The New X-Rite Standard for Graphic Arts

Similar documents
ColorBurst RIP Proofing System for GRACoL Coated #1 proofs

ColorBurst RIP Proofing System for SWOP Coated #3 proofs

Cie L*48.57 a* b* Covering the World. Solutions for paint and coatings color management

Cie L*55 a* b* Keeping Color in Fashion. Solutions for textile color consistency

Vertis Color Communicator ll SWOP Coated #3

Remote Director and NEC LCD3090WQXi on GRACoL Coated #1

IDEAlliance PROOFING CERTIFICATION & VERIFICATION PROGRAMS (Version 12) August 2007

semi-automated scanning

Accurate Colour Reproduction in Prepress

LaCie 321 LCD Monitor

Hardware Calibration LCD Monitors. ColorEdge Series. Color as it s meant to be

Color measurement and calibration of professional display devices

Remote Director. Apple 23 LCD Display. Collaborative Soft Proofing using the I. MANUFACTURER INTRODUCTION. SWOP Application Data Sheet

Remote Director. EIZO ColorEdge CG21. Collaborative Soft Proofing using the I. MANUFACTURER INTRODUCTION. SWOP Application Data Sheet

ColorEdge Color Calibration LCD Monitors

InkZoneLoop & InkZonePerfect. Pre Installation Check List

Achieve Accurate Critical Display Performance With Professional and Consumer Level Displays

ISO/IEC TR TECHNICAL REPORT

Illuminating the home theater experience.

LG Electronics Monitor Proofing System with LG W2420R Display and Adobe Acrobat 8 Professional for GRACoL Coated #1

Printing aims based on a shared neutral gray-scale

Color Reproduction Complex

ENGINEERING COMMITTEE Interface Practices Subcommittee SCTE STANDARD SCTE

Precise Digital Integration of Fast Analogue Signals using a 12-bit Oscilloscope

ICC Color Symposium. Soft Proofing Revisit and Reborn. Chris Bai Senior Color Expert BenQ. 22/10/2018 Hong Kong. Organizers

VP2780-4K. Best for CAD/CAM, photography, architecture and video editing.

Principles of LCD monitor colors

HIGH RESOLUTION LED-MODULES PERFECT VISUAL SOLUTIONS

Application Note. Using Hitch Standardization on a Series of Color Measuring Instruments AN

Overview of All Pixel Circuits for Active Matrix Organic Light Emitting Diode (AMOLED)

SpectraView Profiler 4.0

Visual Color Matching under Various Viewing Conditions

Understanding PQR, DMOS, and PSNR Measurements

DRAFT. Proposal to modify International Standard IEC

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

User Calibration Software. CM-S20w. Instruction Manual. Make sure to read this before use.

Will Widescreen (16:9) Work Over Cable? Ralph W. Brown

Sources of Error in Time Interval Measurements

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

For More Information Visit:

User Manual. When Colour is Critical

2 Types of films recommended for international exchange of television programmes

We bring quality to light. SNT 10 DC Power Supply

Quato Intelli Proof Series. A comprehensive overview of the key benefits

Module 11 : Link Design

specification MSE series MSE and MSE+ colorimeter

High-Definition, Standard-Definition Compatible Color Bar Signal

Troubleshooting EMI in Embedded Designs White Paper

INTERNATIONAL STANDARD

OpticalProducts. Illuminating Your Network. Testing the World s Networks

Processing. Electrical Engineering, Department. IIT Kanpur. NPTEL Online - IIT Kanpur

ColorBurst RIP Ver. 7.0 Linearization, Ink-Limit and Profile Creation Process on Windows Machines

Communication Theory and Engineering

The preferred display color temperature (Non-transparent vs. Transparent Display)

LCD and Plasma display technologies are promising solutions for large-format

Advanced Color Consistency

3M Graphics Warranties. Once we ve got you covered, you re covered. 3M Basic Product Warranty 3M Performance Guarantee 3M MCS Warranty

DISPLAY WEEK 2015 REVIEW AND METROLOGY ISSUE

Achieve Accurate Color-Critical Performance With Affordable Monitors

Agilent I 2 C Debugging

COSC3213W04 Exercise Set 2 - Solutions

Also highly recommended: Graphing Resources ( homepage.htm), particularly their Revising your Visuals section.

