Instrukcja montażu. FLEX LED Neon Instalacja

Similar documents
INSTALLATION INSTRUCTIONS RGB / RGBW 24V LED TAPE

PRODUCT MANUAL. Product Description. Product Features. Manual will Review. LED Mini Neon 80W 24V DC. LED Mini Neon 80W 24V DC

RGB 5050 PixelControl LED Super Flat Rope Part Numbers: PSFR-RGB-W-20

2179-CD Series Fiber Optic Splice Closure. Installation Instructions

24 Volt RGB/RGA Super Flat LED Rope Part Numbers: SFR-RGB-W, SFR-RGB-B, SFR-RGA-W, SFR-RGA-B

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

Assembly Instructions

Gigabit Multi-mode SX to Single Mode LX Converter. User s Manual NGF-728 Series. Warning COPYRIGHT

INSTALLATION MANUAL. ION Series FIBER OPTIC ILLUMINATOR IP67 OUTDOOR RATED

LED Spot 300W. Please read this user manual before your operation

LAMPS & INDICATOR LAMPS

SECTION COMMUNICATIONS HORIZONTAL CABLING

LED Flexible strip. Specification UCS1903 LED STRIP. Product Name HTD-1903XX-X. Product Number V1.0. Version Number. Page

USER MANUAL. DE-1 Police-light. CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

Instructions. Cable with Armor F CAUTION. October Rev A

INDICATOR LAMPS & LED REPLACEMENT LAMPS

PrimaLine 1.5 XT Wet Location LED Tape Light

FLUID VIEW 12V LED TAPE LIGHT

Bill of Materials: Super Simple Water Level Control PART NO

Cyclo Series. user manual. MartinArchitectural

Installation Manual SaVi Note Underwater LED Light

Power Injector 1520 Series

PRODUCT SPECIFICATIONS

PEM1126ENG ENGLISH STPKR. TERMINATION KIT FOR PAPER CABLE WITH LEAD SHEATH 1 kv INSTALLATION INSTRUCTION

.Power Distribution Center. PD-1. Instruction Manual

LENGTH LEAD WIRES LENGTH. Lead wires at one end. Lead wires at both ends. See length ordering guide. Standard is 0975(975mm)

Spectra Batten (Order code: LEDJ95)

3M Cold Shrink QS-III Silicone Rubber Splice Kit 5488A-TOW/WOT

100Base-FX Multi-mode to 100Base-FX Single Mode Converter. NXF-708 Series User s Manual

ART 7 SERIES PROFESSIONAL ACTIVE SUBWOOFERS. a new generation of speakers is born and it s ready to rock audiences all over the world

Cellular Signal Booster

Warnings and Precautions

INVISILED ACCESSORIES

TVAC20000 User manual

Winmate Communication INC.

1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

Product Manual. Designed and Manufactured in the UK by Optikinetics

Monochrome Video Monitors

Led Dynamic DMX Tri Curtain Manual

PVS (PERSONAL VEIWING SYSTEM) INSTRUCTION MANUAL

DMX LED light effect with 4 lenses

Water blocking tape. Locator ridge HPA-0486

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

3M Cold Shrink QS4 Integrated Splice Kit QS4-15JCN

TruLine 1A 24VDC - BUILD-IT-YOURSELF PLASTER-IN LED SYSTEM

Closet lighting, CA PrimaLine 3 tape in Surfa 1 channel

VITALink Taped Splice Straight Through Crimp

ALTOS LITE Loose Tube, Gel-Free Cables with FastAccess Technology, Fibers

INSTALLATION MANUAL. 4. Chase all cables into the wall at the bottom of the TV to reduce chances of water reaching the TV.

