w w w. e m c t e s t. i t

Similar documents
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

R&S MDS-21 Absorbing Clamp Measurement of disturbance power and screening effectiveness on cables

Microwave Counter, Power Meter and DVM in One Portable Package

Cryostat Instrumentation Cabling Grounding and Shielding. Eric Hazen Boston University 12/15/08 1

Fibre Optic Modem ODW-622

PAM-1840 Preamplifier Operation Manual

Model AS40030, -RS, -RE AR System 10kHz-40GHz

LW10-T600. P10 Led Wall Display

DA E: Series of Narrowband or Wideband Distribution Amplifiers

LONWORKS Fibre Optic Converter

Cable guide. for. High Performance Controllers and TeleControllers. Cable types and wiring guidelines

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

R&S DST200 RF Diagnostic Chamber Specifications

INSTALLATION MANUAL FT-FOTR-1VDE-ST-S

National Park Service Photo. Utah 400 Series 1. Digital Routing Switcher.

PRODUCT SPECIFICATION Date: VESTEL

ODW-621. RS-232 Point-to-point applications

R&S ZN-Z154 Calibration Unit Specifications

PRODUCT SPECIFICATION Date: VESTEL

Parameter Symbol Units MIN MAX. RF Input Power (CW) Pin dbm +20. LO Input Power (CW) Pin dbm +27

RF Characterization Report

IFM65UG OPS-COMPLIANT 16/7 400 NITS ULTRA HD INTERACTIVE FLAT PANEL DISPLAY

Model Camera System (CCTV) User Manual

Fibre Optic Modem ODW-611

LONWORKS Fibre Optic Router

Fibre optic router for TP/FT-10 LRW-112PP

MRI SAFETY CONNECTION GUIDE

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

DA MHz Series of Narrowband or Wideband Distribution Amplifiers

OM2000N INSTALLATION MANUAL

1Chapter INTRODUCTION. This chapter describes the CST-5000 C-Band satellite terminal, referred to in this manual as the CST-5000 (Figure 1-1).

DA : Series of Narrowband or Wideband Distribution Amplifiers

R&S ZVA110 Vector Network Analyzer Specifications

LTC 113x & LTC123x FlexiDome Series Fixed Dome Cameras

STM49UG02 49 SOC BASED/OPS COMPLIANT 16/7 FULL HD DIGITAL SIGNAGE DISPLAY

INSTALLATION MANUAL FT-FOTR-8VD-ST-S. 8-Channel Digital Duplex Baseband Video Transmitter and Receiver With Reverse Data Transmission for PTZ Cameras

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

SURFACE MOUNT HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Versatile EMS and EMI measurements for the automobile sector

IMPAC Infrared Thermometers

Parameter Input Output Min Typ Max Diode Option (GHz) (GHz) Input drive level (dbm)

USER GUIDE. AXIS T8640 Ethernet Over Coax Adaptor PoE+ ENGLISH

R&S CEMS100 Compact EMS/EMI Test Platform Standard-compliant all-in-one solution for EMS measurements

18 GHz, 2.2 kw KLYSTRON GENERATOR GKP 24KP 18GHz WR62 3x400V

The performance of a lifetime. Owner s Manual MOON 110LP v2 Phono Preamplifier

MTI-2100 FOTONIC SENSOR. High resolution, non-contact. measurement of vibration. and displacement

R&S FPC-Z10 Teaching Kit Getting Started

ThinkRF D GHz RF Downconverter

Filters for Power Lines (Low Leakage Current)

TOSHIBA Industrial Magnetron E3328

Product Brochure Version R&S ENV A Four-Line V-Network RFI voltage measurements at high currents

THE ART OF ENGINEERING

AMU2-2MHD+ Audio monitoring Unit

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

OPERATION NOTES FOR PSIDEX AUDIO PGP-1A PRE-AMPLIFIER DESCRIPTION INSTALLATION

Model FS-4608SR. Features. Overview

The Art of Engineering

GaAs MMIC Double Balanced Mixer

NI PXI/PXIe-2543 Specifications

GaAs MMIC Double Balanced Mixer

GaAs MMIC Double Balanced Mixer

GaAs MMIC Triple Balanced Mixer

Bluetooth Tester CBT. Specifications. Specifications. Version January 2006

MAX2660/MAX2661/MAX2663/MAX2671 Evaluation Kits

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

FLEXIBLE SERIES DA LR WW LENTUS

Requires half the number of feeder cables

R&S AMU-Z7 Analog I/Q Combiner Technical Information

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

D21DKV IP VIDEO DOOR STATION. Brushed Stainless Steel Display Module Keypad Module

