Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Similar documents
Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

7 Day Digital Programmer

7 Day Digital Programmer 3 Channel Surface Mount

24 Hour & 7 Day Digital Immersion Heater Timeswitch Article

LP20. Installation & User Guide. Dual Channel Programmer. Part number 25039DR

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

Lifestyle. Dual Channel Programmer. for heating AND hot water. Installation and User Instructions DUAL CHANNEL ISSA

TDDFM14 OWNER S MANUAL

Comfort System T-32-P Universal Thermostat. Operation Manual

Digital Time Switch. Installation & Operating Instructions

ULTRA-VANSTAT WIRELESS PROGRAMMABLE THERMOSTAT FOR CARAVANS

7 Day Digital Time Switch

1 Channel Multi-Purpose Programmer User Instructions

Radio Thermostat Clock

RAMMER INSTRUCTION MANUAL FITTING & OPERATING INSTRUCTIONS NEL PROGRAMMER. NSTAR Si MODELS

CP027. User Operating Instructions. Two Channel Central Heating and Hot Water Programmer

Programmable Room Thermostat With RF

16 Amp Electronic 24 Hour/7 Day Time Controller

Digital Economy Seven Programmer

ACT 10 Digital Keypad Operating & Installation Instructions This manual is found at

RT505TX Programmable. The RT505TX can be used with any of these receivers RXBC605 RXWBC605 RXVBC605 RXST MHz

ST9100C User Guide. Features

DIGITAL TIME SWITCH 7 DAY WITH INPUT DGU100A DGUM100A DGLC100A DGLC200A

CP017 USER OPERATING INSTRUCTIONS. Single Channel Timeswitch

ChannelPlus H17XL Series 2 User Operating Instructions

Junior Max (JR Max ) Controller

TP7001 Range Electronic 7 Day Programmable Room Thermostat. Danfoss Heating. Installation Guide

XTM72 Exerciser Timer Module

ServicePlus S17R Series 2 User Operating Instructions

Waterline Room Controller - Type WLCT3

ST625TX Digital Room Thermostat

EN Wireless programmable thermostat

FN:4181NX_M1.DOC MC4181NX MASTER CLOCK MC4181NX

Overview: Specifications: Installation Instructions:

XTM72E & F Real-Time Clock Modules

DTS400B - DZS400BP 3/9/07 10:14 AM Page 1

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

S-Series Digital Thermostat. Instruction Manual Model No ST620RF

Operation Guide 6022 ENGLISH

Dial Ezy INSTRUCTION MANUAL N IRRIGATION CONTROLLER 4 or 6 Station Model SUITABLE FOR INDOOR USE ONLY OTHERWISE WARRANTY IS VOID

Installation & Programming Manual. Please read before using this timer.

SSPT724A Timer Quick Start Guide

User s Guide. GreenKeeper 212 Features: Automatic Sprinkler System Controller

OUTDOOR IRRIGATION CONTROLLER LDC-6 LDC-11. User Manual

7 Day Digital Light Switch with Optional Dusk Start

Inserting the batteries. Basic settings of the remote control

WiFi Controlled Fused Spur Time Switch

talento 800 Series 365-Day One, Two and Four Circuit Electronic Time Controls Functional Description

SBL /SBLG Series Wireless Clock

2 2 Relay outputs. M DIN W72 H7mm. LE7 Weekly/Yearly timer

1 Overview. 2 Specifications. 3 Installation Instructions. HPT724 Programmable LCD Timer PN 52765:A 1/25/06 ECN Product Installation Document

Timer Modules. EL11 24 Hour Module EL17 7 Day Module. Installation & Operating Instructions

Two (2) Channel 365 Day 24 Hr. Timer/Controllers

MRX1 1. Getting to know your MRX1 wireless controller

USER & ENGINEER INSTRUCTION MANUAL

Weekly Time Switch. Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1min

Electronic 1-Circuit 7-Day Time Switch With 100-Hour Backup

SECURITRON PRIME TIME MODEL DT-7 INSTALLATION AND OPERATING INSTRUCTIONS

Operating Manual. Basic Control BC16. two-channel for eco moon

PT Two (2) Channel 365 Day 24 Hr. Timer/Controller

REGO Start&Go USER MANUAL

INSTALLATION INSTRUCTIONS FOR. MODEL 2230LED

EZ Pro Jr. Installation and Programming Guide For EZ Pro TM Jr. models:

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

STX Stairs lighting controller.

