RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

Similar documents
RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

RMA42. Technical Information

Technical Information RIA45

Process transmitter RMA422

Process Transmitter RMA 422

Capacitance Level Measurement Electronic insert FEC 12

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

02/11/2015

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Inductive sensor BI1.5-EG08K-Y1

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor NI3-EG08K-Y1-H1341

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Inductive sensor NI10-M18-Y1X-H1141

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Level Measurement Point level measurement - RF Capacitance switches

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Oxymax W COS61. Technical Information. Dissolved oxygen measurement Optical sensor acc. to the fluorescence quenching principle

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Oxymax W COS71. Technical Information. Potentiostatic amperometric three-electrode sensor Long-term stable sensor for trace measurement

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

Inductive sensor With analog output BI15-M30-LI-EXI

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Level Measurement silometer FMC 420, FMC 423

DATA SHEET Panorama Rudder Indicator, TRI-2

Flow Measurement SITRANS F M

Wall-/Pipe-Mount Level Indicator

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

TFR5 Room or outdoor temperature sensor. CombiTemp TM

DMP 331i / DMP 333i LMP 331 i

IMPAC Infrared Thermometers

Technical Information Gamma Modulator FHG65 Synchronizer FHG66

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

CAPACITIVE SENSORS KAS. Series 26. Level Control Food Industry Pharmaceutical Industry Semiconductor Industry Chemical Industry

IMPAC Infrared Thermometers

Assembly. Front view. LEDs. Parametrization interface. Power Bus

TFRN Industrial RTD temperature sensor. CombiTemp TM

Capacitance Limit Detection nivotester FTC 420/421/422

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

DS 201. Electronic Pressure Switch. Ceramic Sensor. accuracy according to IEC 60770: 0.5 % FSO

Mechanical flow switch for On/Off control

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

LAUREL ELECTRONICS, INC.

Hybrid Chart Recorder 250 mm (10")

Signal conditioning instruments

Safety Light Curtains GuardShield

Level Measurement Point level measurement RF Capacitance switches

Single Point Flow Monitor SW118 SW119

Dissolved Oxygen Transmitter

Sentronic PLUS Electronic Pressure Regulator. Installation Manual

DCT 532. Industrial Pressure Transmitter with i²c interface. Stainless Steel Sensor

Actuators IC 20, IC 40

Model JDF Field Indicator

Generator protection relay

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Sensor technologies Distance measuring sensors Series SM6. Brochure

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

Signal conditioning instruments

TFR5 Room or outdoor temperature sensor. CombiTemp TM

Inductive linear position sensor LI300P0-Q25LM0-LIU5X3-H1151

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Material: Weight: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Dissolved Oxygen Transmitter

Material: Weight: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

SCALE & WEIGHT DISPLAYS

ACT20X Series for hazardous area applications Section A

Capacitive sensor BCT5-S18-UP6X2T-H1151

Material: Weight: Bearing Life: Shaft Speed: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

Fibre Optic Modem ODW-622

PROPORTIONAL VALVES Sentronic plus

Flow Measurement SITRANS F M

Material: Weight: Shaft Speed: Starting Torque: Storage Temp.: Shock: Vibration: Bump: Humidity: IP Rating: Cable: Connector: Flat Cable:

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Standard RS232 RS ma

Datasheet - SRB-E-201ST

TFRN Industrial RTD temperature sensor. CombiTemp TM

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Pendant Light Fitting IEC Series 6470/2

SITRANS F M. Transmitter MAG 5000/6000 4/33

PMG. Vibration Energy Harvesters

Transcription:

Technical Information RIA46 Field meter Digital field meter with control unit for monitoring and visualizing analog measured values Application Process recording and supervision Process control Signal adjustment and signal conversion Optional Ex approval Overfill protection according to WHG Your benefits 5-digit, 7-segment backlit LC display User-configurable dot matrix display range for bar graph, units and tag name 1 or 2 universal inputs 2 relays (optional) Min./max. value saved 1 or 2 calculated values One linearization table with 32 points for each calculated value 1 or 2 analog outputs Digital status output (open collector) Operation using 3 keys Configuration via interface and FieldCare software TI00142R/09/en 71132842

