X4 Process Controller

Similar documents
BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Cable guide. for. High Performance Controllers and TeleControllers. Cable types and wiring guidelines

Set for simple I/O communication via PROFIBUS-DP in IP20 TI-BL20-DPV1-S-8

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

LAUREL ELECTRONICS, INC.

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

ODW-621. RS-232 Point-to-point applications

VIPA Accessories. ProfiHub B BE00 Manual

Fibre Optic Modem ODW-611

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

DCP100 Digital Control Programmer Specifications

EVENT INPUT/OUTPUT MODULE [PUME]

IPS 2400 SMAVIA Appliance for up to 24 IP Channels, 8 3.5" HDD, 3 HU

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

150, MULTI CVIL II Power Train approved. More Than Productivity

4-in-1 Motor Controller CAN

AF-300 E11 Adjustable Frequency Drive

CEDES. Functional description CEDES 7-Segment Double Digit Indicator (CAN) Functional description 7-Segment Double Digit Indicator (CAN)

Product Specifications

BL67 electronic module 2 analog inputs for Pt and Ni sensors BL67-2AI-PT

ERbic Bus Interface Connector System. Catalog E /06 Edition 4

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Absolute Encoders Multiturn

LASER. Laser-Position-Transducer. LLD Series. Key-Features:

ROTARY ENCODER SELECTION. A Step by Step Guide

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Absolute encoders multiturn

Operating instructions Electronic preset counter Type series 717

SY-HDBT-100 Extender Set

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

Specifications MAV Series Matrix Switchers

BL67 electronic module 4 analog inputs for thermoelements BL67-4AI-TC

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

TECHNICAL SPECIFICATION ERC 1340

LASER. Laser-Position-Transducer. LLD-150 Series. Key-Features:

AD16-16U(PCI)EV. Features. High-Speed & Resolution Analog Input Board for PCI AD16-16U(PCI)EV 1. Ver.1.02

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

SOFTLINK 300. Modules Specifications. Reference Manual

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

L-BAND MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

RLS Series RLS-GD-20/20 -UV. Design. RLS-GD Series Gloss Detection Sensors. Accessories: (cf. page 9) Product name:

Fieldbus Components Section K

EasyConnect 2.0. The revolution for your conference room - Now as 4K Multiformat Transceiver

Operating temperatures from 20 C ( 4 F) up to 50 C (122 F). Up to 70 C (158 F) with current derating and optional control module fan kit.

More Precision. scancontrol // 2D/3D laser scanner (laser profile sensors)

Re:connect M 203. RS232 Interface Revox. Dominating Entertainment. Revox of Switzerland. E 2.03

Technical data. General specifications. Indicators/operating means

DVI KVM Extender DVIVision 7.6

Fibre Optic Modem ODW-622

The Admiral Type 4 family of safety light curtains is the ideal solution for the protection of the majority of high-risk industrial applications.

DATA SHEET Panorama Rudder Indicator, TRI-2

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

SCALE & WEIGHT DISPLAYS

KELLER Interface Converter

QUICK START GUIDE FLEXSLICE MODULES

PRINCIPLES AND APPLICATIONS

Process transmitter RMA422

Rexroth IndraDrive Fc Compact, high-performance standard frequency converters

SY-HDBT-SLIM-100S Extender Set

Digital 4 Q - Servo amplifier for brushless DC Servo motors (Trapeze)

Rack mounted telephone- and leased line modem for industrial applications

Assembly. Front view. LEDs. Parametrization interface. Power Bus

TABLE OF CONTENTS. Instructions:

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

POSIWIRE. WS61 with internal magnetic encoder Position Sensor. Cable Extension Position Sensors. Datasheet

Operating Instructions (ed. 5.97) Electronic Preset Counter Type Series 904

Instruction manual Universal Fieldbus-Gateway UNIGATE IC - DeviceNet

HDMI over CAT5 HDBaseT Extender - RS232 - IR - Ultra HD 4K ft (100m)