The Future of Control Room Visualiza on

The Extron MGP 464 is a powerful, highly effective tool for advanced A/V communications and presentations. It has the

Revolutionary AOI Technology, Unbelievable Speed World's Fastest and Most Accurate 3D SPI

Self-Test and Adaptation for Random Variations in Reliability

LED TEST. ATX Hardware GmbH West and Feasa Enterprises Limited a long-standing partnership. SPECIALIST FIXTURE SOLUTIONS

Classic. Best Practice QA Solutions for All Rotational Therapies & IMRT For International Use Only. Classic. RIT113 Technical Specifications

Showcasing Brilliant Photos with Superb High- Definition Clarity

Superior Digital Video Images through Multi-Dimensional Color Tables

VARIOUS DISPLAY TECHNOLOGIESS

LED Display Backlighting Monitor Applications using 6-lead MULTILED Application Note

What is the history and background of the auto cal feature?

PAK 5.9. Interacting with live data.

Using the new psychoacoustic tonality analyses Tonality (Hearing Model) 1

Teaching Plasma Nanotechnologies Based on Remote Access

R&S ZN-Z85 Switch Matrix Specifications

R&S FSW-K144 5G NR Measurement Application Specifications

Scalable self-aligned active matrix IGZO TFT backplane technology and its use in flexible semi-transparent image sensors. Albert van Breemen

Once we ve got you covered, you re covered.

Paper for Consideration by the Digital Information Portrayal Working Group (DIPWG) Comment about recommendation on S-52 Colour Calibration Procedure

PMCL300 Series TFT LCD Monitor 17-INCH, 19-INCH, OR 19-INCH WIDE, WITH MULTIMODE FUNCTIONALITY

Global Trade Medical Supplies

NCRA Standards for Video Depositions

SMPTE 292M EG-1 Color Bar Generation, RP 198 Pathological Generation, Grey Pattern Generation IP Core - AN4088

e2b calibration 521 Fifth Avenue Chardon, Ohio Phone: Fax: Certificate Of Calibration

May 2018 KSA9003A 2018 CAT. NO. K3256-A (ddc) Printed in Japan

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

A Statement of Position on Advanced Technologies IP HDR & 4K WHITE PAPER

Development of OLED Lighting Panel with World-class Practical Performance

INTERNATIONAL STANDARD

About... D 3 Technology TM.

Unrivaled Displays. Breakthrough Colors?

Murdoch redux. Colorimetry as Linear Algebra. Math of additive mixing. Approaching color mathematically. RGB colors add as vectors

ENGINEERING COMMITTEE

MODULE No. 14: Age of Documents

HDR & WIDE COLOR GAMUT

FIR Center Report. Development of Feedback Control Scheme for the Stabilization of Gyrotron Output Power

Case study WWAY station in a box

WQHD 2560 x 1440 Resolution 99% srgb color coverage and 87% AdobeRGB color coverage provide richer and more precise

Transcription:

The New X-Rite Standard for Graphic Arts (XRGA) Introduction Color is a fundamental factor in the creation of almost all products. In most industries, effective control and communication between designer, manufacturer and retailer are essential to obtaining high product quality and cost efficiency. However, methods for specifying and communicating color are often process-specific and the interpretation of color data across workflows can be ambiguous. This makes color consistency difficult to achieve, especially in cross-media color reproduction. In industries where color is mission-critical, the most accurate and reliable way to measure and control color is through the use of high quality spectrophotometers- or spectrodensitometers that objectively characterize the intrinsic value of color. We understand this intrinsic value to be unchanging, meaning that all measurements taken for the same color sample should, in theory, be the same. However, graphic arts professionals know this is generally not the case in practice. Why is that? Reasons behind measurement variance Every physical color sample has its own reflectance fingerprint, which is typically measured using a spectral measurement device. The sample s unique spectral response is measured by comparing the ratio of light reflected or transmitted from a surface as a function of wavelength, to that from a known reference standard. Many companies offer spectral instrumentation to accomplish this task, with the ability to perform spot, scanning, and inline (embedded) measurements. Over time, users often find themselves using measurement instruments from many different manufacturers for color control. They also use instruments with varied measurement functionality at different points in their workflow. This will often lead to a common and troublesome situation where measurements report slightly different results for the same sample. This can be especially problematic when databases are built using a particular instrument model that doesn t satisfactorily agree with results from other models used by a different department or site. The variance in color measurements ultimately results from the fact that each manufacturer uses slightly different physical calibration standards for their instruments. Systematic differences characterized in X-Rite study In 2006, the two leaders in the field of color science and technology, X-Rite and GretagMacbeth, merged to form the new X-Rite, Inc. The former X-Rite and the former GretagMacbeth each had, for historical reasons, different calibration standards for graphic arts instrumentation. Both companies maintained their standard over time to guarantee the compatibility of measurement data with their instruments for their customers. The continuity of standards was a benefit to each company s customer base, but instruments from each of the former companies exhibit systematic differences on a given sample. It is the goal of the new X-Rite that inter-model color agreement is optimized for advances in color science so that all of our customers regardless of their legacy affiliation - can enjoy high quality data exchange between sites that use different instrumentation. Figure 1: Left to Right: SpectroEye, i1pro, 530

