LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

Similar documents
LC1D12B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V AC coil

LC1D150B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 24 V AC 50/60 Hz coil

LC1D50AFE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D12P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A V AC coil

LC1D32P7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A V AC 50/60 Hz coil

LC1D65AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC 50/60 Hz coil

LC1D09FE7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC1D80F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 80 A V AC 50/60 Hz coil

LC1D50AF7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A V AC 50/60 Hz coil

LC1D09B7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

LC1D25G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A V AC coil

LC1D150G7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A V AC coil

LC2D09E7 REVERSING CONTACTOR 575VAC 9A IEC

LC1D09M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A V AC coil

LC3D180AV7 TeSys D - star delta starter - 3 x 3P (3 NO) - 18 A V AC coil

LC3D80B7 TeSys D - star delta starter - 3 x 3P (3 NO) - 80 A - 24 V AC coil

LC3D115M7 TeSys D - star delta starter - 3 x 3P (3 NO) A V AC coil

GV2ME. Main. Device short name. Device application

GV2P05. Main. Device short name. Device application

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A - screw clamp terminals. Main.

GV2ME. Product data sheet Characteristics. TeSys GV2-Circuit breaker-thermal-magnetic A -screw clamp terminals. Main.

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

GV2ME083 TeSys GV2 - Circuit breaker - thermal-magnetic A - spring terminals

GV2ME086 TeSys GV2 - Circuit breaker - thermal-magnetic A - lugs-ring terminals

GV2ME. Main. Device short name. Device application

GV3P80 TeSys GV3P thermal-magn motor circuit breaker 70-80A EverLink

A V 50Hz / V 60Hz

AS09..S 3-pole Contactors - Spring Terminals

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

GV3P401 TeSys GV3 termo magnetski-prekidač-30 40A- EverLink BTR/izravni konektori

TeSys contactors LC1-D09pp (5) LC1-D12pp (5) 0.325

PBC series. RoHS. Ready. IEC-Type Contactors & Accessories 9-80 Amp AC-3, Amp AC-1 AC Coils. P&B PBC Series IEC Type Contactors & Accessories

with handle LIMOGES Cedex 1. DESCRIPTION - USE 3. DIMENSIONS Symbol: Technology: Use:. For controlling a load remotely via a switch 2.

Datasheet - SRB301LC 24VAC/DC

Magnecraft Power Relays

Series CT7N Bimetallic Overload Relays

Type: DILM25 10(24V50HZ) Article No.:

Contactor 4 kw / 400 V with 3 Main Contacts and max. 4 Auxiliary Contacts Series 8510/122

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Type: DILM12 10(24VDC) Article No.:

Safety dialogue solutions

Ordering details. Approval. Classification

Minicontactorrelay,2NO/2NC,DCoperated

02/11/2015

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

Datasheet - SRB-E-201ST

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC

16 A and 25 A power contactors with or without handle

Contactors. Agency approvals. UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

Agency approvals UL 508 Guide No. NLDX2, File # E CE/Semko Certified EN :1991 IEC DP 30 C 3P - 1 /B

AC1036. Definite Purpose Contactors

Modular pulse operated latching relay 16 A

Bulletin 190 IEC Modular Starter System

Circuit-Breakers for Motor Protection Series 8523/8

CT7N CT7 CT7K 4 6 CT TJ 4 6 CT7K TKK 6 10 CT TK 6 9 CT7K TKL

Magnecraft General Purpose Relays 782 Power Series SPDT 20 A; DPDT 15 A

Data Sheet Definite Purpose Contactors Ex9CK Series

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Description Set value in neutral conductor is synchronous with set value Ir of main pole. R.m.s. value measurement and thermal memory CSA 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Type: NZMN1 A100 Article No.: Sales text Circuit breaker3p systems/cable prot. Ordering information Number of poles

I r A I i = I n x. Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Interface Relays and Optocouplers Product group picture

Data sheet. CI-TI TM Contactors and Motor Starters Contactors CI EI 520B1286

ALLEN BRADLEY TIMING RELAY

Kuhnke Technical Data. Contact Details

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Protective function Systems, cable, selectivity and generator protection. i 2 t constant function: switchable. I r A

Series CDP2 Definite Purpose Contactors

Manual Motor Starter Specifcations

Pluggable interface relays CR-M Miniature relays

Series CDP2 Definite Purpose Contactors

I r A Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Panel-mounting thermostats, type series EM

