Digital 3000 AS. Instructions for use 110V and 230V, Version POWER UNIVERSALITY. For DIGITAL PHOTOGRAPHY. English

Similar documents
D-LITE RX FAMILY WHY D-LITE RX ONE?

Operating Instructions BRONCOLOR SIROS

monolight Q-400 INSTRUCTIONS INSTRUCTIONS

Studio 300/400 Monolight with Built-in R2 2.4GHz Radio Remote System

ENGLISH THE LIGHT AHEAD ELINCHROM FLASH SYSTEM ELINCHROM THE LIGHT AHEAD 2014 ENGLISH

Elinchrom Wireless System

p Michael Clark p.36, p Anoush Abrar p Victor Gonzales p Tom Bol

Please read this manual before operating XB PRIME, and keep it for future reference. Referez-vous au mode d emploi avant d utilizer la XB PRIME.

VC-500WL3KN Digital Monolight INSTRUCTIONS

VISATEC Putting people in a professional light

Hip Hop Activity Box. Instruction Manual. Hip Hop Activity Box 22875, October 2018 Copyright ROMPA Ltd

Model DT-311J. And DT-311J-230V(AC) DIGITAL STROBOSCOPE INSTRUCTION MANUAL

PREAMPLIFIER INTRODUCTION INSTRUCTIONS FOR USE. Thank you for purchasing the Musical Fidelity A3 CR remote control preamplifier.

414 P 1. DESCRIPTION AND TECHNICAL SPECIFICATIONS 2. LAY-OUT OF STANDARD SYSTEM INSTALLATION DIMENSIONS. Fig. 1. Fig. A

MonoBright LED DAYLIGHT 1200

Figure 1: Device components

.Power Distribution Center. PD-1. Instruction Manual

MonoBright LED DAYLIGHT 750

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

DLP200M 2 Relay Module for Heating and Cooling Plants

ORDER CODE: EQLED65 USER MANUAL

CM-S23349SV. Vari-Focal IR Bullet Camera

Rovelight RT 600AC TTL / 800AC TTL. AC TTL Monolight Bowens Mount

JS007WQK HEAVY DUTY WIRELESS REVERSING KIT 7 LCD DIGITAL QUAD RECORDING MONITOR with WATERPROOF CCD CAMERA

CM-S38901SV TVL IR Long Range camera

SmartCrystal Cinema Neo

STX Stairs lighting controller.

Winmate Communication INC.

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

Outdoor IR Audio Camera

Sound to Sight Showtime

AN2 Series. 900tvl. CMOS Technology High Resolution Sensor. elinetechnology.com P/N 01.BSM V1.0

DLP600M 6+1 Relay Module for Heating and Cooling Plants

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

HDMI 5x1 Switch B-240-HDSWTCH-5X1 INSTALLATION MANUAL

VITEK VTM-TLM191 VTM-TLM240

VK-P10SE WARRANTY REGISTRATION FORM

UK. Multi Channel Programmable Filter-Equalizer. User Manual FEATURES. - Designed for both digital and analogue channels,

Stereo Cassette Deck

Hex-color RGBAW+UV LED strip light

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

Wired Troubleshooting Manual

SMART CINEMAHORIZONTAL. User Guide VPSP Projector side. model. Notice SmartCrystal Cinema MUV V1R0

6X3W RGB LEDS PROJECTOR FOR PROFESSIONAL TRUSSES USER GUIDE / Version 1

Aspect 2 Circuit Digital Scene Control

CP1 OAD. Owner s Manual. Stereo Control Preamplifier. Ultrafidelity

LED Backlight for Technics amplifiers

Q-TV2. User Manual. for Screens

LIGHT COPILOT II. elationlighting.com Internet:

Stage Right Party 10-Watt Mini Beam Moving Head LED Light

SquareLED - Aura Bar & Matrix Beam Light 100

DMX LED light effect with 4 lenses

VT VGA TFT NEMA 4/12 Flat Panel Monitor. User s Guide

Phono Amplifier brinkmann «EDISON» Manual.

