Chroma-Q FxForce IR 12 TM

Similar documents
Chroma-Q Studio One 100 D

Chroma-Q Studio Force

Chroma-Q Studio Force V Phosphor

Chroma-Q Color Block PSU-30

Chroma-Q Inspire. User Manual. Version 1.5 August 2015, Software Version 2.1 PN:

Chroma-Q Color Split

Chroma-Q. Twin FX DMX. User Manual. Version 1.2 September 2012 PN:

Chroma-Q. Color Block 2 Plus System. User Manual. Version 2.2 October 2013, Software Version 2.2 PN:

USER INSTRUCTIONS MODEL CSI-200 COAXIAL SYSTEM INTERFACE

Page 1 of 6 FXLD618FRP2I4 LED FIXTURE Version 0.2 OWNERS MANUAL 10/04/17

LED Thunder S-150 Code 1097

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

KingWash 7QX 7x40w,Zoom 5-60degree. User manual. Please read the instructions carefully before use TABLE OF CONTENTS

Nila light fixtures are intended for indoor use only (unless clearly specified for outdoor use).

SV-LCD50. Installation and User Guide. Thin-Film Transistor (TFT) Liquid Crystal Display (LCD) Color Rear Vision Monitor. Version 1.

LED Beam Moving Head. TWIST-150LED Order No INSTRUCTION MANUAL

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

STRAND LIGHTING 200F 7-INCH TUNGSTEN LED TELEVISION FRESNEL SPECIFICATION.

HDS-21R / 41R. Owner s Manual. The World s Best 2x1 / 4x1 HDMI Switch. PureLink TM

1440/2880 HP RGB+WW+CW

HD Video Solutions HDMI SPLITTER. User Manual HDSP-2012 HDSP-2014

LED Spot 300W. Please read this user manual before your operation

Operating Manual. Automated Gear. Apollo Design Technology, Inc Fourier Drive Fort Wayne, IN USA

SR - 516D DESK TOP DMX REMOTE STATION. Version: Date: 05/16/2013

Operation Manual VMS 3.0 Video System

ALO 030 MKII. 30 Watt DMX LED scanner. User manual

192 Channel DMX Controller

CYBER PAK. User Instructions.

SUPER LED F4.7 VW Vari-White INSTRUCTION MANUAL

LED-PAR200B USER MANUAL. COLORsplash 200B

TL MEMORY CONTROL CONSOLE OWNERS MANUAL 02/17/2005. Version 0.6

Satellite Receiver. Chapter REMOTE CONTROL USING THE MENUS USING TEXT FIELDS. About Your Satellite Receiver. What you ll find in this chapter:

APOLLO DESIGN TECHNOLOGY 4130 Fourier Drive Fort Wayne, IN USA Phone: Fax:

In-Line or 75 Ohm In-Line

ProPlex Digital RGB Drive PortableMount TMB 24/7 Technical Support

PIXEL BAR 40. user manual 1.0. ELATION PIXEL BAR 40 user manual 1.0

Color mixing or White-light LED (Light Emitting Diode) ERS-style product

LED-BANK4 USER MANUAL. COLORbank 4

ArtFox Lighting. LED Beam Wash 19E. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

TL5024 MEMORY LIGHTING CONSOLE OWNERS MANUAL. Version 1.01

Operating Instructions

User Manual TL-2X1-HDVC 2x1 HDMI & VGA Switcher with Control All Rights Reserved Version: TL-2X1-HDVC_160630

PIXEL NET 4. user manual. ELATION PIXEL NET 4 user manual

Altman Lighting AP-150 RGBW Par Specification

CH1 CH2 CH3 CH4. Master /Fade CH5. 600s CH6. 60s SC1 SC2 SC4 SC3 SC5. SC6 Off/Pro. AL Fade 6 Pro. User guide

HDTV Supply Inc. reserves the right to make changes in the hardware, packaging and any accompanying documentation without prior written

Commander 384. w w w. p r o l i g h t. c o. u k U S E R M A N U A L

User Manual. 360W LED Moving Zoom KEEP THIS MANUAL FOR FUTURE NEEDS. 36pcs10W 4 in 1 RGBW LEDs

SOFT LED 4 Vari-White INSTRUCTION MANUAL

Model Number ALS-ELUM-RGB-CNTRL-1. elum RGB Controller

Altman Lighting Spectra Cyc 50 Specification

2013, 2014 Hewlett-Packard Development Company, L.P.