INSTALLATION & OPERATING INSTRUCTIONS SINGLE/TWO CHANNEL 24HR/7 DAY TIMER. Cat No. TR671/TR672TOP

Timer Modules. MEU11 24 Hour Module, MEU17 7 Day Module (Without Housing)

EC7000, EC7004 and EC7005 Single Channel Electronic Time Controls

Electronic 2-Circuit 24-Hour Time Switch With 100-Hour Backup

User Manual CC DC 24 V 5A. Universal Control Unit UC-1-E. General Information SET. Universal Control Unit UC-1 Of Central Lubrication PAUSE CONTACT

INSTALLATION INSTRUCTIONS FOR

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

Master Time Clock MTC Users Manual

Nixie Clock Type Quattro'

1. General Information:

User s Guide. ECx Features: Automatic Sprinkler System Timer

Model IQ4-PC User Manual Revision Date:

Installation & Operation Manual. BEC PM1 Controller Time/Flow/Volume Controller. Water Control Solutions

Installation and Operation Manual. YMP Series Signal Programmer

Valcom Wired Digital Clock

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

INSTALLATION INSTRUCTIONS MODEL VSBX-236 LED 3 X 8 INDOOR SCOREBOARD

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Battery Operated Controllers

How do I delete a. Remove Here

Solid-State Digital Timer

SceneStyle2 User Guide

Conference Speaker Timing System. Operating Instruction Manual

Master Clock Controller. User Guide. pyramidtimesystems.com

24Hour/7Day Electronic Timeswitch

ST8-WiFi Timer. Installation Guide and Operations Manual. English MIN M D YYYY

TORK DGU100/DGUM100 7 DAY DIGITAL TIME SWITCH INSTALLATION AND OPERATING INSTRUCTIONS READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT

User s Guide. ECx Features: Automatic Sprinkler System Timer

TORK DGS180 DIGITAL SIGNAL TIMER 24 HOUR WITH DAY OMIT

2 Hour Electronic Boost Timer

MAKING MODERN LIVING POSSIBLE. TS715Si Electronic Single Channel Timeswitch with Service Interval Timer. Installation Guide.

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

Telemetry Receiver Installation Guide

Master Clock Controller. User Guide. pyramidtimesystems.com

Transcription:

Instruction Manual TPSE201 (181422) - BOSS TM Universal Programmer TPSE101 (569565) - BOSS TM Universal Timeswitch Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder. Please read this manual prior to installation or use. Retain for future reference. Always isolate the mains supply before removing the unit from the backplate. Please leave these instructions with the end user where they should be kept in a safe place for future reference Installation The TPSE201/TPSE101 is easily installed using the backplate supplied. This can be mounted directly to the wall or a single gang recessed box using the holes provided; cable entry is from the rear. Specification Power supply Switch rating Switch type 230V/50Hz 6(2)A Single pole, double throw (SPDT) Operating temperature 0 C - 50 C Storage conditions -20 C - 60 C Frost protection temperature 5 C Programme Time display Memory Backlight 5/2, 7 day or daily selectable by jumper 3 setting per day 12 or 24 hour Internal memory back-up Green LED Switches/Jumpers The installer should select the jumper positions required if changing from the factory pre-sets, these jumpers are found on the rear of the unit. Always enable the internal memory back up battery before installing the unit, Switch/Jumpers Program type P/G (TPSE201 only) Internal backup battery Function 3x2 pins jumpers for 5+2 days (factory default setting), 7 days program or daily 3x1 pin jumper for fully pumped and controlled system (factory default setting) or gravity-fed hot water system. 3x1 pin jumper to enable/disable the internal backup battery (disabled is the factory default setting) 1

BackPlate & Wiring This unit does not require an earth connection. The earth terminal is provided for safe retention of circuit earth wires only. 1. Select a suitable location noting the advice in page 1 of this manual, a suitable mounting height is 1.5m above the floor 2. Isolate the AC mains supply, note this must be 230Vac and fused at 6 Amps. 3. Optimum cable size is 1.5mm 2 Check the system wiring specification to confirm connections and cable core colour identification. 4. Cable must enter from the rear of the backplate. 5. Securely fix the backplate directly to the wall or fit to a recessed back box. 6. Terminate cables in accordance with the wiring diagram on the unit, ensuring conductors are firmly gripped between the square brass washers. 7. This appliance is double insulated and must not be earthed. The earth terminal is provided for safe retention of circuit earth wires only. 8. The backplate has 6 holes through which to fix to the surface of your choice. Please note that when fitting the controller to the backplate, some pressure downwards is required to lock the pins in the unit to the connectors in the backplate. Secure the controller to the backplate with the captive screws at the bottom taking care not to over tighten. 9. Enable the memory back up. 10. Restore mains to system when all the associated items are fully installed and test for correct operation. NOTE: mains power is required to programme unit. Please note: Always isolate the mains power prior to fitting the unit onto the backplate and when the backplate is exposed. Terminals: TPSE101 Terminal Name Function N Neutral L Live 2 Common (ex-factory with jumper to L) 3 (CH OFF) Central Heating OFF 4 (CH ON) Central Heating ON E Earth Remark: For volt free setting, remove jumper between L & 2. TPSE201 Terminal Name Function N Neutral L Live 1 (HW OFF) Hot Water OFF 2 (CH OFF) Central Heating OFF 3 (HW ON) Hot Water ON 4 (CH ON) Central Heating ON E Earth 2

