X-Stream DSO Version 3.6 Release Notes

Similar documents
The Measurement Tools and What They Do

WAVEJET 300 SERIES OSCILLOSCOPES. New Cover to Come. Unmatched Performance, Portability, and Value

Expect to Make Waves.

WAVEJET 300 SERIES OSCILLOSCOPES. Unmatched Performance, Portability, and Value

Portable Performance for Debug and Validation

QPHY-USB3 USB3.0 Serial Data Operator s Manual

WAVERUNNER 6000A SERIES. The New Benchmark for Everyday Oscilloscopes

Thank you for purchasing a LeCroy Zi Oscilloscope Synchronization ProBus Module (Zi 8CH SYNCH module).

WAVESURFER XS SERIES. The Everyday Oscilloscope that s Easy to Use

Serial Decode I2C TEN MINUTE TUTORIAL. December 21, 2011

LeCroy Digital Oscilloscopes

FLEXRAY TRIGGER, DECODE, AND PHYSICAL LAYER TEST

MS-32 OSCILLOSCOPE MIXED SIGNAL OPTION. Add 32 Digital Channels to a 4 Channel Oscilloscope

WaveSurfer MXs. The Specs You Want The Features You Need 200 MHz to 1 GHz

Fluke 190-Series II Firmware Upgrade V11.44

Eye Doctor II Advanced Signal Integrity Tools

LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge, NY Tel: (845) Fax: (845)

SMART Trigger modes like Glitch, Window and Dropout allow you to capture precisely the events of interest.

WaveSurfer Xs-A and MXs-A Oscilloscopes

WAVEMASTER 8000A SERIES. The Ultimate Analysis Capability for Next-Generation Research

DDA-UG-E Rev E ISSUED: December 1999 ²

SDAIII-CompleteLinQ Multi-Lane Serial Data, Noise and Crosstalk Analysis

Benchmark. Oscilloscopes. for Everyday. The New. WaveRunner 6000 Series

Troubleshooting Your Design with the TDS3000C Series Oscilloscopes

Analyzing 8b/10b Encoded Signals with a Real-time Oscilloscope Real-time triggering up to 6.25 Gb/s on 8b/10b encoded data streams

WAVEEXPERT SERIES OSCILLOSCOPES WE 9000 NRO 9000 SDA 100G. The World s Fastest Oscilloscope

Quick Reference Manual

Advanced Skills with Oscilloscopes

WAVERUNNER 104XI AND 204XI

Benefits of the R&S RTO Oscilloscope's Digital Trigger. <Application Note> Products: R&S RTO Digital Oscilloscope

FlexRay Physical Layer Eye-diagram Mask Testing

SDA SDA SDA The Fastest Real Time Serial Data Analyzer

WAVERUNNER XI SERIES OSCILLOSCOPES

Jitter and Eye Fundamental & Application. Jacky Huang AE, Tektronix Taiwan

MIPI DigRF 3G and v4 Decode

DSA8300 DigitalSerialAnalyzer Printable Application Help

Instrument Firmware Release Notes

Procedure for DDR Clock Skew and Jitter Measurements

MS-32. Oscilloscope Mixed Signal Option. Add 32 Digital Channels to a 4 Channel Oscilloscope

Procedures Guide. Tektronix. HDMI Sink Instruments Differential Impedance Measurement

Operator s Manual. WaveAce 1000/2000 Series Oscilloscopes

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

Dual Link DVI Receiver Implementation

Serial Data Analyzers

Breakthrough. WaveShape breaking WAVEPRO OSCILLOSCOPES. 1 GHz 3 GHz Bandwidth Up to 48 Mpts Memory and 20 GS/s Sample Rate

LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge, NY Tel: (845) , Fax: (845) Internet:

For the SIA. Applications of Propagation Delay & Skew tool. Introduction. Theory of Operation. Propagation Delay & Skew Tool

Agilent MOI for HDMI 1.4b Cable Assembly Test Revision Jul 2012

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & 2542

RIGOL. Data Sheet. DS1000B Series Digital Oscilloscopes DS1074B, DS1104B, DS1204B. Product Overview. Easy to Use Design. Applications.