Description Set value in neutral conductor is synchronous with set value Ir of main pole. CSA 100. conductor. I r A 50-63

TeSys circuit-breakers

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

110 Volt AC at 50 Hertz, 120 Volt AC at 60 Hertz. 20 Amp (UL Continuous), 7 Amp (AC-3), 22 Amp (AC-1)

llen-bradley 194R-HM4-NFPA3

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Type Contact form Model PCB SPDT G6E-134P-ST-US G6E-134PL-ST-US. Type Contact form Model

Protection against direct contact Finger and back of hand proof to VDE 0106 Part 100

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

1.1. IEC Contactors and Starters. Contents Description Relays and Timers... Miniature Controls... Contactors and Starters. XT IEC Power Control

Magnetic and Hydraulic-Magnetic Circuit Breaker

LED control gear Compact fixed output

Bulletin 100-G IEC Contactors

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US

DMX and 4000 air circuit breakers from 800 to 4000 A

Definite Purpose Contactors

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

LED Driver Compact dimming

Hinges with built-in safety multiple switch SUPER CFSW. Hinges and connections. IP67 RoHS PA

LED Driver Compact fixed output

Generator protection relay

Movable Contacts Heavy duty silver cadmium oxide composition to resist welding and contact erosion for greater reliability

PHASED OUT. LED control gear Compact fixed output. Driver LC 40W 900mA fixc C SNC China Domestic ESSENCE series

Transcription:

Product data sheet Characteristics LC1D09F7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 110 V AC coil Product availability : Stock - Normally stocked in distribution facility Price* : 94.00 USD Main Range Product name Product or component type Device short name Contactor application Utilisation category Poles description Power pole contact composition System Voltage [Ie] rated operational current Motor power kw Motor power HP (UL / CSA) Control circuit type [Uc] control circuit voltage Auxiliary contact composition Jan 17, 2019 TeSys TeSys D Contactor LC1D Motor control Resistive load AC-1 AC-3 AC-4 3P 3 NO <= 300 V DC power circuit <= 690 V AC 25...400 Hz power circuit 25 A (<= 140 F (60 C)) at <= 440 V AC AC-1 power circuit 9 A (<= 140 F (60 C)) at <= 440 V AC AC-3 power circuit 2.2 kw at 400 V AC 50/60 Hz AC-4 2.2 kw at 220...230 V AC 50/60 Hz AC-3 4 kw at 380...400 V AC 50/60 Hz AC-3 5.5 kw at 500 V AC 50/60 Hz AC-3 5.5 kw at 660...690 V AC 50/60 Hz AC-3 4 kw at 415...440 V AC 50/60 Hz AC-3 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors 1 hp at 230/240 V AC 50/60 Hz 1 phase motors 2 hp at 200/208 V AC 50/60 Hz 3 phases motors 2 hp at 230/240 V AC 50/60 Hz 3 phases motors 5 hp at 460/480 V AC 50/60 Hz 3 phases motors 7.5 hp at 575/600 V AC 50/60 Hz 3 phases motors AC 50/60 Hz 110 V AC 50/60 Hz 1 NO + 1 NC [Uimp] rated impulse withstand voltage 6 kv conforming to IEC 60947 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Overvoltage category [Ith] conventional free air thermal current III 25 A at <= 140 F (60 C) power circuit 10 A at <= 140 F (60 C) signalling circuit Irms rated making capacity 250 A at 440 V power circuit conforming to IEC 60947 140 A AC signalling circuit conforming to IEC 60947-5-1 250 A DC signalling circuit conforming to IEC 60947-5-1 Rated breaking capacity 250 A at 440 V power circuit conforming to IEC 60947 [Icw] rated short-time withstand current Associated fuse rating Average impedance [Ui] rated insulation voltage Electrical durability Power dissipation per pole Safety cover Mounting support 105 A <= 104 F (40 C) 10 s power circuit 210 A <= 104 F (40 C) 1 s power circuit 30 A <= 104 F (40 C) 10 min power circuit 61 A <= 104 F (40 C) 1 min power circuit 100 A 1 s signalling circuit 120 A 500 ms signalling circuit 140 A 100 ms signalling circuit 20 A gg at <= 690 V coordination type 2 power circuit 25 A gg at <= 690 V coordination type 1 power circuit 10 A gg signalling circuit conforming to IEC 60947-5-1 2.5 mohm at 50 Hz - Ith 25 A power circuit 600 V power circuit certifications CSA 600 V power circuit certifications UL 690 V power circuit conforming to IEC 60947-4-1 690 V signalling circuit conforming to IEC 60947-1 600 V signalling circuit certifications CSA 600 V signalling circuit certifications UL 0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 at Ue <= 440 V 0.2 W AC-3 1.56 W AC-1 With Plate Rail Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 Product certifications Connections - terminals BV CCC CSA DNV GL GOST LROS (Lloyds register of shipping) RINA UL Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable end Power circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable end Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable end Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - Power circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - Power circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - Power circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable end Power circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - 2

