BEAM DIAGNOSTICS IN THE CNAO INJECTION LINES COMMISSIONING

Similar documents
Linac 4 Instrumentation K.Hanke CERN

DIAGNOSTIC INSTRUMENTATION FOR MEDICAL ACCELERATOR FACILITIES

LHC Beam Instrumentation Further Discussion

III. Proton-therapytherapy. Rome SB - 3/5 1

Preparations for Installation, Testing and Commissioning based on Experience at CERN, SNS and Siemens

COMMISSIONING SCENARIOS FOR THE J-PARC ACCELERATOR COMPLEX

Beam Loss Detection for MPS at FRIB

EPJ Web of Conferences 95,

The PEFP 20-MeV Proton Linear Accelerator

BEAM DYNAMICS AND EXPERIMENT OF CPHS LINAC *

Hall-B Beamline Commissioning Plan for CLAS12

Mechanical aspects, FEA validation and geometry optimization

Upgrading LHC Luminosity

CHAPTER 4 OSCILLOSCOPES

Commissioning the TAMUTRAP RFQ cooler/buncher. E. Bennett, R. Burch, B. Fenker, M. Mehlman, D. Melconian, and P.D. Shidling

OPERATIONAL EXPERIENCE AT J-PARC

Particle Beam Production - A Synchrotron-Based System - Prof. Dr. Thomas Haberer Scientific-technical Director Heidelberg Iontherapy Center

HIGH POWER BEAM DUMP AND TARGET / ACCELERATOR INTERFACE PROCEDURES *

G. Pittá(*), S. Braccini TERA Foundation, Novara, Italy (*) Corresponding author.

PRESENT STATUS OF J-PARC

HD Review March 30, 2011 Franz Klein

The basic parameters of the pre-injector are listed in the Table below. 100 MeV

PEP II Design Outline

The Construction Status of CSNS Linac

The FAIR plinac RF Systems

INSTALLATION STATUS OF THE ELECTRON BEAM PROFILER FOR THE FERMILAB MAIN INJECTOR*

Design Studies For The LCLS 120 Hz RF Gun Injector

3B SCIENTIFIC PHYSICS

beam dump from P2 losses this morning

Durham Magneto Optics Ltd. NanoMOKE 3 Wafer Mapper. Specifications

2 Work Package and Work Unit descriptions. 2.8 WP8: RF Systems (R. Ruber, Uppsala)

Physics Requirements for the CXI Ion Time-of-Flight

Tutorial: Trak design of an electron injector for a coupled-cavity linear accelerator

New Filling Pattern for SLS-FEMTO

Proton Engineering Frontier Project

Design, Fabrication and Testing of Gun-Collector Test Module for 6 MW Peak, 24 kw Average Power, S-Band Klystron

CERN S PROTON SYNCHROTRON COMPLEX OPERATION TEAMS AND DIAGNOSTICS APPLICATIONS

PBS Products from Pyramid

Commissioning of Accelerators. Dr. Marc Munoz (with the help of R. Miyamoto, C. Plostinar and M. Eshraqi)

THE OPERATION EXPERIENCE AT KOMAC*

Advanced Photon Source - Upgrades and Improvements

Beam instrumentation at the 1-MW proton J-PARC RCS

Principles of Electrostatic Chucks 6 Rf Chuck Edge Design

FINAL DESIGN OF ILC RTML EXTRACTION LINE FOR SINGLE STAGE BUNCH COMPRESSOR

Lt DELTA USA, Inc

TWO BUNCHES WITH NS-SEPARATION WITH LCLS*

Periodic Seasonal Variation of Magnets Level of the STB ring

SPEAR 3: Operations Update and Impact of Top-Off Injection

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

Recent developments in cyclotrons for proton therapy at IBA

Commissioning of the ATLAS Transition Radiation Tracker (TRT)

4.9 BEAM BLANKING AND PULSING OPTIONS

Practical Application of the Phased-Array Technology with Paint-Brush Evaluation for Seamless-Tube Testing

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency

The Beam Test Facility at the SNS

PRACTICAL APPLICATION OF THE PHASED-ARRAY TECHNOLOGY WITH PAINT-BRUSH EVALUATION FOR SEAMLESS-TUBE TESTING

OPERATIONAL EXPERIENCE WITH CIRCULATING BEAM

PUBLICATION. Measurement setup at light source operational: Milestone M4.3

2008 JINST 3 S LHC Machine THE CERN LARGE HADRON COLLIDER: ACCELERATOR AND EXPERIMENTS. Lyndon Evans 1 and Philip Bryant (editors) 2