USER MANUAL. 22" Class Slim HD Widescreen Monitor L215DS

Chip3 Inline Ultraslim RGB Multi Pixel

Cable Installation Tips

10.4" LCD Monitor with Aluminum Front Bezel YPM1040PHB

Automatic Connector MHV Connectors MHV Introduction MHV series connectors Contents Polarized mating interfaces Anti-Rock mating interfaces

LIGHT COPILOT II. elationlighting.com Internet:

DisplayPort Extender over 2 LC Fibers

Site Installation Model MP-8424

User guide. Preamble. unpacking

Galaxias. Flex LED display. User Manual

18W Low Energy Dusk-Dawn Bulkhead E-290B

USER MANUAL Full HD Widescreen LED Monitor L236VA

USER MANUAL. 27 Full HD Widescreen LED Monitor L27ADS

IP-LINX Fiber :: X-XXXX

NewScope-7A Operating Manual

Instructions for Use P.154-UP (9/4) P.155-UP (9/8) P.150-UP-12 (9/12) P.150-UP-16 (9/16)

UMN_ User Manual Antenna Simplex. TECHNO-MEDIA srl Via IV Novembre 92, Bollate (MB) tel

User Manual. Color video door phone CDV-70P PM0770P Printed In Korea /

Operating instructions

SquareLED - Aura Bar & Matrix Beam Light 100

01. Stay safe. Privacy information

Operating Instructions

Stratos Duo RGB. User Manual. Order code: EQLED371

PLL1920M LED LCD Monitor

3M Cold Shrink Splice Kit QS-III 5515A

User Manual Color Video Door Phone

Optical Distribution Box 300 Installation Guide. Version : R0.0

TruLine.5A BIY, 24VDC

CU103 User Manual. Contents

Installation Guide VL-MV10. Model No.

FTTH & FITH. Discreet optical fiber solutions from the network connection point to the set-top box.

HYDROLUME LED STRIP LIGHT

USER MANUAL Full HD Widescreen LED Monitor L215ADS

TSUBAKI SEAMLESS LIGHT TYPE V

User Manual Color video door phone

USER MANUAL Full HD Widescreen LED Monitor L215IPS

User Manual Color video door phone

DIY. How to install a PL-259 connector. Parts list: Tools list: Worthwhile projects you can build on your own

VISION. Our Vision of what 120V LED Linear Should Be.

LEDs. Types and Uses. By Wil Davis June 18, 2016

PEM1124ENG ENGLISH. STK TERMINATION KIT FOR PLASTIC CABLE WITHOUT ARMOURING 1 kv STKR TERMINATION KIT FOR PLASTIC CABLE WITH ARMOURING 1 kv

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

HTP1502W1 Remote Controlled Multicolor Lighting System

EC Series Creativity Accessories Safety and Installation Guide

24-Fiber LANLINXS (Model # ) 48-Fiber LANLINXS (Model # ) User Manual

ORLAND SCAN PR PR LIGHTING LTD. Yingbin Road, Dashi Panyu, Guangzhou, China

3M Cold Shrink Splice Kit QS-III 5514A

TFT-150R-G. Tape Shield Cable (page 2) Suggested Installation Equipment (not supplied with kit) Wire Shield Cable (page 7)

I1000M Rough-In Instructions

ITC-200B Quick Start Guide

Installing a Wire Mesh Pulling Grip on All-Dielectric DX Armored Fiber Optic Cables

Transcription:

FLEX LED Neon Instalacja Instrukcja montażu Polned Sp. z o.o. ul. Falencka 7 PL05-090 Janki Tel. +48 22 4903434 +48 22 4903243 www.polned.pl info@polned.pl.

Product Checking: 1) Unpack and carefully examine the product. 2) Report any damage and save all packing material if any part is damaged during the transported 3) Do not attempt to use this device if it is damaged. Cautions: 1) This device shall be installed and operated by a qualified electrician or technician in accordance with all relevant local codes. 2) Risk of electric shock. Ensure that the power supply is off when wiring or soldering the sections of the device 3) Do not use metal wires to tie the LED neon. 4) Do not mount LED soft neon on a heat emitting object. 5) Make sure LED soft neon is installed in a well ventilated place. Working Environment: This product is suitable for indoor and outdoor use, and applicable for both dry and damp environments. User responsibilities It is the responsibility of the contractor, installer, purchaser, owner, and user to install, maintain, and operate the device in such a manner as to comply with all state and local laws, ordinances, and regulation Note: The instructions and precautions set forth in this user guide are not necessarily all-inclusive, all conceivable, or relevant to all applications, Easeking cannot anticipate all conceivable or unique situations. Operation instructions: RGB LED Neon Working With Controllers: 1. Color changing mode: 7 colors changing in sequence from left to right (including B, RG, GB, and RGB 7colors) 2. Color chasing mode: 7 colors running in sequence from left to right (including B, RG, GB, and RGB 7colors) 3. Full color changing (slow fade/slow glow and skip) (including B, RG, GB, RGB 7 colors); 4. Multi section color changing, chasing or skipping; 5. Controller can be programmed according to customer s specific requirement and to replace the functions of glass neon.

