Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Similar documents
Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Circuit-Breakers for Motor Protection Series 8523/8

Process Transmitter RMA 422

Process transmitter RMA422

Pendant Light Fitting IEC Series 6470/2

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

Explosion Proof Audible Signal db(a) Series YA60

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

Inductive sensor BI1.5-EG08K-Y1

Advantys STB DATA SHEET. Advantys STB Output Module. Description. Features

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Inductive sensor NI3-EG08K-Y1-H1341

RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Inductive sensor NI10-M18-Y1X-H1141

Capacitance Level Measurement Electronic insert FEC 12

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

8 Installation Equipment

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

RMA42. Technical Information

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Inductive sensor With analog output BI15-M30-LI-EXI

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

DMP 331i / DMP 333i LMP 331 i

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

Technical Information RIA45

02/11/2015

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

Fibre Optic Modem ODW-611

ACT20X Series for hazardous area applications Section A

Assembly. Front view. LEDs. Parametrization interface. Power Bus

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

Pendant Light Fittings Series 6050

Explosion Proof Audible Signal db(a) Series YA60

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

MB 204/MB 204-Ex. Multi-Barrier for PROFIBUS PA and FOUNDATION Fieldbus 10/ EN

A V 50Hz / V 60Hz

Fibre Optic Modem ODW-622

Flow Measurement SITRANS F M

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

MPCE Monitoring, Machine Test Signal. Guard Mode, Remote Reset. Eact Channel Select and Floating Blanking. Adjustable mounting brackets

High performance circuit breakers

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Flow Measurement SITRANS F M

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

7 Lighting Technology

General Specifications

3.3. Ex-Escape sign luminaires. Ex-Lite Metal version with LED technology for Zone 1 and Zone 21 / NEC applications

General Specifications

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

LD OEM/LD PDS/LD PeCo

Series CT7N Bimetallic Overload Relays

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

E6CP-A. An Absolute Encoder at About the Same Price as an Incremental Encoder. Ideal for robot limit signals. Low-cost Encoder with Diameter of 50 mm

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

DMP 331Pi. Precision. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Minicontactorrelay,2NO/2NC,DCoperated

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

SITRANS F M. Transmitter MAG 5000/6000 4/33

SERIES x5. Nickel-plated brass Connection 1) PUR cable type 1 Degree of protection. IP 67 Mounting. Embeddable Max. switching frequency

Guide for installers. METTLER TOLEDO MultiRange Explosion proof weighing system with IND226x weighing terminal.

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

ODW-621. RS-232 Point-to-point applications

EVENT INPUT/OUTPUT MODULE [PUME]

Multiple Band Outdoor Block Up- and Downconverters

2 WIRE - LOOP POWERED TRANSMITTER FOR PT100 AND NI100 PROBES

PMG. Vibration Energy Harvesters

Operating instructions

Fibre optic router for TP/FT-10 LRW-112PP

LONWORKS Fibre Optic Router

Absolute Encoders Multiturn

ALLEN BRADLEY TIMING RELAY

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

TFRN Industrial RTD temperature sensor. CombiTemp TM

SITOP power supply. Technical data, April SITOP Power Supply. Answers for industry.

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Generator protection relay

Transcription:

> 8 channels for 2-wire HART transmitters > Inputs for Ex nl, Ex na and Nonincendive > Galvanic separation between inputs and system > Open-circuit and short-circuit monitoring for each field circuit > Module can be replaced in > operation (hot swap) www.stahl.de 05678E00 The Analog Input Module HART is used for the connection and supply of up to 8 x 2-wire HART transmitters with 0... 20 ma or 4... 20 ma signals. Each input is individually monitored for open and short circuits. Inputs and power supplies are short-circuit proof and energy limited. The interface of the Analog Input Module with the internal data bus of the BusRail has integrated redundancy. The integrated HART multiplexer allows bidirectional HART communication between HART field devices and the automation and engineering system. Analog transmitters (non-hart) can also be operated. ATEX NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Ex interface x x Ex interface x x Ex interface x x x Installation in x x Installation in x x Installation in x x x WebCode 9461C Remote I/O /1