F M2SDI 2 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485 & Aux. User Manual

Advantys STB Standard Profibus DP Network Interface Module Applications Guide. 890USE17300 Version 2.0

AI-1204Z-PCI. Features. 10MSPS, 12-bit Analog Input Board for PCI AI-1204Z-PCI 1. Ver.1.04

SPECTRO Series SPECTRO-3-30-UV. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9-10)

Connectivity for Ethernet

Connecting cables for fieldbuses

P P S - M W S C A N 1 H

FACTORY AUTOMATION AS-INTERFACE MAINTENANCE AND TROUBLESHOOTING GUIDE

WEIGHING INDICATOR SERIE IPE 50

LD OEM/LD PDS/LD PeCo

DMX 512 Language Date: Venerdì, febbraio 12:15:08 CET Topic: Educational Lighting Site

SignalTap Plus System Analyzer

5024 WEIGHING TERMINAL

SPECTRO Series SPECTRO-3-20-COF. Design. SPECTRO-3 Series True Color Sensors. Product name: Accessories: (p. 9)

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Operating Instructions

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Instruction Manual. Series 3000 Model R-165A. Audio/Video IF/RF Relay Panel. CATV Switching and Control

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

User Manual KUNBUS-PRS

IMPAC Infrared Thermometers

DVI KVM Extender DVIVision 7.4

SAT IF distribution system

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

Z-D-IN. RS485 Modbus Module 5 Digital Inputs

48x24. Options ORDER NUMBER OF TYPE PFL B

Transcription:

available KW 22-2004 Description New Slot 12NC PR5510/04 Serial I/O RS232 und RS485/422 1/2 9405 355 10041 PR5510/06 PR5510/07 PR5510/08 PR5510/09 PR5510/12 PR5510/14 PR1721/31 PR1721/32 PR1721/34 PR1721/35 1 Analogoutput 0/4-20mA 4 analog In- / 1 analog Output BCD open emitter BCD open collector 6 digital In-/ 12 digital Outputs Ethernet incl. ModBus TCP Profibus DP Slave Interbus S Slave DeviceNet Slave CC-Link -planned- 3 1/2 1/2 1/2 1/2 4 4 4 4 4 9405 355 10061 9405 355 10041 9405 355 10081 9405 355 10091 9405 355 10121 9405 355 10141 9405 317 21311 9405 317 21321 9405 317 21341 9405 317 21351 PR8901/81 Licence internal Alibi-memory 9405 389 01811

PR5510/04 Connection mode: No. of channels: Type: Transfer rate: Signals RS 232C (V24) Signals RS 422/485: Potential isolation: Cable length: Cable type: Accessories: Dimensions: Weight: 2x DSUB 9-pole socket (female) 1x RS 232, 1x RS 422/485 RS 232 full duplex RS 422/485 full duplex (4-wire) RS 485 half duplex (2 -wire) 300 to 9600 to 19k2 Bit/sec Output:TD, RTS, DTR Input: RD, CTS, DCD, RI TxA, RxA, TxB, RxB RS 232 no, RS 422 / 485 yes max. 15m with RS 232 max. 1000 m with RS 422 / 485 Pairwisely twisted, screened (i.e. LifYCY 3x2x0,20), 1 conductor pair for (GND). 2x connector counterpart DSUB9 (male) incl. screening hoods (LxBxH): 86 x 52 x 15 mm 33 g

PR5510/06 Connection mode: No of outputs: Output: Range: Resolution: Linearity error: Temperature effect: Zero error: FSD error: Load: Cable length: Accessories: 3pol. Combicon Connector 1 current output 20mA (voltage-output-10v only with external 500 Ohm resistor) Gross-, Net weight or applikation dependent. 0/4...20mA, configurable via SETUP 16 Bit binary, 20.000 internal divisions for e.g. 0-20mA @0-20mA: 0,04% @4-20mA: 0,02% < 100ppm/K 0,05% < 0,1% 0...500 Ohm max. short circuit proof, potential isolated max. 150m (current output) 3pol. Combicon-plug in/screw