INSTRUCTIONAL MANUAL FOR LCD ZOOM MICROSCOPE

SmartCrystal Cinema Neo

SATRI AMPLIFIER AMP-51R. Owner s Manual

KNX Dimmer RGBW - User Manual

Tube Rotator. User Guide. Version 1.2

Led Dynamic DMX Tri Curtain Manual

K Service Source. Apple High-Res Monochrome Monitor

Indoor/Outdoor Security System with Quad Monitor User s Manual

CHECK LINE. Model LS-36-LED. Stationary Stroboscope. Operating Manual BY ELECTROMATIC

Warning Statement. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to

Quick Reference Guide

Thank you for purchasing a qualiton APR204 preamplifier!

Dissolve Control Programming : Projector/Dissolve Control Hook-Up

Electric Wall/Ceiling Projection Screen Saker Plus Series User s Guide

INTEGRATED AMPLIFIER INSTRUCTIONS FOR USE

Enterview 2 / Enterview 2V 4 WIRE VIDEO DOORPHONE SYSTEM

Stereo Cassette Deck

User Manual Color video door phone

SceneStyle2 User Guide

Rebis Audio Ltd. RA226 Digital Sampler User Guide

Owner s Manual PRE1. v1.2. Triode Class A Line Preamplifier

TBC & Matrix Switcher TBC-5000 Instruction Manual

General. zoom ring. focus ring. Size of liquid. Color. foot adjust levers. Projection. Computer In. Mouse/Com. Power

Product Manual. Designed and Manufactured in the UK by Optikinetics

AVS50 USER GUIDE. 2.4GHz Audio/Video Sender System - AVS50

FD Trinitron Colour Television

T L Audio. User Manual C1 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

1. Before you Begin Introduction Setup Operation Technical Information Technical Specifications...

Stage Wash 7x 10W LED Moving Head (RGBW)

MANUAL ENGLISH Core Club Ordercode: D2314

DIGITAL STROBOSCOPE OPERATION MANUAL. Model : DT-2239A

Spectra Batten (Order code: LEDJ95)

INSTRUCTION AND MAINTENANCE VIDEO MOTORE PROJECTION SCREEN

LED Thunder S-150 Code 1097

sequenza 1000/1250 al manuale di istruzioni instruction manual 1^ edizione, ottobre st edition october 1996

Thank you for purchasing a qualiton PHONO preamplifier!

Instruction Manual. from software version 1.0 (instruction version 1.3) Internet:

Ios english manual:ios english manual.qxd 07/08/ :35 Page 1

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

ACUBRITE 23 SS. Manual. Stainless Steel Chassis 23" LCD Display. Content

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

1440/2880 HP RGB+WW+CW

HDCVI Camera User s Manual

1. Before You Begin... 3

Transcription:

elinca sa switzerland www.elinchrom.com Digital 3000 AS For DIGITAL PHOTOGRAPHY POWER UNIVERSALITY TOTAL ASYMMETRY Instructions for use 110V and 230V, Version English

Table of contents page Safety notice 3 Control panel 4 Before you start 5 Technical data 6 Mains inlet and fuses 7 Open flash button 8 Power variator 9 Troubleshooting 9 Photo-cell 10 Synchronization 10 Audible signal 10 Modelling lamp selector 11 IRS remote control 11 Lampheads 12-13-14 Other poducts " accessories overview" 15 P.S: Technical data subject to change. The listed values are guide values which may vary due to tolerances in components used. 2

The Elinchrom Digital generator is manufactured by Elinca S.A. CH -1020 Renens/Switzerland Dear Photographer, Thank you for buying your «Digital 3000 AS» flash generator. All Elinchrom products are manufactured using the most advanced technology. Carefully selected component are used to ensure the highest quality and the equipment is submitted to many controls both during and after manufacture. We trust that it will give you many years of reliable service. All flash units are manufactured for the studio and location use of professional photographers. Only by observance of the information given, can you secure your warranty, prevent possible damage and increase the life of this equipment. SAFETY NOTICE According to safety regulations, we draw your attention to the fact that these electronic flash units are not designed for use outdoors, in damp or dusty conditions and should not be used after being exposed to sudden temperature changes causing condensation. They must always be connected to an earthed (grounded) mains supply. On no account should any objet be inserted into the ventilation holes. The units may retain an internal charge for a considerable time even though disconnected from the power supply.! FLASH SYSTEMS STORE ELECTRICAL ENERGY IN CAPACITORS BY APPLYING HIGH VOLTAGE. FOR YOUR SAFETY, NEVER OPEN YOUR FLASHES. ONLY AN AUTHORISED SERVICE ENGINEER SHOULD OPEN OR ATTEMPT TO REPAIR THE UNITS. FOR REPAIRS, BRING THEM TO YOUR ELINCHROM AGENT. 3