Function and system design Application Example for "differential pressure" application a0010572 The RIA46 field meter powers the transmitter and processes analog signals from transmitters, particularly from the area of process instrumentation. These signals are monitored, evaluated, calculated, saved, separated, linked, converted and displayed. The signals, intermediate values and the results of calculations and analysis are transmitted by digital or analog means. Measuring system Mathematics functions The RIA46 is a process transmitter, which is controlled by a microcontroller, and exhibits a display, analog inputs for process and status signals, analog and digital outputs, as well as an interface for configuration. Connected sensors (e.g. temperature, pressure) can be powered by the integrated transmitter power supply system. The signals to be measured are converted from analog to digital signals, processed digitally in the device, and then converted from digital to analog signals and made available to the various outputs. All measured values, and values calculated in any way, are available as a signal source for the display, all outputs, relays and the interface. It is possible to make multiple use of the signals and results (e.g. a signal source as an analog output signal and limit value for a relay). The following mathematics functions are available in RIA46: Sum Difference Mean Linearization Multiplication Linearization function Up to 32 user-definable points are available in the device per calculated value to linearize the input, e.g. for tank linearization. In the case of the two-channel device (option), mathematics channel M2 can be used to linearize mathematics channel M1. Linearization is also available in the FieldCare configuration software. 2 Endress+Hauser

Input Inputs Measured variable Measuring ranges Update time Linearization Galvanic isolation One or two universal inputs Current, voltage, resistance, resistance thermometer, thermocouples Current: 0/4 to 20 ma +10% overrange Short-circuit current: max. 150 ma Load: 10 Voltage: 0 to 10 V, 2 to 10 V, 0 to 5 V, 0 to 1 V, 1 to 5 V, ± 1 V ± 10 V, ± 30 V, ± 100 mv Max. permitted input voltage: Voltage 1 V: ± 35 V Voltage < 1 V: ± 12 V Input impedance: > 1 M Resistance: 30 to 3000 Resistance thermometer: Pt 100 as per IEC60751, GOST, JIS1604 Pt 500 and Pt 1000 as per IEC60751 Cu 100, Cu 50, Pt 50, Pt 46, Cu 53 as per GOST Ni 100, Ni 1000 as per DIN 43760 Thermocouple types: Type J, K, T, N, B, S, R as per IEC60584 Type U as per DIN 43710 Type L as per DIN 43710, GOST Type C, D as per ASTM E998 200 ms Linearization of input signals and calculated values possible over a maximum of 32 points. Towards all other circuits Endress+Hauser 3

Output Output signal Current/voltage output One or two analog outputs, galvanically isolated Current output: 0/4 to 20 ma Overrange up to 22 ma Voltage: 0 to 10 V, 2 to 10 V, 0 to 5 V, 1...5 V Overrange: up to 11 V, short-circuit proof, I max < 25 ma Loop power supply Open-circuit voltage: 24 V DC (+15% /-5%) Ex version: > 14 V at 22 ma Non-hazardous operation: > 16 V at 22 ma Maximum 30 ma short-circuit-proof and overload-proof Galvanically isolated from system and outputs HART : HART signals are not affected Status output Open Collector for monitoring of the device state and alarm notification. The OC output is closed in normal state. In error state, the OC output is opened. I max = 200 ma U max = 28 V U on/max = 2 V at 200 ma Limit function Relay contact Maximum contact burden DC Maximum contact burden AC Minimum contact load Galvanic isolation towards all other circuits Switching cycles Changeover 30 V / 3 A (permanent state, without destruction of the input) 250 V / 3 A (permanent state, without destruction of the input) 500 mw (12 V/10 ma) Test voltage 1500V AC > 1 million 4 Endress+Hauser

Terminal assignment Electrical connection Terminal assignment of the field meter 1: Connection socket for interface cable 2: Connection supply voltage 3: Connection relay 1 (optional) 4: Connection relay 2 (optional) 5: Connection analog and status output 6: Connection analog input 1 7: Connection analog input 2 (optional) 8: HART connection sockets 9: Laser labeling of terminal assignment a0010685 Supply voltage Power consumption Connection data interface Wide-area power supply unit 24 to 230 V AC/DC (-20 % / +10 %) 50/60 Hz Max. 21.5 VA / 6.9 W Commubox FXA291 PC USB interface Connection: 4-pin connector Transmission protocol: FieldCare Transmission rate: 38,400 Baud Interface cable TXU10-AC PC USB interface Connection: 4-pin connection Transmission protocol: FieldCare Delivery scope: Interface cable incl. FieldCare Device Setup DVD with all Comm DTMs and Device DTMs Endress+Hauser 5