Usage instruction Installation The LED neon installation requires planning to ensure timely, successful installation with minimal complications and down time. Suggestion Consult an Electrical Inspector to review all wiring plans. Create a Layout Plan drawing, per a Lighting Designer's or Architect's recommendation. Consult Easeking Electric Application Engineering Services as needed. Cutting your Neon light Cut your Neon light to your desired length for any application. Neon lights are able to cut in specific intervals only. These vary depending on the number of wires your neon light contains. For example, the red neon light is cut in 100cm intervals under 220VAC. A careful examination of the exterior of the neon light casing will reveal tiny scissor icons. These icons mark the increment where it is safe to cut your neon light. First, calculate the interval that will work for your application. For our Neon light example with a cutting interval of 100cm under 220VAC, this can be done by taking the number of meter you need. If you have an even number you have a even interval of 100cm and you can simply count the intervals or measure the desired number of meter and cut at the scissor icon. If you do not have an even number you will need to choose the next closest interval and cut appropriately. To cut, use our neon light cutter tool or a pair of scissors to snip the Neon lighting at the You are now ready to attach a power cord, End cap, specified mark. Be sure to make a clean vertical cut to avoid a short. Now bend the Neon light to the left and to the right and trim off any excess wire that might protrude. Important: Failure to cut at the marked interval will result in damage to your neon lights.

Power Cords & Connectors 1. Connecting LED neon to power cord; connecting power connector to LED Neon A1: Push the sharp side of the pin connector into one end of the LED neon. B1: Push the flat side of the pin connector into the power connector and make sure the pins fit into the slot. 2. Waterproof treatment before connecting power connector to LED neon. A2: Squeeze the clear silicon glue on gap between the metal pin and led neon flex, Push the LED neon with male pin connector into the slot of the power connector. B2: Hot the Connect parts by Air Blower. C2: Squeeze the clear silicon glue into the extra space of the slot to full. D2: Hot the heat shrinks by Air Blower. A1 B1 A2 B2 C2 D2 The Rectifier box is used to transform the AC current to DC because our led chips are always worked under DC Current.

Connecting splice connector (T, L, I Shape Connector) 3. Connecting LED neon with easy splice connector A3: Position the easy splice connector to make sure the sharp ends of the pin can well push into both pieces. B3: Use shrink tube to heat and tighten the connecting place. C3: Push the sharp side of the pin connector into one end of the LED neon, Do connect them together by Two Side E3: Squeeze the glue in gap two led neon flex. F3: Hot the heat shrinks by Air Blower. C3 E3 F3 Warning: Only connecting 2 pieces of LED neon with the same voltage and specifications. 4. Installing End Cap A4: Use PVC end cap with glue to cover and seal the end of the LED neon. B4: Heat the heat shrinks by Air Blower. Use shrink tube or tie strip to further fix the end cap. B4 C4

Fix the Neon Light 1. Aluminum & PVC Mounting Track Can be used for a more professional look which will support an entire run of neon light giving you the straightest run possible. Use a good adhesive or screws to mount the track and then simply push the neon lighting into the track. We could provide the 100cm or 5cm aluminum channel for choice. Warning: Please don t fix like follow 110V/220VDC LED Neon 12V/24VDC LED Neon 1. Power Plug 2. Transformer From AC to DC 1. Power Plug 2. Transformer from 110/220VAC to 12V/24VDC 3. Transformer From AC to DC