21 1 5 7 9 10 11 12 17 20 18 2 3 19 4 CONTROL PANEL 1.Mains inlet power socket 2.Mains fuse (16 AT, slow blow) 3.Charge speed selectors - slow charge - normal charge - fast charge 4.Mains switch 5.Photocell and IR-Receiver 6.Photocell on/off 7.Sync.-socket with security lock 8. Open flash with charge indicator 9. IR-Remote On/off 6 8 13 14 15 16 22 10.LED indication of total power 11.Generator selector IR (1-8 packs) 12.Multi-purpose accoustic signal 13. Half/full power for modelling lamps 14.Modelling lamps on/off 15.Modelling lamp dimmer/charge signal 16.Proportional modelling light 17.Power output indication in Ws/joules 18.Lamphead sockets 19.Security catches 20. Lamphead power modulators 21. Socket accessories 22. Lamphead on/off 4 FOR YOUR SAFETY, NEVER OPEN YOUR POWER PACKS OR YOUR LAMPHEADS. FOR REPAIRS, BRING THEM TO YOUR ELINCHROM AGENT.

Operating instructions 1) Mains connection The unit is manufactured to run on 200-240 V, 50/60 Hz. Before connecting them for the first time, make sure that your mains supply and the rating set on the equipment (electrical specification plate) are compatible. 2) Check that the mains switch (4) is OFF 3) Insert mains cable to the MAINS INLET (1) and connect to a FULLY EARTHED OUTLET 4) Using the mains switch (4) and switch the unit ON (switch illuminated) 5) Connect lampheads ensuring that lampheads switches ( 22) are OFF, i.e. display NOT illuminated 6) Select charging rate (3) "normal" 7) Select modelling lamp setting (16) 8) Connect the synchro cord on the socket ( 7) 9) Check that photocell ( 6) is OFF (not illuminated) 10) Switch on the lampheads : the touch ( 22) switches individually the flash circuits and modelling lamps 11) Select the power with the touch (+ or -). 12) The green open flash button ( 8) will light up, indicating that the unit is ready for operation. According to the safety regulation: we draw your attention to the fact that this equipment should be used only in a dry environment; it must be protected from dripping water and from extremely dusty conditions. The unit must ALWAYS be plugged into an EARTHED electrical socket. 5

TECHNICAL DATA : This power pack Digital 3000 AS ( 3000Ws) offers three asymmetrical power head outlets. The power levels are indicated in Ws by bright LED display. These displays may be individually varied in 1/10th f-stop to any one of 57 settings on each lamphead (with three lampheads). The variation is continuous on 6.6 f-stops, (diaphram variation 22.7 to 180.3). POWER REQUIREMENTS : For version 110/120 V : Mains voltage: 110-140 Vac 50/60 Hz For version 220/230 V : Mains voltage: 210-240 Vac/50 Hz Dimensions: 49 x 14 x 32 cms Weight: 11.65 kg CHARGE SPEED on mains 230 V- 50 Hz 1.8-10 s 0.8-4.5 s 0.7-3.5 s on mains 115 V- 60 Hz 2-11s 0.9-5.5s 0.8-4.5 s RELATION OF POWER RANGE BETWEEN THE OUTLETS Guide aperture is based on the "Digital S" head and the standard reflector, distance 1 m/3.3 ft and film ISO 100/21 DIN. Display Ws f-stop Power 9 3000 (180.3) 1/1 8 1500 (128.3) 1/2 7 750 (90.3) 1/4 6 375 (64.3) 1/8 5 188 (45.3) 1/16 5** 95 (32.3) 1/32 with 2 lampheads 5*** 62 (22.7) 1/48 with 3 lampheads 6 *with 2 or 3 lampheads

