ImproX SupaGate 4-Channel Controller INSTALLATION MANUAL

Similar documents
FlexiScan. Impro FlexiScan 4-Channel Controller INSTALLATION MANUAL

ImproX (TRT) Twin Remote Terminal INSTALLATION MANUAL

ImproX (TRT) Twin Remote Terminal

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

SNG-2150C User s Guide

Access Control Keypad for MK-DV, JB-DV

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Art M Digital codelock module

2 CHANNEL RECEIVER DISPLAY POTENTIOMETER COM2 NC2 NO2


Before you can install your LCD TV on the wall, you must fi rst remove the base using the steps below:

Model: S-4904T/R. Wireless HD Transmission System. User Manual. Please read this User Manual throughout before using.

Model 1476-C SuperQuad HR

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

O P E R A T I O N M A N U A L. RF-Reader. Stand-alone-Reader Leser 2plus with RS-232 interface

Troubleshooting. 1. Symptom: Status indicator (Red LED) on SSR is constant on. 2. Symptom: Output indicator (Yellow LED) on SSR is flashing.

SPX-5600 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface SPX-5600MAN. Page 1 of 20

INTRODUCTION INSTALLATION LIGHTNING RETARDING LOOPS. Figure 1. Relay Box Antenna Connections. Relay Box Cable Connections

Ultra-ViewRF 8HD Director Monitor. User Operation Manual

SERIES BNC 50, COAXIAL MINIATURE CONNECTORS

VNS2200 Amplifier & Controller Installation Guide

Re:source. Communication Module. SAT Version. Dominating Entertainment. Revox of Switzerland. E2.00

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

Site Installation Model MP-8433

1995 Metric CSJ SPECIAL SPECIFICATION ITEM 6031 SINGLE MODE FIBER OPTIC VIDEO TRANSMISSION EQUIPMENT

Site Installation Model MP-8424

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS FROM 300 cm. UP TO 450 cm. of width

LDG ALK-2 Two-Port Audio/Linear/Key Switch

Digital Active Outdoor DVB-T/T2 Antenna

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

Rain+Birdt. Landscape Irrigation & Maintenance Remote System. Quick Start Guide 4.00 F G H K 9X. c n. System Components

SPECIAL SPECIFICATION 6911 Fiber Optic Video Data Transmission Equipment

User Manual CXE Rev (12) CXX Series. User Manual. Teleste Corporation CXE810. Fibre optic receiver

VITEK VTM-TLM191 VTM-TLM240

Operating instructions Electronic preset counter Type series 717

INSTALLATION INSTRUCTIONS FOR

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

SPECIAL SPECIFICATION 1291 Fiber Optic Video Data Transmission Equipment

Welcome to your. Wireless transmitter and receiver kit

LAUREL ELECTRONICS, INC.

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

Operating Instructions

Indoor/Outdoor Security System with Quad Monitor User s Manual

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

TL5024 MEMORY LIGHTING CONSOLE OWNERS MANUAL. Version 1.01

Dimensions. Model Number. Electrical connection. Features. Pinout Product information. Indicators/operating means. LGS25 Serie.

ACTIVE IF SPLITTER/COMBINER UHP-IFS

ST-CCTV-VBAC 1 Channel UTP Active Video Balun Transceiver

MAXTECH, Inc. BRC-1000 Series. C-Band Redundant LNB Systems. Technology for Communications. System Block Diagrams

User Manual. SWIT ELECTRONICS CO., LTD Model: S-4904P Wireless HD Transmission System(with Panel Receiver) Ver:A

DATA SHEET. The Advantys model STBDAI5260 Digital Input Module provides 2 isolated discrete input points that operate on a 115 VAC power source.

SAL Series Wireless Clock (V1)

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

SPECIAL SPECIFICATION 1987 Single Mode Fiber Optic Video Transmission Equipment

PRELIMINARY. Orbis CU. Preliminary Data Sheet!

