ML785 PowerLab/8SP ADInstruments Data Acquisition Systems

Similar documents
PicoScope 2000 Series PC Oscilloscopes

ADINSTRUMENTS. making science easier. MA3300 Audio Monitor. Owner s Guide

PicoScope 4000 Series PC Oscilloscopes

R&S ZVA110 Vector Network Analyzer Specifications

DA-12R. User Manual. 1 to 2 RGBHV Distribution Amplifier. rev (English) COMM-TEC GmbH Siemensstr. 14 D Uhingen

PicoScope 2203, 2204, 2205 PC Oscilloscopes

PicoScope PC Oscilloscopes. User's Guide. ps2203.en r4 Copyright Pico Technology Limited. All rights reserved.


SP205+ DUAL 1x5 VIDEO & AUDIO DISTRIBUTION AMPLIFIER

PicoScope 3000 Series PC Oscilloscopes

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

PicoScope 6407 Digitizer

SignalTap Plus System Analyzer

AI-1204Z-PCI. Features. 10MSPS, 12-bit Analog Input Board for PCI AI-1204Z-PCI 1. Ver.1.04

Agilent 5345A Universal Counter, 500 MHz

Advanced Test Equipment Rentals ATEC (2832)

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

Data Pattern Generator

Vocia VI-6. Operation Manual

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

PicoScope 6407 Digitizer

PicoScope 3000 Series Automotive User guide

USB Phono Plus. Project Series USER S MANUAL. Audiophile Computer Interface

PicoScope 4000 Series PC Oscilloscopes

R&S ZN-Z151/-Z152/-Z153 Calibration Unit Specifications

Zigen ZIG-ADM. 4K UHD+ Dolby Digital & DTS Stereo Decoder. 4K 60 Hz 4:4:4 HDCP 2.2 ZigNet, Full Web Interface and System Diagnostics

R&S ZN-Z85 Switch Matrix Specifications

PicoScope 4000 Automotive PC Oscilloscopes

T L Audio. User Manual C1 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

32 Channel CPCI Board User Manual

R&S ZN-Z154 Calibration Unit Specifications

R&S RT-Zxx High-Voltage and Current Probes Specifications

The Art of Engineering

DT3162. Ideal Applications Machine Vision Medical Imaging/Diagnostics Scientific Imaging

DISTRIBUTION AMPLIFIER

MODEL NUMBER SRP-X700P

GFT Channel Digital Delay Generator

Synthesized Clock Generator

Product Brochure Version R&S ENV A Four-Line V-Network RFI voltage measurements at high currents

WaveNow USB Potentiostat / Galvanostat

R-1580A Microwave Downconverter. Product Brochure

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT /12/14 BIT 10 TO 65 MSPS DUAL ADC

AI-1616L-LPE. Features. High-precision Analog input board (Low Profile size) for PCI Express AI-1616L-LPE 1. Ver.1.02 Ver.1.01

Hegel HD20 High End D/A Converter

Fits the Leopard Family FREQ./RPM INPUT MODULE WITH 24 V EXC.

TA2000B-x GHz Fast Pulse / Timing Preamplifier User Manual

DT3130 Series for Machine Vision

FCPM-6000RC. Mini-Circuits P.O. Box , Brooklyn, NY (718)

Portable in vivo Recording System

AI-1664LAX-USB. Features. 100KSPS 16-bit Analog Input Unit for USB AI-1664LAX-USB 1. Ver.1.01

2 MHz Lock-In Amplifier

VGA CAT-5 1:8 Distribution S VGA CAT-5 Distribution R

Kramer Electronics, Ltd. USER MANUAL. Model: VS x1 Video Audio Switcher

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

Getting Started with. Front-end Signal Conditioners

USER GUIDE 3. For more information visit

R&S ZNBT Vector Network Analyzer Specifications

USB Smart Power Sensor

Product Brochure Version HZ-15_16_17_bro_en_ _v0100.indd 1

TR6102HD HDTV/DVD/COMPONENT VIDEO TO RGBHV TRANSCODER USER S GUIDE

Model 22.1 HDCD D/A Converter Instructions

QDA4-44 RF Amp/Combiner

DA IN 1-OUT LINE DRIVER WITH EQUALIZATION + AUDIO USER S GUIDE

AD16-64(LPCI)LA. Non-isolated high precision analog input board for Low Profile PCI AD16-64(LPCI)LA 1. Ver.1.01

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

VK-P10SE WARRANTY REGISTRATION FORM

R&S ZND Vector Network Analyzer Specifications

40 Gb/s PatternPro Programmable Pattern Generator PPG4001 Datasheet

Multi Room Audio Matrix Switcher

SWR Programmable Audio Switcher U S E R S M A N U A L

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

Kramer Electronics, Ltd. USER MANUAL. Model: VP-100. VGA/XGA to RGBHV Converter

KHT 1000C HV-Probe Calibrator. Instruction Manual

R&S ZN-Z103 Calibration Unit Specifications. Data Sheet V02.01

R&S ZV-Z81 Multiport Test Set, models.05/.09/.29 Specifications

R&S RT-ZVCxx Multi-Channel Power Probe Specifications

RS232 settings are internally definable via jumper blocks, to accommodate interfacing with a wide range of control products.

