REPORT 258 COMMERCENTRE DRIVE, LAKE FOREST, CA 9263 Project No. G1167677 Date: June 5, 214 REPORT NO. 1167677LAX-13 TEST OF ONE WHITE FULL ON ZOOM IN MODEL NO. PLATINUM WASH 16RPRO RENDERED TO ELATION PROFESSIONAL 6122 S. EATERN AVE. COMMERCE, CA, 94 TEST: Electrical and Photometric tests as required to the IESNA test standard. STATEMENT OF LIMITATION: AUTHORIZATION: STANDARDS USED: This report must not be used by the client to claim product certification, approval, or endorsement by A2LA, NIST, or any agency of the federal government. The testing performed was authorized by signed quote number 5519256. The following American National Standards or Illuminating Engineering Society of North America Test Guides were used in part or totally to test each specimen: IESNA LM-79-28: Electrical and Photometric Measurements of Solid State Lighting DESCRIPTION OF SAMPLE: DATES OF TESTS: The client submitted one production sample of model number PLATINUM WASH 16RPRO. The sample was received by Intertek on May 29, 214, in undamaged condition and one sample was tested as received. The sample designation was LAN14529125-2. May 3, 214 This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
SUMMARY Model No.: Description: PLATINUM WASH 16RPRO White Full On Zoom In Criteria Total Lumen Output (Lumens) Total Power (W) Luminaire Efficacy (LPW) Power Factor Result 425.19 33.48.991 EQUIPMENT LIST Equipment Used LSI High Speed Mirror Goniometer Elgar Power Supply Yokogawa Power Analyzer Omega Environmental Monitor Extech Instruments Stop Watch Tape measure Model Number 644T CW1251 WT21 ibthx-w 36551 33-428 Control Last Date Calibration Number Calibrated Due Date 943 944 945 5/12/14 N/A 11/14/13 6/12/14 N/A 11/14/14 882 138 9/9/13 11/5/13 9/9/14 11/5/14 678 12/9/13 12/9/14 TEST METHODS Seasoning in Sample Orientation LED Products No seasoning was performed in accordance with IESNA LM-79. Photometric and Electrical Measurements Distribution Method A LSI Type C High Speed Model 644 Mirror Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Yokogawa Power Analyzer. Some graphics were created with Photometrics Plus software. Report No. 1167677LAX-13 2 of 5 Date: June 5, 214
RESULTS OF TEST Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) Distribution Method Intertek Sample No. LAN14529125-2 Base Orientation UP Input Input Input Input Voltage Current Power Power {Vac} (ma) (Watts) Factor 12.1 357 425.2.991 Absolute Luminous Flux (Lumens) Lumen Efficacy (Lumens Per Watt) 33.48 Intensity (Candlepower) Summary at 25 C - Candelas Maximum Candela Value:199438 Angle 5 1 15 2 25 3 35 4 45 5 55 6 65 7 75 8 85 9 22.5 45 67.5 2298 22221 2818 222 174649 185881 26483 228584 2428 28854 31917 39691 139 41 129 24 1246 412 191 2 165 419 258 22 1263 41 121 136 136 198 1 11 177 23 97 42 59 6 26 28 135 12 86 33 23 16 153 178 43 1 4 45 34 5 33 83 167 9 199438 242811 42657 1165 542 13 2 92 14 21 57 64 Report No. 1167677LAX-13 3 of 5 Date: June 5, 214
RESULTS OF TEST (cont'd) Illumination Plots Illuminance - Cone of Light Mounting Height: 1 ft. Isoillumination Plot Zonal Lumen Summary and Percentages at 25 C Zonal Lumens and Percentages at 25 C Zone -3-4 -6 6-9 -9 9-18 -18 Lumens 1416 144 14116 112.8 14228.7 5.6 % Luminaire 98.5% 98.6% 99.2%.8%.5%.% 1.% Zone -1 1-2 2-3 3-4 4-5 5-6 6-7 7-8 8-9 9-1 Lumens. 12465 1471 8.1 24.1 38.6 37.4 44.7 25.7 5.6 % Luminaire.% 87.6% 1.3%.6%.2%.3%.3%.3%.2%.% Report No. 1167677LAX-13 4 of 5 Date: June 5, 214
PICTURE (not to scale) X CONCLUSION The results tabulated in this report are representative of the actual test samples submitted for this report only. The data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not determined in this report. In Charge Of Tests: Report Reviewed By: Erik Linares Technician Lighting Division Kenda Branch Engineer Lighting Division Attachment: None Report No. 1167677LAX-13 5 of 5 Date: June 5, 214