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Instrukcja montażu. FLEX LED Neon Instalacja

application software

1 EX5. Technical Characteristics. Dimensions

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

AES-402 Automatic Digital Audio Switcher/DA/Digital to Analog Converter

1x12 VGA & Audio over CAT5 Splitter

(1) (2) (3) Bedienungs- und Montageanleitung. Safety instructions. Structure of the device

In-Ceiling Electric Motorized Front Projection Screen Evanesce Series. User s Guide

application software

RF Wireless Receiver (Model S4PU-DC-ANT3)

of Switzerland FM Tuner MK2 E 2.01

ARS x4 MATRIX SWITCHER Instruction Manual

TAC1 Telephone Entry System

WDP02 Wireless FHD Kit User Manual

Black & White Wireless Video Surveillance System

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

Gazer VI700A-SYNC2 and VI700W- SYNC2 INSTALLATION MANUAL

BBV REAL TIME HQ DISPLAY QUAD MANUAL

D21DKV IP VIDEO DOOR STATION. Brushed Stainless Steel Display Module Keypad Module

VNS2210 Amplifier & Controller Installation Guide

Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02

D21DKV IP VIDEO DOOR STATION. Display Module Keypad Module

2.4GHz Digital Wireless Video Door Phone User Manual

Optical Distribution Box 300 Installation Guide. Version : R0.0

TITLE BOX PAGE ONLY. DO NOT MAKE FILM DO NOT PRINT

Standard RS232 RS ma

Foreword: The purpose of this document is to describe how to install and configure Neets 4 relay box

Contactless encoder Ri360P0-QR24M0-HESG25X3-H1181

2.4 GHz WIRELESS VIDEO SENDER SYSTEM MODEL: VS6234

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

Index. Index. 1.0 Introduction...2 This Manual Operation Finger Lift Cable Lift Pneumatic Operation...

IPSTB1200 /IPC3200 Media Client User guide

HDMI Cross Converter

LINK EXT40-4KECO. 4K 40m HDMI Extender. User Manual. Version: V1.0.1

ERbic Bus Interface Connector System. Catalog E /06 Edition 4

Contactless Encoder SSI RI360P0-QR24M0-HESG25X3-H1181

PLL2210MW LED Monitor

AW900mT. User s Manual. Point-to-multipoint. Industrial-grade, ultra-long-range 900 MHz non-line-of-sight wireless Ethernet systems

Motor Operated Solar Shade with Valance Installation and Care Instructions Complete Video Instructions Available Online at

Chapter 4. Dish Antenna Installation. Installing a DISH 500 Antenna. Finding the Satellites

Transcription:

MODEL NUMBER: SGI911-1-1-GB-XX IMPROX SUPAGATE SPECIFICATIONS ImproX SupaGate 4-Channel Controller INSTALLATION MANUAL Working Environment... Passive Frequency... RF Frequency... Security... Input Voltage... The SupaGate is designed to work in an indoor or protected outdoor environment similar to IP20. The SupaGate is, therefore, NOT sealed against water. 125 khz. 433.92 MHz. ImproX DCT, Dynamic Code Transmission Technology. 10 V DC to 14 V DC. Power Requirements Current (ma) Power (W) Input Voltage 12 V DC, 1 Antenna Reader, all Relays OFF... 60 0.72 Input Voltage 12 V DC, 1 Antenna Reader, all Relays ON... 220 2.64 Relays Relay Output... Relay Contact Ratings... Installer Interfaces LED Indicators 7-Segment Display... Push-buttons... 4 Relays, each with NO, COM and NC contacts. 10 A at 28 V DC, 5 A at 220 V AC. 2 Displays, Red (externally visible). 4 Push-buttons (externally accessible).