GaAs DOUBLE-BALANCED MIXER

D21DKV IP VIDEO DOOR STATION. Display Module Keypad Module

GaAs DOUBLE-BALANCED MIXER

R&S ZN-Z85 Switch Matrix Specifications

GaAs DOUBLE-BALANCED MIXER

Drop Passives: Splitters, Couplers and Power Inserters

MKH 8060 Directional studio microphone

ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE STANDARD SCTE

Directional Couplers and Splitters

RSSL1:1-KuXER. Outdoor Unit (ODU) Ku Ext Ref LNB Redundancy System with external 10 MHz Reference System. Mux/Tee. Coax cable

Multiple Band Outdoor Block Up- and Downconverters

Sensoray. Model 819. Tests Conducted by: ElectroMagnetic Investigations, LLC. May 10, 2013

GaAs DOUBLE-BALANCED MIXER

Test Systems. Typical JFW Systems. Matrix switches Programmable assemblies Switch assemblies Manual attenuator assemblies Power divider assemblies

PROFESSIONAL 2 CHANNEL SOLID-STATE MIC / LINE PREAMPLIFIER USER S MANUAL

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

Miniature, Ruggedized 20 GHz RF over Fiber Transmitter

Fiber-coupled light sources

PDX75U36/6. 75" Professional Extra Bright Signage Displays. Key Features. Open Platform Support. OPS Support. Pixel Shifting.

FiberLink 7142 Series

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

R&S RT-Zxx High-Voltage and Current Probes Specifications

PSC RF Multi SR Six Pack

R&S DST200 RF Diagnostic Chamber Accurate radiated testing of wireless devices 700 MHz to 6 GHz

Optical Fiber Link, 0.1~ 20 GHz RF Over Fiber, I-IFLRF12

ITER Product Catalogue. Total Pressure Measurement V Page 1 / 15

ZDC RF Coax Connector Series 50 & 75 Ohm

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

Transcription:

GTEM EMC 1000 - INOX Frequency Range: 100KHz to 20GHz Max. Power-Input: 1000 W Input Connector Type: N (Female) Nominal Impedance: 50 Ω Typical VSWR: 1:1.2 Power Line Filter: 2x 230V AC/DC 16A RF Coax Feed-Thru(s): 1x SMA + 1x N (Females) Other Feed-Thru(s): Installed options: Dimensions: INOX; PLF-16S; FOPT-1; FT-N; FT-SMA; WHEEL 1000 Septum Height: Door Size: Uniform Area Size ±3dB: Reference Standards: EUT Max Size: EN 61000-4-3 - EN 61000-4-20 Weight: 1x 3 Fiber optical cable 495(L) x 280(W) x 220(H) 1150 mm 80(W) x 80(H) cm 41(L) x 41(W) x 37(H) cm 82(L) x 82(W) x 74(H) cm 900 Kg Introduction The GTEM cell is a TEM waveguide with the upper frequency limit extended to the GHz range. It is under consideration as an alternative measurement facility for both radiated emission and immunity measurements. It is included in the recently published standard IEC 61000-4-20 Emission and Immunity Testing in Transverse Electromagnetic (TEM) Waveguides. Theory of operation GTEM-cells (Giga-hertz Transversal Electro-Magnetic cells) are waveguide structures intended for electromagnetic compatibility measurements, as well as biomedical applications. The electromagnetic field distribution inside the cell is in TEM mode. With TEM mode propagation, there is no component of electric and magnetic field in the direction of propagation of electromagnetic wave. Therefore the field components are strictly perpendicular. Assuming the field distribution ideal TEM below the cut-off frequency of the cell (before the introduction of higher order modes), the electromagnetic field distribution can be considered static. Key Features Engineered and completely manufactured in Italy. Ruggedized fully INOX steel construction Unique compact design. Optimized for EMI and EMC. Strong fields achieved with low input power Broadband up to 20Ghz High effective shielding Fully customizable feed thrus and filters Excellent quality at Low cost Pag. 1 of 10