VLHDMIEXTFIB_2017V1.0

IMS MK2 Simple Universe Drive

COLORtube EQ Controller

USER MANUAL Table of Contents

FOTS100 User Manual. BIOPAC Systems, Inc. Opsens Inc. 42 Aero Camino, Goleta, CA Tel (805) , Fax (805)

Integrator s Guide Avalon

Image Marketing Projector 1.6

SquareLED - Aura Bar & Matrix Beam Light 100

1. Safety Instructions Installation Features Remote Control Operation Menu Operation DMX Table 5

LED Pixel Track V3 ORDERCODE 42200

USERS GUIDE MCX-HTS. HDMI to 3G SDI Converter. Manual Number:

DH551C/DH550C/DL550C Double Sided Display User Manual

Viztrac AM200 User s Guide. Page 1 of 12

HDS-21RS Owner s Manual 2 x 1 HDMI Switch with Scaling

User Manual TL-2X1-HDV 2x1 HDMI & VGA Switcher All Rights Reserved Version: TL-2X1-HDV_160630

COMPOSITE VIDEO (BNC) TO VGA VIDEO FORMAT CONVERTER AND SCALER AT-RGB110

Advanced Digital Melting Point Apparatus

MLA-XLR MIDI Line Amplifier

USER MANUAL. DV-HSW-41 HDMI 4x1 SWITCHER LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web

S30-RP LED Soft Light

BEAM MOVING HEAD YODN Lamp. 132W 2R MOVING HEAD Brightness / Stability USER MANUAL. Version 1.0 beta

Model Extend HDMI audio and video connections up to 300 feet. Add up to 8 additional receivers with a dedicated network switch

User s Manual. Digital Switch Part #: DL-HDS21 Part #: DL-HDS41

ENGLISH Antenna Distributor

User Manual. Model 1372A and 1374A HDMI Switchers. 1T-SX-632 Model 1372A 2X1 Switcher. v1.3 2x1 SWITCHER. v1.3 INPUT ENHANCE POWER

8000 Plus Series Safety Light Curtain Installation Sheet ( CD206A/ CD206B )

RemotePoint. Navigator. User s Manual VP4150

Kramer Electronics, Ltd. USER MANUAL. Models: TR-1YC, s-video Isolation Transformer TR-2YC, s-video Dual Isolation Transformers

DVDO VS4 HDMI Switch. User s Guide How to install, set up, and use your new DVDO product

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do

Owner s Manual. Backup Monitor System. LCD Monitor & CCD Color Camera

MWT-FM. Operation Manual. FM Single Channel Transmitter. man_mwtfm.

User Manual CVA3. HDMI Audio Decoder. All Rights Reserved. Version: CVA3_2016V1.0

4K Video Solutions HDMI SWITCHER. User Manual 4 1 HDSW K

OWNERS MANUAL. Revision /01/ Lightronics Inc. 509 Central Drive Virginia Beach, VA Tel

Product Identification

Owner s Manual. VL9000 Series HEADREST MONITOR SYSTEM

Instruction Manual AVT-8710 Time Base Corrector

CHROMAFLOOD 200 DATASHEET

BROTHER, BROTHER & SONS

Operating Instructions

Hex-color RGBAW+UV LED strip light

TRF STEP-DOWN TRANSFORMER USER MANUAL

ORDER CODE: EQLED65 USER MANUAL

EDITION NOTES. Document Revision

DVI Rover 700 User Guide

Headrest Monitor Directed Electronics N

Kramer Electronics, Ltd. USER MANUAL. Model: VA-14. 4x1 Balanced Audio Mixer

Transcription:

Chroma-Q FxForce IR 12 TM User Manual Version 1.1 OCTOBER 2018, Software Version 2.1 Part Number: (CHFXIR12, CHFXIR12W) Model: (621-3500, -621-3510)