Selection Table Version Description Order number Weight kg Analog Input Module HART Note 8 channels for 2-wire HART transmitters 9461/15-08-12 0.241 Please order terminal separately - see Accessories Explosion Protection Europe (ATEX) Gas and dust Certifications and certificates Certificates Ship approval Safety data Maximum values for Max. voltage U o Max. voltage U i Max. current I o Max. current I i Max. power P o Max. power P i Cable parameters (ATEX) (for inductive or capacitive circuits) Max. connectable capacitance C o IIC IIB KEMA 06 ATEX 0291 X E II 3 (2) GD Ex na [nl] [ib] IIC T4 ATEX, India (PESO), Canada (CSA), Kazakhstan (GOST K), Serbia (SRPS), USA (FM), Belarus (operating authorisation) ABS, BV, ClassNK, DNV, GL, LR, RS 23.8 V 32 V 36 ma any 567 mw any 94 nf 0.88 mf Max. connectable inductance L o IIC 2 mh IIB 20 mh Max. internal capacity 2.5 nf C i Max. internal 0 inductance L i Further information see respective certificate and operating instructions Further parameters Installation in Zone 2, Div. 2 Further information see respective certificate and operating instructions Ex n inputs Number of channels Signal Signal range Minimum signal Maximum signal Supply voltage 8 (for 2-wire transmitter with / without HART) 0.. 20 ma, 4.. 20 ma + HART (adjustable parameters for each channel) 0 ma 23.5 ma 16.0 V at 20 ma for 2-wire transmitters /2 Remote I/O

Signal transmission Maximum short-circuit current Galvanic separation between power supply and system components between two input / output modules between inputs and system components Resolution in the range 4... 20 ma Maximum delay from input to internal bus, 0... 90 % of signal span Note: For HART operation, the time setting "medium" or 50 Hz, 60 Hz is recommended 35 ma Filter time constant (adjustable parameters) small medium 50 Hz, 60 Hz 12.75 bit 12.75 bit 12.75 bit 32 ms 120 ms 840 ms The inputs and outputs of an I/O module have a common negative conductor. Accuracy of measurement Note All values in % of the signal span, at 23 C Measurement Filter time constant (adjustable parameters) deviation small medium 50 Hz, 60 Hz Maximum measurement 0.075 % 0.05 % 0.05 % deviation Ambient temperature 0.1 % / 10 K influence Settings Open-circuit and ON, OFF (for each channel) short-circuit monitoring Value to fieldbus 10 %, 0 %, 100 % of the signal, alarm code, hold last value during open circuit, short circuit Diagnostics Retrievable Manufacturer, type, version, serial number parameters Module faults Internal primary bus faults Internal redundant bus faults No response Module does not correspond to configuration Hardware fault Signal errors for each channel Open circuit < 2.4 / < 3.6 ma (adjustable parameters, 4... 20 ma) Short circuit > 23.5 / > 22.8 / > 21 ma (adjustable parameters, 0/4... 20 ma) Measuring range Over range / under range Operator interface Operation LED green "RUN" Fault LED red "ERR" Auxiliary power Maximum power 6 W consumption Maximum power 3.6 W dissipation Remote I/O /3

Electrical connection Ex n field signals Connection diagram Plug-in terminals 16-pole with catch, 2.5 mm 2, screw or spring type X1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 4... 20 ma HART 0... 7 HART Ambient conditions Ambient temperature -20... +65 C Storage temperature -40... +70 C Maximum relative 95 % (no condensation) humidity Sinusoidal vibration (IEC EN 60068-2-6) Semi-sinusoidal shock (IEC EN 60068-2-27) Electromagnetic compatibility Mechanical data Module enclosure Fire resistance (UL 94) Degree of protection (IEC 60529) Modules Connections 1 g in frequency range between 10... 500 Hz 2 g in frequency range 45... 100 Hz 15 g (3 shocks per axis and direction) Tested according to the following standards and regulations: EN 61326-1 (1998) IEC 1000-4-1...6, NAMUR NE 21 Polyamide 6GF V2 IP30 IP20 Mounting / Installation Installation conditions Mounting type on 35 mm DIN rail NS 35/15 Mounting orientation horizontal and vertical Engineering notes Versions 946./.5 only for installation in Zone 2 or in safe area. Mixing of Zone 1 modules (946./.2) and Zone 2 modules (946./.5) on same BusRail is allowed. For separation between intrinsically safe and non-intrinsically safe circuits () 50 mm / 2 in), a partition (162740) is required. 05689E00 /4 Remote I/O

Accessories and Spare Parts Designation Figure Description Art. no. Plug-in terminal Screw connection, 2.5 mm 2 with screw lock, 16 pin, black, for connecting Ex nl/ex na field signals Labelling: 1... 16 162708 09898E00 Spring connection, 2.5 mm 2 with screw lock and test jacks, 16 pin, black, for connecting Ex nl/ex na field signals Labelling: 1... 16 162710 09899E00 Labelling strips "FB Addr... Mod No..." for pluggable terminal, sheet with 26 strips 162788 05869E00 Designation strips For BusRail, for 1 BusRail with 16 I/O modules 162793 05871E00 Warning sign "Clean modules only with a damp cloth." 162796 05872E00 Partition For assembly between intrinsically safe and non-intrinsically safe connectors of the I/O modules, in order to adhere to the required 50 mm distance 162740 02078E00 Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations 67 mm / 2.64 " 128 mm / 5.04 " 96,5 mm / 3.8 " 09879E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Remote I/O /5