36 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 10 CGXJ+36NFNF-A 400-1200 N Female N Female 36 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 15 CGXJ+36NFNM-A 400-1200 N Female N Male 36 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 2 CGXJ+36NMNF-A 400-1200 N Male N Female 36 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 3 DGXJ+15DFDM-A 800-2500 Din Female Din Male 15 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 10 DGXJ+15DMDF-A 800-2500 Din Male Din Female 15 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 7 DGXJ+15NFNF-A 800-2500 N Female N Female 15 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 15 DGXJ+24DFDF-A 800-2500 Din Female Din Female 24 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 9 DGXJ+24DFDM-A 800-2500 Din Female Din Male 24 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 10 DGXJ+24DFNM-A 800-2500 Din Female N Male 24 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 8 DGXJ+24DMDF-A 800-2500 Din Male Din Female 24 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 7 DGXJ+24NFNF-A 800-2500 N Female N Female 24 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 15 DGXJ+24NFNM-A 800-2500 N Female N Male 24 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 2 DGXJ+36DFDF-A 800-2500 Din Female Din Female 36 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 9 DGXJ+36DFDM-A 800-2500 Din Female Din Male 36 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 10 DGXJ+36DFNM-A 800-2500 Din Female Din Male 36 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 8 DGXJ+48NFNF-A 800-2500 N Female N Female 48 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 15 DGXJ-48DFDM-A 800-2500 Din Female Din Male -48 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 10 DGXJ-48NFNF-A 800-2500 N Female N Female -48 300 <0.1 db >26dB 20kA @ 8x20µs 4 Amps SMA Female 15 SGXJ+24NFNF-SN 3200-3700 N Female N Female 24 300 <0.2 db >20dB 20kA @ 8x20µs 4 Amps SMA Female 15 Part # Frequency (MHz) GXH HIGH POWER PRODUCT INFORMATION Connector Surge Connector Protected Operating DC Voltage Max RF Power (Watts) @20 C Insertion Loss (db) Return Loss (db) Surge (Max) Multi-Strike User Current DGXH+24DFDF-A 800-2500 Din Female Din Female 24 500 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 14 DGXH+24DFDM-A 800-2500 Din Female Din Male 24 500 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 6 DGXH+24DMDF-A 800-2500 Din Male Din Female 24 500 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 4 DGXH+48DFDF-A 800-2500 Din Female Din Female 48 500 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 14 DGXH+48DFDM-A 800-2500 Din Female Din Male 48 500 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 6 DGXH+48DMDF-A 800-2500 Din Male Din Female 48 500 <0.1 db >26dB 20kA @ 8x20µs 4 Amps 4 * Consult www.polyphaser.com for complete telemetry frequency, insertion loss and return loss specifications. ** Drawings subject to change. Go to www.polyphaser.com for the most up-to-date drawings. Drawing # ** 3 VISIT: WWW.POLYPHASER.COM/GX FOR MORE INFORMATION

DETAILED SPECS GX INSTALLATION TYPICAL BULKHEAD GROUNDING TYPICAL FLANGE MOUNTING WARNING! It is very important that this unit be grounded to a low impedance (low R and low L) ground system in order to work properly. We strongly recommend this ground be interconnected to the tower ground and power ground to form one system. To minimize in-air interconnect inductance to the ground system since skin effect is present, use as straight and large a surface area copper strap as possible. Keep bends in copper strap to an 8.0" [203.2mm] radius or larger. NOTE: O-Ring and/or hardware is supplied as a hardware kit with each unit. VISIT: WWW.POLYPHASER.COM/GX FOR MORE INFORMATION 4

