IQDLOG SDI Logo Inserter

Similar documents
C Module Description

C Module Description

IQACO Changeover Switch

IQDDAC D to A Converter

C Module Description

IQBSFR AES/EBU Digital Audio ReMapper with Stereo Combiner and Gain Control

IQORXD Dual-Channel Multimode Fibre Optic Receiver for SDI

IQOTXD Dual-Channel Multimode Fibre Optic Transmitter for SDI

User Instruction Manual IQSDA30/IQSDA32. Intelligent Reclocking High Performance HD-SDI/SD-SDI Distribution Amplifiers. snellgroup.

IQLOG00- HD/SD-SDI Logo Inserter IQLOG01- SD-SDI Logo Inserter

IQDMENCS Encoder. Module Description

IQORX30 / IQORX31. Single Mode Fiber Optic Receivers for 3G/HD/SD-SDI Signals

C Module Description. IQMDMO MPEG-2 Decoder with MOLE Output

IQVDA00/01 Analog Video Distribution Amplifier with RollCall Control

Aspect Ratio Converter with Signaling

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION VIDEO CONNECTIONS GENERAL PURPOSE INPUTS & OUTPUTS SPECIFICATIONS...

IQDMX21 4 Channel Analog Audio Demultiplexer

EEG A1452 SCTE-104 Inserter Frame Card

IQOTXS Dual-Channel Single-Mode Fibre Optic Transmitter for SDI

IQDEC01. Composite Decoder, Synchronizer, Audio Embedder with Noise Reduction - 12 bit. Does this module suit your application?

C8491 C8000 1/17. digital audio modular processing system. 3G/HD/SD-SDI DSP 4/8/16 audio channels. features. block diagram

Model 4455 ASI Serial Digital Protection Switch Data Pack

Model 5240 Digital to Analog Key Converter Data Pack

C8000. switch over & ducking

EEG CB1512 Caption Legalizer & Relocating Bridge

Model 7130 HD Downconverter and Distribution Amplifier Data Pack

EdgeConnect Module Quick Start Guide ITERIS INNOVATION FOR BETTER MOBILITY

Introduction Display...1 Mounting...1 Firmware Version...2. ADL Operation... 3

COPYRIGHT 2018 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED NO PART OF THIS DOCUMENT MAY BE REPRODUCED IN ANY FORM WITHOUT THE PERMISSION OF

3G-HD/SD SDI Pattern Generator. User Manual

3G/HD/SD dual channel audio embedder/de-embedder

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart. Saab TransponderTech AB. Appendices. Project designation. Document title. Page 1 (25)

C8188 C8000 1/10. digital audio modular processing system. 4 Channel AES/EBU I/O. features. block diagram. 4 balanced AES inputs

User Instruction Manual IQMUX34. 3G/HD/SD-SDI Multiplexer for 8 Analog Channels.

Model 7600 HD/SD Embedder/ Disembedder Data Pack

IQDANR SDI Advanced Noise Reducer

User Instruction Manual IQOTR31. 3G/HD/SD-SDI Single Mode Fiber Optic Transceiver. snellgroup.com

FS1-X. Quick Start Guide. Overview. Frame Rate Conversion Option. Two Video Processors. Two Operating Modes

GNS600 SCTE104 VANC inserter, Ethernet data-bridge for 3G, HD and SD SDI Inputs and X31 Cue encoder/decoder

Kramer Electronics, Ltd. USER MANUAL. Model: 900xl. Power Amplifier

RPAN. Router Control Panel

Manual Version Ver 1.0

IQMUX00/02/10/12 4/8 Channel Digital Audio Multiplexer with Synchronizer

eyeheight dk3 SDI luminance keyer user manual

CEDAR Series. To learn more about Ogden CEDAR series signal processing platform and modular products, please visit

DRAFT RELEASE FOR BETA EVALUATION ONLY

R20AD 10-bit Universal Decoder R-series Card Module User Manual

C8000. sync interface. External sync auto format sensing : AES, Word Clock, Video Reference

Kramer Electronics, Ltd. USER MANUAL. Models: VS-162AV, 16x16 Audio-Video Matrix Switcher VS-162AVRCA, 16x16 Audio-Video Matrix Switcher

Kramer Electronics, Ltd. USER MANUAL. Model: FC Analog Video to SDI Converter

Features of the 745T-20C: Applications of the 745T-20C: Model 745T-20C 20 Channel Digital Delay Generator

VIDEO GRABBER. DisplayPort. User Manual

IQDBD00/01 HD/SD SDI 16 Channel AES/EBU Remultimplexer with Dolby Decoder

Kramer Electronics, Ltd. USER MANUAL. Model: VS x 1 Sequential Video Audio Switcher

8020A-D-DVB-03-MNL Issue 3. DVB-8020A-D Digital Video Buffer Delay Version USER MANUAL

American DJ. Show Designer. Software Revision 2.08

3Gb/s, HD, SD 16ch digital audio embedder with embedded domain audio shuffler, mixer and framesync COPYRIGHT 2018 AXON DIGITAL DESIGN BV

Ultra 4K Tool Box. Version Release Note

IQUDC33. 3G/HD/SD-SDI Dual Up, Down and Cross Converter with AES I/O. Inputs & Outputs - IQH3A/1A/3B enclosures. Features

C ch optical MADI & AoIP I/O. MASTER mode: A C8000 frame may be clocked via MADI input or AES67 network. AoIP Dante Brooklin II OEM module

Intelligent Security and Fire Ltd

Models 5360 and 5365 Four Channel Analog to Digital Video Converters and Embedders Data Pack

VISTEK V1633/A & V1633/D USER GUIDE.

COPYRIGHT 2016 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED

GFT Channel Digital Delay Generator

HD Caption Legalizer / Relocating Bridge MODEL CB512

FS3. Quick Start Guide. Overview. FS3 Control

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

TABLE OF CONTENTS 1. OVERVIEW INSTALLATION DA-3G CONNECTIONS SPECIFICATIONS SERIAL VIDEO INPUT...