User Manual. Digital Storage Oscilloscopes Models 2534, 2540 & General Safety Summary. Version 1.03

Dual Scope Synchronization

WAVERUNNER OSCILLOSCOPES. WaveRunner DIGITAL OSCILLOSCOPES. Announcing WaveRunner 6000 Series The Dream Scope

CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium 9000A and 9000 H-Series Oscilloscopes

Reference. TDS7000 Series Digital Phosphor Oscilloscopes

Beginners How to Test DSO138mini

Debugging Memory Interfaces using Visual Trigger on Tektronix Oscilloscopes

Choosing an Oscilloscope

Digital Storage Oscilloscopes 2550 Series

Complimentary Reference Material

SPECIFICATIONS. Software Options Advanced Math and WaveShape Analysis. Standard. Math Tools. Statistics Package (WRXi-STAT)

De-embedding Gigaprobes Using Time Domain Gating with the LeCroy SPARQ

Using Manchester and NRZ Configurable Protocol Decoders

PicoScope 6407 Digitizer

SDS1000C Specifications

Operator's Manual. HDO Channel High Definition Oscilloscopes

Flip-Flops. Because of this the state of the latch may keep changing in circuits with feedback as long as the clock pulse remains active.

Agilent N6467A BroadR-Reach Compliance Test Application. Methods of Implementation

Operator's Manual WaveSurfer 510 Oscilloscopes

QPHY-HDMI2 Operator s Manual

Agilent N5431A XAUI Electrical Validation Application

2016 RIGOL TECHNOLOGIES, INC.

Operator's Manual. MS-250 Mixed Signal Oscilloscope Option

Embest DSO2300. Feature. General Description:

Application Note AN-708 Vibration Measurements with the Vibration Synchronization Module

User Manual. This document applies to firmware version 2.2 and above.

SPG700 Multiformat Reference Sync Generator Release Notes

S op o e p C on o t n rol o s L arni n n i g n g O bj b e j ctiv i e v s

Operator s Manual. WaveJet Touch Oscilloscopes

MINI PC SCOPE PCSU01. User manual. test leads software download USB cable design enclosure

Memory-Depth Requirements for Serial Data Analysis in a Real-Time Oscilloscope

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Getting Started Manual. WaveRunner 6 Zi Oscilloscopes

PicoScope 6407 Digitizer

802DN Series A DeviceNet Limit Switch Parameter List

SERIAL DATA ANALYZER. A 360 Solution for Serial Data Analysis and Jitter

Advanced Troubleshooting with Oscilloscopes 9000 Scope Hands-on Labs

DataSheet. SDS1000DL Series Digital Oscilloscope

Solutions to Embedded System Design Challenges Part II

Measurement User Guide

2 AORM Setup & View Wizard

Getting Started Manual. WaveMaster 8 Zi/Zi-A Oscilloscopes

Digital Oscilloscope Waveform Generator DC Power Supply Digital Multimeter Spectrum Analyzer Handheld Oscilloscope Probes & Accessories

ZScope M-Class Digital Storage Oscilloscope Soft Front Panel

Meeting Embedded Design Challenges with Mixed Signal Oscilloscopes

Keysight N6467A/N6467B BroadR-Reach Compliance Test Application. Methods of Implementation

SDS 1072/1074CFL / SDS 1102/1104CFL SDS 1202/1204CFL / SDS 1302/1304CFL Digital Storage Oscilloscopes 70MHz / 100MHz / 200MHz /300MHz

Agilent DSO5014A Oscilloscope Tutorial

Identifying Setup and Hold Violations with a Mixed Signal Oscilloscope APPLICATION NOTE

R&S RT-ZF20 Power Deskew Fixture User Manual

Transcription:

X-Stream DSO Version 3.6 Release Notes probe calibration and deskew fixture This release contains support for LeCroy s new TF-DSQ option. The fixture enables DC gain, offset, and skew calibration at the same probing point. Visit www.lecroy.com for more information. WaveMaster WavePro 7000 Series Deskew math function value adapted status bit offset rounding error mask displays trigger delay and false triggering INSPECT? command ADP30x probe This function now works properly on memory traces. This bit was being incorrectly set when a negative value was sent by remote control. On occasion, channel descriptor labels could display an offset value rounded up or down by a very small amount. The displayed value now matches precisely the value set in the Vertical Adjust setup dialog. Pass/fail masks are now drawn with greater precision. The occurrence of erroneous triggers when the delay is set to < -1 s in Normal trigger mode has been corrected. This remote control command incorrectly applied COMM_FORMAT settings. The problem has been eliminated. This probe now functions properly when connected to an X-Stream scope. Autozero of CP015 current probe This probe now autozeroes correctly. ISSUED: April 2004 1 of 5

