100G MMF 20m & 100m Link Model Comparison. John Petrilla: Avago Technologies March 2013

100G CWDM Link Model for DM DFB Lasers. John Petrilla: Avago Technologies May 2013

10GBASE-LRM Interoperability & Technical Feasibility Report

Module 11 : Link Design

Recommended Changes to Optical PMD Proposal

100G SR4 Link Model Update & TDP. John Petrilla: Avago Technologies January 2013

SMF Ad Hoc report. Pete Anslow, Ciena, SMF Ad Hoc Chair. IEEE P802.3bm, Geneva, September 2012

EVLA Fiber Selection Critical Design Review

100GBASE-SR4 Extinction Ratio Requirement. John Petrilla: Avago Technologies September 2013

10Gbps SFP+ Optical Transceiver, 10km Reach

40G SWDM4 MSA Technical Specifications Optical Specifications

10Gbps 10km Range 1310nm SFP+ Optical Transceiver

200GBASE-DR4: A Baseline Proposal for the 200G 500m Objective. Brian Welch (Luxtera)

10Gbps 10km Range SFP+ Optical Transceiver

40GBASE-ER4 optical budget

WWDM Transceiver Update and 1310 nm eye-safety

SNS-XFP-10GD-LR 10 Gbps Multi-Rate XFP Transceivers OC192/STM-64, 10GE or 10G FC 1310nm, Single-Mode 10Km, with Digital Diagnostics.

40G SWDM4 MSA Technical Specifications Optical Specifications

100G-FR and 100G-LR Technical Specifications

Ordering information. 40Gb/s QSFP+ ER4 Optical Transceiver Product Specification. Features

F M1SDI 1 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485. User Manual

64G Fibre Channel strawman update. 6 th Dec 2016, rv1 Jonathan King, Finisar

OC-48/STM-16 Bi-directional SFP Transceiver (40km) RBT25SI2

400G-FR4 Technical Specification

SFP-10G-LR (10G BASE-LR SFP+) Datasheet

The receiver section uses an integrated InGaAs detector preamplifier (IDP) mounted in an optical header and a limiting postamplifier

100G PSM4 & RS(528, 514, 7, 10) FEC. John Petrilla: Avago Technologies September 2012

EMPOWERFIBER 10Gbps 2km SFP+ Optical Transceiver EPP C

2.5 Gb/s Transponder with Mux/Demux (1310 and 1550 nm) 54TR Series

PRE-QSFP-LR4L 100G QSFP 28 Dual Range Optical Transceiver, 10km. Product Features: General Product Description:

SFCxxB16GExD SFP Dual Fibre CWDM ITU CWDM / 16dB / Gigabit Ethernet

POLARIZED FIBER OPTIC SOURCE

Product Specification XFP 10G LR 20km LC Optical Transceiver

FX-1310-F10 10Gbps XFP Optical Transceiver, 10km Reach

SFCxxB24GExD SFP Dual Fibre CWDM CWDM / 24dB / Gigabit Ethernet

Reducing input dynamic range of SOA-preamplifier for 100G-EPON upstream

Features: Compliance: Applications: Warranty: QSFP-40G-LR4-GT 40GBASE-LR4 QSFP+ SMF Module Cisco Compatible

SPCxxB10100D SFP+ Dual Fiber CWDM CWDM / 10dB / 10 Gigabit Ethernet

WaveReady WRT Gbps Extended-Reach DWDM Tunable Transponder with XFP Client Interface

Comparison of options for 40 Gb/s PMD for 10 km duplex SMF and recommendations

PV Series 850 nm VCSELs. Rise/ Fall Time Max. (nsec) 850nm GaAlAs VCSEL 1.8V, *indicates internal monitor photodiode)

3G-SDI Extender via Single Mode Fiber LC Simplex Connector Extends 3G-SDI Link Up To 20 Kilo Meters

Hardware Specifications

Optical Communications Mainframe - Laser Transmitter Module

Features: Compliance: Applications: Warranty: 49Y7928-GT QSFP+ 40G BASE-SR Transceiver IBM Compatible

OC-48/STM-16 SFP Transceiver (SR) RSP25SS1

Updated Considerations on 400Gb/s Ethernet SMF PMDs

MTS/T-BERD 8000 Platform

10Gb/s SFP+ Optical Transceiver Module 10GBASE-LR/LW

FIBRE CHANNEL CONSORTIUM

MTS/T-BERD 8000 Platform Optical Spectrum Analyzer Modules

10Gb/s SFP+ ER 1550nm Cooled EML with TEC, PIN Receiver 40km transmission distance