DAC20. 4 Channel Analog Audio Output Synapse Add-On Card

VOB - data over Video Overlay Box

IQDMSES Multi-standard Digital Encoder

TECHNICAL MANUAL INTEGRITY 600 SERIES MDX644 HD/SD, AES/DOLBY E AUDIO DE-EMBEDDER/EMBEDDER

WaveMaker III Gartech Enterprises Inc. 12/17/2012

Instruction Manual. SMS 8104 Serial Digital Frame Delay

DT3162. Ideal Applications Machine Vision Medical Imaging/Diagnostics Scientific Imaging

Model 5250 Five Channel Digital to Analog Video Converter Data Pack

Model 7500 HD Video Processing Frame Synchronizer Data Pack

USER MANUAL. Kramer Electronics, Ltd. Models:

Snell & Wilcox. Operator s Manual MDD500S. NTSC Decoder. December 1998

Model VS-2A 2-Port VGA Switch with Audio & Serial Control

High-end bi-directional aspect ratio converter with digital and analog outputs COPYRIGHT 2008 AXON DIGITAL DESIGN BV ALL RIGHTS RESERVED

Rack-Mount Receiver Analyzer 101

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

V pro8 QUICK START GUIDE

Tebis application software

TABLE OF CONTENTS 1. OVERVIEW INDIVIDUAL CARD BLOCK DIAGRAMS... 2

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

Transmitter Interface Program

3G/HD/SD-SDI Universal Up, Down and Cross Converter

SERIAL DIGITAL VIDEO FIBER OPTIC TRANSPORT & DISTRIBUTION MODULAR SYSTEM FOR HDTV & SDTV

HDSDI-CHO-2x1 HD-SDI-CHO-2x1-PB

BBV REAL TIME HQ DISPLAY QUAD MANUAL

Hardware & software Specifications

User Instruction Manual IQDBT105. DVB-T/T2 Terrestrial Receiver & Monitor.

IQSYN20 HD/SD-SDI Frame Synchronizer

CDV07. Analog video distribution amplifier(s)

Marshall Electronics. Operating Instructions. Warranty. Model No. QVW Quad-Viewer Monitor with 4K Format Support

Kramer Electronics, Ltd. USER MANUAL. Model: VS-201YC. 2x1 s-video Switcher

F M2SDI 2 Ch Tx & Rx. HD SDI Fiber Optic Link with RS 485 & Aux. User Manual

Transcription:

IQDLOG SDI Logo Inserter Module Description The IQDLOG is a sophisticated SDI logo inserter. The unit is capable of adding static or animated, full 8-bit, colour logos at any point in the active picture region of the SDI stream. Logos or animation sequences can be of any size or length up to a total 250K pixels. Logos are downloaded over the RollCall network and stored in non-volatile memory. A simple animation control file allows easy creation and manipulation of the animation parameters (H/V position, fade and logo selection). All logos are uncompressed 4:2:2:4 with 8 bit (smooth) control of fade in and out. 3 GPIs inputs are provided that can remotely control all logo functions (-2 version only). They may be used separately or configured as a 3-bit binary coded input. C The IQDLOG is supplied with a suite of PC/RollCall-based utilities to process logo files. Industry standard file formats supported are TGA, BMP and PPM files. It will not support versions of these formats which include embedded alpha (key) channels or any form of compression. This logo creation download facility is used at the customers own risk; for the latest version please see the Snell & Wilcox web site homepage at www.snellwilcox.com. A crystal locked output helps in reducing incoming jitter and together with sync insertion provides a continuous output in event of input loss. The unit automatically detects 525 and 625 line inputs and will detect EDH errors and insert EDH on the output. For added flexibility four SDI outputs are provided. The unit will pass all HANC ancillary data. Full remote control via RollCallTM is included. Customised Logos Snell & Wilcox can provide a service to produce logos to customer s specifications. Contact your local Snell & Wilcox sales office for details. REAR PANEL VIEW GPI 2 1 3 2 1 IQDLOG-2 4 3 SERIAL OUTPUT SERIAL INPUT IQDLOG-1 2 1 SERIAL OUTPUTS SDI INPUT IQDLOGOPS 100403 Version 1 Issue 4 39.1

power power power information control home previous scroll adjust return modules lock help setup save recall OPEN IQDLOG SECTION 39 Versions of the module cards available are: IQDLOG-2 SDI logo inserter 4 SDI outputs with EDH and 3 GPI inputs Double width module IQDLOG-1 SDI logo inserter 2 SDI outputs with EDH (no GPI) Single width module IQDLOG-2A SDI logo inserter 4 SDI outputs with EDH and 3 GPI inputs Double width module IQDLOG-1A SDI logo inserter 3 SDI outputs with EDH and 1 GPI input Single width module Note that there are two styles of rear panels available. They are not interchangeable between the two styles of enclosures. However, the cards may be fitted into any style of enclosure. A Style Enclosure Rear panels with the suffix A may only be fitted into the A style enclosure shown below. O Style Enclosures Rear panels without the suffix A may only be fitted into the O style enclosures shown below. IQ display select (Enclosure order codes IQH3A-E-O, IQH3A-E-P, IQH3A-N-O, IQH3A-N-P) (Enclosure order codes IQH1S-RC-O, IQH1S-RC- AP, IQH1U-RC-O, IQH1U-RC-AP, Kudos Plus Products) (Enclosure order codes IQH3N-O, IQH3N-P) IQDLOGOPS 100403 Version 1 Issue 4 39.2

BLOCK DIAGRAM Audio/Ancillary Data Bypass Serial D1 Input Deserialize Keyer D1 Formatter D1 Output Serial D1 Outputs EDH Check Logo Store EDH Insert GPI x 3 CPU & RollCall RollCall Features Static or animated Serial Digital logo insertion Any size of logo, using up to 250K pixels User defined logos can be loaded over a PC network Video and Alpha-channel processing at 4:2:2:4 resolution Totally transparent to ancillary data Horizontal and vertical logo positioning anywhere in active picture Smooth fade with dedicated fade control Easy creation/modification of animations Continuous valid output 10-bit data paths throughout GPI control of all logo functions Automatic 625 and 525 operation User defined input failure Logo EDH checking and insertion to SMPTE RP165 RollCall Control IQDLOGOPS 100403 Version 1 Issue 4 39.3

