GV2ME. Main. Device short name. Device application

Similar documents
GV2ME. Main. Device short name. Device application

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

GV2P05. Main. Device short name. Device application

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

A V 50Hz / V 60Hz

TeSys circuit-breakers

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

AS09..S 3-pole Contactors - Spring Terminals

Datasheet - SRB301LC 24VAC/DC

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Series CT7N Bimetallic Overload Relays

Datasheet - SRB-E-201ST

Ordering details. Approval. Classification

Type: DILM25 10(24V50HZ) Article No.:

Type: DILM12 10(24VDC) Article No.:

Safety dialogue solutions

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Circuit-Breakers for Motor Protection Series 8523/8

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Magnecraft Power Relays

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Bulletin 190 IEC Modular Starter System

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

TeSys contactors LC1-D09pp (5) LC1-D12pp (5) 0.325

02/11/2015

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

Modular pulse operated latching relay 16 A

Minicontactorrelay,2NO/2NC,DCoperated

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

I r A Protection against direct contact Finger and back-of-hand proof to VDE 0106 part 100

Manual Motor Starter Specifcations

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

High performance circuit breakers

Power Circuit of a UL508A Panel. Typical UL489 Application

llen-bradley 194R-HM4-NFPA3

16 A and 25 A power contactors with or without handle

Magnetic and Hydraulic-Magnetic Circuit Breaker

Data Sheet Definite Purpose Contactors Ex9CK Series

LED control gear Compact fixed output

Kuhnke Technical Data. Contact Details

DMX and 4000 air circuit breakers from 800 to 4000 A

LED Driver Compact dimming

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Variable speed drives Altivar Process Three-phase supply voltage: V 50/60 Hz Wall-mounting drives

EMC Solutions Noise filtering

Operating instructions

LED Driver Compact fixed output

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Product Information. Circuit Breaker BZM1(16 to 125 A) Circuit Breaker BZM2 (125 to 250A) Circuit Breaker BZM3 (250 to 400A)

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

POWER FACTOR CORRECTION

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

LED Driver Compact fixed output

Capacitors and banks 50 Hz 0 400/415 V network voltage

Feed-through terminal, 2.5 mm², Screw connection, Wemid, dark beige, TS 35

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

Feed-through terminal, 4 mm², Screw connection, Wemid, dark beige, TS 35

LED Driver Linear / area fixed output

OPTOTRONIC Intelligent

8 Installation Equipment

OT 100/ /700 P5

Interface Relays and Optocouplers Product group picture

ALLEN BRADLEY TIMING RELAY

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Nessie Coils for VDH and VDHT valves

4/2 Introduction. 4/4 5SV RCCBs. 4/10 5SM3 RCCBs. 4/13 SIQUENCE 5SM3/5SU1 universal current-sensitive RCCBs, type B and type B+

Transcription:

Product datasheet Characteristics GV2ME10 Main Range Product name Device short name Product or component type Device application Trip unit technology TeSys TeSys GV2 GV2ME Circuit breaker Motor Thermal-magnetic Complementary Poles description Network type Utilisation category AC-3 conforming to IEC 60947-4-1 Category A conforming to IEC 60947-2 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode Operating position Motor power kw 3P AC Clipped on 35 mm symmetrical DIN rail Screwed on panel (with adaptor plate) Any position 3 kw at 500 V AC 50/60 Hz 4 kw at 690 V AC 50/60 Hz 2.2 kw at 400/415 V AC 50/60 Hz Breaking capacity 3 ka Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 50 ka Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 ka Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 ka Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 ka Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 75 %at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Control type [In] rated current Trip unit rating Magnetic tripping current Push-button 6.3 A 4...6.3 A System Voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ith] conventional free air thermal current 6.3 A conforming to IEC 60947-4-1 78 A [Uimp] rated impulse withstand voltage 6 kv conforming to IEC 60947-2 Power dissipation per pole Mechanical durability Electrical durability Operating rate 2.5 W 100000 cycles 100000 cycles AC-3 at 440 V 25 cyc/h Rated duty Continuous conforming to IEC 60947-4-1 Connections - terminals Tightening torque Screw clamp terminals 2 cable(s) 1...6 mm² solid Screw clamp terminals 2 cable(s) 1.5...6 mm² flexible without cable end Screw clamp terminals 2 cable(s) 1...4 mm² flexible with cable end 1.7 N.m on screw clamp terminals Suitability for isolation Yes conforming to IEC 60947-1 Phase failure sensitivity Yes conforming to IEC 60947-4-1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. 1 / 7