GX GROUNDING THERE ARE THREE PREFERRED METHODS FOR GROUNDING THE GX PROTECTOR. GROUNDING WITH THE GX The GX Series comes equipped with an integrated lid and mounting flange that can be used for grounding. The flange incorporates a captive 8mm PEM stud. In order to effectively ground this device we recommend using a 6 AWG ring terminal as shown. The ring terminal and wire are not included with the protection device and should be purchased separately. GROUNDING WITH A TERMINAL LUG The GX Series device can also be grounded using an N (Part # TLN) or Din (Part# TLD) terminal lug as shown. Hardware for attaching a terminal lug as shown is included with the device. However, the terminal lug is not included and must be purchased separately. GROUNDING WITH A COPPER STRAP Using a flat copper strap is the most effective way to drain surge energy to the ground plane. When used in conjunction with a single point grounding system, such as the PB and PEEP grounded entry panels, the copper strap is especially effective in considerably reducing, and in some cases eliminating, surge currents to the equipment. If you wish to use a 1-½" flat copper strap (Part# CS112-25) to ground the GX Series to a grounding plane, it will be necessary to purchase the 9400-0413 hardware package for each end of the strap. This hardware package includes the nuts, bolts, and sandwich plate. This method is the preferred method for effective surge drainage. IMPORTANT NOTE: When grounding the GX Series to the PEEP grounding system a 6AWG grounding wire is acceptable if less than 12 inches. When not using a PEEP grounding system a Uni-Kit cable grounding kit must be used to effectively drain surge energy from the shield prior to the building cable entry point. Also ask for our accessories and grounding catalog for: Single Point Ground Entry Panels Cable Shield Grounding Kits Tower Mounting Kits Weatherization Kits 5 BE PREPARED, BE PROTECTED.

DETAILED SPECS DRAWING 5 DRAWING 4 DRAWING 3 DRAWING 2 DRAWING 1 BGXZ-60TFTM-A CGXJ+15NFNM-A CGXJ+36NFNM-A DGXJ+24NFNM-A CGXJ+36NMNF-A CGXZ+24DMDF-A DGXZ+06DMDF-A DGXZ+15DMDF-A DGXZ+24DMDF-A DGXH+24DMDF-A DGXH+48DMDF-A CGXZ+24NMNF-A DGXZ+06NMNF-A DGXZ+15NMNF-A DGXZ+24NMNF-A DGXZ+36NMNF-A DGXZ+48NMNF-A DGXZ+60NMNF-A BE PREPARED, BE PROTECTED. 6

DRAWING 10 DRAWING 9 DRAWING 8 DRAWING 7 DRAWING 6 DGXZ+06DFDM-A DGXZ+15DFDM-A DGXZ+24DFDM-A DGXZ-48DFDM-A DGXZ-48DFDM-A DGXZ-72DFDM-A DGXH+24DFDM-A DGXH+48DFDM-A DGXJ+15DMDF-A DGXJ+24DMDF-A DGXJ+24DFNM-A DGXJ+36DFNM-A DGXJ+24DFDF-A DGXJ+36DFDF-A CGXJ+36DFDM-A DGXJ+15DFDM-A DGXJ+24DFDM-A DGXJ+36DFDM-A DGXJ-48DFDM-A 7 VISIT: WWW.POLYPHASER.COM/GX FOR MORE INFORMATION

DETAILED SPECS DRAWING 15 DRAWING 14 DRAWING 13 DRAWING 12 DRAWING 11 BGXZ-60NFNF-AT BGXZ+24NFNF-A CGXZ+15NFNF-A CGXZ+24NFNF-A CGXZ+36NFNF-A CGXZ+48NFNF-A CGXZ-48NFNF-A DGXZ+06NFNF-A DGXZ+15NFNF-A DGXZ+24NFNF-A DGXZ+48NFNF-A DGXZ-48NFNF-A DGXZ-60NFNF-A BGXZ-60NFNM-AT DGXZ+06NFNM-A DGXZ+15NFNM-A DGXZ+24NFNM-A DGXZ+06TFTF-A DGXZ+15TFTF-A DGXZ+06DFDF-A DGXZ+15DFDF-A DGXZ+24DFDF-A DGXZ+48DFDF-A DGXZ-48DFDF-A DGXZ-72DFDF-A DGXH+24DFDF-A DGXH+48DFDF-A CGXJ+15NFNF-A CGXJ+36NFNF-A DGXJ+15NFNF-A DGXJ+24NFNF-A DGXJ+48NFNF-A DGXJ-48NFNF-A SGXJ+24NFNF-SN VISIT: WWW.POLYPHASER.COM/GX FOR MORE INFORMATION 8

GX LID BRACKET ORIENTATION The lid for the GX is part of the tuning circuit and should never be removed; therefore, it is imperative that the correct lid configuration be selected at the time of order. Below are depictions of all of the various orientations of the GX lid. You can change the suffix of the part number to reflect a different configuration, e.g., DGXZ+06NFNF-A would have the mounting flange tucked under the device, in comparison, the DGXZ+06NFNF-D has the rotated lid 180 degrees away from the device. 9 BE PREPARED, BE PROTECTED.

