GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori

Similar documents
GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2P05. Main. Device short name. Device application

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV2ME. Main. Device short name. Device application

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

GV2ME. Main. Device short name. Device application

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

A V 50Hz / V 60Hz

AS09..S 3-pole Contactors - Spring Terminals

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Datasheet - SRB-E-201ST

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

TeSys circuit-breakers

Type: DILM25 10(24V50HZ) Article No.:

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Safety dialogue solutions

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Type: DILM12 10(24VDC) Article No.:

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Circuit-Breakers for Motor Protection Series 8523/8

Magnecraft Power Relays

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Datasheet - SRB301LC 24VAC/DC

Ordering details. Approval. Classification

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Series CT7N Bimetallic Overload Relays

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

02/11/2015

TeSys contactors LC1-D09pp (5) LC1-D12pp (5) 0.325

llen-bradley 194R-HM4-NFPA3

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Manual Motor Starter Specifcations

Bulletin 190 IEC Modular Starter System

Modular pulse operated latching relay 16 A

Minicontactorrelay,2NO/2NC,DCoperated

High performance circuit breakers

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

LED control gear Compact fixed output

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

DMX and 4000 air circuit breakers from 800 to 4000 A

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

16 A and 25 A power contactors with or without handle

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Magnetic and Hydraulic-Magnetic Circuit Breaker

LED Driver Compact dimming

LED Driver Compact fixed output

OT 100/ /700 P5

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

LED Driver Compact fixed output

ALLEN BRADLEY TIMING RELAY

EXPlora. Introduction

LED Driver Linear / area fixed output

Product Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)

Feed-through terminal, 2.5 mm², Screw connection, Wemid, dark beige, TS 35

Capacitors and banks 50 Hz 0 400/415 V network voltage

Feed-through terminal, 4 mm², Screw connection, Wemid, dark beige, TS 35

Power Circuit of a UL508A Panel. Typical UL489 Application

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Interface Relays and Optocouplers Product group picture

Catalogue numbers. PowerPact Multistandard. H-Frame, J-Frame unit-mount circuit breaker F-2. H-Frame, J-Frame circuit breaker accessories F-3

Roof-mounted Blue e+ cooling unit Integration solution VX25

T5, T8, TC-L. PC T5 PRO lp W V 50/60/0 Hz, HO. Electronic ballasts Linear lamps T5, T8 and compact lamps TC-L

POWER FACTOR CORRECTION

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

Kuhnke Technical Data. Contact Details

DIN Power Module - Phase Adaptive

Process transmitter RMA422

Variable speed drives Altivar Process Three-phase supply voltage: V 50/60 Hz Wall-mounting drives

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Figure 1: Device components

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

Transcription:

Podatkovni list proizvoda Karakteristike GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori Glavno Range Product name Device short name Product or component type Device application Trip unit technology TeSys TeSys GV3 GV3P Circuit breaker Motor Thermal-magnetic Komplementarno Poles description Network type Utilisation category AC-3 conforming to IEC 60947-4-1 Category A conforming to IEC 60947-2 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode Operating position Motor power kw 3P AC Clipped on 35 mm symmetrical DIN rail Screwed on panel (with 3 x M4 screws) Any position 22 kw at 500 V AC 50/60 Hz 37 kwat 690 V AC 50/60 Hz 18.5 kwat 400/415 V AC 50/60 Hz Breaking capacity 50 ka Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 ka Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 50 ka Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 6 ka Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 12 ka Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Control type [In] rated current Trip unit rating Magnetic tripping current Rotary knob 40 A 30...40 A 560 A [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ith] conventional free air thermal current 40 A conforming to IEC 60947-4-1 [Uimp] rated impulse withstand voltage 6 kv conforming to IEC 60947-2 Power dissipation per pole Mechanical durability Electrical durability Operating rate 8 W 50000 cycles 50000 cyclesfor AC-3 at 440 V In 25 cyc/h Rated duty Continuous conforming to IEC 60947-4-1 Connections - terminals Direct terminal link EverLink BTR screw connectors 2 cable(s) 1...25 mm² solid EverLink BTR screw connectors 2 cable(s) 1...25 mm² flexible without cable end EverLink BTR screw connectors 2 cable(s) 1...25 mm² flexible with cable end Informacije dane u ovoj dokumentaciji sadrže opće opise i/ili tehničke karakteristike o performansama ovdje sadržanih proizvoda. Ova dokumentacija nije namijenjena kao zamjena za niti bi se trebala koristiti za određivanje prikladnosti ili pouzdanosti predmetnih proizvoda za konkretne korisničke primjene. Svaki takav korisnik ili integrator dužan je provesti odgovarajuću i potpunu analizu rizika, procjenu i ispitivanje proizvoda u odnosu na odgovarajuću specifičnu primjenu ili uporabu istog. Niti društvo Schneider Electric Industries SAS niti bilo koje od njegovih povezanih poduzeća ili podružnica neće preuzeti obvezu ili snositi odgovornost za pogrešnu upotrebu ovdje sadržanih informacija. 1 / 6