TECHNICAL PROFILE Features Signal Inputs Serial Digital... 1 x SDI Standards... SMPTE 259M-C-1997 GPI... 3 Closing Contact style inputs (-2version only) Signal Outputs Serial Digital... Up to 4 x SDI Standards... SMPTE 259M-C-1997 Card Edge Controls (also available via RollCall) Input Standard... 525 / 625 / Auto EDH checking Logo... Reverse/stop/Forward/Single Cycle Logo Fade Max... 0 to 255 (off to full on) Logo Fade Min... 0 to 255 (off to full on) Logo H position... -120 to +718 samples (525) -138 to +710 samples (625) Logo V position... 0 to 500 lines (525) 0 to 600 lines (625) Fade...Fade In/ Fade Out (unit fades in to maximum fade value and fades onto minimum fade value) Fade in time...1 to 300 frames Fade out time...1 to 300 frames On Input Fail...Selectable Logo User Memories...16 [save / recall / name] Preset Unit...Returns all settings to factory defaults Functions Available via RollCall Only Logging...EDH, Input Loss and Standard Change Animation file download Logo Download...Note: The logo download software IQSSAM supports TGA, BMP and PPM files. It will not support versions of these formats which include embedded alpha (key) channels or any form of compression. Specifications Serial Input Return Loss... Better than 15 db to 270 MHz Maximum Input Cable length > 200 m (PSF1/2 or equiv. cable) Serial Output Level... 800 mv ±10% Output Return Loss... Better than -15 db to 270 MHz Output Jitter... < 0.2UI Insertion Delay... approx. 4 µs Logo Limits... The IQDLOG software released to date (V5.4.6 issue B cards and V6.0.6 issue C cards) is limited to a maximum Logo file size of 786,430 bytes. Power Consumption Module Power Consumption 6.2W max. IQDLOGOPS 100403 Version 1 Issue 4 39.4

SERIAL INPUT The serial digital input to the unit is made via this BNC connector that terminates in 75 Ohms. SERIAL INPUT SERIAL OUTPUTS These are the isolated Serial Digital outputs of the unit via BNC connectors for 75 Ohms. IQDLOG-2 2 4 1 3 SERIAL OUTPUT IQDLOG-1 2 1 SERIAL OUTPUTS IQDLOGOPS 100403 Version 1 Issue 4 39.5

GPI INPUTS GPI These three connectors are used for accepting GPI information (from mechanical switch contacts, relay contacts etc.) The resulting action that the unit takes may be programmed via RollCall. 3 2 1 IQDLOGOPS 100403 Version 1 Issue 4 39.6

CARD EDGE CONTROLS Note that the unit will respond to both local and remote control, one system overriding the settings of the other For cards using the RollCall remote control system, activating these switches will override the remote control settings. The RollCall control panel will then follow these settings. Note that in Main-frames where RollCall is not available SW4/7,should be set to ON (DOWN). This ensures that when the unit is powered-up the factory default settings of parameters not available as card edge adjustments, are loaded. With SW4/7 OFF (UP) the card will power-up with the last settings sent by the remote control panel. LED INDICATORS +5V and -5V When illuminated these LED s indicate that the +5 V and -5 V supplies are present. No I/P The No I/P LED will be continuously illuminated when the unit is not receiving an input signal. EDH Reporting The Present LED will be illuminated if EDH data is present on the incoming signal. The Hour LED indicates that an error has occurred in the last hour and the Sec LED indicates that an error has occurred in the last second. Note that SW4/8 resets these indicators. IQDLOGOPS 100403 Version 1 Issue 4 39.7

SWITCHES Two push buttons, a Hex switch and a 8 way DIL switch allow various functions and modes to be set. The DIL switch SW4 selects a particular function and the Hex switch SW3 selects a mode or variable parameter. The push buttons SW1, SW2 allow the value of the selected function/parameter to be adjusted. The Mode select switch SW3 may select a mode or a parameter that may be adjusted using SW1 and SW2. Note that to select the preset value both buttons (SW1 and SW2) should be pressed together. These switches allow the module to be operated when an active front panel is not available. More detailed information about these functions will be found under MENU DETAILS FUNCTION AND MODE SELECTIONS DIL SWITCH FUNCTIONS SW4 By setting these switches various modes of operation may be selected. (Down is ON and Up is OFF) Positions 1 to 6 are not used Position 7 When set to ON (Down) this allows the unit to operate under local control. Note that in Main-frames where RollCall is not available this switch should be set to the ON position. This ensures that when the unit is powered-up the factory default settings of parameters not available as card edge adjustments, are loaded. When set to the UP position the card will power-up with the last settings sent by the remote control panel. Position 8 Setting this to the ON position resets the EDH log indicators. IQDLOGOPS 100403 Version 1 Issue 4 39.8

SW3 This HEX switch selects a parameter that may be adjusted with the push-buttons SW1 and SW2. Note that SW1 increases a setting and SW2 decreases a setting. Continual pressure on the button will cause the setting to change continuously, the rate of change increasing with time. Pressing both together sets functions to their default values. SW3 Position 0 Position 1 Not Used Not Used Position 2: H Position Offset The horizontal position of the logo on the screen may be set using this function. The range of control is from -120 to +718 (525), -138 to +710 (625) samples in steps of 2 samples and preset is to 100. Position 3: V Position Offset The vertical position of the logo on the screen may be set using this function. The range of control is from 0 to +500 (525), 0 to 600 (625) lines in steps of 2 lines and preset is to 100. Position 4: Minimum Fade When a fade is activated the amplitude of the logo signal at the end of the fade may be set using this function. Minimum Fade will set the minimum amplitude of the logo at the end of a Fade-out function. The range of control is from 0 to 255 in steps of 1 unit and preset is to 0. Position 6: Select Animation This position allows the logo sequence to be selected using SW1 and SW2. Preset selects the static S & W Logo. Position 7: Step Animation This position allows an individual frame within an animated sequence to be selected. The range of control is from 1 to the maximum number of frames in 1 frame steps and preset is to frame 1. Position 8: Single Cycle Fwd/Rev When selected the logo sequence will complete one cycle forward (SW1 pressed) or one cycle back (SW2 pressed) and then stop. Position 9: Forward If an animated logo has been selected this function will allow the sequence to flow forward by pressing SW1. Pressing SW2 will stop the flow. Position A: Reverse If an animated logo has been selected this function will allow the sequence to flow in reverse by pressing SW1. Pressing SW2 will stop the flow. Position B: Fade In/Out Pressing SW1 will fade in the logo and pressing SW2 will fade out the logo. The fade-in and fade-out times will be those set via the RollCall menu system. Position 5: Maximum Fade Maximum Fade will set the maximum amplitude of the logo at the end of a Fade-In function. The Maximum Fade range of control is from 0 to 255 in steps of 1 unit and preset is to 255. Position C: Position D: Position E: Position F: Not Used Not Used Not Used In this position pressing SW1 and SW2 together sets all parameters to the default/preset conditions. IQDLOGOPS 100403 Version 1 Issue 4 39.9