BE PREPARED, BE PROTECTED. SX The SX radio frequency DC-blocked filter protectors are ideal for RF coaxial applications where DC is not required. The SX can be used on high-powered RF feeder lines in the range of 350 to 2,800 MHz, as well as low-powered microwave sites at 2 to 10 GHz. The SX is available in a multitude of connector configurations each exhibiting low return loss, insertion loss and let through voltage. SPIKEGUARD SpikeGuard is leading a revolution in the straight gas tube protection market by bringing together a smaller profile, superior RF performance, competitive pricing and immediate availability through our vast partner network. AIRSMART AirSmart is a multi-faceted product line that not only facilitates communication between non-aisg legacy tower mounted equipment and AISG compatible base stations; but acts as a bias-tee, lightning protector, in addition to providing monitoring functions through a high speed RS485 data interface. DATA Keep your high-speed data networks protected from lightning by using the NetGuard and the IX Series protectors. The NetGuard is a series of RJ45 plug-in protectors for indoor use; and the IX is a series of hard-wired protectors used primarily for outdoor applications. Both the NetGuard and the IX work on POE, T1, DSL, Ethernet, and RS485 applications. The NetGuard NXG series is an RJ45 plug-in protector for indoor Gigabit Ethernet applications. For outdoor applications, use the GigaGuard high-speed data protector. BE PREPARED, BE PROTECTED. 10

ABOUT GX WHY SHOULD YOU USE A GX PROTECTOR? If you are like most of our customers, you want to spend your time doing more important things than driving to a remote site, climbing a tower, or opening a cell site just to change a single protection device that has failed or has a large amount of VSWR. If this is you, then the GX Series is your answer. The GX Series is an established protector for GPS receivers and applications that require a DC voltage for tilt antennas or tower mounted amplification. The GX Series was engineered to perform in the harsh cell site environment, so it was built to last and requires no maintenance. Yet, some of our competitors will tell you that their protectors work just as well. Well they are wrong! What separates the GX Series from the alternative gastube or hybrid quarterwave stub is its performance and protection. The GX Series is a multistage protector, unlike the quarterwave stub and a straight gastube protector. The multiple stages of the GX Series allow it to dissipate a surge through a series of protection elements while simultaneously isolating the DC circuit from the surge. This isolation ensures that the RF and the DC portion of the signals are protected, filtered and then recollected and distributed to the radio as a clean and protected signal. No other protector on the market can do this. The quarterwave stub by its nature is a DC short device, so in order to make it pass DC voltage, competitors introduced a gastube, which weakens the protection (slow turn-on, higher energy let-through) as the device is now basically a gastube protector with an inductive element. Both the gastube and the hybrid quarterwave allow copious amounts of energy through to your equipment. The GX Series, on the other hand, does not. The GX Series is the choice of RF professionals. The GX Series is built specifically for you, by engineers who truly understand the RF environment and the peace of mind that comes from complete protection. 11 VISIT: WWW.POLYPHASER.COM/GX FOR MORE INFORMATION

TM Industry s best RF performance Ultra-wide bandwidth Multi-strike capable 10 year warranty ISO 9001 & 14001 Certified Shanghai Office Room A, Floor 14, East. Ocean Center, No. 618 Yan an Road East, Shanghai 200001, PR China +86.21.33184650. f +86.21.53854506 Headquarters P.O. Box 9000. 2225 Park Place Minden, Nevada 89423 +775.782.2511. f +775.782.4476 info@polyphaser.com www.polyphaser.com India Office A division of John Crane Sealing Systems India Pvt. Ltd. 11, 1st Phase, Peenya Industrial Area Bangalore 560 058, India +91 (80) 2839 2200. f +91 (80) 2839 8205/06 BE PREPARED, BE PROTECTED.