WaveMaster WavePro 7000 Series DA1855 differential amplifier When PVG mode is off, the Set to Zero and Offset controls will be grayed out to clearly indicate that they don t apply. Synchronization of inputs to change offset has been improved. Occasional problem of Autozero not working properly, depending on power-up order of scope and DA1855, has been corrected. Offset settings now correctly take into account the attenuation setting of the DA1855. syntax of remote commands Formerly invalid spaces after? or ; will be ignored. internal printer expanded parameter measurements This release adds support for an optional internal printer. The number of parameters that can be measured at the same time with the XMAP and XDEV options has been increased from six to eight. 6051 combining channels on 2- channel models The functioning of the Auto-combine feature on 2- channel models has been corrected. user programmable PLL A Custom selection was added to the PLL Type menu. When selected, Custom PLL displays additional setup fields: PCI Express compliance testing LeCroy is pleased to announce its PCI Express Compliance software option for 6000A and 6020 models. This option is selectable from LeCroy s extensive Signal Type menu. Visit www.lecroy.com for more information. TJ calculation The total jitter calculation has been adjusted to account for transition density. ISSUED: April 2004 2 of 5

Bit Rate parameter This parameter now reports units correctly as bps. Find Frequency feature The functioning of this feature for signals with large amounts of DDJ has been corrected. Find Pattern Length feature Pressing this button sometimes failed to function if the pattern length had been manually adjusted. This problem has been corrected. 20 GS/s sampling on channels 2 and 4 Under some circumstances sampling was limited to 10 GS/s on channels 2 and 4, depending on channel usage for clock source. This dependency has been eliminated. mask violation locator When operating in Near X-Y mode, this feature could reliably detect mask failures, but did not always display bad bits. This problem has been corrected. scroll capability of Pj breakdown listbox Occasionally a full Pj breakdown listbox would not be scrollable. This is no longer the case. A Models Find Pattern Length feature external clock option After the Find Pattern Length button was pressed, the display could indicate 10 UI despite proper internal functioning of this feature. The correct value is now displayed. The External Clock button was incorrectly displayed in the Timebase Clock Source dialog of A models. ISSUED: April 2004 3 of 5

WaveSurfer UI in foreign languages Japanese on-line Help memory length control You now have the ability to select the language in which screen information will be displayed: French, German, Italian, Japanese, Russian, or Spanish. On-line Help in Japanese is selectable from the Welcome page of the English version of WaveSurfer Help. You can now set the memory length in the Horizontal (Timebase) dialog if you have the VL memory option installed. zoom trace and grid display mode Changing the grid mode from Single to XYSingle no longer removes displayed zoom traces. WaveSurfer ET-PMT holdoff by events Electrical Telecom option Changing the number of events no longer halts triggering. 139 Mb/s and 156 Mb/s testing capability has been added You now have the capability to limit parameter measurements to occurrences gated by a second waveform, or to a vertically or horizontally limited range. This capability enables you to exclude unwanted characteristics from your measurements. JTA2 XMAP gated and range-qualified parameter measurements ISSUED: April 2004 4 of 5

DDM ENET lbsep parameter parameter calculation with hysteresis Mode 1(transmit waveform) improvements DCD calculations Mode 1 testing The lbsep parameter did not work correctly with a non-zero offset. This problem has been corrected. For large values of hysteresis (> 2.5 div), it was possible for the window to be incorrectly set. These occurrences have been eliminated. The addition of a gain factor, improved mask resolution to prevent false failures, increased sampling rate, and improved mask aligner have enhanced the accuracy of the ENET option. Duty Cycle Distortion calculation for 100Base-T signals has been improved. The Mode 1 test routine has been made more robust by treating points individually. USB2 2004 by LeCroy Corporation setup instruction for HS Suspend Resume Reset test The displayed instruction in Step 6 of 9 called out EL_2 to EL_7. This has been corrected to EL_27. ISSUED: April 2004 5 of 5