PR5510/08 Connection mode: No of outputs: No of Inputs: Output stage: External supply: Voltage drop: Input (enable): Load: Cable length: Accessories: 1x DSUB 26-pole socket (female) 6 digits BCD or 24 Bit binary (with I/O config.) 1 Bit (DATA IN) Common Collector at +Uext. Open Emitter (Load -> GND) +5V...+24V, max.32v approx.1,7v 5V/24V adjustable via S101 @5V high>3,1v, low<1,5v @24Vhigh>16V, low<10v Protected against wrong polarity max. 50mA, no potential isolation max. 50m (screened) 1x connector counterpart DSUB26 (male) incl. Screening hoods optinal with 3m cabel (open ends)

PR5510/09 Connection mode: No of outputs: No of Inputs: Output stage: External supply: Voltage drop: Input (enable): Load: Cable length: Accessories: 1x DSUB 26-pole socket (female) 6 digits BCD or 24 Bit binary (with I/O config.) 1 Bit (DATA IN) Common Emitter at GND Open Collector (Load -> +Uext) +5V...+24V, max.32v approx.1,7v 5V/24V adjustable via S101 @5V high>3,1v, low<1,5v @24Vhigh>16V, low<10v Protected against wrong polarity max. 50mA, no potential isolation max. 50m (screened) 1x connector counterpart DSUB26 (male) incl. Screening hoods optinal with 3m cabel (open ends)

PR5510/12 Connection mode: Number In-/ Outputs: Input signal: Input current: Output: Potential isolation Cable length: Accessories: Optional: 1x DSUB 37-pole socket (female) 6 12 Low 0...5V bzw. offen high 10...31V passiv <7mA@24V <3mA@12V protected against wrong polarity max. 32V, 25mA voltage drop @25mA: 3V protected against wrong polarity, passiv yes, via opto-coupler max. 50m (screened) 1x connector counterpart DSUB37 (male) incl. screening hoods PR 1623/10 4m connection cable PR 1623/20 Relais-terminal unit PR 1623/30 Terminal unit

PR1623/20 PR1623/30 PR1623/10

NEW Connection mode: internal Connection mode: external Output: Input: 34-pole socket (male) with flat cable for Slot-1 or Slot-2 2-row, 15-pole SUBD socket (female) 1 current output, voltage output with external resistor (spec. Refer to PR 5510/06). activ = supply by internal power supply 4 channels current resp. voltage input passiv = * external supply necessary! PR5510/07 Input range: Input resolution: Input Accuracy: Linearity error: Temperature effect: Potential isolation: Accessories: 0... 20 ma, input resistance 250 Ohm 0... 10 V, input resistance 100 kohm 0... 5 V, input resistance >10 MOhm 3.000 internal digits proportionate e.g. 0-20 ma / 0... 10 V (Reserve +- 15%, i.e. 1,5V... +11,5V ) 0,2% <0,003% <50ppm/K Output yes, Input no 1 connector counterpart SubD 15-pole PR5510/07 can not be used when SLOT-4 contains a fieldbus option. Reason: Overload of power supply

NEW - Fieldbusoptions

Fieldbusoptions Functions Read window Write window Fieldbus Module 1 Firmware functions Read: -Gross, Net, Tare etc. Write: -Tare, Untare etc. Module 2 application related functions e.g. BATCH, IBC please refer to manual Module 3 Functions, defined by user programming