1. MAINS SUPPLY While the MAINS SWITCH (4) is switched off firmly push in the plug of the original ELINCHROM mains cord into the socket (1). 2. FUSE Standard type 5 x 20 mm, 16 AT (tempered). Before exchanging a blown fuse, switch off the unit and remove mains cable. Depress and turn the fuse holder anti-clockwise 1/8th and remove it. If the new fuse blows immediately upon reconnection return the pack to an ELINCHROM service centre for a check-up. (N.B. Check correct value of the fuse : 16 AT). N.B. SECURITY FUSE This unit is protected by an internal security device. Should the unit not work properly, for example because of a defective power component, the internal security fuse of 16AF (fast) would instantly get destroyed, which avoids any recharging. From then on, the power pack requires a check up by a technical Elinchrom service. 3. MAINS SWITCH The button lights up when the pack is switched on. Switch off before removing the mains cord. Note : the absence of charge, despite the switch being illuminated, indicates a fault. 4. CHARGE SPEED SELECTOR Select the required charging speed with the selector (3). FAST : is the standard position recycling, for use in the professional studio. (Position for the digital "one shot") 230 V = 16 A 115 V = 25 A NORMAL : standard recycling recommended for use in the studio with line 16 A. (Position for the digital "multi-shot") 230 V = 12 A 115 V = 20 A charge SLOW : position is recommended when the mains capacity is too limited for the use with the standard charge. (for the digital "multi-shot") 230 V = 8 A 115 V = 15 A 7

N.B. For even less load on the power supply line use lamps automatically extinguish when the generator when the charge cycle ends. and jointly. The modelling is charging but illuminate 5. INITIAL CHARGE If the generator has been recently used and the capacitors do not require «reforming», the generator will charge at the speed setting indicated, i.e. fast, normal or slow. If the generator has been recently used, to reform the capacitors it will charge slowly. If the desired speed setting is fast or normal, the appropriate indicator will glow, but the slow charge indicator will blink to show that for this one charge sequence it has automatically taken control. 6. OPEN FLASH «TEST» Having pressed this button release a flash, the green led «READY» light will appear again once the unit is recharged. If the green light does not appear the charge system could by defective. Please contact and send to an authorized Elinchrom service. N.B. Situation 2, as above is the only time when the open flash will function while the indicator blinks. At other times, the generator is not ready (still charging or fed with incorrect requests) and will therefore not function. NOTE : The "Digital" unit have an integrated discharge system, protected by a thermic switch. In order to restrict the heating of the unit, we suggest to release a flash with the green button (8) "READY" after each strong reduction of power (more than 2f-stop). This allows to release the excess of energy in the flash tube. You will gain time and extend the life span of your power packs. 8 7. AUDIBLE RECHARGE SIGNAL When the indicator of the touch (12) is illuminated and will sound whenever a command has been accepted by the generator (useful when using the IR handset). There is an audible signal after each recharge. It indicates that the generator is ready. Continuous signalling indicates a false request or malfunction. Please check generator and lamphead connections.

8. TOTAL POWER This display indicates the total power released through the lampheads. The variation is a single steps or if the touch is held it will run continuously. The first number indicates charges by full f-stop, the second number by 1/10 f-stop. When the total power is increased each individual lamphead increases proportionately. The ratio never changes and the power in any one lamphead is limited only by the total power in the generator. When this power is reduced your chosen asymmetry remains, but is always variable at your discretion. 9. INDIVIDUAL POWER OUTPUT This facility gives subtlety and independence of power control unobtainable in any other way. The Ws/Joules readout enables you at a glance to evaluate the relative power of each lamphead which you may change at any time. It varies progressively with the principal power read-out. The limite are only the maximum power of the pack and the minimum power through one outlet - all steps being in 1/10th f-stops. 10. POWER INDICATOR «BLINKS» If the power display blinks, the connecting of the lamphead may have given a total Ws/Joules display of all lampheads of more power than the generator can store. - Press the touch to reduce the totals of the power displayed to the correct figure. Alternatively, switch off a lamphead. Conversely, if at minimum power, a lamphead is disconnected, the power indicator will blink because there is now more power in the generator than the read-outs in Ws/Joules indicate. Adjust by pressing. + N.B. The display will also blink if lamphead power supply is greater than the flashtube can accept, e.g. an S1500N head fitted to a generator outlet displaying 3000 Ws will not release and the display indicates that there is an incorrect request. Adding or removing a lamphead does not change the power programmed into other lampheads. It increases or decreases the total power stored. 9