IQDLOGOPS 202002 Version 1 Issue 2 39.10

OPERATION FROM AN ACTIVE CONTROL PANEL The card may be operated with an active control panel via the RollCall network. The menus available for this card are shown opposite and will appear in the Control display window. Operational details for the remote control panel will be found in SECTION 1 of the Modular System Operator's Manual. MENU DETAILS (see IQDLOG Menu System opposite) MAIN MENU The main, or top level menu allows various submenus to be selected by pressing the button adjacent to the required text line. Note that where a menu item is followed by three dots (...) this indicates that a further sub-menu may be selected. Whenever a menu item is selected the parameters of that selection will be displayed in the Information window of the front panel. Where the selection is purely a mode selection and does not enable a sub-menu, the text will become reversed (white-on-black) indicating that the mode is active. If the mode is not available for selection the text will remain normal. MAIN MENU IQDLOG MAIN MENU Logos... User_Memory... Setup... Unit... Logos Logos Controls... Select Sequence... Step Sequence Logo File Details This menu allows the logo to be selected and manipulated in various ways. Controls Methods of controlling the logo may be selected from this menu. Reverse Stop Fade Out Out_Time Fade_Max H_Pos Single_Cyl Reverse Controls Forward Reset Fade In In_Time Fade_Min V_Pos Forward If an animated logo has been selected these toggle functions allow the sequence to flow forward (from start to finish) or reverse (from finish to start). Note that if the Single_Cyl (single cycle) item is not enabled these functions will continuously recycle the sequence. If the Single_Cyl (single cycle) item is enabled these functions will only perform a single cycle event. Stop This function will stop an animated logo sequence. Reset This function will reset an animated sequence to the start of the sequence. IQDLOGOPS 100403 Version 1 Issue 4 39.11

Fade Out/Fade In By selecting these items the logo may be faded out of or faded into the main picture. Out_Time and In_Time When the Fade Out or Fade In functions above have been activated these items allow fade time to be set. Both times may be adjusted separately using the spinwheel and the value will be shown in the display. Picture Out/In_Time Position Fade_Max/Min 170 Frames Preset The range of control is from 1 to 300 frames in 1 frame steps and preset is to 1. Fade_Max and Fade_Min When a fade is activated the amplitude of the logo signal at the end of the fade may be set using this function. Picture Fade_Max/Min Position Fade_Max/Min 170 Preset Fade_Max will set the maximum amplitude of the logo at the end of a Fade-In function and Fade_Min will set the minimum amplitude of the logo at the end of a Fade-out function. The Maximum Fade range of control is from 0 to 255 in steps of 1 unit and preset is to 255. The Minimum Fade range of control is from 0 to 255 in steps of 1 unit and preset is to 0. H and V Position The position of the logo on the screen may be set using this function. Picture H/V_Position H/V_Position 436 Preset The horizontal position is set using the H_Pos item and the vertical position by using the V_Pos item. The H Position range of control is from -120 to +718 samples (525) or -138 to +710 samples (625) in steps of 2 samples and preset is to 100. The V Position range of control is from 0 to +500 (525), 0 to 600 (625) lines in steps of 2 lines and preset is to 100. Single_Cyl This item effects the operation of the Reverse and Forward functions. Single_Cyl (single cycle) not enabled When the Reverse and Forward functions are selected the logo sequence will continuously recycle. Single_Cyl (single cycle) enabled When the Reverse and Forward functions are selected the logo sequence will only perform a single cycle. It will stop on the last frame of the sequence. Select Sequence This menu allows a particular logo to be selected Logo Sequences Static S&W Logo Spin. S&W Logo 16:9 IQ Modular IQ Modular + S&W Static S&W Logo Spin S&W Logo 16:9 IQ Modular IQ Modular + S&W IQDLOGOPS 100403 Version 1 Issue 4 39.12

Step Sequence When activated the function allows an individual frame within an animated sequence to be selected. Picture Step Sequence Position Step Sequence Frame 1-25 Preset The range of control is from 1 to the maximum number of frames in 1 frame steps and preset is to frame 1. Note that this menu item will not be available if a static logo has been selected. Logo File Details This item will display the date and time information embedded in the Logo file. Logo File Details Logo File Details 06 Feb 2002 11:06: OK IQDLOGOPS 100403 Version 1 Issue 4 39.13

User_Memory User_Memory Read_Mem... Name_Mem... Save_Mem... Clear_Mem.. All settings of the unit may be stored in any of 16 non-volatile memory locations. These locations may be read, saved, given a name or cleared to the preset names by selecting the function to reveal the appropriate sub-menu. Read_Mem Read_Mem Memory_1 to Memory_16 This will reveal a list of 16 memory locations. When a particular location is enabled, settings will be changed to the values contained in that memory location. Save_Mem Memory_1 to Memory_16 Save_Mem This will reveal a list of 16 memory locations. When a particular location is enabled, current settings will be saved in that memory location. Name_Mem Name_Mem Memory_1 to Memory_16 Preset_All_Names This will reveal a list of the 16 memory locations that may be given a specific name. Memory_x Memory_x Memory_Name Clear Preset OK To compile/edit the text the right and left buttons adjacent to the upper text line in the menu should be used to select the character position in the text and the spinwheel used to select the character. The Clear function blanks out the selected character. The Preset function loads the default text. O.K. saves the caption text and returns to the main menu. Preset All Names Selecting this function will reset all the memory names to their default names. Clear_Mem Clear_Mem Memory_1 to Memory_16 Preset_All_Memories This will reveal a list of the 16 memory locations that may be selected and individually cleared to their default settings. All memories may be cleared to their default settings using Preset_All_Memories. IQDLOGOPS 100403 Version 1 Issue 4 39.14