Performance characteristics Reference operating conditions Maximum measured error Power supply: 230 V AC, 50/60 Hz Ambient temperature: 25 C ± 5 C (77 F ± 9 F) Humidity: 20 % to 60 % rel. humidity Universal input: Accuracy Input: Range: Maximum measured error of measuring range (omr): Current 0 to 20 ma, 0 to 5 ma, 4 to 20 ma; overrange: to 22 ma ± 0.05% Voltage 1 V 0 to 10 V, 2 to 10 V, 0 to 5 V, 1 to 5 V, 0 to 1 V, ± 1 V, ± 10 V, ± 30 V ± 0.1% Voltage < 1 V ± 100 mv ± 0.05% Resistance measurement 30 to 3000 4-wire: ± (0.10% omr + 0.8 ) 3-wire: ± (0.10% omr + 1.6 ) 2-wire: ± (0.10% omr + 3 ) Resistance thermometer Pt100, -200 to 850 C (-328 to 1562 F) (IEC60751, =0.00385) Pt100, -200 to 850 C (-328 to 1562 F) (JIS1604, w=1.391) Pt100, -200 to 649 C (-328 to 1200 F) (GOST, =0.003916) Pt500, -200 to 850 C (-328 to 1562 F) (IEC60751, =0.00385) Pt1000, -200 to 600 C (-328 to 1112 F) (IEC60751, =0.00385) Cu100, -200 to 200 C (-328 to 392 F) (GOST, w=1.428) Cu50, -200 to 200 C (-328 to 392 F) (GOST, w=1.428) Pt50, -200 to 1100 C (-328 to 2012 F) (GOST, w=1.391) Pt46, -200 to 850 C (-328 to 1562 F) (GOST, w=1.391) Ni100, -60 to 250 C (-76 to 482 F) (DIN43760, =0.00617) Ni1000, -60 to 250 C (-76 to 482 F) (DIN43760, =0.00617) Cu53, -50 to 200 C (-58 to 392 F) (GOST, w=1.426) 4-wire: ± (0.10% omr + 0.3 K (0.54 F)) 3-wire: ± (0.10% omr + 0.8 K (1.44 F)) 2-wire: ± (0.10% omr + 1.5 K (2.7 F)) 4-wire: ± (0.20% omr + 0.3 K (0.54 F)) 3-wire: ± (0.20% omr + 0.8 K (1.44 F)) 2-wire: ± (0.20% omr + 1.5 K (2.7 F)) 4-wire: ± (0.30% omr + 0.3 K (0.54 F)) 3-wire: ± (0.30% omr + 0.8 K (1.44 F)) 2-wire: ± (0.30% omr + 1.5 K (2.7 F)) Thermocouples Type J (Fe-CuNi), -210 to 1200 C (-346 to 2192 F) (IEC60584) ± (0.1% omr +0.5 K (0.9 F)) from -100 C (-148 F) Type K (NiCr-Ni), -200 to 1372 C (-328 to 2502 F) (IEC60584) Type T (Cu-CuNi), -270 to 400 C (-454 to 752 F) (IEC60584) Type N (NiCrSi-NiSi), -270 to 1300 C (-454 to 2372 F) (IEC60584) Type L (Fe-CuNi), -200 to 900 C (-328 to 1652 F) (DIN43710, GOST) Type D (W3Re/W25Re), 0 to 2495 C (32 to 4523 F)(ASTME998) Type C (W5Re/W26Re), 0 to 2320 C (32 to 4208 F)(ASTME998) Type B (Pt30Rh-Pt6Rh), 0 to 1820 C (32 to 3308 F) (IEC60584) Type S (Pt10Rh-Pt), -50 to 1768 C (-58 to 3214 F) (IEC60584) Type R (Pt13Rh-Pt), -50 to 1768 C (-58 to 3214 F) (IEC60584) Type U (Cu-CuNi), -200 to 600 C (-328 to 1112 F) (DIN 43710) ± (0.1% omr +0.5 K (0.9 F)) from -130 C (-202 F) ± (0.1% omr +0.5 K (0.9 F)) from -200 C (-328 F) ± (0.1% omr +0.5 K (0.9 F)) from -100 C (-148 F) ± (0.1% omr +0.5 K (0.9 F)) from -100 C (-148 F) ± (0.15% omr +1.5 K (2.7 F)) from 500 C (from 932 F) ± (0.15% omr +1.5 K (2.7 F)) from 500 C (932 F) ± (0.15% omr +1.5 K (2.7 F)) from 600 C (1112 F) ± (0.15% omr +3.5 K (6.3 F)) for -50 to 100 C (-58 to 212 F) ± (0.15% omr +1.5 K (2.7 F)) for 100 to 1768 C (212 to 3214 F) ± (0.15% omr +3.5 K (6.3 F)) for -50 to 100 C (-58 to 212 F) ± (0.15% omr +1.5 K (2.7 F)) for 100 to 1768 C (212 to 3214 F) ± (0.15% omr +0.5 K (0.9 F)) from -100 C (-148 F) AD converter resolution 16 bit 6 Endress+Hauser

