HST Neural Coding and Perception of Sound. Spring Cochlear Nucleus Unit Classification from Spike Trains. M.

Similar documents
Basic LabVIEW Programming Amit J Nimunkar, Sara Karle, Michele Lorenz, Emily Maslonkowski

Please feel free to download the Demo application software from analogarts.com to help you follow this seminar.

ME EN 363 ELEMENTARY INSTRUMENTATION Lab: Basic Lab Instruments and Data Acquisition

MIE 402: WORKSHOP ON DATA ACQUISITION AND SIGNAL PROCESSING Spring 2003

Experiment # 4 Counters and Logic Analyzer

Lab 1 Introduction to the Software Development Environment and Signal Sampling

INTRODUCTION (EE2499_Introduction.doc revised 1/1/18)

PRELIMINARY INFORMATION. Professional Signal Generation and Monitoring Options for RIFEforLIFE Research Equipment

Working with a Tektronix TDS 3012B Oscilloscope EE 310: ELECTRONIC CIRCUIT DESIGN I

Getting Started. Connect green audio output of SpikerBox/SpikerShield using green cable to your headphones input on iphone/ipad.

4 MHz Lock-In Amplifier

FREQUENCY COUNTERS TO 18 GHZ USING THE DATUM FREQUENCY STANDARD

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

Lab experience 1: Introduction to LabView

Virtual instruments and introduction to LabView

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

Spectrum Analyser Basics

Name: Date: Suggested Reading Chapter 7, Digital Systems, Principals and Applications; Tocci

CATHODE RAY OSCILLOSCOPE. Basic block diagrams Principle of operation Measurement of voltage, current and frequency

NanoGiant Oscilloscope/Function-Generator Program. Getting Started

CF-4700 FFT Comparator Comparator Setting Operation

Burlington County College INSTRUCTION GUIDE. for the. Hewlett Packard. FUNCTION GENERATOR Model #33120A. and. Tektronix

Getting Started with the LabVIEW Sound and Vibration Toolkit

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

Digital Delay / Pulse Generator DG535 Digital delay and pulse generator (4-channel)

SpikePac User s Guide

Advanced Skills with Oscilloscopes

Analyzing and Saving a Signal

EECS145M 2000 Midterm #1 Page 1 Derenzo

ECE 2274 Pre-Lab for Experiment Timer Chip

Exercise 5-1. Troubleshooting Techniques EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Signal flow tracing

Getting started with Spike Recorder on PC/Mac/Linux

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & 2542

2 MHz Lock-In Amplifier

Patchmaster. Elektronik. The Pulse generator. February 2013

Brain-Computer Interface (BCI)

ISCEV SINGLE CHANNEL ERG PROTOCOL DESIGN

DT9857E. Key Features: Dynamic Signal Analyzer for Sound and Vibration Analysis Expandable to 64 Channels

B2 Spice A/D Tutorial Author: B. Mealy revised: July 27, 2006

Analog Discovery Scope and Waveform Generator Edited 11/15/2016 by Eric Scotti & DGH

Timbre perception

A low noise multi electrode array system for in vitro electrophysiology. Mobius Tutorial AMPLIFIER TYPE SU-MED640

Central Software Suite

DT9834 Series High-Performance Multifunction USB Data Acquisition Modules

TechNote: MuraTool CA: 1 2/9/00. Figure 1: High contrast fringe ring mura on a microdisplay

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & General Safety Summary. Version 1.03

The Measurement Tools and What They Do

Laboratory 11. Required Components: Objectives. Introduction. Digital Displays and Logic (modified from lab text by Alciatore)

Laboratory 5: DSP - Digital Signal Processing

Advanced Test Equipment Rentals ATEC (2832)

ELECTRICAL ENGINEERING DEPARTMENT California Polytechnic State University

The most sensitive microelectrode array system for in vitro extracellular electrophysiology. Mobius Tutorial AMPLIFIER TYPE MED-A64MD1/MED-A64HE1