X-Rite conducted a study designed to quantify the systematic differences between measurements obtained using instruments from both former companies, and to ultimately arrive at the definition of a new corporate X-Rite standard for its graphic arts instrumentation. We quantify the systematic differences under the term inter-model agreement, which is different from the inter-instrument agreement that is typically specified for each product. Popular models from each company were chosen for the study, and measurements were performed under typical working conditions on printed substrates. Measurements were performed on a typical media wedge (fig. 2) in No-Filter mode, referred to as M0 in ISO-13655. This is the most common filter setting used in graphic arts applications. The following instruments were used in this study: GretagMacbeth: i1pro, Spectrolino, SpectroEye; X-Rite: 530, 938, 939. Figure 2: Media Wedge Test samples: Substrates: Altona Test Suite gloss-coated, matt-coated, gloss-coated LWC, uncoated white, uncoated slightly yellowish (equals ISO paper types 1 to 5) Japan Color coated, uncoated, matt coated, art Digital Printing, High quality inkjet photo paper from Fuji Colors: UGRA/FOGRA Media Wedge (46 patches) Measurement procedures and conditions: All measurements were performed in accordance with ISO-13655 standards. All measurements were performed on the same black backing material. All tests were performed in an air-conditioned room with temperature monitoring and control (23 C +/- 1 C). Humidity was controlled at 65%. The media wedge was measured with each instrument, at an interval of 4 seconds between the measurements in No-Filter mode (M0). Data analysis: Colorimetric calculations were executed for D50 illuminant and the 2 standard observer functions. The colorimetric differences between two instrument types on every single patch of the media wedge were calculated using 1976 CIEL*a*b (de*ab) formulas. The mean and maximal 95% values of the colorimetric differences for all patches in an instrument-to-instrument comparison were calculated.

For the sake of brevity and clarity, we present data for one substrate type: high quality photo paper used for digital printing. Results were found to be almost independent of substrate type, so this is a minor abbreviation of the test results. Full results can be supplied upon request. The data shows very good agreement for each manufacturer-specific group, among former X-Rite instruments (530, 938 and 939), as well as among former GretagMacbeth instruments (i1pro, Spectrolino, SpectroEye). Inter-model agreement is not as good between former X-Rite and former GretagMacbeth instruments when considered together. The differences illustrate the consequence of using different calibration standards by each of the former companies. The differences between the two families of instruments are significant for graphic arts applications, and create difficulties for color data exchange between sites that may use instruments from each former company. 530 938 939 i1pro SpectroEye de*ab mean 95% mean 95% mean 95% mean 95% mean 95% 938 0.27 0.48 939 0.39 0.85 0.33 0.82 i1pro 0.90 2.70 0.92 2.40 0.96 2.44 SpectroEye 1.08 2.94 1.06 2.89 1.03 2.80 0.56 1.36 Spectrolino 0.91 2.47 0.88 2.36 0.83 2.14 0.47 1.01 0.37 0.83 Table 1: Results of Inter-Model Agreement with Legacy Calibration Standards The new X-Rite standard - XRGA The inter-model agreement study quantifies the systematic differences between former X-Rite and former GretagMacbeth calibration standards. With this knowledge, we have defined a new corporate X-Rite Standard for Graphic Arts (XRGA), which achieves the following goals: Incorporates improved methods for calibration Maintains traceability to the American National Institute of Standards and Technology (NIST) Best implementation with respect to existing standards Improves inter-model agreement for existing instruments Preserves good agreement among former X-Rite instruments and former GretagMacbeth instruments Provides a single standard for all future graphic arts instruments to be delivered by X-Rite X-Rite has developed a set of proprietary matrix transforms that enable measurements taken by either a former X-Rite or a former GretagMacbeth instrument to be easily expressed in the new corporate standard. Transformation of the previously displayed data (Table 1) demonstrates significant improvement provide when using XRGA. The improved results are illustrated in Table 2.