INSTALLATION INFORMATION Accessories Find the following when unpacking the SupaGate Controller: A SupaGate housed in a Black tinted, Polycarbonate Plastic Cabinet. The SupaGate consists of a 2-piece Top Cover and a Base. CAUTION: General DO NOT use the Metal-oxide Varistors (25 Vrms, 500 A, 77 V max clamping) with mains power applications. Four Metal-Oxide Varistors, 25 Vrms, 500 A, 77 V max clamping. Four Black tinted, Polycarbonate Plastic Standoffs. Two Brass Wood Screws (3.50 mm x 25 mm). Two Wall Plugs (7 mm). An extra Serial Number Label. Remember the following when installing the SupaGate: Read Range CAUTION: The SupaGate is susceptible to excessive RF interference, reducing the range. Always site test the SupaGate, prior to installation, in its installation location for optimum RF read range. The SupaGate has a tested RF read range of between 10 m to 30 m (11 yd to 33 yd) when used with the ImproX QT (XQT904-1-1-GB-XX). The passive read range varies from between 25 mm to 76 mm (1 in to 3 in) depending on the Antenna Reader and Tag used. Antenna Reader Distance The ideal cable distance between the SupaGate and its Antenna Reader ranges between 2 m to 16 m (7 ft to 53 ft). Achieve this by using good quality screened, twisted pair cable. Distance between Antenna Readers from DIFFERENT SupaGates To avoid mutual interference, install the Antenna Readers alongside each other at least 500 mm (20 in) apart. Default Relay Selection For passive Tags presented to Antenna Reader 1, Relay 1 is automatically selected. When using the Normal (4-Digit) PIN-code, if you enter the PIN-code on Antenna Reader 1, Relay 1 is automatically selected. Buttons 1 to 4 on the ImproX (QT) Quad Transmitter activate Relays 1 to 4 on the SupaGate Controller. If only Buttons 1 and 2 are pressed during the Add RF Tags procedure then only those Buttons will activate the relevant Relays. Buttons 3 and 4 will have no action. Any combination is available. See Figure 1 for Button locations. SGI300-0-0-GB-08 April 2008 Page 2

Figure 1: Button Configuration for ImproX (QT) Quad Transmitter Programmed in Dynamic Code Transmission Mode The ImproX (QT) Quad Transmitter has its own passive Tag, separate from the transmitted codes. Presenting the ImproX (QT) Quad Transmitter passive Tag to Antenna Reader 1 drives Relay 1. Relay 1 Relay 2 Relay 3 Relay 4 Quad Transmitter Button 1 Button 2 Button 3 Button 4 Passive Tag Antenna - - - Reader 1 4-Digit PIN-code Antenna - - - Reader 1 5-Digit PIN-code PIN XXXX1 PIN XXXX2 PIN XXXX3 PIN XXXX4 (Antenna Reader 1) Request to Exit (RTE) Input RTE Door 1 RTE Door 2 - - Arc Suppression Table 1: Relay Allocation Summary Snubber devices are recommended for EMF Flyback and Arc Suppression when driving an inductive load with the Relay, see Figure 2. Figure 2: EMF Flyback and Arc Suppression SGI300-0-0-GB-08 April 2008 Page 3

MOUNTING THE SUPAGATE CAUTION: CAUTION: CAUTION: DO NOT mount the Controller on or close to a metal surface. Mount the SupaGate in a suitable indoor location, or protected outdoor location. Mounting the SupaGate in a location unprotected against rain will damage the SupaGate Controller. Make certain that you mount the Controller on a vibration-free surface. NOTE: If you intend mounting the SupaGate on a damp wall, use the supplied standoffs to position the SupaGate away from the wall. NOTE: Test the SupaGate, in the proposed installation location before mounting in position, ensuring the read range meets your needs. For best performance, position the Controller for clear line-of-sight in the direction of the movement. The antenna should be in the vertical plane. In Figure 3, a Tag moving along Motion 1 will be in line-of-sight of the antenna throughout the 10 m distance from first detection to the Controller. However, a Tag moving along Motion 02 will move out of line-of-sight of the antenna once it reaches Point A in Figure 3. Figure 3: Line of Sight Communication SGI300-0-0-GB-08 April 2008 Page 4

