Mobility Pass. Mobility

Similar documents
ECS COMBINED CUT-OUT AND CT CHAMBER INSTALLATION

Connectors for mains connection IEC

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

NZQA unit standard version 3 Page 1 of 7. Demonstrate knowledge of telecommunications cable systems

Practical examples of unsafe (dangerous) electrical products under the scope of LVD

CLP s first 400kV XLPE cable application

Spectra Batten (Order code: LEDJ95)

Institutes of Technology: Frequently Asked Questions

Connectivity accessories by Nestor Cables

Original BMW Accessory. Installation Instructions.

Preventing Fieldbus Physical Layer Problems

Original BMW Accessories. Installation Instructions.

2002, Cisco Systems, Inc. All rights reserved.

Sample Test Project. District / Zonal Skill Competitions. Skill- Electrical Installation. Category: Construction and Building Technology

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Request for Quote E- Rate Eligible Services Scope of Work - Wireless LAN and Cabling for Access Points

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

Request for Quote E- Rate Eligible Services Scope of Work Network Infrastructure and Structured Cabling

9I273 01/10/2012 COU-03/0 AUTOMATIC CHANGEOVER UNIT TO BACK-UP AMPLIFIER

Nessie Coils for VDH and VDHT valves

SECTION COMMUNICATIONS HORIZONTAL CABLING

TVAC20000 User manual

Dragonfly Quad. User Manual V1.4. Order code: EQLED101

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

The Kent Range of Metering Products T131, T132, T133, T134 pulse units

Power Injector 1520 Series

HARTING Ethernet cabling cables and connectors, 4 wire

S Regulators. Supplement 1. Contents. Control Replacement Assembly Installation Instructions Supplement

Operating instructions

MIL-C CLASS L COMPATIBILITY ORDERING INFORMATION

BILOXI PUBLIC SCHOOL DISTRICT. Biloxi Junior High School

SECTION INTERCOMMUNICATIONS AND PROGRAM SYSTEMS

Invitation to Bid SCOREBOARD - WHH

Pendant Light Fitting IEC Series 6470/2

POWER MOLE SERIES DA GAO RGBT RADIX

Fusion 120 Zoom. User Manual. Order code: EQLED068

LED IP65 Slimline Par RGBWA +UV 7x12W

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Accessories. EasyPact and Vigi CVS100/160/ short LV long LV Steel connectors 1 x (1.5 to 95 mm²) ; y 160 A Set of 3 LV429242

SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM

VITALink Taped Splice Straight Through Crimp

Using DLP LightCrafter 4500 Triggers to Synchronize Cameras to Patterns

Inductive sensor With analog output BI15-M30-LI-EXI

SECTION MEDIUM VOLTAGE CABLE INSTALLATION. 1. Section Underground Ducts and Manholes.

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Contact Details. British Transport Police: (24 hours) Crimestoppers: In association with:

Inductive sensor NI3-EG08K-Y1-H1341

LED Spere Direct Control 30 ORDERCODE 41125

Drop Passives: Splitters, Couplers and Power Inserters

TERMINATIONS AND JOINTS FOR XLPE-INSULATED kv MEDIUM VOLTAGE CABLES

SBL Series Wireless Clock Installation Manual (V2) Table of Contents

Laying of cables and lines in electrical installations and data networks

ECONOMICAL 36 kv CABLE SYSTEM FOR THE BELGIAN NETWORK

technical data (according to IEC ) Degree of protection IP 67 Max. ripple content 15 % U B / 20 % U B (amplifier) No-load supply current

Amphenol. Amphenol-Tuchel Electronics GmbH. C 112 Series M12 - Connectors

Main Products. Cable Assemblies Wire Harnesses Raw Cables. Connectors

American National Standard for Electric Lamps Double-Capped Fluorescent Lamps Dimensional and Electrical Characteristics

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

45 mm : all channels. Output indicator Yellow LED System status indicator Light source Infrared (880 nm) Opening angle +/ 4 Emission angle +/ 5

RZ1-K BS EN XLPE LSZH Flexible Cable

Stratos Duo RGB. User Manual. Order code: EQLED371

LCB-320 LED COLORS 320X10MM DMX 16SEG

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

DMX LED light effect with 4 lenses

Model 1421 Distribution Amplifier

Introduction 1. Green status LED, controlled by output signal ST. Sounder, controlled by output signal Q6. Push switch on input D6

Tuesday 21 June 2016 Afternoon

Panel-mounting thermostats, type series EM

ECS INSTALLATION OF SERVICE WAYS AND CABLES (SCHNEIDER ELECTRIC)

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

Table of Contents. Read This First.2. Introduction by Jim Fosgate...3. Unpacking..4. Tubes and Tube shield Installation 5. Product Placement...