Tightening torque 5 N.m on EverLink BTR screw connectors for cable 25 mm² 8 N.m on EverLink BTR screw connectors for cable 35 mm² Suitability for isolation Yes conforming to IEC 60947-1 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Height Width Depth Product weight 111 mm 55 mm 136 mm 0.96 kg Okolina standards EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-4-1 UL 508 type E CSA C22.2 No 14-05 type E product certifications protective treatment ATEX BV CCC CSA DNV GL LROS (pending) RINA UL EAC IP degree of protection IP20 conforming to IEC 60529 IK degree of protection TH IK09 ambient air temperature for operation -20...60 C ambient air temperature for storage -40...80 C fire resistance 960 C conforming to IEC 60695-2-1 operating altitude 3000 m Offer Sustainability Green Premium product Compliant - since 0501 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Available Need no specific recycling operations Green Premium product Compliant - since 0501 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Available Need no specific recycling operations Contractual warranty Warranty period 18 months Thermal-Magnetic Tripping Curves Average Operating Times at 20 C Related to Multiples of the Setting Current 2 / 6

1a 1b 2a 2b 3 poles from cold state (Ir minimum): GV3P 3 poles from cold state (Ir maximum): GV3P 3 poles from hot state (Ir minimum): GV3P 3 poles from hot state (Ir maximum): GV3P Current Limitation on Short-Circuit (3-Phase 400/415 V) Dynamic Stress I peak = f (prospective Isc) at 1.05 Ue = 435 V 3 / 6

1 Maximum peak current 2 70-80 A (GV3P80), 62-73 A (GV3P73) 3 48-65 A (GV3P65) 4 37-50 A (GV3P50) 5 30-40 A (GV3P40) 6 23-32 A (GV3P32) 7 17-25 A (GV3P25) 8 12-18 A (GV3P18) 9 9-13 A (GV3P13) Maximum Thermal Limit on Short-Circuit Thermal Limit in ka 2 s in the Magnetic Operating Zone Sum of I 2 dt = f (prospective Isc) at 1.05 Ue = 435 V 4 / 6

1 70-80 (GV3P80) - 62-73 (GV3P73) 2 48-65 A (GV3P65) 3 37-50 A (GV3P50) 4 30-40 A (GV3P40) 5 23-32 A (GV3P32) 6 17-25 A (GV3P25) 7 12-18 A (GV3P18) 8 9-13 A (GV3P13) GVl3L, GV3P Dimensions (1) Blocks GVAN, GVAD and GVAM11. (2) Blocks GV3AU and GV3AS. X1 = Electrical clearance (ISC max) 40 mm for Ue 500 V, 50 mm for Ue 690 V NOTE: Leave a space of 9 mm between 2 circuit breakers: either an empty space or side-mounting add-on contact blocks. Side by side mounting is possible up to 40 C. Mounting on Rail AM1 DE200 or AM1 ED201 5 / 6

Panel Mounting, using M4 Screws Mounting on Pre-Slotted Plate AM1 PA GV3P 6 / 6