1. After removing the SupaGate from its packaging, straighten the flexible Antenna, this ensures an improved RF read range. 2. Position the SupaGate in clear line-of-sight, preferably 1.50 m to 2 m (5 ft to 6 ft) above the ground, in the direction of movement, with the Antenna vertical. 3. Secure the Cabinet to the mounting surface, using two suitable screws and wall plugs (supplied) nuts and bolts or rivets. CONNECTING THE SUPAGATE Figure 4 shows the layout of the SupaGate. Figure 4: SupaGate Layout SGI300-0-0-GB-08 April 2008 Page 5

Figure 5 shows a typical connection diagram for the SupaGate. Figure 5: Typical SupaGate Electrical Connections SGI300-0-0-GB-08 April 2008 Page 6

USER INFORMATION Mode and Action POWER-UP RUN MODE Reading Tags Unknown Tag 7-Segment Display LED Displays Display Duration then enters Run Mode Rotates in a circular manner Tag Found PROGRAMMING MODE Adding Passive Tags 1. In Run Mode press the ADD Pushbutton for less than. until the desired Tag Location is shown. 3. Present the Passive Tag to the Antenna Reader. 4. Press ADD to return to Run Mode. NOTES: Each new Tag Code received will display the Location at which it is being added. If the Tag already exists, it will be deleted and re-added in the same location. Displays the Tag Memory Location (01-99) Displays the first free Location (01-99) Displays the Passive Tag (Card) number as follows: Blank Space SGI300-0-0-GB-08 April 2008 Page 7

Mode and Action Adding RF Tags 1. In Run Mode press the ADD Pushbutton for less than. until the desired Tag Location is shown. 3. Press only the Buttons on the ImproX (QT) Quad Transmitter that are required to be allowed. 4. Press ADD to return to Run Mode. NOTES: Each new Tag Code received will display the Location at which it is being added. If the Tag already exists, it will be deleted and re-added in the same location. 7-Segment Display LED Displays Displays the first free Location (01-99) Displays the Button Number as follows: Display Duration Adding Normal (4-Digit) PIN-codes 1. In Run Mode press the ADD Pushbutton for less than. until the desired Tag Location is shown. 3. Enter your 4-digit PIN-code on the Keypad Antenna Reader, followed by the # Key on the Keypad Antenna Reader. 4. Press ADD to return to Run Mode. NOTE: Ensure you enter the complete 4- digit code, followed by the # Key to gain entry. Displays the first free Location (01-99) Displays the PIN-code as follows: Blank Space SGI300-0-0-GB-08 April 2008 Page 8

Mode and Action Adding Special (5-Digit) PIN-codes The PIN-code entered activates only the Relay specified as the 5 th digit of the PINcode. 1. In Run Mode press the ADD Pushbutton for less than. until the desired Tag Location is shown. 3. Enter your 4-digit PIN-code on the Keypad Antenna Reader, followed by a 1-digit reference to the Relay you want to activate. Press the # Key on the Keypad Antenna Reader to complete the entry. 4. Press ADD to return to Run Mode. NOTE: Ensure you enter the complete 5-digit code, followed by the # Key to gain entry. Deleting Tags or PIN-codes 1. In Run Mode press the DELETE Pushbutton. until the desired Tag Location is shown. 3. Press DELETE to delete the desired Location. 4. Specify more Locations to be deleted, or press DELETE to return to Run Mode. 7-Segment Display LED Displays Displays the first free Location (01-99) Displays the PIN-code as follows: Display Duration Bulk Delete 1. Power down the SupaGate. 2. Power up the SupaGate while simultaneously pressing the ADD and DELETE Push-buttons. 3.?? is displayed, after all is deleted and de is displayed. SGI300-0-0-GB-08 April 2008 Page 9