NEW Connection mode: int. Connection mode: ext. Transfer rate: Kind of connection: Protocol: Transport: Cable: Cable impedancy: Certificates: Potential isolation: Cable length to hub: 34-pole socket (male) with flat cabel for Slot-4 RJ45 socket at back panel 10Mbit/sec (10BaseT, Ethernet) and 100Mbit/sec (100BaseTx, Fast Ethernet) Auto detection (10/100, HalfD/FullD) Network EW_COMM, Modbus/TCP TCP/IP or UDP/IP Pairwisely twisted, screened e.g. patchcable CAT5 accord. to use (straight/crossover) 150 Ohm Compatibel according to: Modbus Organisation for ModBus-TCP standard Industrial proved CE, UL, cul yes max. 30 m PR 5510/14 Ethernet PR5510/14 can not be used if already two active analog outputs are used. Reason: Overload of power supply The option will be supported from firmware release R3.12 onwards.

NEW Connection mode: int. Connection mode: ext. Transfer rate: Kind of connection: Protocol: Transport: Cable: Cable impedance: Bus connection: Certificates: Potential isolation: 34-pole socket (male) with flat cabel for Slot-4 9-pole SubD socket (female) 9.6 kbit/s up to 12 Mbit/s auto baudrate detection Profibus-Network, open / close of connections without interrupting other stations PROFIBUS-DP-V0 SLAVE acc. EN 50 170 (DIN 19245) Mono- or Multi-Master systems are supported. Master and Slave Devices, max. 126 nodes possible. Per module 244Byte OUT and 244Byte IN, in Total 416, typical 32Byte Watch-Dog Timer EIA RS 485, Profibus DIN 19245 Part 1 Pairwisely twisted, screened 150 Ohm per DIL, activated external Profibus Test-Center Comdec in Germany and PNO (Profibus User Organisation) Industrial proved CE, UL und cul Optocoupler in Line-A and B (RS 485) PR 1721/31 Cable length: max. distance 200m at 1.5 Mbit/s expandable by additional Repeater The option will be supported from firmware release R3.12 onwards.

NEW Connection mode: int. Connection mode: ext. Transfer rate: Kind of connection: Protocol: Transport: Cable: Cable impedance: Bus connection: Certificates: 34-pole socket (male) with flat cabel for Slot-4 IBS standard 9-pole SubD female OUT and male IN 500kbit/s or 2 Mbit/s, adjustable point_zu_point, active coupled ring INTERBUS-S SLAVE-international (IEC 61158 part 3 to 6), national (DIN 19258), European Standard (EN 50254) Cyclic data transfer with max. 10 words I/O. PCP 2.0 Parameterchannel with max 4 words. PMS 2.0 service: Initiate, Abort, Reject, Status, Identify Get-OD (long), Read, Write RS 422 Interbus special-cable colour: May green 3x2 Pairwisely twisted, screened 150 Ohm Not applicable, for active ring By Interbus-Club: compatibility to Interbus Standard Industrial proved CE, UL und cul PR1721/32 Potential isolation: Cable length: Optocoupler in Line-A and B (RS 422) The option will be supported from firmware release R3.12 onwards.

NEW Connection mode: int. Connection mode: ext. Transfer rate: Kind of connection: Protocol: Transport: Cable: Cable impedance: Bus connection: Certificates / Conformity: Potential isolation: Cable length: 34-pole socket (male) with flat cabel for Slot-4 5-pole screw terminal block (withdrawable) at back panel 125, 250 and 500kbit/s as Setup-Param bidirectional Parallel-Bus DeviceNet SLAVE Max 512 bytes cyclic Input and Output Data. Max 2048 bytes a cyclic Input and Output Data. EIA RS 485 2x2 Pairwisely twisted, screened 150 Ohm 120 Ohm at both ends necessary (CAN_H <-> CAN_L) Compatible to DeviceNet Spec. Vol 1: 2.0, Vol 2: 2.0 ODVA Certificate acc. Conformity software Version A-12 Industrial proved CE, UL und cul yes, completely galvanic isolated PR1721/34 The option will be supported from firmware release R3.12 onwards.