Warranty Statement Chroma-Q warrants to the original purchaser, with proof of purchase, that its delivered products shall be free from defects in material and workmanship under normal use for a period of 12 months from date of shipment. Chroma-Q will repair, or at its option, provide an equivalent item or replace, the defective product during the stated warranty period. This warranty applies only to the repair or replacement of the product and only when the product is properly handled, installed and maintained according to Chroma-Q instructions. This warranty excludes defects resulting from improper handling, storage, installation, acts of God, fire, vandalism or civil disturbances. Purchaser must notify Chroma-Q in writing within 14 days of noticing the defect. This warranty excludes field labor or service charges related to the repair or replacement of the product. The warranty contained herein shall not extend to any finished goods or spare parts from which any serial number has been removed or which have been damaged or rendered defective (a) as a result of normal wear and tear, willful or accidental damage, negligence, misuse or abuse; (b) due to water or moisture, lightning, windstorm, abnormal voltage, harmonic distortion, dust, dirt, corrosion or other external causes; (c) by operation outside the specifications contained in the user documentation; (d) by the use of spare parts not manufactured or sold by Chroma-Q or by the connection or integration of other equipment or software not approved by Chroma-Q unless the Customer provides acceptable proof to Chroma-Q that the defect or damage was not caused by the above; (e) by modification, repair or service by anyone other than Chroma-Q, who has not applied for and been approved by Chroma-Q to do such modification, repair or service unless the Customer provides acceptable proof to Chroma-Q that the defect or damage was not caused by the above; (f) due to procedures, deviating from procedures specified by Chroma-Q or (g) due to failure to store, install, test, commission, maintain, operate or use finished goods and spare parts in a safe and reasonable manner and in accordance with Chroma-Q s instructions (h) by repair or replacement of engines without factory training. The warranty contained herein shall not apply to finished goods or spare parts which are sold as is, as second-hand, as used, as demo or under similar qualifications or to Consumables ( Consumables is defined as any part(s) of goods or part(s) for use with goods, which part(s) of goods or part(s) for use with goods are consumed during the operation of the goods and which part(s) of goods or part(s) for use with goods require replacement from time to time by a user such as, but not limited to, light bulbs). The warranty contained herein shall not apply, unless the total purchase price for the defective finished goods or spare parts has been paid by the due date for payment. The warranty contained herein applies only to the original purchaser and are not assignable or transferable to any subsequent purchaser or end-user. This warranty is subject to the shipment of the goods, within the warranty period, to the Chroma-Q warranty returns department, by the purchaser, at the purchaser s expense. If no fault is found, Chroma-Q will charge the purchaser for the subsequent return of the goods. Chroma-Q reserves the right to change the warranty period without prior notice and without incurring obligation and expressly disclaims all warranties not stated in this limited warranty. Chroma-Q FxForce IR TM 12 User Manual 1 P/N: 621-0708_Version 1.1

Disclaimer The information contained herein is offered in good faith and is believed to be accurate. However, because conditions and methods of use of our products are beyond our control, this information should not be used in substitution for customer's tests to ensure that Chroma-Q products are safe, effective, and fully satisfactory for the intended end use. Suggestions of use shall not be taken as inducements to infringe any patent. Chroma-Q sole warranty is that the product will meet the sales specifications in effect at the time of shipment. Your exclusive remedy for breach of such warranty is limited to refund of purchase price or replacement of any product shown to be other than as warranted. Chroma-Q reserves the right to change or make alteration to devices and their functionality without notice due to our on going research and development. The Chroma-Q FxForce range has been designed specifically for the lighting industry. Regular maintenance should be performed to ensure that the products perform well in the entertainment environment. If you experience any difficulties with any Chroma-Q products please contact your selling dealer. If your selling dealer is unable to help please contact support@chroma-q.com. If the selling dealer is unable to satisfy your servicing needs, please contact the following, for full factory service: Outside North America: North America: Tel: +44 (0)1494 446000 Tel: 416-255-9494 Fax: +44 (0)1494 461024 Fax: 416-255-3514 support@chroma-q.com support@chroma-q.com For further information please visit the Chroma-Q website at. Chroma-Q and FxForce IR 12 are trademarks, for more information on this visit www.chromaq.com/trademarks. The rights and ownership of all trademarks are recognised. Important Notice: As per the requirements in the Occupational Safety and Health Administration standards for product approval, please refer to the OSHA web pages http://www.osha.gov/dts/otpca/nrtl/ for information on the list of Nationally Recognized Testing Laboratories (NRTLs) and the scope of recognition. Chroma-Q FxForce IR TM 12 User Manual 2 P/N: 621-0708_Version 1.1