TECHNICAL SPECIFICATION Multi-beam S-band Klystron type BT267

Actuators IC 20, IC 30, IC 50

Progress of Beam Instrumentation in J-PARC Linac

Standard Operating Procedure of nanoir2-s

... A COMPUTER SYSTEM FOR MULTIPARAMETER PULSE HEIGHT ANALYSIS AND CONTROL*

COMMISSIONING AND FIRST RESULTS OF THE ELECTRON BEAM PROFILER IN THE MAIN INJECTOR AT FERMILAB*

The Cathode Ray Tube

Experimental Results of the Active Deflection of a Beam from a Kicker System

STATUS AND CONCEPTUAL DESIGN OF THE CONTROL SYSTEM FOR THE HEAVY ION THERAPY ACCELERATOR FACILITY HICAT

ANKA RF System - Upgrade Strategies

LINEAR ACTUATORS. Type S / SH 95, S / SH 80, S / SH 71, S / SH 56

Equipment Installation, Planning, Layout, organisation and updates

3B SCIENTIFIC PHYSICS

Electric Rotary Modules. Rotary Actuators

Digital BPMs and Orbit Feedback Systems

High QE Photocathodes lifetime and dark current investigation

THE NEW LASER FAMILY FOR FINE WELDING FROM FIBER LASERS TO PULSED YAG LASERS

DIRECT DRIVE ROTARY TABLES SRT SERIES

GENCOA Key Company Facts. GENCOA is a private limited company (Ltd) Founded 1995 by Dr Dermot Monaghan. Located in Liverpool, UK

Installation Operation Maintenance

FIRST SIMULTANEOUS TOP-UP OPERATION OF THREE DIFFERENT RINGS IN KEK INJECTOR LINAC

MultiMac SM. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

Design and Simulation of High Power RF Modulated Triode Electron Gun. A. Poursaleh

Linear flow control with actuator IFC

Mechanical Design of Recirculating Accelerator Experiments for Heavy-Ion Fusion

Test beam data analysis for the CMS CASTOR calorimeter at the LHC

14 GHz, 2.2 kw KLYSTRON GENERATOR GKP 22KP 14GHz WR62 3x400V

Industrial Diode Laser (IDL) System IDL Series

The Syscal family of resistivity meters. Designed for the surveys you do.

Screen investigations for low energetic electron beams at PITZ

Linear flow controls VFC Linear flow controls with actuator IFC

Experience with the Cornell ERL Injector SRF Cryomodule during High Beam Current Operation

CATHODE-RAY OSCILLOSCOPE (CRO)

DESIGN AND PERFORMANCE OF L-BAND AND S-BAND MULTI BEAM KLYSTRONS

DOSE DELIVERY SYSTEM OF THE VARIAN PROBEAM SYSTEM WITH CONTINUOUS BEAM

Color Ground 12T 16 A USER MANUAL 5 APPENDIX 5.1 TROUBLE SHOOTING 5.2 MAINTENANCE LED MODULE. Version 1.0 SITUATION CAUSE ACTION 5 APPENDIX

ABORT DIAGNOSTICS AND ANALYSIS DURING KEKB OPERATION

1. General principles for injection of beam into the LHC

MultiMac. Eddy Current Instrument for Encircling Coil, Sector and Rotary Probe Testing of Tube, Bar, & Wire

Recent APS Storage Ring Instrumentation Developments. Glenn Decker Advanced Photon Source Beam Diagnostics March 1, 2010

Challenges in Accelerator Beam Instrumentation

Transcription:

BEAM DIAGNOSTICS IN THE CNAO INJECTION LINES COMMISSIONING A. Parravicini, G. Balbinot, J. Bosser, E. Bressi, M. Caldara, L. Lanzavecchia, M. Pullia, M. Spairani, CNAO Foundation, Pavia, Italy C. Biscari, INFN/LNF, Frascati, Italy Abstract The Centro Nazionale di Adroterapia Oncologica (CNAO) [1] is the first Italian center for deep hadrontherapy, namely an innovative type of oncological radiotherapy using hadrons. The CNAO machine installation is in progress and alternates with lines commissioning [2] [3], started in the Summer 2008. The present paper reports about Beam Diagnostics (BD) choices, status and post-commissioning evaluation, as concerns the Low Energy Beam Transfer (LEBT) line monitors. upstream the Chopper, or downstream the Chopper but to be used when the Chopper is off. THE CNAO LEBT LINE The CNAO Machine The CNAO heart is made by a 25 m diameter synchrotron. One injection line, starting from one of the two available sources, brings the 8keV/u ion (C 4+ or H + 3 ) beams to the RFQ-IH, that accelerates particles to 7 MeV/u, which is the energy of the Medium Energy Beam Transfer (MEBT) line beam. At the beginning of the MEBT line, electrons are stripped out from Carbon or Hydrogen ions, that become C 6+ or protons, respectively. The MEBT line brings particles into the synchrotron, where C 6+ and protons can be accelerated up to 250 MeV/u and 400 MeV/u, respectively, according to the deepness of the tumour to be irradiated. Finally, particles are extracted towards one of the four extraction lines (3 horizontal and 1 vertical), that deliver the beam to one of the three treatment rooms (i.e., the central treatment room is equipped with horizontal and vertical beam lines). The LEBT Beam Diagnostics Layout The CNAO beam originates from one of the two ECR sources, both able to produce C 4+ or H + 3 ion beam. The beam produced by a source contains many ion species. Downstream each source, a 90 -dipole (also called spectrometer) allows to select particles with different Z/A ratio and thus to separate H + 3 and C 4+ beams from the other species. A switching dipole magnet merges the two source lines into one, which is bent by a 75 -dipole and, finally, enters the RFQ (Fig. 1). Ahead the RFQ, a Chopper magnet changes drastically the beam parameters: upstream the Chopper the beam is continuous; after the Chopper it is pulsed, with 50-100 us long batches, every about 2 seconds. BD monitors for a continuous or a chopped beam are significantly different. The present paper mainly focuses on the BD monitors designed for a continuous beam, namely installed Figure 1: LEBT line layout. Sketch of magnets and beam diagnostics monitors, from the sources to the test bench installed at the end of the LEBT line, during LEBT commissioning, in place of the RFQ. Legend: SLA= Slit monitor, FCA= Faraday Cup monitor, BWS= Wire Scanner, CFC= Chopper Faraday Cup monitor, GCT= AC- Current Transformer, PIA= Wires Harp, IC1= Chopper magnet. As concerns BD devices, vertical and horizontal wire scanners are used as profile and position monitors. Six Faraday cups and one Chopper Faraday cup measure beam intensity. Sets of four metallic plates, mounted on top, bottom, left and right tank ports, each one driven by a motor, altogether called slit monitor, are used either to suppress beam halo, if plates are positioned at beam border, or to select thin beam slices, in case one plate is positioned close to the opposite one, making a slit. This

last use allows both, phase space distribution measurements if beam profiles are measured behind the slit, and beam profile measurements at slit level, if beam intensity is measured downstream. As a rule of thumb, two profile monitors (each made of one vertical and one horizontal wire) are installed along each straight sector, at least, in order to permit the measurement of beam profile and barycentre position at the beginning and at the end of the sector, and to determine the trajectory angle, in the vertical and the horizontal plane. At the end of each straight sector, a beam current intensity monitor is usually installed. Slit monitors are installed before and after each spectrometer, and a little before the 75 -dipole. An additional full set of monitors (i.e., horizontal and vertical slit, horizontal and vertical wire scanner and one Faraday cup) was installed in the temporary test bench mounted at the end of the LEBT line, at commissioning time. In this case, a harp monitor, used for chopped beam profile measurements, is installed, too. A standardization strategy was adopted in order to make monitors production cheaper, their maintenance easier, and to improve more quickly the experience about hardware problems and monitors behaviour. As a consequence of this strategy, a 390 mm long tank was designed [4], able to house four slit plates, one vertical and one horizontal wire scanner and a Faraday cup. Five tanks of this type are mounted along the LEBT line and two others made the temporary test bench installed at the end of the line itself, at commissioning time. In the case longitudinal space is not a limitation, this tank was installed even if not all the monitors are required, closing down the unused tank ports with blind flanges. In few other cases, if not all the monitors are required and the available space was rather small, a shorter and dedicated tank was designed. BD MONITORS IN THE LEBT COMMISSIONING Wire Scanners Monitors A wire scanner monitor is usually made by one vertical and one horizontal Tungsten wire, with 0.1 mm diameter. Each wire is driven perpendicularly to beam direction, by a brushless motor up to 250 mm/s (100 mm/s, typically). Wire position is measured by means of a linear potentiometer, with about 20um accuracy. Wire scanners (Fig. 2) vacuum-side cables resulted very fragile and they often broke down, during the first period of commissioning. As soon as the problem appeared in all its seriousness, the design was revisited and the broken wires not only repaired, but also improved. Once all the wires have been reviewed, this kind of problem didn t occur any more. During commissioning, the wire scanner spatial resolution (0.1 mm, nominally) with respect to a fixedwires device (e.g., a multi-wires chamber) resolution was greatly appreciated. On the other hand, measurements stressed out the importance of a careful alignment of the wires with respect to the beam reference path, that could be improved at CNAO. Figure 2: Picture of the Wire Scanner monitor wire, mounted on its fork. Wire fork is screwed to the brushless motor shaft that drives the wire IN /OUT the beam path. The resolution obtained with the wire scanner was the key-element to allow emittance measurements (Fig. 3), within 150 mm only, namely by using slit and wire scanners housed in the same 390 mm long tank. Of course, a higher resolution in particles divergence measurement is reached behind the switching magnet, where slit (L1-017B-SLA, Fig. 1) and wire scanners (L1-022B-BWS, Fig. 1) are about 1 meter away from each other. Figure 3: Phase space distribution at the level of O1-023B-SLA monitor, for the vertical plane. The measurement is performed moving the vertical plates from -30 mm to +30 mm, with 1mm step, and keeping left and right plates at -5 mm and +25 mm, respectively, in order to select H 3 + peak and stop all the other species. By using statistical emittance definition, we derive the RMS Twiss parameters and emittance value at 1 sigma. The corresponding ellipse is draft on the plot with full line. The dashed line ellipse is a reference ellipse the user can fix.