Tightening torque Operating time Power circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - Power circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm Power circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2 Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2 4...19 ms opening 12...22 ms closing Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 Mechanical durability Operating rate 15 Mcycles 3600 cyc/h at <= 140 F (60 C) Complementary Coil technology Control circuit voltage limits Inrush power in VA Hold-in power consumption in VA Heat dissipation Without built-in suppressor module 0.3...0.6 Uc drop-out at 140 F (60 C), AC 50/60 Hz 0.8...1.1 Uc operational at 140 F (60 C), AC 50 Hz 0.85...1.1 Uc operational at 140 F (60 C), AC 60 Hz 70 VA at 68 F (20 C) (cos ϕ 0.75) 60 Hz 70 VA at 68 F (20 C) (cos ϕ 0.75) 50 Hz 7.5 VA at 68 F (20 C) (cos ϕ 0.3) 60 Hz 7 VA at 68 F (20 C) (cos ϕ 0.3) 50 Hz 2...3 W at 50/60 Hz Auxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1 Type mirror contact (1 NC) conforming to IEC 60947-4-1 Signalling circuit frequency Minimum switching current Minimum switching voltage Non-overlap time Insulation resistance 25...400 Hz 5 ma signalling circuit 17 V signalling circuit 1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact > 10 MOhm signalling circuit Environment IP degree of protection IP20 front face conforming to IEC 60529 Protective treatment TH conforming to IEC 60068-2-30 Pollution degree 3 Ambient air temperature for operation Ambient air temperature for storage Permissible ambient air temperature around the device Operating altitude 23...140 F (-5...60 C) -76...176 F (-60...80 C) -40...158 F (-40...70 C) at Uc 9842.52 ft (3000 m) without derating in temperature Fire resistance 1562 F (850 C) conforming to IEC 60695-2-1 Flame retardance V1 conforming to UL 94 Mechanical robustness Height Width Depth Product weight Vibrations contactor open 2 Gn, 5...300 Hz Vibrations contactor closed 4 Gn, 5...300 Hz Shocks contactor open 10 Gn for 11 ms Shocks contactor closed 15 Gn for 11 ms 3.03 in (77 mm) 1.77 in (45 mm) 3.39 in (86 mm) 0.71 lb(us) (0.32 kg) Ordering and shipping details Category 22345 - CTR,D-LINE,OPEN,NONREV-NEW Discount Schedule I12 GTIN 00785901206934 Nbr. of units in pkg. 1 3

Package weight(lbs) 0.78000000000000003 Returnability Y Country of origin ID Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Green Premium product Compliant - since 0627 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Product environmental profile Available Product end of life instructions Available California proposition 65 WARNING: This product can expose you to chemicals including: - - - - - - - Substance 1 Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. - - - - - - - More information For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months 4

Product data sheet Dimensions Drawings LC1D09F7 Dimensions (1) Including LAD 4BB (2) Minimum electrical clearance LC1 D09 D18 D093 D123 D099 D129 b without add-on blocks 77 99 80 b1 with LAD 4BB 94 107 95.5 with LA4 D 2 with LA4 DF, DT with LA4 DW, DL 110 (1) 123 (1) 111.5 (1) 119 (1) 132 (1) 120.5 (1) 126 (1) 139 (1) 127.5 (1) c without cover or add-on blocks 84 84 84 with cover, without add-on blocks 86 86 86 c1 with LAD N or C (2 or 4 contacts) 117 117 117 c2 with LA6 DK10, LAD 6K10 129 129 129 c3 with LAD T, R, S 137 137 137 with LAD T, R, S and sealing cover 141 141 141 (1) Including LAD 4BB. 5

Product data sheet Connections and Schema LC1D09F7 Wiring 6