FAQ's For complete neon light installation instructions click here. How easy is it to work with neon lighting? Very easy - Simply cut the neon light at one of the marked intervals with a pair of scissors. For the 120/220-volt version, a power cord and power connector is used at one end of the neon light so that it may be to plugged into any standard household outlet. The 12-volt and 24-volt versions are essentially the same, but utilize low-voltage bulbs and a hard wired cord. 12-volt or 24-volt must be hooked up to the appropriate power source. In all instances and end cap terminates each run. NOTE: Always ensure that you have power turned off before cutting. How will I know where I can cut the neon light? On every piece of neon light, there are tiny marks or scissor icons indicating the interval where it is safe to cut. For 120/220 Volt neon light, these marks are every 2 meter. NOTE: Cutting a neon light at another length other than the marked interval will cause the neon light to fail. Can the neon light be used outdoors? Yes, our neon lights can be used indoors or outdoors including applications such as architectural accent, indirect lighting, on stairs, stair rails, windows, stages, exhibits, displays, night clubs, pools, spas, patio areas, in landscapes, and much more. When used outdoors under heavy use or in damp areas, we recommend the use of our neon light glue or another silicon based sealant. Is flexible neon light waterproof? Yes, neon light is generally waterproof if installed correctly. However, it is not recommended that they be submerged. Neon lights are vulnerable to water seepage at their connections when they are continuously exposed to water and may pose a risk if used under water. Extreme caution should be used when dealing with 120/220 volt electricity under water. How do I mount neon lighting? Mounting neon lights by aluminum channel. How many mounting clips should I buy? Mounting clips are fairly inexpensive. It depends on your application, but we generally recommend one per meter of neon light or more in sections that have a sharp bend. Can I form a sharp bend with flexible neon light? No, you cannot have a sharp or a crimped bend. While neon lighting is flexible to nearly 180 degrees, you must maintain a small radius on your bend. Your max bend should be short 12.5mm What type of accessories do I need? For the majority of connections, you will need a power cord, a power connector, and an end cap to make one complete run. Enough FREE accessories are included to make 1 separate runs with every spool, including 1 pieces power cord of neon light together. Other accessories are available including invisible splices, L-connectors, T-connectors, male to female extensions, female to female extensions, and more. Can I change colors in a single run? Yes you can. Using an Inline Splice, Invisible Inline Splice, or T connector, you can join two or more different colors together. What happens if one bulb burns out? If one bulb burns out then a section of that interval will not function. The remainder of the neon lights will continue to operate. The faulty section can be repaired by splicing in a replacement section using in line splices or invisible inline splices and heat shrink tubing. What are the maximum run lengths? The maximum run for 120/220-Volt neon light is 200meter. The maximum run for 12 volt neon light is 10meter. The maximum run for 24 volt neon light is 20meter. If you need to run a greater length you will need to power the next set from the source rather than adding more to the end of the run. Can the neon lights be dimmed? Yes, for 120/220 volt, a standard light dimmer works fine. Ensure that you are using a light dimmer with the wattage capability to support the length of neon lights you wish to operate. Can I "hardwire" the 120/220-volt neon lighting? Yes, you may hard wire your neon lighting by simply cutting off the plug and exposing the wires.

CAUTION: Electrical codes vary significantly. Before hard wiring it would be best to check with a licensed electrician that is familiar with the electrical code in your area. 1. Careful on reading User of LED Neon Flex before installation. 2. Don t Light the LED Neon Flex when the LED Neon Flex On the reel. 3. Cut the LED neon follow the Cut Mark Hints. 4. Cut the copper wire and clean smooth. 5. Make sure the operating voltage matches the indicated voltage of the LED soft neon before connecting to power. 6. Check the Positive and Negative Electrode before connecting. 7. Check the jacket are well protect the wire inside before installation 8. Always pre-warm the product for at least 30 min before bending and shaping. 9. Do not connect LED soft neon to power when it is tightly coiled in roll. 10. In cold winter season, please first place the product in an indoor environment with a temperature between 30 to 40 degree Celsius for over 2 hours, then start to uncoil the product. 11. Do not connect LED neon to power when the connecting and installation is not completed. 12. Make sure all connecting places and both ends are tightly sealed before applying the product for outdoor use. 13. Always bend the open ends of the product and cut the extra wires after splicing the LED neon. 14. Do not put the product into water or other liquids. Do not drop, hit or over bend LED neon when it is connected to power. 15. Do not hammer LED soft neon with heavy objects during installation. 16. Don t Pull the neon flex directly from the Roll. 17. Don t Pull the Neon Flex from the ground up to house. 18. Forbidden to Throw the LED Neon Flex from House down to floor. 19. Forbidden to hurt the insulating course at any time. 20. Forbidden to bend or Twist or Drop the body of Led Neon Light, The diameter of circle must be short 10cm.