Setup This menu allows various system parameters to be set. Setup Output_ Standard... Default_Output... EDH... Setup_GPI_Inputs... Logging... Output_Standard Output_Standard Auto 625 525 The output standard may be set to: Auto The output standard will be the same as the input 625 The output will be in the 625 standard. Note that if this is not the same as the input standard an error message will appear in the information window and the output picture will become black. If the input fails the output will become this standard. 525 The output will be in the 525 standard. Note that if this is not the same as the input standard an error message will appear in the information window and the output picture will become black. If the input fails the output will become this standard. Default_Output Default_Output Black Black & Current Log Black & IP Fail Log Select IPF Logo... IPF H_Pos IPF V_Pos This item allows an output picture to be selected in the event of a loss of input signal. The output picture that appears may be selected from the following list: Black The picture will become black Black & Current Logo The picture will be black with the currently selected logo; if the currently selected logo contains movement the movement will continue. Black & IP Fail Logo The picture will be black with the selected IPF logo chosen using the Select IPF Logo function below: This allows a different logo from the current logo to be chosen from the IPF Logo list. Select IPF Logo Static S&W Logo Spin S&W Logo IQ Modular IQ Modular + S&W This Logo will then appear when the input signal fails. Note that if a Logo that contains movement is chosen for this function, the Logo movement will be lost under input failure conditions and the first frame in the sequence will be displayed. IPF H and V Position The position of the logo on the screen may be set using this function. IPF Picture H/V_Position IPF H/V_Position 436 Preset The horizontal position is set using the H_Pos item and the vertical position by using the V_Pos item. The H Position range of control is from -120 to +718 samples (525) or -138 to +710 samples (625) in steps of 2 samples and preset is to 100. The V Position range of control is from 0 to +500 (525), 0 to 600 (625) lines in steps of 2 lines and preset is to 100. IQDLOGOPS 100403 Version 1 Issue 4 39.15

EDH This selection reveals a sub-menu that allows various Input or Output EDH parameters to be enabled. EDH Show_Stats Reset_Stats Show Stats (Statistics) When this function is enabled (text reversed) the information window will display the number of errors from the time the function was enabled. The elapsed time in hours, minutes and seconds is also displayed. Reset Stats (Statistics) Selecting this function will reset the EDH error count and the timer shown in the information window, to zero. IQDLOGOPS 100403 Version 1 Issue 4 39.16

Setup_GPI_Inputs (-2 version only) Setup_GPI_Inputs Edge_Trig State_Trig Disable In_Time Fade_Min Ed.Setup... St.Setup... Out_Time Fade_Max This will reveal a list of actions that may be chosen to occur when the GPI is activated. GPIx Open/Close OFF Reverse Reset Fade_Out Stop Forward Fade_In Memory GPI Overview The three GPI connectors on the rear panel are used for accepting GPI information (from mechanical switch contacts, relay contacts etc.) The resulting action that the unit takes may be selected from these menus. The type of input that activates the GPI function may be selected as either an edge trigger or by the change of state of any of the 3 GPI inputs. The edge trigger polarity may be selected as closed-to-open (Open) or open-to-closed (Close) for each of the GPI inputs. The function may also be disabled. To set up a function to be activated by an edge trigger. From the Setup_GPI_Inputs menu select Edge_Trig. Then select Ed.Setup; this will reveal the Edge Setup menu. Edge_Setup GPI1 Open... GPI2 Open... GPI3 Open... Close... Close... Close... Decide which GPI input to use (GPI 1, 2 or 3) and then select the edge trigger polarity required from the menu. Open will be activated by a closed-to-open action and Close will be activated by a open-to-closed action. OFF Setting Reverse* Reset Stop Forward* Fade IN Fade OUT Memory Action No action occurs Stop Sequence Sequence finish to start Sequence start to finish Return to start Fade in Logo Fade out Logo This will allow a memory location to be selected. Memory_1 to Memory_16 Memory Setting Action Memory 1 Selects Memory settings 1 to to Memory 16 Selects Memory settings 16 Make the required selection. Select Return on the front panel to return to the Edge Setup menu. The other GPI inputs may be programmed in the same way. * Note that if the Single Cycle item in the Logo template is not enabled these functions will continuously recycle the sequence. If the Single Cycle item in the Logo template is enabled these functions will only perform a single cycle event. IQDLOGOPS 100403 Version 1 Issue 4 39.17

To set up a function to be activated by a state trigger. From the Setup_GPI_Inputs menu select State_Trig; then select St.Setup; this will reveal the State Setup menu. Decide the 3-bit binary code that is required to activate the function from the State Setup menu. State_Setup GPI-OOO... GPI-OXO... GPI-XOO... GPI-XXO... GPI-OOX... GPI-OXX... GPI-XOX... GPI-XXX... Where O = Open and X = Closed and the GPI input order is as follows: GPI-X X O 3 GPI For example selecting GPI-XXO will activate the function when the state of the 3 GPI inputs changes to X (input 3 to closed), X (input 2 to closed) and O (input 1 to open) When a code has been selected the function menu will appear. This will reveal a list of actions that may be chosen to occur when the GPI is activated by the change of state to the selected code. OFF Reverse Reset Fade_Out GPI-xxx Stop Forward Fade_In Memory 2 1 Memory Memory_1 to Memory_16 Memory Setting Action Memory 1 Selects Memory settings 1 to to Memory 16 Selects Memory settings 16 Select Return on the front panel to return to the State Setup menu. Other codes may be programmed to activate other functions in the same way. For example GPI-XXO may have been programmed to Fade In the logo and GPI-XOO to Fade Out the logo. * Note that if the Single Cycle item in the Logo template is not enabled these functions will continuously recycle the sequence. If the Single Cycle item in the Logo template is enabled these functions will only perform a single cycle event. Disable The Edge-Trig and State_Trig functions will be inactive when this item is selected. Out_Time and In_Time These items allow fade in and fade out time to be set when activated by the GPI input setup. Setting OFF Stop Reverse* Forward* Reset Fade IN Fade OUT Action No action occurs Stop Sequence Sequence finish to start Sequence start to finish Return to start Fade in Logo Fade out Logo Both times may be adjusted separately using the spinwheel and the value will be shown in the display. Picture Out/In_Time Position Fade_Max/Min 170 Preset The range of control is from 1 to 300 frames in 1 frame steps and preset is to 30. IQDLOGOPS 100403 Version 1 Issue 4 39.18

