REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

Similar documents
REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

LM - 79 Reporting. Laboratory Information. Date of test report July 31 st, Product Information

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK Project No. G Date: October 29, 2010 REPORT NO CRT-001 TEST OF ONE LED DESK LAMP

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Test Report. Report Number: L15159 Date: Jan 6, Issued by: Dialight Optics Laboratory 1501 Route 34 South, Farmingdale, NJ 07727

Bartco Lighting 5761 Research Drive, Huntington Beach, CA

Fixture is tested with no special conditions. No seasoning was performed in accordance with IESNA LM-79. PS-AC02 CD-SN03-S2 MT-SC01-S2 2MR97 SPR-3000

Osram Sylvania 200 Ballardvale Street Wilmington, Mass

Number Eight Lighting Company 526 Portal Street, Cotati, CA 94931

Revolution Lighting Technologies (RVLT) 2280 Ward Ave. Docks 5&6, Simi Valley, CA 93065

IESNA LM79: 2008 Photometric Test Report

ZipTwo LED - Zipper board with Diffuse Batwing Lens, High Output. IES File Performance Summary

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

NVLAP LAB CODE LM Test Report. For. LIGHT EFFICIENT DESIGN (Brand Name:N/A) 188 S. Northwest Highway Cary, IL

Number Eight Lighting Company 803/K2-HI-25-XX/DIM /FS-P-1-WH

Cree Engineering Services Testing Laboratory (CESTL) Photometric Testing and Evaluation Report

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For LED PANEL LIGHTING CO.,LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For CE INNOVATIONS LTD. (Brand Name: IRICO) 911 Denison St Markham, ON L3R 3K4 Canada

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Fuel Pump Canopy Luminaires

PHONE: (303) FAX: (970) WEBSITE:

Photometric Test Report

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD

NVLAP LAB CODE LM Test Report. For. EiKO Global, LLC. (Brand Name: EiKO) W. 84th St, Shawnee, KS USA

Infinilux 5349 Zambrano St, Commerce, CA Electrical and Photometric tests as required by the IESNA test standards.

Report of Test LLIA A-R01*

LED Floodlight RoHS. Model: inner box: L273*W240*H165mm master carton: L549*W485*H175mm 4PCS

Photometric Test Report

NVLAP LAB CODE:

NVLAP LAB CODE:

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

Product testing and evaluation to IES LM-79-08

Report of Test LLIA

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE 24V LED Tape Light DI-24V-BL35-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE 24V LED Tape Light DI-24V-BL28-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV50-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV24-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. FLUID VIEW 24V LED Tape Light DI-24V-FV20-90**

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. INFINILINE X 120V LED Light DI-120V-INFX60

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. INFINILINE X 120V LED Light DI-120V-INFX27

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-24V-BLBSC1-30-W***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-12-BLBSC2-50-W***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE BASICS LED Tape Light - DI-24-BLBSC2-30-W***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU DI-24V-ES30-BK 3000K BLACK.

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. BLAZE Basics 100 LED Tape Light - DI-24V-BLBSC1-63-***

LightLab I N T E R N A T I O N A L

LightLab I N T E R N A T I O N A L

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. Blaze Basics 200 LED Tapelight DI-12V-BLBSC2-27-***

LM-79 Test Report. Relevant Standards IES LM IES TM CIE Product SKU. Blaze Basics 200 LED Tapelight DI-12V-BLBSC2-50-***

PHONE: (303) FAX: (970) WEBSITE:

IESNA LM-79: Measurement and Test Report for Venture Lighting International Aurora Road, Suite A, Solon, OH 44139,United states

American National Standard

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC W 84th St, Shawnee, KS LED120WPT50KMOG-G6

IEC Standard for Luminaires Part 1: General Requirements and Tests, IEC Edition 8, Issued May The

Evaluating and Specifying LED Lighting

Technical Report No Dated

Vaya Cove, Color. Data sheet. Philips Lighting Rev Burlington Woods Drive Burlington, MA 01803

Guidelines for Specification of LED Lighting Products 2010

TEST REPORT NO.: CRT-081 RENDERED TO: Hubbell Premise Wiring 14 Lord s Hill Road Stonington, CT

Draft Technical Requirements Version 4.3. October 20, 2017

PRODUCT FAMILY DATASHEET LEDVANCE DOWNLIGHT LED DALI

LINEAR DOWNLIGHT - PENDANT DIRECT

Transcription:

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 Project No. G102959372 Date: March 17, 2017 REPORT NO. 102959372CRT-001 TEST OF ONE LINEAR LED FIXTURE MODEL NO. K81400 F 10 44 W3 N N LED MODEL NO. OSRAM DURIS E5 RENDERED TO: ELECTRIX LLC 45 SPRING STREET NEW HAVEN, CT 06519 TESTS: Electrical and Photometric tests as required to the IESNA test standard. STATEMENT OF LIMITATION: This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. AUTHORIZATION The testing performed was authorized by signed quote number QU-00769823. STANDARDS USED: IESNA LM-79-2008: Electrical and Photometric Measurements of Solid State Lighting ANSI NEMA ANSLG C78.377: 2015: Specifications of the Chromaticity of Solid State Lighting Products DESCRIPTION OF SAMPLE: The client submitted one production sample of model number K81400 F 10 44 W3 N N. The sample was received by Intertek on March 13, 2017 in undamaged condition and one sample was tested as received. The sample designation was CRT1703131037-001. DATE OF TESTS: March 15, 2017 through March 17, 2017. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Report No. 102959372CRT-001 1 of 8 Date: March 17, 2017

SUMMARY: MODEL NO. K81400 F 10 44 W3 N N DESCRIPTION: LINEAR LED FIXTURE Criteria Light Output (Lumens) Total Power (W) Lumen Efficacy (Lm/W) Power Factor ( ) Criteria Current ATHD (%) Correlated Color Temp. (CCT-K) Color Rendering Index (CRI - Ra) CRI - R9 DUV ( ) Chromaticity Coordinate (x) Chromaticity Coordinate (y) Chromaticity Coordinate (u') Chromaticity Coordinate (v') Integrating Sphere Goniophotometer 4201 4241 44.23 44.32 95.00 95.70 0.996 0.997 Results 7.42 3147 84.4 16.1 0.002 0.425 0.396 0.246 0.517 EQUIPMENT LIST Equipment Used LSI High Speed Mirror Goniometer Elgar AC Power Supply Sorenson DC Power Supply Yokogawa Power Analyzer Omega Thermometer M-D Building Products Digital Level NIST Luminous Intensity Standard Source NIST Luminous Intensity Standard Source NIST Luminous Intensity Standard Source NIST Luminous Flux Standard Source Elgar AC Power Supply Sorenson DC Power Supply Yokogawa Power Analyzer Fluke Thermometer Fluke Multimeter 3M Integrating Sphere Spectrometer System Fisher Scientific Stopwatch Secondary Spectral Intensity Standard Source Secondary Luminous Flux Standard Source Secondary Luminous Flux Standard Source Secondary Luminous Flux Standard Source Model No. Control No. 6440 --- CW1251 --- XG 150-10 --- WT210 E464 DPi8-C24 M263 Smart Tool L112 NBS10322 N1427 NBS10332 N1435 NBS10265 N1437 NBS10428 N1424 CW1251 --- XFR 150-8 --- WT1600 E473 53 II N1324 87V D589 CDS 1100 --- 130471471 N1404 BS5186 RF5186 BS3616 -- BS4116 -- 6836 -- Last Cal. Cal. Due 02/28/17 03/28/17 05/02/16 05/02/17 05/02/16 05/02/17 04/08/16 04/08/17 01/09/17 01/09/19 01/09/17 01/09/19 01/09/17 01/09/19 01/11/17 01/11/19 05/10/16 05/10/17 04/07/16 04/07/17 05/25/16 05/25/17 03/13/17 04/13/17 12/29/16 12/19/17 01/28/17 01/28/18 01/28/17 01/28/18 01/28/17 01/28/18 01/28/17 01/28/18 Report No. 102959372CRT-001 2 of 8 Date: March 17, 2017

TEST METHODS: Seasoning in Sample Orientation LED Products No seasoning was performed in accordance with IESNA LM-79. Photometric and Electrical Measurements Integrating Sphere Method A Labsphere Model CDS 1100 CCD Array Spectroradiometer and two meter or ten foot sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to stabilize for at least thirty minutes before measurements were made. Stabilization procedures to LM-79 were followed. Electrical measurements including voltage, current, and power were measured using a power analyzer. The calibration of the sphere photometer-spectroradiometer system is traceable to the National Institute of Standards and Technology. Photometric and Electrical measurements Distribution Method A LSI Type C High Speed Model 6440 Mirror Goniometer was used to measure the intensity (candelas) at each angle of distribution for the SSL sample. Ambient temperature was measured equal to the height of the sample mounted on the goniometer equipment. The SSL sample was operated on the client provided driver at rated input volts in its designated orientation. The SSL sample was allowed to stabilize for at least thirty minutes before measurements were made. Stabilization procedures to LM-79 were followed. Electrical measurements including voltage, current, and power were measured using a power analyzer. Report No. 102959372CRT-001 3 of 8 Date: March 17, 2017

RESULTS: Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) Distribution Method Intertek Control No. CRT1703131037-001 Base Orientation Base Up Voltage (VAC) 120.08 Current (ma) 370.3 Power (W) 44.32 Power Factor ( ) 0.997 Light Lumen Output Efficacy (Lumens) (lm/w) 4241 95.70 Intensity (Candlepower) Summary at 25 C - Candelas Angle 0 22.5 45 67.5 90 0 1271 1271 1271 1271 1271 5 10 1323 1405 1326 1396 1319 1359 1295 1301 1277 1250 15 1499 1472 1394 1289 1208 20 1619 1567 1428 1262 1146 25 1783 1690 1467 1220 1067 30 35 2013 2444 1870 2181 1506 1572 1167 1097 981 873 40 45 3206 3445 2818 3458 1701 2055 1010 908 753 626 50 1758 2315 2706 801 499 55 516 809 2343 739 385 60 198 304 1219 719 289 65 106 140 566 606 212 70 76 84 254 394 152 75 52 54 116 213 104 80 35 35 51 104 63 85 25 24 29 43 26 90 0 0 0 0 0 Report No. 102959372CRT-001 4 of 8 Date: March 17, 2017