Applications EMI and EMS devices Radiation and susceptibility test Specifically designed for telecom application Biomedical and dosimetrical applications Isotropic sensors calibration Receiver sensitivity test Available options INOX INOX rugged construction EIA 7/8 EIA 7/8'' Input Connector (max. 3GHz) EIA 7/16 EIA 7/16'' Input Connector (max. 3GHz) ESI-250 Electrical safety interlock FOPT-1 Channel for fibre optic leads (1 fiber pair) FOPT-3 Channel for fibre optic leads (3 fiber pairs) FPT-DB9 Filtered 9-poles pass-thru RS-232(DB9) FPT-DB25 Filtered 25-poles pass-thru RS-232(DB25) FPT-DC10 Filtered 10A 1000V DC banana socket pass-thru FT-BNC RF feed-thru BNC-BNC Female panel mount type connector FT-N RF feed-thru N-N Female panel mount type connector FT-BNC/SMA RF feed-thru BNC-SMA Female panel mount type connector FT-RJ45 Shielded RJ45 (RJ11) feed-thru female-female connector FT-SMA RF feed-thru SMA-SMA Female panel mount type connector HCOMB-10 Honey comb 10x10 cm air intake/outtake HPTER-1000 Hi Power terminations 500W continuous power up to 3GHz ILED Indoor LED lighting 50W shielded lamp IP-CAM Shielded RJ45 IP camera system PDTP Technical panel pre-drilled for options with EMC gaskets and inox bolts PLF-20S Single Phase AC Power Line Filter 2x 20A Phase+N+Ground PLF-40S Single Phase AC Power Line Filter 2x 40A Phase+N+Ground PLF-60S Single Phase AC Power Line Filter 2x 60A Phase+N+Ground PLF-20T Tri Phase AC Power Line Filter 4x 20A 3Ph+N+Ground PLF-32T Tri Phase AC Power Line Filter 4x 32A 3Ph+N+Ground PLF-64T Tri Phase AC Power Line Filter 4x 64A 3Ph+N+Ground DCF-120 Single pole Filtered AC/DC Feedthru 120A 1700VDC/250VAC PWS Additional Power Socket for EUT SAE Door for tests acc. to SAE J1752/3 Integrated Cir SHW-L Only for GTEM 750/1000/ Shielded Window in door 1250/ 1500/ 1750/2000 WLIP-CAM Shielded IP camera system WHEEL-1000 Wheeled undercarriage with brakes Pag. 2 of 10

Detailed views Pag. 3 of 10

Technical Panel The GTEM is provided with a technical panel equipped with various types of connections properly shielded that allow access to the interior test volume without allowing contamination of the internal field. Technical panels are fully configurable to meet any input output specific requirement. Two extra empty panels are available for future expansions. Technical Panel FOFT - Fiber Optic Feed Thru FT-DB9 - Filtered DB9 Feed Thru N + SMA - Feed Thrus Empty technical Panels for future expansions Pag. 4 of 10

Power Filter To ensure the suppression of disturbances coming from the power supply line, an AC/DC filter is installed in the filter. The filter works also in the other way round avoiding that any disturbance produced by the DUT goes back to the land line. Custom power line filters are available for any specific need. Power filter box may incorporate internal illumination lamp and power on switch. Pag. 5 of 10

Internal illumination Internal illumination is produced by a replaceable 6.5W GU10 spotlight equivalent to traditional 50W lamps installed in the power filter. A tiny inox steel meshed foil installed in front of the lamp guarantees shielding. Avoid touching it or bumping into it. It is very fragile. In case of damage the filter box must be sent to service. Pag. 6 of 10

Shielded door The door installed on the GTEM is shielded by means of two rows of metal mesh gaskets. Closing the door, the pressure crushes the edge of the hinges on the metal seal so as to avoid contamination of the internal field. Toggle clamps Door gaskets Pag. 7 of 10

Shielded window on door The door is equipped with a shielded window made of polycarbonate glass incorporating a very thin meshed metal foil that proves the required shielding. RF Absorbers The panel opposite to the tip, also known as the back of the GTEM is covered with a pyramidal shaped spongy material loaded with graphite able to absorb the RF field which invests it. Such material is realized in panels of 3x3 tiled pyramids. Each panel is applied to the base with Velcro straps In case of damage the damaged panel can be easily removed and replaced with a new one. Such operation must be performed by specialized personnel of EMC TEST service center. Pag. 8 of 10

Apex The N Female connector at the apex is the connection interface of the GTEM cell to a receiver or spectrum analyzer for emission testing as well as it is used to connect a generator together with a power amplifier for immunity testing. Handles for handling The GTEM is provided with four handles for handling. Two of them are close to the apex and the other two are located at the sides in the back. To move the GTEM at least two people are needed. One in the back and one in the front. Before trying to move the cell make sure that the brakes of the wheels are removed. Pag. 9 of 10

Assembly and Delivery Because of its large size and weight, EMC GTEM 1000 is shipped disassembled in a proper shock-resistant packaging and assembled on-site by professional personnel. Pag. 10 of 10