Fade_Max and Fade_Min When a fade is activated by the GPI input setup the amplitude of the logo signal at the end of the fade may be set using this function. Picture Fade_Max/Min Position Fade_Max/Min 170 Preset Fade_Max will set the maximum amplitude of the logo at the end of a Fade-In function and Fade_Min will set the minimum amplitude of the logo at the end of a Fade-out function. The Maximum Fade range of control is from 0 to 255 in steps of 1 unit and preset is to 255. The Minimum Fade range of control is from 0 to 255 in steps of 1 unit and preset is to 0. Logging Unit This item allows basic information about the unit to be displayed and basic functions to be enabled. Unit Preset_Unit Software_Version Serial_No Restart Preset Unit Selecting this item sets all adjustment functions that include a preset facility, to their preset values. Note that this is a momentary action and the text will not become reversed. Software Version Software Version Software Version x.x.x OK Selecting this item reveals a display showing the version of the software fitted in the module. Select OK to return to the Setup Menu. If a logging device is attached to the RollCall network, information about various parameters can be made available to such a device. Serial Number Serial Number Selecting this item reveals a display that allows information about three parameters to be made available for logging. Seial Number xxxxxxxxx OK Input Change When activated, a change of input signal condition will be available for the logging device. EDH Errors When activated, EDH error reports will be available for the logging device. Selecting this item reveals a display showing the serial number of the module. Select OK to return to the Setup Menu. Restart This function allows the unit to reboot and all power-up settings to be enabled. IQDLOGOPS 100403 Version 1 Issue 4 39.19

THE INFORMATION WINDOW The parameters of the selected item in the Control window will be displayed in the Information window. An example is shown below: 01: IQDLOG Inp:OK Std:625 Logo Name here FDI <<< SCY The first line shows the name of the module card. This name can be changed using RollCall and the Remote Control Interface Menu. The second line shows that the signal input is receiving a valid signal (OK); if there is no signal or the signal is invalid it will show Inp:** The third line will display the name of the currently selected Logo. The fourth line shows various abbreviated text messages providing information about the logo status as described below: STP... Stop FDO... Fade Out FDI... Fade In <<<... Reverse >>>... Forward FD+... During Fade In FD-... During Fade Out SCY... Single Cycle sequence GPE = xxx... GPI Edge trigger input values GPS = xxx... GPI State trigger input values IQDLOGOPS 100403 Version 1 Issue 4 39.20

RollCall Control via a PC For full details please see the operator s manual for the IQSPCR, RollCall Software Installation Guide & Operational Overview IQSPCR is a PC application that runs under Windows 3.1x or 95. It allows full remote control of RollCall for this and other compatible units. SOFTWARE INSTALLATION GUIDE System Requirements The minimum requirement for installing the RollCall software is: RollCall PC Control Software (IQSPCR). IQ Modular 1RU or 3RU rack with Gateway card installed. PC running Microsoft Windows 3.1x or Windows 95. Either a RollCall PC card (IQCPC) or a RS232 to RS422 9 way converter fitted to the PC. Connecting the hardware: There are two choices for connecting the PC to the Modular IQ System: 75 Ohm co-axial cable BNC for box-to-box connections running at 2.5 Mbs. 1RU box 75 Ohm terminator 75 Ohm terminator 75 Ohm T-pieces 3RU box 75 Ohm sections 75 Ohm network PC IQCPC Each unit is physically joined via a T-piece connector. Each T-piece is connected by 75 Ohm co-ax cable to create a section. Each section of cable can be up to 400m. Each end of the network is terminated by a 75 Ohm terminator. RS422 running at 38.4 kbs asynchronous: 75 Ohm network 3RU box Computer RS422 link Gate -way 1RU box RS232/422 converter IQDLOGOPS 100403 Version 1 Issue 4 39.21

Connect the RS232/RS422 converter to COM1 or COM2 of the PC and connect this via RS422 cable to the 9 pin D on the IQ modular unit. This interface is specifically designed for third party connections into the system. This allows PC s or any other serial device access to any of the units within the system. Every active 1RU or 3RU box has one of these ports. Physical Interface - RollCall RS422 RxB Pin 3 RxA Pin 8 TxA Pin 2 TxB Pin 7 GND Pin 1 N.B. Connector is a socket, viewed from mating face. Equivalently, this is a plug, viewed from the rear, cable face. For reference, the A signal is at 0V at line idle, and the B signal at 5V. 5 4 3 2 1 9 8 7 6 5 9 4 8 3 7 2 6 1 9-Way Ribbon connections Standard Connections 9-way FUNCTION Connector 1 Frame Ground 2 Transmit A (Tx-) 3 Receive B (Rx+) 4 Receive Common 5 [No connection] 6 Transmit Common 7 Transmit B (Tx+) 8 Receive A (Rx-) 9 Frame Ground N.B. The D connector on the Gateway card could also be configured as RS485. Selection of the interface format is by a switch on the card. Note that RS485 interconnections should be pin to pin and only be used for Snell & Wilcox RollNet applications. DOWN i.e. towards the PCB selects RS422 UP i.e. away from the PCB selects RS485 Switch set to RS485 IQDLOGOPS 100403 Version 1 Issue 4 39.22