11. SWITCHABLE PHOTOCELL (SLAVE) When switched ON indicator illuminated, the pack can be remotely triggered by another flash unit in your studio. In difficult situations e.g. daylight, blinding or obstacles, the additional cell (code 11080) with 5 m cord (extensions available) solves most problems. Alternatively use the FRC-SYNCRON (code 19316) cordless remote flash release. 12. SYNCHRONISATION SOCKET The Amphenol secure locking system with standard 5 m cable is retained. Longer cables may be used. N.B. Do not link ELINCHROM units by cable to other manufacturers sync outlets. ELINCHROM uses low voltage (12 V) for security reasons and other systems with higher voltages may cause damage. 12. ACCESSORY SOCKET Alternatively the ELINCHROM SYNCRON (code 19316), cordless radio may be used with the FRC-1 transmitter (code 19306) which releases the flash instantaneously - faster but slightly slower than by sync cable. Therefore, use 1/60th for focal plane shutters and 1/125th for in lens shutters. FRC1 : 19306 Syncron Set : 19310 Alternatively mount an infrared flash trigger on the camera (e. g. Prolinca IR transmitter : code 40203) 10

14. MODELLING LAMP CONTROLS The modelling lamp will only function when the lamphead is switched on (note : there is an overheating control switch ON/OFF in the lamphead). - Simple ON/OFF with ON setting indicated. Also incorporated is a slow start system to prolong lamp life - Half power lamp setting further extends lamp life - Adjusts the lamp to vary with the flash power. - DIM/BRIGHT CHARGE INDICATOR This setting underpowers the modelling lamps during charging. At full charge they <<indicate>> by coming to full brightness. - Used together, the modelling lamp extinguishes during charge. 15. USE OF IRS To activate the Infra Red System press the IRS Control Allocate the unit a channel number. First press the channel selector This will display a channel number 0-8. keept this button pressed and when you have reached your chosen number release. This sets the unit to the channel number displayed. You can either select a different number for every head. If you wish to control two or more heads identically then give them the same channel number, they will then respond to the same signal. If any other number is selected on the IR-handset, the IRS indicator will blink to advise that the generator is not accepting the commands. To use the IR-remote : first select a numbered channel on the handset. This will activate the unit(s) allocated to that channel. No other units will respond. To measure the f-stop, this unit can be flashed alone OR, to take an overall reading, ALL units will respond if «O» is pressed on the handset. IR Remote control code : 19319 11

USE OF IRS The indicator on the IRS will «blink» on the generator when its channel has not been selected. However, selecting its channel «O» will re-activate the units response system. The units function like and are therefore totally compatible with Micro AS power packs and 750 Micro. 13. LAMPHEADS Important : When plugging in a lamphead connector, first push in the front part, then firmly press in the whole plug, the rear part being secured by the locking spring. 1 2 DO NOT PLUG IN OR UNPLUG LAMPCORDS WHILE THE DISPLAYS ARE ON i.e. ILLUMINATED. 14. LAMPHEADS ON/OFF Connect the lamphead. The ventilator fan functions even in OFF mode. After a studio session, leaving the generator switched on, but the lampheads OFF extends lamp and tube life. If the power display does not illuminate i.e. ON/OFF appears not to function, the lamphead is incorrectly fitted, the connector is damaged or it is an old lamphead unadapted. 3 0 0 0 + - 15. FUSES FOR LAMPHEADS Use only FAST BLOW FUSES, type 5 x 20 mm corresponding to the label on each lamphead. Different modelling lamps require corresponding fuses. Slow blow fuses will not protect the modelling lamp. The fast blow fuse will protect the triac of the modelling lamp circuit, the lamp and therefore the flash tube. FUSE W 110V 240V 200 2AF 2AF 300 5AF 2,5AF 650 10AF 5AF ATTENTION use only recommanded fuse Modelling switch Fuse 12