VFR 1 Recorder USER MANUAL

ENGR 1000, Introduction to Engineering Design

imso-104 Manual Revised July 19, 2012

4.9 BEAM BLANKING AND PULSING OPTIONS

ECE 5765 Modern Communication Fall 2005, UMD Experiment 10: PRBS Messages, Eye Patterns & Noise Simulation using PRBS

Chapter 5 Flip-Flops and Related Devices

DAT335 Music Perception and Cognition Cogswell Polytechnical College Spring Week 6 Class Notes

iworx Sample Lab Experiment AN-13: Crayfish Motor Nerve

imso-104 Manual Revised August 5, 2011

Operating Instructions

Troubleshooting Your Design with Tektronix MSO and DPO Series Oscilloscopes

Exercise 1: Muscles in Face used for Smiling and Frowning Aim: To study the EMG activity in muscles of the face that work to smile or frown.

Tektronix RSA306 USB Spectrum Analyzer

Video Streamer Modifications

NOTICE: This document is for use only at UNSW. No copies can be made of this document without the permission of the authors.

CyAn User Manual. Flow & Mass Cytometry Center Biomedical Core facility. Technion Faculty of Medicine

BTV Tuesday 21 November 2006

Experiment 7: Bit Error Rate (BER) Measurement in the Noisy Channel

TASTEPROBE Type DTP-1. Pre-amplifier for recording from contact chemosensilla INSTRUCTIONS

To fully utilize Media 100 s genlocking capability, you ll need the following equipment connected to your system:

Calibrating Measuring Microphones and Sound Sources for Acoustic Measurements with Audio Analyzer R&S UPV

SC24 Magnetic Field Cancelling System

DIGITAL ELECTRONICS: LOGIC AND CLOCKS

Revision History. SDG2000X Firmware Revision History and Update Instructions

DSP Laboratory: Analog to Digital and Digital to Analog Conversion *

Part No. ENC-LAB01 Users Manual Introduction EncoderLAB

Datasheet SHF A

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN CALIBRATION PROCEDURE FOR AUTOMATIC VIDEO CORRECTOR TEKTRONIX, MODEL 1440 (NSN )

Agilent DSO5014A Oscilloscope Tutorial

Pre-processing of revolution speed data in ArtemiS SUITE 1

ASYNCHRONOUS COUNTER CIRCUITS

1.2 General Description

EET 1131 Lab #12 - Page 1 Revised 8/10/2018

SC24 Magnetic Field Cancelling System

PQ-Box 100 Quick Start Instructions

TSG 90 PATHFINDER NTSC Signal Generator

EASY-MCS. Multichannel Scaler. Profiling Counting Rates up to 150 MHz with 15 ppm Time Resolution.

OSCILLOSCOPE AND DIGITAL MULTIMETER

VivoSense. User Manual Galvanic Skin Response (GSR) Analysis Module. VivoSense, Inc. Newport Beach, CA, USA Tel. (858) , Fax.

PHY221 Lab 1 Discovering Motion: Introduction to Logger Pro and the Motion Detector; Motion with Constant Velocity

Using the HDCV Data Acquisition Program

CPE 200L LABORATORY 3: SEQUENTIAL LOGIC CIRCUITS UNIVERSITY OF NEVADA, LAS VEGAS GOALS: BACKGROUND: SR FLIP-FLOP/LATCH

Overview. Know Your Oscilloscope. Front Panel. Rear Panel. Sharing Agilent s Resources with Engineering Educators

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

Data Acquisition Using LabVIEW

Using an oscilloscope - The Hameg 203-6

BitWise (V2.1 and later) includes features for determining AP240 settings and measuring the Single Ion Area.