Software Installation Run SETUP.EXE from the installation diskette to install the suite of Rollcall programs. Product code IQSPCR contains the Rollcall Remote Control (rollcall.exe) and communications driver (commtrol.exe) programs. Product code IQSPCD contains the Rollcall Remote Control (rollcall.exe), communications driver (commtrol.exe), logserver (rolllog.exe) and logviewer (rollview.exe) programs. On startup, the setup program prompts for an installation directory. The default installation directory is C:\ROLLCALL. The set-up procedure will copy all the necessary files to this directory. Set-up will also create a Windows Group called RollCall. Depending on the product code of the diskette, Either two icons (RollCall and Commtrol for IQSPCR) or four icons (RollCall, Commtrol, LogServer and LogViewer for IQSPCD) will appear in the group. Overview ROLLCALL.EXE: This program allows control of RollCall compatible units. (IQ Modules, Supervisor, other S&W units with RollCall gateway). Each unit has a control template window for control of that device. The user can configure the program for USER, ENGINEER or SUPERVISOR access levels with password protection. It can install template files from new units automatically or by user request. ROLLLOG.EXE: This is the Log Server application that collects logging information from units on the network. Keeps a running log file of every event received. Writes a current status file for configured units and allows the LogViewer program to display the information. ROLLVIEW.EXE: This program displays the current status file written by ROLLLOG.EXE in a tabulated form. Coloured conditions highlight warning and failure states. Can be configured for network access for remote monitoring using share information from the LogServer program. COMMTROL.EXE: This program is called automatically by ROLLCALL.EXE or ROLLLOG.EXE and normally runs minimized. Usually, there is no need to run this program by itself. This program provides the basic communications with the PC card, serial comms ports or TCP/IP protocols. It also has monitoring facilities for data analysis. For more details see the operator s manual for the IQSPCR Section 3 IQDLOGOPS 202002 Version 1 Issue 2 39.23

RollCall Control Templates for the IQDLOG Logo This menu allows the logo to be selected and manipulated in various ways. Logo Sequence This menu allows a particular logo to be selected from the list. Note that for this and other screens the following applies: The symbol represents the Preset function and will return the function to the default setting. The and symbols at the ends of the scroll bar allow the value to be adjusted in discrete steps. The numerical value will be shown above the scroll bars. Step Logo Sequence This function allows an individual frame within an animated sequence to be selected. The range of control is from 1 to the maximum number of frames in the sequence in 1 frame steps and preset is to frame 1. Note that this item will not be available (greyed out) if a static logo has been selected. H Position and V Position The position of the logo on the screen may be set using these functions. The H Position range of control is from -120 to +718 samples (525) or -138 to +710 samples (625) in steps of 2 samples and preset is to 100. The V Position range of control is from 0 to +500 (525), 0 to 600 (625) lines in steps of 2 lines and preset is to 100. Fade Settings Maximum and Minimum Fade When a fade is activated the amplitude of the logo signal at the end of the fade may be set using this function. Maximum Fade will set the maximum amplitude of the logo at the end of a Fade-In function and Minimum Fade will set the minimum amplitude of the logo at the end of a Fade-out function. The Maximum Fade range of control is from 0 to 255 in steps of 1 unit and preset is to 255. The Minimum Fade range of control is from 0 to 255 in steps of 1 unit and preset is to 0. Fade In /Fade Out The Fade In and Fade Out times for Fade Out/Fade In functions under Controls may be adjusted here and the value in frames will be displayed. The range of control is from 1 to 300 frames in 1 frame steps and preset is to 1. IQDLOGOPS 100403 Version 1 Issue 4 39.24

Logo (continued) Animation Controls Methods of controlling the logo may be selected here. <<<Rev >>>Fwd If an animated logo has been selected the these toggle functions allow the sequence to flow forward (from start to finish) or in reverse (from finish to start) Note that if the Single Cycle item is not enabled these functions will continuously recycle the sequence. If the Single Cycle item is enabled these functions will only perform a single cycle event. Fade Out/Fade In When selected these items allow the logo to be faded out of or faded into the main picture over an adjustable time period time. Stop This function will stop an animated logo sequence. Reset This function will reset an animated sequence to the start of the sequence. Single_Cycle This item effects the operation of the Reverse and Forward functions. Single_Cycle not enabled When the Reverse and Forward functions are selected the logo sequence will continuously recycle. Single_Cycle enabled When the Reverse and Forward functions are selected the logo sequence will only perform a single cycle. IQDLOGOPS 100403 Version 1 Issue 4 39.25

Memories 1-8 and 9-16 All settings of the unit may be stored in any of 16 non-volatile memory locations. These locations may be Recalled, Saved, given a name or Cleared to the preset names by selecting the appropriate function. To change the memory name, type the new name in the text area and then select (return). Selecting default name. (Preset) will return the text to the This item allows the memory location to be cleared and returned to the default (preset) setting. This function allows the settings of all items to be saved at the memory location. This function allows the settings saved at the memory location to be recalled. Note that all the above functions are a momentary action. These memory names will appear in the GPI list in the memory locations. Note that if an asterisk appears in front of a memory name, this means that the sequence name it has stored is no longer in the logo sequence list. *Memory_11 This can happen if a new logo file is loaded which does not contain the name of a logo sequence in the memory. IQDLOGOPS 100403 Version 1 Issue 4 39.26

GPI Edge Trigger GPI Overview (-2 version only) The three GPI connectors on the rear panel are used for accepting GPI information (from mechanical switch contacts, relay contacts etc.) The resulting action that the unit takes may be selected from these menus. The type of input that activates the GPI function may be selected as either an edge trigger or by the change of state of any of the 3 GPI inputs. The edge trigger polarity may be selected as closed-to-open (Open) or open-to-closed (Close) for each of the GPI inputs. The function may also be disabled. To set up a function to be activated by an edge trigger. Check the Enable Edge Trig (GPE) box. Decide which GPI input to use (GPI 1, 2 or 3) and the edge trigger polarity required (GPI 1, 2, 3 = 0 or GPI 1, 2, 3 = X) where 0 = closed-to-open and X = open-to-closed. Scroll down the list of actions that may be chosen to occur when the GPI is activated and select the desired item. Setting Action OFF No action occurs Stop Stop Sequence Reverse* Sequence finish to start Forward* Sequence start to finish Reset Return to start Fade IN Fade in Logo Fade OUT Fade out Logo Memory 1 Selects Memory settings 1 to to Memory 16 Selects Memory settings 16 In this example the following setup has been selected. GPI Port Trig Polarity Action 1 0 = closed-to-open None 2 0 = closed-to-open Reverse 3 0 = closed-to-open Forward 1 X = open-to-closed Reset 2 X = open-to-closed Fade IN 3 X = open-to-closed Memory 15 IQDLOGOPS 100403 Version 1 Issue 4 39.27