16. PROTECTIVE PIREX DOME For use with standard halogen lamp GX 6.35 socket. Transparent, matt or yellow (400 K colour correction), can be fitted to all lampheads, except R heads (rectangular heads) for which clear or matt security filters are available. Easy attachment of the protective dome: - Disconnect the lamphead from the pack - Loosen the 3 screws of the lamphead reflector - Fit the clips underneath the screw heads and tighten the screws - Put the dome in place and hook the springs into the airvent holes. The security filters for the Digital RE - R 3000 - Mini R, can be put on the lateral accessory holders, clear (code 26253) or matt (code 26254). 17. LAMPHEAD TYPES 1. With standard flash duration : Types S and R (Digital S - Digital SE - Digital RE) security filters 2. With action stopping (short flash duration) : Type A (X 6000N and Twin X4 with one power pack) For fashion photography, sport applications and just as useful in the studio for photographing fast moving subjects. NOTE : Due to their relatively high power and short duration, it is probable that the flash tube may be shorter than our standard lampheads. The X-heads (X6000N - Twin X4 - X8000) has two special flash tubes that focus and maximise the light ouput. They can be used for standard or action : a) with each cable in a separate power pack, it gives standard flash duration. b) with both cables in the same power pack, it gives short flash duration. FOR YOUR SAFETY, USE ONLY ELINCHROM LAMPHEADS ON YOUR GENERATORS 13

18. LAMPHEAD COMPATIBILITY Below is a table listing lampheads made since 1980 which are adaptable and indicates the equivalent in the current series. MAXIMUM Compatible with : Digital 1500/3000 AS and MICRO AS ADAPTABLE POWER From 1992 1988 1986 1980 1500/2400 WS S1500 N S 2000 S2 S Mini 1500 A2000 A2 2400 Ws/2000* Mini A R 2000 R2 2400 Ws/2000* Mini R 2400 Ws/2000* Mini S 2400 Ws/2000* Chic S2 2400 Ws/2000* Digital SEE 2400 Ws/2000* Digital RE 3000 Ws** Digital S (4000 W) Digital SE R3000 S3000N S3000 A3000N Spot Lite 3000 Box Lite 3000 Boxlite 3000N Ringflash RF 3000 A3000 4000 Ws Digital S S4000 T4 T A4 A4 A Box Lite 4000 Box Lite 4000 4800 Ws (2 x 2400) Twin X4 R4000 R4 6000 Ws (2 x 3000) X6000N 8000 Ws (2 x 4000) X8000 X8 X 14 * 2000 Ws with MICRO series ** 3000 Ws with MICRO series

Reflectors code Wide angle ø 16 cm /90 26143 Compact ø 18 cm /60 26144 Standard ø 21 cm /50 26141 Mini soft 44 silver 26166 Mini soft 44 white 26168 Snoot 26425 Grids code Grid set for 18 cm 26135 Grid set for 21 cm 26025 Lightshaper carriers code Carrier for 21 cm reflectors 26034 Bandoor set for 21 cm 26037 Filters code Set of 10 color/mixed for 21 cm x 21 cm 26243 Polarizing filter 21 cm 26244 Lightbanks ROTALUX code Square 70 x70 cm 26178 Square 100 x100 cm 26179 Strip 95 x 35 cm 26180 Rectangular 130 x 50 cm 26181 Octagonal 100 cm 26183 Octagonal 135 cm 26184 Varistar Umbrellas Varistar Umbrella 85 cm 26383 Varistar Umbrella 105 cm 26384 Umbrellas code White diam. 105 cm 26375 Silver diam. 105 cm 26361 Translucent diam. 105 cm 26374 Accessories overview Spots code Zoom 12-24 26471 Mini spot 26420 fresnel spot 26450 Tripods code Tripod «Deluxe» 85-200 cm 30128B Tripod «Master» 105-385 cm 30149B Bags code Carrying bag for 3 stands + umbrellas 105 cm 33222 Bag for medium size Rotalux 33223 Bag for large size Rotalux 33224 Trigger accessories code and flashmeter IR flash remote 40203 Radio set FRC1 19305 Additional cell with grip 11080 Miscellaneous cords code Synchro cable 5 m lenght, caméra to units 11075 Mains cord 11070 Modelling lamps (200-260 V) code Krypton lamp E27/100 W 23002 Halogen lamp E27/ 250 W/2000 hrs 23018 Halogen lamp 300 W/GX 6,35 23022 Halogen lamp 650 W/GX 6,35 23005 Modelling lamps (100-140 V) code Krypton lamp E27/100 W 23006 Halogen lamp E27/ 250 W/2000 hrs 23019 Halogen lamp 300 W/GX 6,35 23030 Halogen lamp 650 W/GX 6,35 23027 15

Visit our Web site : www.elinchrom.com 16 Elinca s.a E. Digital 3000 AS (73316) Printed in Switzerland