Local Control Network

SMART CINEMAHORIZONTAL. User Guide VPSP Projector side. model. Notice SmartCrystal Cinema MUV V1R0

Identification of LV Cables

RECOGNITION OF PRIOR LEARNING CANDIDATE APPLICATION FORM UEE30811 CERTIFICATE III IN ELECTROTECHNOLOGY - ELECTRICIAN

42 LCD Overhead Video Display Support Specifications Electricity required on the rear curtain wall

OPERATIONAL MANUAL EMZS CH Speaker Zone Selector. Version 1.6

LINK-RAY TM MODULATORS FOR CONSTANT- VOLTAGE. LinkRay Modulators 12 V / 24 V Constant-voltage Applications MODULATORS

Church Layout Small. Specifier Product Information

CHIEF BROADCAST ENGINEER

32 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall)

MODELS USIX-024 AND USIX-120 INSTRUCTION SHEET FOR FEDERAL SIGNAL UNISTAT STATUS INDICATOR MODEL USIX

Level 2 Digital Electronics 2 ( )

42 LCD Overhead Video Display Support Specifications (No Electrical required on rear curtain wall)

DIN EUROCARD CONNECTORS

DSP 18 Sub active subwoofer. user manual

XW3D. Simple Wiring of Sensor Actuators. Connector Terminal Boxes. Specifications. Materials and Finish. Connection Combinations

COLOUR CHANGING USB LAMP KIT

LED Spot 300W. Please read this user manual before your operation

CR-6 MIXER USER MANUAL ENGLISH. Order Code: MIXE01

STANDARD FOR TELECOMMS WIRING AND TERMINATIONS

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

with additional normally-open signalling contact l With integrated AS interface Safety at Work.

Products according to UIC 552

Safety Codes Council Conference Banff C Panel Discussion

Nixie Clock Type Frank 3

Emtelle Aerial Blown Fibre

T850 Day & Night Security Camera

Cold Shrink Straight Joint

Transcription:

4 Mobility Pass This project has been funded with support from the European Commission. This publication reflects the views only of the author, and the Commission cannot be held responsible for any use which may be made of the information contained therein.

Mobility Pass Mobility Pass Learner First Name Family Name Training Aeronautical engineering level 3; aircraft manufacture electrical pathway Programme Units in this programme: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Mobility Unit 12 Unit 14 Home Institution (name, address) Contact Person (name, phone number, e-mail) Host institution (name, address) Contact Person (name, phone number, e-mail) In the first column of the following sheets short descriptions of the Mobility Units (MU) which are part of the unit (Typical Professional Task TPT) are listed. Although these descriptions are rather skill-oriented, please consider the lying knowledge, skills and key competences that can be displayed. These lying rows show that the respective Learning Outcome (LO) is not a simple operation but a complete and complex action including cognitive and key competence aspects. 3

Remarks: Mobility unit observed/ supported Unit 12: Production of bunched Assessment instruction surveillance independen tly Place Date Signature Production of copper bunched Production of fibre glass bunched Reading & standing work order Work resource-saving Providing & preparing the material Knowledge about material property Cutting cables, crimping Cooperating with the colleagues, asking for advice when needed Testing and preparing the circuit for transport to the next workplace Production of aluminium bunched Production of bunched 4

Mobility Pass Remarks: Mobility unit Unit 14: Passing bunched in aircraft systems observed/ supported Assessment instruction surveillance independen tly Place Date Signature Mounting brackets and splitters Setting ground points Mounting raceways Passing bunched Setting of connectors Reading & standing work order Work resource-saving Knowledge of different characteristics of the connectors Providing & preparing the material Crimping, connecting Cooperating with the colleagues, asking for advice when needed Approving work order 5

Appling test equipment and voltage Testing of connectivity & grounding Passing bunched by performing the MU above in context 6

Mobility Pass Attachment: Description of the units 12. Production of bunched for aircraft systems The production of wires and bunched (for energy, signals and data) for aircraft systems is one of the principal tasks of the profession. The basics of the production of bunched are engineering drawings, technical regulations and dimensional sketches. Examples for activities are to crimp and to plug contacts and connectors and to seal connectors. The requirements concerning functionality and quality of wires or bunched have to be considered and checked during production. After finishing the production of a certain circuit, it has to be checked carefully. Two examples of these checks are isolation and continuity tests. The rigorous rules (by VDE, Electrical engineers syndicate) concerning health protection and safety at work have to be considered during the checks, especially when working with high voltages. 14. Passing bunched in aircraft systems When producing new aircraft systems mainly bunched are passed. When modifying an aircraft single wires are passed too. Basics for passing bunched or wires are valid manufacturing instructions concerning the respective aircraft. First of all the bunched circuit has to be checked separately. While passing the circuit the technical and structural conditions (e. g. bending radii, joints, cable clips, protection of edges) have to be taken into account. Not only the bunched but also the cable clips, decal information and danger notices have to be mounted. The skilled worker inspects the passed bunched circuit again and marks it according to the valid instructions. The documentation of the accomplished work is an integrated element of this professional task. Depending on the respective manufacturing order final inspection of the passed wires or bunched is either done by the skilled worker or through another quality assurance process. 7