Transcription:

Harvard-MIT Division of Health Sciences and Technology HST.723: Neural Coding and Perception of Sound Instructor: Bertrand Delgutte HST.723 - Neural Coding and Perception of Sound Spring 2004 Cochlear Nucleus Unit Classification from Spike Trains M. Christian Brown READ THE ENTIRE INSTRUCTIONS BEFORE PROCEEDING In this laboratory, you will classify single units recorded from the cochlear nucleus on the basis of their PST and interspike interval histogram shapes. The data were recorded from an anesthetized preparation in an experiment performed by Dr. Peter Cariani. You will be provided with a tape recording of spikes and a computer program that enables you to construct the histograms. You will work in groups for the lab, but please write separate write-ups of your results. For your lab write-up, please limit the text to 4 pages (excluding figures). I. Equipment Set-up Lab write-ups are due Friday April 4. The equipment for the lab is in Chamber 4 of the Eaton-Peabody Laboratory. A Wiring Diagram for Chamber 4 Hardware is shown below. Verify that the connections shown in solid black lines are made. Other wiring is part of the Chamber IV standard setup and should not be changed. Figure removed due to copyright considerations.

Oscilloscopes: Tektronix TDS 2014: Triggers when stimulus gate indicates presentation of a tone burst. Tektronix 2213A: Triggers when a spike is sent to Event Timer. When a waveform causes a trigger to be sent to the Event Timer, it appears with a bright hat on top of the waveform. You control this triggering by adjusting the Triggering Gain Control on the Audio Monitor. 1 V/div (Channel 1) and 2 msec/div (time base). Triggering: Ext. Audio Monitor: The Triggering Gain Control is adjusted until the Tektronix 2213A oscilloscope triggers, indicating that a spike has been sent to the Event Timer. Adjust this Gain so that you are triggering on every spike but not so high that you are triggering on the noise (Note: tape must be playing to adjust this level). This adjustment will have to be made for each unit, and sometimes for each data run on a unit. High- and Low-pass Filters may help eliminate some of the noise. Try different filtering and see how it affects the triggering and resulting histograms. Audio Volume: Adjusts gain of audio amplifier for listening to spikes via the speaker. Spike Trigger and TTL Pulse Monitor: Accepts an input signal (spikes or Stimulus Gate) and outputs a pulse when the input exceeds a certain voltage. You should not have to adjust their triggering level. Instead, control the triggering by adjusting the Triggering Gain Control of the Audio Monitor. Event Timer: Accepts stimulus onset triggering pulses on Channel 0 to start the PST histogram, and spike triggering pulses on Channel 1 to count the responses. II. Tape Insert into the Magnavox VCR the tape Master #2 CN Recordings 8/93. Rewind the tape. Reset the tape counter by pressing the Counter button, then the Reset button on the VCR. See chart on UNIT DATA page to find the tape counter locations for your units. Remember that the tape counter locations are only approximate and may be off by as much as 0010 or 0020, especially if you do a lot of starting and stopping. To be sure that you have the right unit, make sure that there are the right number of "runs" (see below), the correct amount of spontaneous activity, and if possible (i.e., for lowfrequency runs), that the tone bursts are at the correct frequency.

The tape has three simultaneously recorded channels: Channel Information 1 Spikes from single-unit micro-electrode 2 Voltage delivered to earphone to produce the tone burst * 3 Stimulus Gate (square wave going positive at the start of the tone burst) *Due to the limited bandwidth of the tape recorder, this voltage is too small to be seen for high frequencies. The data for each unit are on tape between certain tape counter readings (see UNIT DATA page). The data are arranged as follows: For each unit, there is a series of just over 100 or 200 tone bursts presented at the Start Level. Then there is a 3 sec. pause. Then there is another series at the Start Level plus the Incr. Level. There is another 3 sec. pause. This sequence continues until the Stop Level is reached. In between units, there is a "blip" on the recording before the next unit s recording starts. Tone bursts are on for 50 msec, and then off for 50 msec. All tone bursts are presented at the unit s CF. III. Software To bring up the histogram program: On the Dell computer, double click on (to open) the following: 1. Experiment VIs 2. MCB VIs 3. HST 722 Lab 4. INT & PST Histogr LabVIEW (an icon-based programming language) will start, and the program (VI or virtual instrument) "INT & PST Histogram 3 (LV3)" will start and display its Front Panel. Numbers in boxes (digital controls) can be changed by "highlighting" them by running the mouse over them and then typing new numbers. Use the following parameters: Num Sweeps: Enter either 100 or 200, depending on how many Repetitions per Level are on the UNIT DATA page for your unit. INTERVAL: Num Bins: 200, Bin Width 100 msec PST: Num Bins: 1000, Bin Width: 100 msec The x-axis (time axis) is Bin Width * Num Bins so it will be 100 msec for PST and 20 msec for INT.