530 938 939 i1pro SpectroEye de*ab mean 95% mean 95% mean 95% mean 95% mean 95% 938 0.27 0.48 939 0.39 0.85 0.33 0.82 i1pro 0.49 1.03 0.50 1.11 0.51 1.23 SpectroEye 0.60 1.26 0.56 1.25 0.43 0.85 0.56 1.36 Spectrolino 0.56 1.17 0.55 1.28 0.44 0.95 0.47 1.01 0.37 0.83 Table 2: Inter-model agreement using the new X-Rite Standard (XRGA) Inter-model agreement conclusions Inter-model agreement is almost independent on the substrate type. Inter-model agreement between former X-Rite instruments (530, 938 and 939), as well as between former GretagMacbeth instruments (i1pro, Spectrolino, SpectroEye) is not changed with the new XRGA standard. The new XRGA standard provides good inter-model agreement among all X-Rite instruments. What this means to X-Rite customers For most of our products, the switch to XRGA results in very small differences in measurement values, so many customers will not need to make any changes. The table below shows the differences that can be expected for the instruments involved in this study: de*ab mean 95% 530 0.27 0.66 938 0.27 0.66 939 0.28 0.66 i1pro 0.60 1.61 SpectroEye 0.60 1.63 Spectrolino 0.60 1.63 Table 3: Differences Between Legacy Standards and the new X-Rite Standard (XRGA) (measurements performed on Digital Printing, High quality proof paper) Former X-Rite instruments are very near the new X-Rite Standard. For customers who experience larger differences after moving to the new standard, X-Rite will provide seamless means to move existing databases to the new XRGA standard. All customers will benefit from the use of the new XRGA standard: a. Significantly improved inter-model agreement b. Traceable to NIST c. Improved printing specification agreement d. Improved data exchange

All future graphic arts instruments delivered by X-Rite will also conform to XRGA. Since the introduction of XRGA, the existing legacy GretagMacbeth and X-Rite products have been switched over to the new XRGA standard. Tools are available to aid in the transition of legacy data where applicable and, in some cases, are included in many new versions of X-Rite software products, such as IFS, Color iqc, and X-RiteColor Master. All new X-Rite graphic arts products will conform to XRGA when introduced for sale. ColorPort, is a free software utility, that can be used to transform data to XRGA. ColorPort v2.x can be downloaded from the X-Rite website (http://www.xrite.com/product_overview.aspx?id=1336&action=support&softwareid=1105) and can be used to save data in either the XRGA standard or an instrument s native response. This allows you to immediately adopt the standard if you wish, or to do your own trials regarding the impact of this standard to your existing workflow. Instruments supported in ColorPort include: 530 938 939 SpectroEye SP62/64* i1pro i1io i1isis DTP20 (Pulse) DTP22 DTP41 DTP45 DTP70 Spectroscan *SP62/64, while supported by ColorPort, will not be transformed to XRGA as it pertains only to 0/45 and 45/0 instruments and not sphere illumination. Additional information and Frequently Asked Questions are posted on our website. To find out how the XRGA applies to you, and for any additional information please see: www.xrite.com/xrga. X-Rite World Headquarters Grand Rapids, Michigan USA (800) 248-9748 +1 616 803 2100 xrite.com 2012 X-Rite, Incorporated. All rights reserved. L7-462 (01/12)