Kramer Electronics, Ltd. USER MANUAL. Model: VA-14. 4x1 Balanced Audio Mixer

SCALE & WEIGHT DISPLAYS

Kramer Electronics, Ltd. USER MANUAL. Model: VP-4x4. 4x4 VGA/XGA Audio Matrix Switcher

SK2002DA SIDEKICKER 1-IN, 2-OUT VGA-UXGA DISTRIBUTION AMPLIFIER CABLE USER S GUIDE DISTRIBUTION AMPLIFIERS

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

clipping; yellow LED lights when limiting action occurs. Input Section Features

Reference 150 LINEAR

BENESTON USER MANUAL AHD-ER03H. AHD to HDMI & VGA & AV Converter AHD-ER03H

RS232 settings are internally definable via jumper blocks, to accommodate interfacing with a wide range of control products.

NS-3 RF Noise Source Operation Manual

R&S ZVA-Zxx Millimeter-Wave Converters Specifications

Kramer Electronics, Ltd. USER MANUAL. Model: Power Amplifier

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT /12/14 BIT 10 TO 105 MSPS ADC

OPERATOR MANUAL OSD390 SERIES 4 CHANNEL VIDEO/AUDIO/DATA FIBER OPTIC TRANSMISSION SYSTEM

G.R.A.S. Sound & Vibration

WaveDriver 20 Potentiostat/Galvanostat System

QCA9-33 Active Combiner

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Telephony Training Systems

Model PR710 Series Signal conditioner operating guide

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

Programmable Power Supplies 188 W 384 W R&S HMP Series

Agilent N7744A 4-Channel Optical Multiport Power Meter N7745A 8-Channel Optical Multiport Power Meter. Fully compliant to LXI Class C specification

Transcription:

ML785 PowerLab/8SP ADInstruments Data Acquisition Systems Description The PowerLab/8SPis a data acquisition and analysis system for use in life science research. The system has 16 bit resolution (hardware and software supported), and is capable of recording at speeds of up to 200,000 samples per second. Communication with a PC is via USB or SCSI interface. It incorporates eight general purpose BNC analog inputs for measuring external signals. It also features a built-in analog output for stimulation or pulse generation (software controlled), and a trigger input. The PowerLab/8SPis compatible with instruments, signal conditioners, and transducers carried by ADInstruments, as well as many other established brands. Chart and Scope software is supplied with the hardware unit at the time of purchase. Computer System Compatibility PC Computers: Pentium level processor or faster with minimum 16 MB RAM (32MB for Windows NT) Windows 98 or later for USB interface Windows 95/Windows NT4 or later for SCSI interface* Macintosh Computers: PowerMac or faster & Mac OS8.5 or later for USB interface Macintosh computer with at least a 68020 CPU & Mac OS7.0 or later for SCSI interface* At least 4MB free RAM *Not all SCSI cards are suitable. Contact your local PowerLab distributor for more information. Chart & Scope Compatibility The following versions of Chart and Scope software are required to operate a PowerLab/8SP: WINDOWS l Chart v3.4.4 or later l Scope v3.6.5 or later MACINTOSH l Chart v3.6.1 or later l Scope v3.6.1 or later Applications The PowerLab/8SP data acquisition system is suitable for research in the fields of human and animal physiology, pharmacology, neurophysiology, biology, zoology, biochemistry, and biomedical engineering.

Specifications (As tested at the time of printing and are subject to change) Analog Inputs Number of input channels: 8 Input configuration: Single-ended Amplification range: 2 mv to 10 V full scale in 12 steps 10 V 5 V 2 V 1 V 0.5 V 0.2 V 0.1 V 50 mv 20 mv 10 mv 5 mv 2 mv Maximum input voltage: 15 V Input impedance: ~ 1 MW 47 pf @ DC Low-pass filtering: 20 khz to 1 Hz in 13 steps (software-selectable) AC coupling: DC or 0.16 Hz (software-selectable) Frequency response ( 3 db): 20 khz @ 10 V full scale, all ranges DC drift: Software corrected CMRR(differential): 96 db @ 50 Hz (typical) Input crosstalk: 110 db typical Input noise: < 2.4 V rms referred to input Sampling ADC resolution: 16 bit (312.5 V resolution at 10 V range) Linearity error: 1 LSB (from 0 to 70 C) Maximum sampling rates: 200 khz single channel 100 khz/channel for 2 channels 40 khz/channel for 3 or 4 channels 20 khz/channel for 5 to 8 channels Available sampling rates: 200 khz down to 0.003 Hz using Chart for Macintosh 200 khz down to 2 Hz using Scope 200 khz down to 1 Hz using Chart for Windows Sampling on USB rather than SCSI may limit the maximum sampling rates.