GPI Edge Trigger (continued) Using the GPI Fade Settings section the following fade parameters may be set up: * Note that if the Single Cycle item in the Logo template is not enabled these functions will continuously recycle the sequence. If the Single Cycle item in the Logo template is enabled these functions will only perform a single cycle event. Maximum and Minimum Fade When a fade is GPI activated the amplitude of the logo signal at the end of the fade may be set using this function. Maximum Fade will set the maximum amplitude of the logo at the end of a Fade-In function and Minimum Fade will set the minimum amplitude of the logo at the end of a Fade-out function. The Maximum Fade range of control is from 255 to 0 in steps of 1 unit and preset is to 255. The Minimum Fade range of control is from 0 to 255 in steps of 1 unit and preset is to 0. Fade In Time and Fade Out Time (in Frames) These items allow GPI activated fade in and fade out times to be set. Both times may be adjusted separately using the scroll bars and the value will be indicated. The range of control is from 1 to 300 frames in 1 frame steps and preset is to 1 frame. IQDLOGOPS 100403 Version 1 Issue 4 39.28

GPI State Trigger To set up a function to be activated by a state trigger. Check the Enable State Trig (GPS) box. Choose the 3-bit binary code that is required to activate the function from the State 0 to State 7 items. Where O = Closed to Open and X = Open to Closed and the GPI input order is as follows: GPI-X X O 3 GPI 2 1 For example selecting State 6 X-X-O will activate the function when the state of the 3 GPI inputs changes to X (input 3 to closed), X (input 2 to closed) and O (input 1 to open) When a code has been selected scroll down the list of actions that may be chosen to occur when the GPI is activated and select the desired item. Setting Action OFF No action occurs Stop Stop Sequence Reverse* Sequence finish to start Forward* Sequence start to finish Reset Return to start Fade IN Fade in Logo Fade OUT Fade out Logo Memory 1 Selects Memory settings 1 to to Memory 16 Selects Memory settings 16 Using the GPI Fade Settings section the following fade parameters may be set up: * Note that if the Single Cycle item in the Logo template is not enabled these functions will continuously recycle the sequence. If the Single Cycle item in the Logo template is enabled these functions will only perform a single cycle event. Maximum and Minimum Fade When a fade is GPI activated the amplitude of the logo signal at the end of the fade may be set using this function. Maximum Fade will set the maximum amplitude of the logo at the end of a Fade-In function and Minimum Fade will set the minimum amplitude of the logo at the end of a Fade-out function. The Maximum Fade range of control is from 255 to 0 in steps of 1 unit and preset is to 255. The Minimum Fade range of control is from 0 to 255 in steps of 1 unit and preset is to 0. Fade In Time and Fade Out Time These items allow GPI activated fade in and fade out times to be set. Both times may be adjusted separately using the scroll bars and the value will be indicated. The range of control is from 1 to 300 frames in 1 frame steps and preset is to 1 frame. IQDLOGOPS 100403 Version 1 Issue 4 39.29

Setup This display allows various system parameters to be set. Preset Unit Selecting this item sets all adjustment functions that include a preset facility, to their preset values. EDH This section allows EDH parameters to be shown and reset. Show Stats (Statistics) When this function is enabled the information window will display the number of errors from the time the function was enabled. The elapsed time in hours, minutes and seconds is also displayed. When this function is not enabled the information window will display the Logo name the state of the Logo. Logging If a logging device is attached to the RollCall network, information about various parameters can be made available to such a device. Input Change When enabled a change of input signal condition will be available for the logging device. EDH Errors For an explanation of the abbreviations used please see the HELP section. Reset Stats (Statistics) Selecting this function will reset the EDH error count and the timer shown in the information window, to zero. Restart Unit This function allows the unit to reboot and all power-up settings to be enabled. When enabled EDH error reports will be available for the logging device. Logo File Details This item will display the date and time information embedded in the Logo file. Software Version This item shows the version of the software fitted in the module. Serial Number This item shows the serial number of the module. IQDLOGOPS 100403 Version 1 Issue 4 39.30

Defaults Default Standard In the event of a loss of input the output standard may be set to become: Auto The output standard will be the same as the input 625 The output will be in the 625 standard. Note that if this is not the same as the input standard an error message will appear in the information window and the output picture will become black. If the input fails the output will become this standard. 525 The output will be in the 525 standard. Note that if this is not the same as the input standard an error message will appear in the information window and the output picture will become black. If the input fails the output will become this standard. Default Output-On Input Fail This item allows an output picture to be selected in the event of a loss of input signal. The output picture that appears may be selected from the following list: Black The picture will become black Black & Current Logo The picture will be black with the currently selected logo; if the currently selected logo contains movement the movement will continue. Black & IP_Fail Logo The picture will be black with the selected IPF logo chosen using the IP_Fail Logo Select function below. This allows a different logo from the current logo to be chosen as the Logo that will then appear when the input signal fails. H and V Position The position of the IP_Fail logo on the screen may be set using this function. The horizontal position is set using the H_Pos item and the vertical position by using the V_Pos item. The H Position range of control is from -120 to +718 samples (525) or -138 to +710 samples (625) in steps of 2 samples and preset is to 100. The V Position range of control is from 0 to +500 (525), 0 to 600 (625) lines in steps of 2 lines and preset is to 100. Preset All Memory Names. Selecting Preset Memory Names will reset all the memory names to their default names. Clear All User memories All memories may be cleared to their default settings by selecting the Clear User Memories function. Note that if a Logo that contains movement is chosen for this function, the Logo movement will be lost under input failure conditions and the first frame of the selected sequence will be shown. IQDLOGOPS 100403 Version 1 Issue 4 39.31

Help This function will display a list of explanations for the abbreviations used in the information window and examples of some GPI setup s. IQDLOGOPS 100403 Version 1 Issue 4 39.32

Manual Revision Record Date Version No. Issue No. Change Comments 080200 1 1 First issue 200202 1 2 General corrections New issue released 120402 1 3 Now includes information for the 3A enclosure modules 100403 1 4 Power consumption added to techspec New manual issued New manual issued IQDLOGOPS 100403 Version 1 Issue 4 39.33