Internal Wiring Wiring diagrams (TPSE201) Alternative wiring connections for other BOSS TM room thermostats * Wireless thermostat receiver unit MUST have permanent mains power from fused spur to operate correctly. 3

Wiring diagrams (TPSE101) Note: Wireless thermostat receiver unit MUST have permanent mains power from fused spur to operate correctly. User Instructions Keyboard Key Mode (CH) Hr+ (CH) Adv (CH) Mode (HW) Only for TPSE201 Hr+ (HW) Only for TPSE201 Adv (HW) Only for TPSE201 Function Operating mode selection for Central Heating Temporary override for Central Heating Advance to next program for Central Heating Operating mode selection for Hot Water Temporary override for Hot Water Advance to next program for Hot Water Increase set Temperature. Decrease set Temperature. Turn on backlight for 10 seconds. Activate/de-activate holiday override. Set Select Press to begin/confirm programming settings. Press to select day(s)/time/temperature. 4

Initial Power Up After power up or Reset is pressed, all programmes are reset. During system reset, all LCD segments are turned on for 2 seconds. After 2 seconds, the programmer is initialized and the display will look like this. Setting of the TPSE201/TPSE101 after reset Function Status after Reset Operation Mode Auto mode 12/24 hour 24h Clock 12:00 AM/PM indicator N/A Date 2016-Jan-1 Daylight Saving On Program Default factory setting Program Number indicator Depends on program SET indicator Off PROG indicator Off Mode indicator(s) Auto CH/HW indicator(s) Depends on program Output Relay Depends on program After reset, the TPSE201/TPSE101 will operate in Auto mode. Default Program Settings after reset Same for both 5-2 and 7 days programmes. Program 1 2 3 CH HW Output Day of week (Mon to Sun) Day of week (Mon to Sun) On 06:00 06:00 Off 08:00 08:00 On 10:00 10:00 Off 12:00 12:00 On 18:00 18:00 Off 22:00 22:00 5

Setting the Clock Press and hold Set and Select in Normal mode for 3 seconds to enter Clock setting mode. 12 hr or 24 hr, and SET are displayed. All other indicators are cleared. Release Set and Select, press or to toggle between 12 hr or 24 hr format. Press Select, clock and SET are displayed. Hour is flashing to indicate that it is the selected item to be adjusted. Release Select, press or to increase or decrease the hour respectively. Press and release Select, press or to increase or decrease the minute respectively. Press and release Select to set the Year, y xx is displayed, press or to increase or decrease the year respectively. The year can set between 20 16 and 20 99 inclusive. Press and release Select to set the Month of Year, m xx is displayed, press or to increase or decrease the month respectively. The month can set between 01 to 12. Press and release Select to set the Day of Month, d xx is displayed, press or to increase or decrease the day respectively. The day can set between 01 to the end of the month which is determined by the year and month set above. 6