Single Fiber SFP Series

FiberLink 3350 Series

100GBASE-FR2, -LR2 Baseline Proposal

6ch LC duplex QSFP Receiver ROSA (4ch x 6Gbps) + μ-bosa (2.5Gbps) (2km) FVQ2-4R1B-SM2

Fiber Optic Testing. The FOA Reference for Fiber Optics Fiber Optic Testing. Rev. 1/31/17 Page 1 of 12

Cost Effective High Split Ratios for EPON. Hal Roberts, Mike Rude, Jeff Solum July, 2001

IQORXD Dual-Channel Multimode Fibre Optic Receiver for SDI

Technical Feasibility of Single Wavelength 400GbE 2km &10km application

10Gb/s XFP Optical Transceiver Module

T A S A 2 N B 1 F A H

100GBASE-DR2: A Baseline Proposal for the 100G 500m Two Lane Objective. Brian Welch (Luxtera)

Specification. Small Form Factor Pluggable Transceiver (MSA) LC Receptacle SFP+ 12 Gigabit SDI TIM-A1CB1-F11

FiberLink 3500 Series Transceivers

Fiber Type Core/Cladding (um) Rise/ Fall Time Max. (nsec) 850nm GaAlAs VCSEL 1.8V, *indicates internal monitor photodiode)

MX/HD-SDI-3G. Transmit HD-SDI-3G signals over Fiber

XFP 10G 850nm 300M SR SLXF-1085-SR

50 Gb/s per lane MMF baseline proposals. P802.3cd, Whistler, BC 21 st May 2016 Jonathan King, Finisar Jonathan Ingham, FIT

We will look first at the cable, and then the transceivers (which act as both transmitter and receiver on each end of the fiber cable).

OTLT / OTLR 3000 Manual. L-Band Fiber Optic Link MHz INSTRUCTION MANUAL

IQOTXD Dual-Channel Multimode Fibre Optic Transmitter for SDI

GbE SFP CWDM Transceiver (120km) RCP12SVX

Dual Fiber SFP Series

Long Reach, Client-Side SFP, Multi-Rate, Multi-Protocol, CWDM, 3R Transponder WaveReady Transponder 740 LR CWDM

ECT5484. Fiber Optic Digital Video, Audio & Data Multiplexer/Demultiplexer. Single Fiber Operation. Specifications

XFP Bi-Directional 10G 20Km 1270/1330nmTx / 1330/1270nmRx SLXFB-XXXX-20

XFP-1020-WA/B 10Gbps XFP Bi-Directional Transceiver, 20km Reach 1270/1330nm TX / 1330/1270 nm RX

An Effort to Create Multi-vender Environment for 100 Mb/s P2P optical Ethernet Access in Japan

PONA 3000 Series Erbium Doped Fiber Amplifier

10G BiDi XFP 10km Optical Transceiver GBX-xxxx192-LRC

50 Gb/s per lane MMF objectives. IEEE 50G & NGOATH Study Group January 2016, Atlanta, GA Jonathan King, Finisar

An Approach To 25GbE SMF 10km Specification IEEE Plenary (Macau) Kohichi Tamura

Intel Ethernet SFP+ Optics

500 m SMF Objective Baseline Proposal

LASERS. Fabry Perot (FP) Distributed Feedback (DFB) Vertical Cavity Surface Emitting Laser (VCSEL)

10G- XFP- LR- AO. 10Gbs XFP Transceiver

1623A/B O-Band DWDM DFB Laser Module

CWDM GBIC. 1.25Gbps GBIC Optical Transceiver, 80km Reach

1 Gang-sized Multi-format video to Optical DVI Converter, MVDF DATA SHEET

INTERNATIONAL TELECOMMUNICATION UNION

WS G Gbps GBIC Optical Transceiver, 80km Reach

Systematic Tx Eye Mask Definition. John Petrilla, Avago Technologies March 2009

PONA 3000 Series Erbium Doped Fiber Amplifier

FTX-S1XG-S55L-040DI. XFP 10GBase-ER, 1550nm, single-mode, 40km

TP2 and TP3 Parameter Measurement Test Readiness

Proposal for 400GE Optical PMD for 2km SMF Objective based on 4 x 100G PAM4

Product Specification. RoHS-6 Compliant 10Gb/s 10km XFP Optical Transceiver FTLX1412M3BCL