Mode and Action Replacing Lost Tags 1. Delete the lost Tag from its Tag Location. (See the Deleting Tags section). 2. Add the new Tag to the abovementioned Tag Location. (See the relevant Adding Tags section). Set Relay Durations 1. In Run Mode press the ADD Pushbutton for longer than. to specify the duration of Relay 1 in seconds (00 = Toggled Mode). NOTE: The factory default setting is 01. 7-Segment Display LED Displays Displays the first free Location (01-99) Displays selected Tag Memory Location Displays the Relay Drive Time in seconds (01 99 seconds) Display Duration 1. Press the ADD Push-button for less than. to specify the duration of Relay 2 in seconds (00 = Toggled Mode). NOTE: The factory default setting is 01. 1. Press the ADD Push-button for less than. to specify the duration of Relay 3 in seconds (00 = Toggled Mode). NOTE: The factory default setting is 01. 1. Press the ADD Push-button for less than. to specify the duration of Relay 4 in seconds (00 = Toggled Mode). NOTE: The factory default setting is 01. 3. Press ADD for less than to go back to Run Mode. Displays the Relay Drive Time in seconds (01 99 seconds) Displays the Relay Drive Time in seconds (01 99 seconds) Displays the Relay Drive Time in seconds (01 99 seconds) SGI300-0-0-GB-08 April 2008 Page 10

COMPLICATED CONCEPTS If the Tag + PIN-code function is required, then register a Tag at Antenna Reader 1 and a 5-digit PIN-code specifying Relay 2. Relays 1 and 2 can then be wired in series. Appropriate Relay durations need to be chosen. If the incorrect PIN-code is entered 3 times in succession, the Keypad locks for 20 seconds. During this period the RF System remains operational. If you select Button 1 on the ImproX (QT) Quad Transmitter to activate Relay 1, presenting the ImproX (QT) Quad Transmitters passive Tag to Antenna Reader 1 automatically activates Relay 1. This will only utilize 1 of your 99 Locations. Blank Space SGI300-0-0-GB-08 April 2008 Page 11

TAG LOCATIONS Document all Tag owners at their respective Tag Memory Locations (in the SupaGate) using Table 2. This list provides an easy reference when you need to delete Tags from the SupaGate. Owner Relay or PIN-code Relay or PIN-code Owner 1 2 3 4 5/R 1 2 3 4 5/R 01 27 02 28 03 29 04 30 05 31 06 32 07 33 08 34 09 35 10 36 11 37 12 38 13 39 14 40 15 41 16 42 17 43 18 44 19 45 20 46 21 47 22 48 23 49 24 50 25 51 26 52 SGI300-0-0-GB-08 April 2008 Page 12

Owner Relay or PIN-code Relay or PIN-code Owner 1 2 3 4 5/R 1 2 3 4 5/R 53 77 54 78 55 79 56 80 57 81 58 82 59 83 60 84 61 85 62 86 63 87 64 88 65 89 66 90 67 91 68 92 69 93 70 94 71 95 72 96 73 97 74 98 75 99 76 Table 2: Tag Location Table Blank Space SGI300-0-0-GB-08 April 2008 Page 13

GUARANTEE OR WARRANTY CAUTION: We reserve the right to nullify the products guarantee or warranty where you have not properly installed the Metal-oxide Varistors. This product conforms to our Guarantee or Warranty details placed on our Web Site to read further please go to www.impro.net. USER NOTES SGI300-0-0-GB-08 April 2008 Page 14

USER NOTES SGI300-0-0-GB-08 April 2008 Page 15

This manual is applicable to the ImproX SupaGate 4-Channel Controller, SGI911-1-1-GB-01. (The last two digits of the stock code indicate the issue status of the product). SGI300-0-0-GB-08 Issue 09 Apr 2008 ImproX SupaGate\English Manuals\LATEST ISSUE\XSupGate-insm-en-09.docx SGI300-0-0-GB-08 April 2008 Page 16