Press and release Select to set Day Light Saving, dls xx is displayed, press or to enable or disable the Day Light Saving. Press and release Select to allow change of hour again, but not the 12/24 hour format. Press and hold or for 2 seconds to advance the value quickly without repeated presses. Selected item will stop flashing when a key is pressed. The selected item will flash again once the key is released. Press Set at any time to confirm the setting and return to normal mode. TPSE201 / TPSE101 will return to normal mode after 10 seconds if no key is pressed, the clock is also updated with the latest setting. Day Light Saving When enabled, the clock will automatically shift 1 hour ahead of the current set time from the last Sunday in March at 2:00am until the last Sunday in October at 2:00am. 5-2, 7 days or daily program Programmed events must happen in chronological order i.e., the OFF time cannot be earlier than the ON time and the time of program 3 cannot be earlier than that of program 2 etc. Each time can be set between 3.00 am and 2.50 am (on the next day) to allow you to programme the CH/HW to stay on past midnight, if required. The PROG display indicates the program number. The CH/HW display indicates whether CH or HW is being programmed. No CH/HW indicator is displayed in TPSE101. The selected item will be flashing and can be adjusted by or key. Program time is changed in 1 minute steps. Press and hold or for 2 seconds to advance the value quickly without repeated presses. Selected item will stop flashing when a key is pressed. The selected item will flash again once the key is released. The unit will return to normal mode after 10 seconds if no key pressed, Program settings are stored. Program review/changes are allowed even when Temporary Override or Adv Mode is enabled. 5-2 days program selected Central Heating and Hot Water have independent programmes set. 3 different time settings can be programmed for weekdays or weekend. Total 6 settings for TPSE101, and 12 settings for TPSE201. To review or change program, press Set in normal mode to enter programming mode. The weekday and SET PROG are displayed, all other indicators are cleared. The weekdays are flashing to indicate that it is the selected item to be adjusted. 7

Press or to select the program set for Weekday/Weekend/CH/HW to be reviewed or adjusted in the sequences below. TPSE101: Weekday CH -> Weekend CH -> Weekday CH -> TPSE201: Weekday CH -> Weekend CH -> Weekday HW -> Weekend HW -> Weekday CH -> Press Set at any time to confirm the setting and return to normal mode. Press Select at any time to confirm the selection. The hour is flashing to indicate that it is the selected item to be adjusted. Press Select to step through the items to be reviewed or adjusted in the sequences below. (Program 1 ON) hour minute (Program 1 OFF) hour minute (Program 2 ON) hour minute (Program 2 OFF) hour minute (Program 3 ON) hour minute (Program 3 OFF) hour minute and then cycle back to (Program 1 ON) Press Set at any time to confirm the setting and return for program set selection. 7 days program selected Central Heating and Hot Water have independent programmes set. 3 different time settings can be programmed for each day of week. Total 21 settings for TPSE101 and 42 settings for TPSE201. To review or change a program, press Set in Normal mode to enter programming mode. The Monday and SET PROG are displayed. All other indicators are cleared. The day of the week is flashing to indicate that it is the selected item to be adjusted. 8

Press or to select the program set for Day of Week to be reviewed or adjusted in the sequences below. Monday CH <-> Monday HW <-> Tuesday CH <->... <-> Sunday HW -> Monday CH Press Set at any time to confirm the setting and return to normal mode. Press Select at any time to confirm the selection. The hour is flashing to indicate that it is the selected item to be adjusted. Press Select to step through the items to be reviewed or adjusted in the sequences below. (Program 1 ON) hour minute (Program 1 OFF) hour minute (Program 2 ON) hour minute (Program 2 OFF) hour minute (Program 3 ON) hour minute (Program 3 OFF) hour minute and then cycle back to (Program 1 ON) Press Set at any time to confirm the setting and return to program selection. Daily program selected Central Heating and Hot Water have independent programmes. 3 different time settings can be programmed for all days. Total 3 settings for TPSE101 and 3 settings for TPSE201. To review or change a setting, press Set in Normal mode to begin programming. The all day and SET PROG are displayed. All other indicators are cleared. All days are flashing to indicate that it is the selected item to be adjusted. 9

Press or to select the program set for Weekday/Weekend/CH/HW to be reviewed or adjusted in the sequence below. Weekday CH -> Weekday HW -> Weekend CH -> Weekend HW -> Weekday CH Press Set at any time to confirm the setting and return to normal mode. Press Select at any time to confirm the selection. The hour will be flashing to indicate that it is the selected item to be adjusted. Press Select to select among the items to be reviewed or adjusted in the sequences below: (Program 1 ON) hour minute (Program 1 OFF) hour minute (Program 2 ON) hour minute (Program 2 OFF) hour minute (Program 3 ON) hour minute (Program 3 OFF) hour minute and then cycle back to (Program 1 ON) Press Set at any time to confirm the setting and return to program selection. Operating Mode Selection: In normal operating mode, press Mode to step through the four operating modes: On, Once, Auto, and Off. For each press and release of Mode, the operating mode is cycled in the following sequence: On Once Auto Off On The mode indicator is changed to indicate the selected mode. 10