Wire scanner heating was tested leaving the wire on the beam spot for a long time. It never exceeded the 300 C temperature, which is far below the Tungsten melting point (i.e., 900 C). On the other hand, if wire temperature changes, its resistance changes, too. Despite that, beam profile measurements are not affected, since the wire scanner amplifier is a trans-conductance amplifier, whose output current doesn t depend on the wire resistance. Wire scanner amplifier works from 1 na to 1 ma, with five different gains (i.e., 10^4 to 10^8 V/A). It has a 400 Hz bandwidth that fully covers the 50 Hz bandwidth of the expected physical phenomena. Faraday Cup Monitors Commissioning operations showed up the good quality of the Faraday cup (Fig. 4) CNAO-developed front end amplifier. It was designed in order to measure DC-beam current and to detect any ripples due to sources or power supplies, up to 15 khz. It allowed to measure satisfactorily the chopped beam pulse, consequently, making the detector very versatile. Faraday cup amplifier works from 100 na to 100 ma, with seven different gains (i.e., 10^2 to 10^8 V/A). to protect the insulators from Carbon ions and reduce the occurrence of this drawback. A water-cooling system was designed to avoid overheating of the Faraday cup monitors left on the beam path for a long time, upstream the spectrometers, before ions selection, where the expected beam current was more than 10mA (i.e., about 360 W full beam power). To be conservative, the same cooling system was installed on all the Faraday cups of the LEBT line. It warranted monitors safety even in case they are used as beam stopper for an infinite time. An additional monitor, belonging to the Faraday cup family is the Chopper Faraday Cup (CFC) (Fig. 5). It is installed just downstream the Chopper magnet. Figure 5: Chopper Faraday cup body, that is the vacuum chamber section just behind the Chopper magnet. Thin metallic tabs are machined on the body itself, in order to enhance heat evacuation by air-convection. Figure 4: Faraday cup monitor installed on its tank and looked at from a side port (beam should come from the left). One can recognize the Copper cup, from its typical colour. Two Stainless Steel rings are mounted in front of the cup: the repeller ring (on the left), and the guard ring (on the right). We could also appreciate the advantage of a large diameter (i.e., 135 mm) cup that can be used as beam stopper, as well, since it closes down the whole beam pipe section. Despite the large diameter, secondary emitted electrons are fully repelled when about -350 V are applied to the repeller ring. Repelling voltage can be set from 0 V to -1 kv. Faraday cup vacuum-side insulators presented some troubles due to the fact that ions are deposited on them, they become conductive. This accident more often occurred at the Faraday Cup monitors just behind the sources, where beam is larger and particles more scattered around the vacuum chamber. A shielding is under design It is an innovative monitor, developed at CNAO, and still under commissioning with beam. It is based on the Faraday cup principle, namely it aims to measure beam intensity by stopping the beam and measuring the collected charge. In fact, the cup stopping the beam to be measured is made by the 390 mm long vacuum chamber, installed just downstream the Chopper magnet and insulated from the rest of the LEBT beam pipe. A inner cylinder, opened on the side the beam is deviated towards by the Chopper, is grounded, while the cup can be polarized up to 1.25 kv, in order to capture secondary emitted electrons. Differently from the usual Faraday cup, the CFC can be retained not destructive, since it measures the beam deviated by the Chopper magnet against the vacuum chamber and doesn t intercept the beam entering the RFQ. Since the beam is deviated against the vacuum chamber by Chopper for 99.99% of the time, the CFC will allow a basically continuous beam current monitoring, without perturbing the beam delivered to the patients. No water cooling is foreseen for the CFC: air cooling is retained sufficient, for the current intensities expected at the LEBT end. On the other hand, heat evacuation is enhanced by thin metallic tabs, machined all around the vacuum chamber acting as the cup.