Temperature drift Temperature drift: 0.01%/ K (0.1%/18 F) omr 0.02%/ K (0.2%/18 F) omr for Cu100, Cu50, Cu53, Pt50 and Pt46 Analog output: Current Voltage Resolution 0/4 to 20 ma, overrange to 22 ma Max. load Max. inductance Max. capacitance Max. ripple 0 to 10 V, 2 to 10 V 0 to 5 V Overrange: up to 11 V, shortcircuit proof, I max < 25 ma Max. ripple 13 bit ± 0.05% of measuring range 500 10 mh 10 F 10 mvpp at 500, frequency < 50 khz ± 0.05% of measuring range ± 0.1% of measuring range 10 mvpp at 1000, frequency < 50 khz Temperature drift Galvanic isolation 0.01%/K (0.1%/18 F) of of measuring range Testing voltage of 500 V towards all other circuits Installation Installation instructions Mounting location Field, direct wall mounting and wall or pipe mounting 1) using the optional mounting plate. Orientation The orientation is determined by the readability of the display. Max. viewing angle range +/- 45 from the central display axis in every direction. Environment Ambient temperature range! Note! -40 to +50 C (-40 to 122 F) Readability of the display cannot be guaranteed at temperatures below -30 C (-22 F). Storage temperature -40 to +85 C (-40 to 185 F) Operating height < 2000 m above MSL (6561 ft) Shock and vibration 3g at 2...150 Hz as per IEC 60068-2-6 Climate class As per IEC 60654-1, Class B2 Degree of protection Front IP 67 / NEMA 4x (not evaluated by UL) 1) According to UL approval panel or surface mounting only. Endress+Hauser 7

Electrical safety housing Protection class I, overvoltage category II, pollution degree II for aluminium housing Protection class II, overvoltage category II, pollution degree II for plastic housing Condensation permitted Electromagnetic compatibility (EMC) Interference immunity: To IEC 61326 industrial environments / NAMUR NE 21 Interference emissions: To IEC 61326 Class A Mechanical construction Design, dimensions Dimensions of the field meter A: Drill-hole for direct wall mounting or on optional mounting plate with 4 screws 5 mm (0.2") a0010574 Weight Material Plastic housing: approx. 600 g (1.32 lbs) Aluminum housing: approx. 1700 g (3.75 lbs) Housing: Plastic PBT-GF30 or aluminum Terminals Plug-in spring terminals, 2.5 mm 2 (14 AWG); auxiliary voltage with screw terminals (AWG 30-12; torque 0.5-0.6 Nm (4.4-5.3 lb in)). 8 Endress+Hauser