Function of each operating mode: Operating Mode On Once Auto Off Function Continuously on On for 1 period a day, from Program 1 ON to Program 3 OFF Automatic program control Continuously off Fully Pumped and Controlled System (P). Central Heating and Hot Water can be operated independently. Gravity-fed Hot Water System (G). Central Heating cannot be operated without Hot Water. Central Heating (CH) On Once Auto Off Selectable mode for Hot Water (HW) On On, Once On, Once, Auto On, Once, Auto, Off In a poorly controlled gravity circulation hot water system, whenever the boiler comes on to service the heating, there will inevitably be some circulation though the hot water storage tank, which will then heat up. Therefore, whenever the HEATING is ON, the HOT WATER is also ON. It is therefore NOT possible to have independent programmes for heating and hot water hence both CH and HW are programmed together. If you have this type of installation (gravity circulation hot water circuit WITHOUT a hot water control valve), your installer must restrict the Programmer to being a Gravity-fed hot water system (G). 11

Temporary Override: Hr+ Program Override When the device is in either Auto, Once or Off mode, press Hr+ to activate the Hr+ program override mode. SET will be displayed, and the mode indicator(s) are lit. For TPSE201, c1 is displayed on the left side for central heating and/or h1 is displayed on the right side for hot water. For TPSE101, 1h is displayed on the right side only. For TPSE201 with P selected, for hot water, press Hr+ to activate the Hr+ program override. For TPSE201 with P selected, for central heating, press Hr+ to activate the Hr+ program override. For TPSE201 with G selected, for central heating, press Hr+ to activate the Hr+ program override. For TPSE101, press Hr+ to activate the Hr+ program override. 12

When Hr+ boost mode is activated, the On mode indicator will flash, together with the current mode. e.g. If the current mode is auto mode, the On mode icon is flashing and Auto mode icon remains on. For TPSE101, the display shows 0h, 1h, 2h, or 3h in boost mode. For TPSE201, the display shows C1:h1 Each press of Hr+ will increase the duration of the override by 1 hour. Maximum duration is 3 hours. Pressing until the number rolls back to 0 will disable the Hr+ program override. When Gravity-fed Hot Water System is selected, if the HW duration is shorter than the CH duration, the HW duration will be set to the same duration of CH automatically. Press Set or wait 10 seconds without any key press to begin the period of override and return to the home screen. A channel with override activated is turned on immediately; a channel with override not activated will keep current operational status. The mode indicator(s) will flash at the on position to indicate the temporary override. After 10 seconds, the clock is displayed with the Mode indicator(s) flashing to indicate that the override mode is activated. CH or HW with override activated will return to the previous operating mode at the end of the set duration and the corresponding Mode Indicator will stop flashing. When the Hr+ Program Override mode is activated and the clock is displayed, press Hr+ to review the current settings. SET is displayed, but there is no change of the internal count down timer(s). If there is no further key press within 10 seconds, the clock will be displayed again with the mode indicator(s) flashing. When reviewing the current settings, subsequent press of Hr+ will add 1 hour to the internal count down timer(s). Press Set or wait 10 seconds without further key press to start counting down and return to the home screen. Pressing Hr+ repeatedly until the duration becomes 0 will stop the corresponding channel. When Gravity-fed Hot Water System is selected, pressing of HW Hr+ will set the duration the same as CH. The channel(s) will enter advance override mode when activated as above. The channel(s) return to their previous set mode when user disables the advance override. The channels will function as above whether the program jumper is set to G or P. 13

When the channel is in Hr+ program mode, the channel cannot be changed to Advance mode. In G mode (Gravity System), when you use the hot water Hr+ function, they will operate as normal. However, the heating Hr+ function will also bring on the hot water. This is a consequence of the type of system you have, and is normal. The following is an example list of CH programmed operations. Program 1 2 3 CH Output Day of week On 06:00 Off 08:00 On 10:00 Off 12:00 On 18:00 Off 22:00 1) In Auto mode The clock is at 11:00 and is executing program 2 (10:00 turn on, 12:00 turn off). Now user presses Hr+ twice to begin 2 hours boost mode. Now, the program 2 will extend 2 hours. i.e. turning off is delayed from 12:00 to 14:00. 2) In Once mode The clock is at 11:00 and is executing program 1: On to Program 3-Off (06:00 turn on, 22:00 turn off). Now user presses Hr+ twice to begin 2 hours boost mode. Now, the Once program will extend 2 hours. i.e. turning off is delayed from 22:00 to 24:00. 3) In Off mode The clock is at 11:00. No channel is on. The user presses Hr+ twice to begin 2 hours boost mode. Now, the channel is turned on and will remain on for 2 hours. i.e. the relay is turned on at 11:00 immediately and then will turn off at 13:00. Advance Override When the device is in either Auto or Once mode, press Adv to activate the Advance Override mode. The next program will be activated with and ADV icon showed together with Auto/Once icon. When the channel is in Advance mode, the channel cannot be changed to Hr+ override mode. In G mode (Gravity System), when you use the hot water ADV function, they will operate as normal. However, the heating ADV will also bring on the hot water. This is a consequence of the type of system you have, and is normal. 14