The best time to start the program is during the 3-sec. pause between tone-burst runs. Start the program by pushing the run arrow (second box from left in upper left menu). A stop-sign will form that can be pressed to stop the program. The program will execute until it has received the Num Sweeps specified or until you press the stop sign (note: the data will not be saved if you press the stop sign). The Overflow bins count the number of spikes that were not within the time windows for each histogram. After the program has stopped you can enter Notes (like the unit number) in the Notes window. To Print (on the Chamber II printer): File-> Print Window. IV. Correct Triggering When a waveform causes a trigger to be sent to the event timer, it appears with a bright hat on top of the waveform on the Tektronix 2213A oscilloscope. When the triggering is set correctly, each spike should have the same waveform. False triggers, often from the triggering set too low in amplitude, are evident when some triggered waveforms look different than others. Also watch out in some recordings for a gross response, an evoked potential that is picked up by the electrode. Contamination with a gross response will make correct triggering difficult. If the contamination has lower frequencies than the spikes, the recording can be improved by high-pass filtering (adjust filters on Audio Monitor). If you are unsure how to obtain correct triggering, consult the instructor. V. Construction of histograms and write-up Play the tape for your unit to be sure that you have the right unit and the correct triggering level. Even for one unit, you may have to adjust the triggering level from run to run. For each of your units, investigate the following: 1. Spike quality: Play the tape through to get an idea of the unit's spikes. Make a judgment of the quality of the spikes of your unit ( a, b, or c on RATING page). This judgment is a measure of your confidence in the triggering. During construction of your histograms, make note of whether you have any false triggers, or whether any of your spikes were missed. 2. Classification: For each of the units assigned to your group, construct PST and interspike interval histograms. Use the lecture hand-outs to classify the units according to histogram shape. Classification is generally done at sound levels 30 db above threshold. Please specify the unit type and write a sentence or two why you chose that particular unit type. For phase locked units, if the phase locking is so strong that it obscures the PST, it is OK to write Phase-locked, but if there are some clues and you can make a guess at the unit type, it is better to write Phase-locked, probably a XXX Unit. 3. Sound Level: On one of your units that is not a Primarylike unit, study the effect of sound level on PST shape.

Questions to answer in your write-up (READ 2-5 WHEN DOING THE LAB): 1. Alongside your unit classifications in your write-up, state the anatomical cell types that are expected for each of your units. 2. There are several units that are difficult to classify. In rare cases, this is because the recording is made simultaneously from two units. Sketch a PST that might be expected if the recording is simultaneously a Chopper unit and an Onset unit. By looking at the individual spikes on the oscilloscope, how might you know that you were recording simultaneously from two different units? 3. Let s consider a special case of a unit with CF equal to 1 khz that you suspect is a Pri-notch unit, but which has such strong phase locking that the notch is obscured. How might you specify the bin width so that the notch becomes more visible? 4. From looking at your histograms, how might you determine that there were false triggers? 5. What problems do you encounter in using the runs where the tone bursts were presented at high sound levels? 6. What is the difference between a Pri-like unit and a Pri-like PST? Hint: Use your study of the effects of sound level on PST shape. 7. The recordings from your units were made with large-tipped, gelatin-filled pipette electrodes. These may record pre-potentials. If you were searching for a prepotential unit, how would you adjust the triggering to find it? When you found a prepotential unit, what type of PST histogram would you expect it to produce? 8. In the entire data set, there are about 7 Choppers, 8 Primarylike, 2 Onset, and 1 Pauser Units. Suggest the subdivision (AVCN, PVCN, or DCN) of the cochlear nucleus in which most of the units were recorded.