Human interface Display elements Display of the field meter 1: Channel display: 1: analog input 1; 2: analog input 2; 1M: calculated value 1; 2M: calculated value 2 2: Dot matrix display for TAG, bar graph and unit 3: Limit value indicators in the bar graph 4: "Operation locked" indicator 5: Green LED; measuring device operational 6: Red LED; error/alarm 7: Yellow LED; status of relay 1 8: Yellow LED; status of relay 2 9: Minimum/maximum value indicator a0010575 Display 5-digit, 7-segment backlit LC display Dot matrix for text/bar graph Display range -99999 to +99999 for measured values Signaling Setup security locking (lock) Measuring range overshoot/undershoot 2 x status relay (only if relay option was selected) Operating elements Remote operation 3 keys: -, +, E Configuration The device can be configured with the PC software or on site using the operating keys. FieldCare Device Setup is delivered together with the Commubox FXA291 or TXU10-AC (see Accessories ) or can be downloaded free of charge from www.endress.com. Interface 4-pin socket for the connection with a PC via Commubox FXA291 or TXU10-AC interface cable (see 'Accessories') Endress+Hauser 9

Certificates and approvals CE mark Ex approval Other standards and guidelines The device meets the legal requirements of the EU directives. Endress+Hauser confirms that the device has been tested successfully by affixing the CE mark. Information about currently available Ex versions (ATEX, FM, CSA, etc.) can be supplied by your E+H Sales Center on request. All explosion protection data are given in a separate documentation which is available upon request. IEC 60529: Degrees of protection by housing (IP code) IEC 61010-1: 2001 Cor 2003 Safety requirements for electrical equipment for measurement, control and laboratory use EN 60079-11 Explosive atmospheres - Part 11: equipment protection by intrinsic safety "I" 10 Endress+Hauser

Ordering information Product structure RIA46 Universal process transmitter. 1/2 channel, scalable universal input. LC display, 7-segment range, 5-digit, user-configurable dot matrix range with bar graph/unit/channel name. Linearization, limit function, min./max. value memory, alarm memory. 3-key operation, 4 status LEDs. Transmitter power supply. Basic unit: 1x universal input, 1x analog output. Approval: A1 Non-hazardous area B1 ATEX II(1)GD [Ex ia] IIC CP CSA General Purpose E1 CSA AIS, NI/I/2/ABCDEFG/T4 F1 FM AIS, NI/I/2/ABCDEFG/T4 G1 TIIS [Ex ia] IIC N1 NEPSI [Ex ia] IIC Input; output: A 1x universal; 1x analog B 2x universal; 2x analog C 1x universal; 1x analog + 2 relays D 2x universal; 2x analog + 2 relays Housing: 1 Field plastic, glass reinforced 2 Field, Alu Thread: A 4x M16, 1x M20 B 5x NPT 1/2" RIA46- Order code (part 1; 1 attribute per category must be selected.) Additional selection (as option - no selection or multiple selection is possible) Cable Entry: A1 4x M16, 1x M20 A3 4x adapter M16 to M20 Mounting: B1 Mounting kit wall+pipe Additional Option: C1 Customised pre-installed C2 Works calib. certificate C9 Special version, TSP no. to be specified Version: D1 SIL 2 D2 WHG D3 Power-Plant saismically tested D4 GL marine certificate D5 UL listed Accessory: E1 Configuration kit TXU10 E2 Weather protection cover Marking: Z1 Tagging (TAG), metal Z2 Tagging (TAG), on device Z3 Commissioning label, paper Z6 Tagging (TAG), supplied by customer RIA46- + Order code (complete) Endress+Hauser 11

Accessories PC operating software FieldCare Interface cable Order No. FXA291 TXU10-AC Name Commubox FXA291 incl. FieldCare Device Setup and DTM library Commubox TXU10 incl. FieldCare Device Setup and DTM library Mounting kit Order no. Name 71089844 Pipe mounting kit with plastic mounting plate (for pipes with 1-5 inches) 71091611 Pipe mounting kit with stainless steel mounting plate (for pipes with 1-5 inches) Documentation Overview brochure: System components: FA016K/09 Operating Instructions for 'Field meter RIA46 : BA00274R/09 Supplementary Ex documentation: ATEX II(1)GD [EEx ia] IIC: XA079R/09/a3 12 Endress+Hauser

Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel.+41 61 715 81 00 Fax+41 61 715 25 00 www.endress.com info@ii.endress.com TI00142R/09/en/01.11 71132842 FM+SGML6.0 ProMoDo