The following is an example list of CH programmed operations. Program 1 2 3 CH Output Day of week On 06:00 Off 08:00 On 10:00 Off 12:00 On 18:00 Off 22:00 1) In Auto mode Case 1: Device is in channel ON state. - At 11:00. Device is in Program 2 On and the channel is ON. - The user presses Adv. The relay switches OFF and ADV icon is shown. - At 12:00, device reaches the time of Program 2 Off. The channel is kept OFF but ADV icon is NOT shown. i.e. Advance override is finished. - (Similar when Device in Program 1 Off state) Case 2: Device is in channel OFF state - At 9:00 device is in Program 1 Off state and the channel is OFF. - The user presses Adv. The relay switches ON and ADV icon is shown. - @10:00, device reaches start time of Program2-On. Now the relay is kept On but ADV icon is NOT shown. i.e. Advance override is finished. 2) In Once mode Case 1: Device is in channel ON state. - At 11:00, device is in Program 2 On and the channel is ON. - The user presses Adv. The relay switches OFF and the ADV icon is shown. - At 22:00, the relay is kept OFF but the ADV icon is NOT shown. i.e. Advance override is finished. - At 06:00 of the next day, the device reaches the start time of program 1 On and the channel switches On. Case 2: Device is in channel OFF state - At 09:00, device is in Program 1 Off state but the channel is ON while in Once mode - The user presses the Adv, the channel switches OFF and the ADV icon is shown. - At 22:00, the channel is kept OFF but the ADV icon is NOT shown. i.e. Advance override is finished. - At 06:00 of the next day, the device reaches the start time of program 1 On and the channel switches On. 15

Holiday Override In normal mode, press and hold setting mode. for 3 seconds to activate the Holiday Override 1 dy, SET, H PROG indicator, and MODE indicator(s) at off position are displayed, all other indicators are cleared. Day is flashing to indicate that it is ready to be adjusted. Press or to increase or decrease the number of days to turn off the system. Maximum days to turn off the system is 31 days. If the number rolls back to 0, Holiday Override will be disabled. Press and hold or for 2 seconds for values to advance quickly. Press Set or wait 3 seconds without further key presses to start counting down. SET will disappear and both CH and HW will be turned off immediately. Press for 3 seconds again to de-activate the Holiday Override mode. The Programmer returns to the normal mode. The Programmer counts each pass through midnight as a day. LCD Backlight LCD backlight is activated when or any key is pressed. The backlight will be turned off 10 seconds after the last key press. LCD backlight will not operate on battery back-up power only. LCD backlight is illuminated when changing the Clock, Program, and Temporary Override Temperature settings. AC Monitoring Mains power is monitored continuously. If the mains fails, output will be turned off immediately, all the functions will be paused, only the clock and mode icon is displayed, all other indicators will be cleared. 16

The TPSE101/TPSE201 will return to Normal mode after mains power is resumed. Backup Battery The thermostat is shipped from the factory with the battery installed. To stop it from discharging during shipment and storage, the battery is disconnected by a jumper on the back of thermostat. This jumper (Memory On) must be moved before the thermostat is mounted on the wall. The battery that retains the time and date during a power failure, without mains power, should last up to one year. If the time and date need to be reset after a power failure, this is an indication that the battery needs to be replaced. To replace the battery, open the back of the Thermostat case using a screw driver. Remove the screw marked by a red tab (see image) and carefully lift off the top circuit board. Socket Screw Remove the old battery from its clip. Insert a new battery (type CR2032 or equivalent) observing the correct polarity. Carefully re-position the top circuit board pressing gently back in to place taking care to engage the pins from the lower circuit board into the socket. Re-fit the rear casing. 17

Control Patterns Control Status Indication - LED output indicator is illuminated whenever the output is on. TPSE101 TPSE201 BOSS is a registered trademark of the Travis Perkins Group Registered Office: Travis Perkins plc, Lodge Way House, Lodge Way, Harlestone Road, Northampton. NN5 7UG 18