Slit Monitors Each one of the metallic plates (Fig. 6) used as halo suppressor or slit, is driven by a brushless motor up to 250 mm/s (100 mm/s, typically). Its position is measured by means of a potentiometer with about 20 um accuracy, like for the wire scanner. Care must be taken in manufacturing the plates with edge-angle borders, in order to avoid cutting the highdivergent particles: it was taken into account during plates design, but it was necessary increasing the angle, at commissioning time. current at the end of the LEBT line and warn the operator in case of significant changes, without intercepting the beam entering the RFQ. Figure 6: The four Copper plates, making one Slit monitor, installed on their tank. Left and Right plates are positioned at beam border; Top and Bottom plates are making a very thin slit at about tank center. Measurements (Fig. 7) with polarized (50 V) slit plates cancel the effect of the secondary electrons emitted by the plates hit by the beam, on the particles distribution, as seen by a wire scanner, downstream the slit plates. The effect is visible if the plates are grounded rather than polarized. Repelling voltage can be set from 0 V up to 1 kv. Slit plates are equipped with the same water cooling system used on the Faraday cup monitors. Watch-Dog Strategy After commissioning, when CNAO machine will treat patients for most of the time, measurements perturbing the beam shall be avoided. The opportunity of monitoring beam parameters, without interfering with the beam, guided BD team at the time of monitors choice. Wire scanners can be used in Watch-Dog mode, positioning a wire at beam spot border and measuring its current. If it suddenly increases or decreases, a warning is delivered to the user, since it could be due either to a beam transverse displacement or to a significant source current variation. Similarly, slit plates will be used during treatments as beam halo suppressor, positioning the four plates at beam spot border. Information about beam intensity without affecting the beam delivered to the patients is provided by the Chopper Faraday cup. As already discussed, it can monitor beam Figure 7: The two pictures show a horizontal beam profile, acquired with the O2-023D-BWS horizontal wire scanner, while upstream left and right slit plates (O2-023B-SLA) are placed at -5 mm and +5 mm, respectively. In the picture on the left, slit plates are grounded and we notice the profile baseline having a deformed shape, like a negative current is induced on the wire at beam peak sides. Secondary electrons produced by the beam impinging on plates border could be responsible for such a negative current. The effect disappears in the right picture, taken while slit plates are polarized at +50 V. Polarized slit plates re-capture their emitted secondary electrons and the wire doesn t detect a negative current at beam border, any more. CONCLUSIONS After some hardware wavers due to the innovative designs and the lack of pre-commissioning with beam, monitors installed in the CNAO LEBT line provided reliable and reproducible measurements. The LEBT line commissioning was surely slowed down by the fact that monitors user s interface debugging was still in progress. On the other hand, the choice of monitor types and their layout along the line resulted well

fulfilling operation needs, in order to reach source and LEBT commissioning goals within 15 weeks. Complicated mechanical designs were repaid by highperforming devices. The CNAO-developed electronics comprising high voltage polarization, pneumatic actuator and brushless motor control, and interlock systems management worked successfully. The most deserving aspect surely concerns signals amplification and delivery, since it worked perfectly over a wide dynamic range (6 decades) and bandwidth (DC to 15 khz for the Faraday cup and DC to 400 Hz for the wire scanner). REFERENCES [1] S.Rossi, Developments in proton and light-ion therapy, EPAC 2006. [2] E.Bressi et al, Status report on the Centro Nazionale di Adroterapia Oncologica (CNAO), PAC 2009. [3] A.Parravicini et al., Commissioning of the CNAO LEBT and sources, HIAT 2009. [4] J.Bosser et al, A compact and versatile diagnostic tool for CNAO injection line, EPAC 2008.