RESULTS: Illumination Plots Illuminance - Cone of Light Mounting Height: 10ft Isoillumination Plot Zonal Lumen Summary and Percentages at 25 C Zonal Lumens and Percentages at 25 C Zone Lumens % Luminaire Zone Lumens % Luminaire 0-30 1044.7 24.6 0-10 121.0 2.9 0-40 1832.3 43.2 10-20 355.3 8.4 0-60 3609.2 85.1 20-30 568.4 13.4 60-90 630.9 14.9 30-40 787.5 18.6 0-90 4240.1 100.0 40-50 1036.6 24.4 90-180 0.4 0.0 50-60 740.4 17.5 0-180 4240.5 100.0 60-70 396.3 9.3 70-80 185.4 4.4 80-90 49.2 1.2 90-100 0.4 0.0 Report No. 102959372CRT-001 5 of 8 Date: March 17, 2017

RESULTS: Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) Sphere Method Intertek Control No. Base Orientation Voltage (VAC) Current (ma) Power (W) Power Factor ( ) Current ATHD (%) CRT1703131037-001 Base Up 120.02 369.9 44.23 0.996 7.42 277.0 165.2 44.37 0.970 14.63 Light Output Lumen Efficacy Correlated Color CRI CRI DUV (Lumens) (lm/w) Temperature - CCT (K) -Ra -R9 ( ) 4201 95.00 3147 84.4 16.1 0.002 CIE 31 Chromaticity Coordinate (x) 0.425 CIE 31 Chromaticity Coordinate (y) 0.396 CIE 76 Chromaticity CIE 76 Chromaticity Coordinate (u') Coordinate (v') 0.246 0.517 ANSI C78.377 SSL Chromaticity (2015 Version) y 0.460 0.440 0.420 0.400 0.380 0.360 0.340 6500K 5700K 5000K ANSI ANSLG C78.377-2015 LED QUADRANGLES -7 STEP 4500K 4000K 3500K 3000K 2700K 2500K 2200K 0.320 0.300 0.290 0.310 0.330 0.350 0.370 0.390 0.410 0.430 0.450 0.470 0.490 0.510 0.530 x Report No. 102959372CRT-001 6 of 8 Date: March 17, 2017

RESULTS: Spectral Distribution Over Visible Wavelengths nm mw/nm nm mw/nm nm mw/nm nm mw/nm 350 0.668 460 30.869 570 59.018 680 21.838 355 0.694 465 25.703 575 62.377 685 19.021 360 0.673 470 21.436 580 65.516 690 16.513 365 0.657 475 17.710 585 68.499 695 14.238 370 0.538 480 16.597 590 70.903 700 12.356 375 0.591 485 17.476 595 72.669 705 10.636 380 0.542 490 19.418 600 73.951 710 9.189 385 0.508 495 22.399 605 74.072 715 7.866 390 0.562 500 25.861 610 73.525 720 6.758 395 0.559 505 29.234 615 72.373 725 5.783 400 0.567 510 32.076 620 69.734 730 4.973 405 0.725 515 34.676 625 66.716 735 4.293 410 1.117 520 36.831 630 62.939 740 3.683 415 1.859 525 38.820 635 58.908 745 3.190 420 3.264 530 40.678 640 54.367 750 2.735 425 5.496 535 42.506 645 49.877 755 2.405 430 9.046 540 44.372 650 45.141 760 2.074 435 14.391 545 46.043 655 40.594 765 1.788 440 23.230 550 48.267 660 36.278 770 1.521 445 34.074 555 50.386 665 32.276 775 1.356 450 41.426 560 53.089 670 28.473 780 1.160 455 38.782 565 55.900 675 24.976 Spectral Data Over Visible Wavelengths (mw/nm) 80.000 70.000 60.000 50.000 40.000 30.000 20.000 10.000 0.000 350 400 450 500 550 600 650 700 750 800 Nanometers Report No. 102959372CRT-001 7 of 8 Date: March 17, 2017

PRODUCT PICTURE: CONCLUSION The results tabulated in this report are representative of the actual test samples submitted for this report only. The data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not determined in this report. In Charge Of Tests: Report Reviewed By: Melanie Brittain Associate Engineer Lighting Division Jeffrey Davis Engineering Supervisor Lighting Division Attachments: IES File - CRT1703131037-001 Report No. 102959372CRT-001 8 of 8 Date: March 17, 2017