Output Amplifier Number of outputs: 2 Output configuration: Single channel (complementary) or 2 independent outputs Output resolution: 14 bits (0.6 mv resolution at 10 V range) Maximum output current: 12 ma Output impedance: 0.1 W typical Slew rate: 6 V/ s Settling time: 2 s (to 0.01%of FSRfor LSB change) Linearity error: 1 LSB (from 0 to 70 C) Output range: 200 mv to 10 V full scale in six steps 10 V 5 V 2 V 1 V 500 mv 200 mv External Trigger Trigger threshold: Hysteresis: Input load: Maximum input voltage: Minimum pulse width: 3.3 V 0.4 V >0.2 V 1.2 kw 12 V 5 s Microprocessor and Data Communication CPU: 16 MHz 68340 RAM: 512 K Data communication: SCSI (up to 4 megabytes/s, maximum, dependent on computer) USB (up to 500 kilobytes/s, maximum, dependent on setup) Expansion Ports I 2 C expansion port: Digital output: Digital input: Power and control bus for Front-end units. Supports up to 16 Front-ends but limited to PowerLab's free connectors. Interface communications rate of up to 10,000 bits/s. 8 independent lines, TTL output level (50 ma maximum load per line; 250 ma maximum total load) 8 independent lines, TTL input level, threshold 2.2 V Physical Configuration Dimensions (w x h x d): 300 x 60 x 300 mm (11.8" x 2.4" x 11.8") Weight: 4.8 kg (10 lb 8 oz) Operating voltage: 220-240 V or 110-120 V (internally set) Nominal power needs: 25 VA (no Front-ends or Pods attached) Maximum power needs: 50 VA (full complement of Front-ends and Pods)

WARRANTY: ADInstruments PowerLab Systems, Front-end and Pod Signal Conditioners are warranted against defects in materials and workmanship for a period of 3 years from the date of purchase. Transducers are covered by a 12 month warranty. Third party products are covered by the manufacturer's warranty. Warranties are void if the product has been damaged due to negligence. Consumables and electrodes are not covered by a warranty. All questions regarding service and warranty should be directed to your nearest PowerLab authorized distributor or one of the offices listed below. PowerLab/4SP Diagrams PowerLab/8 ADInstruments SP Output 1 Input 1 Input 2 Input 3 Input 4 Power Status Trigger Output 2 Input 5 Input 6 Input 7 Input 8 Front panel Not intended for human connection unless connections marked appropriately SCSI ID Digital Output No user-serviceable parts inside. Refer servicing to qualified service personnel. 2 I C Output Digital Input OFF Serial No: ON Termination Made by ADInstruments Pty Ltd, Castle Hill, Australia Do not obstruct fan outlet Rated Voltage: 220-250 V A.C. 50/60 Hz 30 VA Fuse Rating: 400 ma - 250 V (Slow Blow) Back panel Ordering Information ML785 PowerLab/8SP Includes: 1 PowerLab/8SP 8-Channel Data Acquisition System 1 Chart & Scope Software Installer CD 1 Cable Kit including Power Cord, BNC to BNC test cable, USB Cable (SCSI cable optional, contact your local distributor for compatibility information) 1 Getting Started with PowerLab Manual 1 Finger Pulse Transducer PowerLab and MacLab are registered trademarks of ADInstruments Pty Ltd. All other trademarks are the property of their respective owners. TT1/01 U-ML785-OG-003 ADInstruments Pty Ltd ISO 9001 Certified www.adinstruments.com Reg. No. 1053 Nor th Am erica Europe Japan Asia Inter national Tel+ 1 (970) 257 1584 Tel+ 44 (0) 1865 891 623 Tel+ 81 (3) 5820 7556 Tel+ 86 (21) 5830 5639 Tel+ 61 (2) 9899 5455 Fax+ 1 (970) 257 1583 Fax+ 44 (0) 1865 890 800 Fax+ 81 (3) 3861 7022 Fax+ 86 (21) 5830 5640 Fax+ 61 (2) 9899 5847 info@adinstruments.com info@adi-europe.com info@adijapan.co.jp info@adinstruments.com.cn info@adi.com.au