Height Width Depth Product weight 3.5 in (89 mm) 1.77 in (45 mm) 3.08 in (78.2 mm) 0.57 lb(us) (0.26 kg) Environment standards EN 60204 IEC 60947-1 IEC 60947-2 IEC 60947-4-1 NF C 63-120 NF C 63-650 NF C 79-130 UL 508 VDE 0113 VDE 0660 CSA C22.2 product certifications protective treatment ATEX BV CCC CEBEC CSA DNV EZU GL LROS (Lloyds register of shipping) RINA SETI TSE UL EAC IP degree of protection IP20 conforming to IEC 60529 IK degree of protection ambient air temperature for operation ambient air temperature for storage TH IK04-4...140 F (-20...60 C) -40...176 F (-40...80 C) fire resistance 1760 F (960 C) conforming to IEC 60695-2-1 operating altitude 6561.68 ft (2000 m) Offer Sustainability Green Premium product Compliant - since 0631 - Schneider Electric declaration of conformity Reference contains SVHC above the threshold - go to CaP for more details Available Need no specific recycling operations WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.p65warnings.ca.gov Green Premium product Compliant - since 0631 - Schneider Electric declaration of conformity Reference contains SVHC above the threshold Available Need no specific recycling operations WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months Thermal-Magnetic Tripping Curves for GV2ME and GV2P Average Operating Times at 20 C Related to Multiples of the Setting Current 2 / 7

1 3 poles from cold state 2 2 poles from cold state 3 3 poles from hot state Current Limitation on Short-Circuit for GV2ME and GV2P (3-Phase 400/415 V)) Dynamic Stress I peak = f (prospective Isc) at 1.05 Ue = 435 V 3 / 7

1 Maximum peak current 2 24-32 A 3 20-25 A 4 17-23 A 5 13-18 A 6 9-14 A 7 6-10 A 8 4-6.3 A 9 2.5-4 A 10 1.6-2.5 A 11 1-1.6 A 12 Limit of rated ultimate breaking capacity on short-circuit of GV2ME (14, 18, 23, and 25 A ratings). Thermal Limit on Short-Circuit for GV2ME Thermal Limit in ka 2 s in the Magnetic Operating Zone Sum of I 2 dt = f (prospective Isc) at 1.05 Ue = 435 V 4 / 7

1 24-32 A 2 20-25 A 3 17-23 A 4 13-18 A 5 9-14 A 6 6-10 A 7 4-6.3 A 8 2.5-4 A 9 1.6-2.5 A 10 1-1.6 A Dimension GV2ME (1) Maximum X1 Electrical clearance = 40 mm for Ue 690 V b GV2ME 89 GV2ME 3 101 Mounting 5 / 7

GV2ME On 35 mm rail c = 78.5 on AM1 DP200 (35 x 7.5) c = 86 on AM1 DE200, ED200 (35 x 15) On panel with adapter plate GV2AF02 On pre-slotted plate AM1 PA On rails DZ5 MB201 GV2AF01 Combination GV2ME + TeSys k contactor GV2AF3 Combination GV2ME + TeSys d contactor GV2ME + LC1D09 D18 LC1D25 and D32 b 176.4 186.8 c1 94.1 100.4 c 99.6 105.9 GV2AF4 + LAD311 Combination GV2ME + TeSys d contactor 6 / 7

GV2ME + LC1D09 D18 LC1D25 and D32 b 176.4 186.8 c1 103.1 136.4 c 135.6 141.9 d1 107 107 d 112.5 112.5 GV2ME + GV1L3 (Current Limiter) X1 = 10 mm for Ue = 230 V or 30 mm for 230 V < Ue 690 V GV2ME and GV2RT Connection of Undervoltage Trip for Dangerous Machines (Conforming to INRS) on GV2ME Only 7 / 7