Very Long Haul Multi-rate Gigabit Ethernet SFP CWDM Transceivers with Digital Diagnostics

SPDxx040100D SFP+ Dual Fibre DWDM 100GHz DWDM / 40 km / 10 Gigabit Ethernet

Transcription:

1310 nm serial Back Reflection Co-authors in support of this proposed change: Network Elements Raj Savara LightLogic Marc Verdiell GTRAN Robert Coenen Optovation Scott Bradshaw Optillion Fröjdh Krister

1310 nm serial Back Reflection Objective Objectives: Create low cost 1310 nm Serial links Create specifications which interoperate between vendors Specifications which allow multiple technologies Design a robust PMD link with low RIN and low jitter The history Fourth of the existing level 12 db spec stems from 1G links on 850nm MMF with simple FC connectors. These were immune to reflections and Fifth were level designed without pigtail fibers for the connectors. Pigtails with mating connectors are a requirement with SMF due to alignment tolerance of fiber Mated connectors (SC or FC/PC) required at 10G rates; an air gap connector is unacceptable

1310 nm serial Back Reflection Problem Reverse back reflection at the receiver Measures the optical power reflected back from the input of a Click receiver to edit Master text styles Two types of noise are created by optical back reflections Optical feedback into the laser results in increased Jitter and RIN (1G designs required an RIN 120 db 10G require 130 db) Interferometric noise is caused by the conversion of laser phase noise into Fourth intensity level noise by multiple reflections in the optical path See Effects Fifth of Phase-to-Intensity level Noise Conversion by Multiple Reflections on Gigabit-per-Second DFB Laser Transmission Systems by James Gimlett and Nim Cheung in Journal of Lightwave Technology Vol. 7 No. 6 June 1989 Both types of noise can create BER penalties and BER floors Addressed in Comments of serial PMD optical spec s Marc Verdiell 9/00

1310 nm serial Back Reflection Objective Click to 1.00E-05 edit Master text styles Bit Error Rate 1.00E-04 1.00E-06 1.00E-07 1.00E-08 1.00E-09 1.00E-10 1.00E-11 Unisolated DFB, 1.3um: BER vs Back Reflection, 50C, 10km T=50C, D=10km, R=-40dB T=50C, D=10km, R=-27dB T=50C, D=10km, R=-20dB T=50C, D=10km, R=-14dB 1.00E-12-18 -17-16 -15-14 -13-12 Received Power <dbm> Uncooled Unisolated DFB showing the effects of both types of reflective noise Graph from LightLogic 9/00

1310 nm serial Back Reflection Solutions for optical feedback noise Manufactures of transponders terminate receiver fiber minimizing reflected power Very cost effective to produce (< 1% of total transponder costs) Users will use standard fiber to connect to transponder. No special considerations required! Add a transmit optical isolator will fix optical feedback into the laser only Third level Costly alternative in comparison to terminating receiver fiber properly Add external isolator Fifth level for reduced jitter, will only address optical feedback into the laser Costly external component

1310 nm serial Back Reflection Solutions for Interferometric noise Interferometric noise can not be fixed with an isolator This will reduce the BER sensitivity on all levels of signals The only way to reduce Interferometric noise is to reduce all reflections Maintain the 26 db return loss of the entire link including all connectors, attenuators, or any other device in the optical link This is less severe than SONET, but should maintain a robust link GR 1377 requires 27 db at the receiver GR 1377 asks for 40 db for link reflections from connectors

1310 nm serial Back Reflection Conclusion 10 Gigabit Serial links have tight design margins due to higher bandwidth receivers than lower speed links. The resulting noise will reduce the usable power budget, reduce the link length, and increase the BER. If noise can be designed out by low cost techniques, a more robust link will result Change clause 52 to reflect a 26 db return loss out of the receiver for 1310 nm serial PMD Maintain the 26 db return loss of the entire link including all connectors, attenuators, Third or any level other device in the optical link In section 52.12.2.2 link return loss is specified at 26 db per connector. Motion: Move to change clause 52, table 52-9 Return Loss specification to 26 db (min) Motion: Add to clause 52, table 52-10 Return Loss of any device in the optical link to 26 db (min)