Table of Contents Product overview... 4 Unpacking the units... 4 Cabling... 4 Mounting... 5 Optical Accessories... 5 Control... 5 DMX Protocol... 9 Thermal Performance... 9 Troubleshooting... 9 Technical specifications... 10 Drawings... 11 Maintenance... 11 Chroma-Q FxForce IR TM 12 User Manual 3 P/N: 621-0708_Version 1.1

Product overview The Chroma-Q FxForce TM IR 12 is an Infra-red lighting fixture which utilises the same core innovative LED technologies found in the Color Force range to provide a brilliant IR light ideal for infrared filming and night mode video. Successfully used in the Film & TV market, it can be used in many other applications including image capturing photography. Designed for practicality, the unit is equipped with a manual control mode, colour touch screen interface and a range of optional accessories. The FxForce IR 12 features two light engines with 24 Infra-red LEDs each for a total of 48 Infra-red LEDs. Equipped with a built-in power supply unit, the fixture can operate as a standalone unit or controlled remotely through the ANSI E1.11 USITT DMX 512-A protocol. The control modes incorporate intensity control in remote DMX or standalone manual operation. The product's robust anodised extruded aluminium construction houses a discreet cable management system with enhanced protection around the lenses. The adjustable yoke assembly features a hidden quick release fixing for fast and easy tilt adjustment. Unpacking the units The package includes the FxForce IR 12 fixture, power connector (EU)/power cord (US) and a Quick Start Guide. We recommend that you keep the original packaging in case the item needs to be returned. Cabling FxForce IR 12 power input and through connections are via 2 powercon connectors. The DMX control data input and through connections from an external control console are via 2 XLR 5-pin connectors. The chassis are ground bonded. Note: The maximum number of fixtures running off a single power input cable is 10 at 120V AC or 20 at 240V AC. Please refer to ANSI and AWG standards for the maximum data and power cable lengths. XLR 5-pin Cable: Pin# Function 1 Ground (Screen) 2 Data Minus 3 Data Plus 4 Spare Data Minus 5 Spare Data Plus Chroma-Q FxForce IR TM 12 User Manual 4 P/N: 621-0708_Version 1.1

Power Cable: International Colour Code North American Colour Code Connections Green and Yellow Green Earth (E) Ground (Green) Blue White Neutral (N) Neutral (Silver) Brown Black Live (L) Hot (Gold) Important Notice: The use of an opto-splitter for DMX signal distribution is highly recommended when several fixture units are not plugged into the same power source. Mounting The FxForce IR 12 fixture is built with a yoke assembly for floor, wall and truss mounting applications. The yoke assembly features a hidden quick release fixing for fast and easy tilt adjustment. Note: Secure the fixture with a safety bond. A provision for a fixing hold is built into the yoke. Optical Accessories Slide-in optical accessories are available to adjust the beam angle of the fixture to suit a wide range of applications. 2 accessory slots and a swivel plate are included at the front and side of the fixture to hold and lock these slide-in accessories: cyc and border light lens, lightbank kit, egg crate louver, top hat, half top hat, barn door and diffuser box attachment accessories. Control The FxForce IR 12 fixture can operate as a standalone unit or be controlled remotely via ANSI E1.11 USITT DMX512-A protocol. The control functions can be accessed through the LCD display at the rear of the fixture with 4 push buttons. Push button operation: Exit: back to previous menu Enter: Save the setting Up arrow: increase (+) the mode level or value Down arrow: decrease (-) the mode level or value Power-Up Display: On power-up and home position, the LCD display shows the Main Menu screen with the model name, software version, the DMX address, current assigned mode and the number of assigned channels. Display Mode: The LCD is backlit when you access the menus. This will turn off when left undisturbed for 5 seconds. Control Modes: Mode Display C Description No. h 1 Dim1x 1 1 DMX channel directly affecting the intensity of all the LEDs. 11 Look sel 1 1 DMX channel assigned to select from all the Looks stored in Look Store. 12 Mastr The fixture is set as the Master unit. StndAlon 13 Slave StndAlon The fixture is set as the Slave unit. Units set as slave follow the control modes set with the Master unit. Manual Use of the Up and Down buttons to increase and decrease the intensity of all the LEDs in standalone operation. Chroma-Q FxForce IR TM 12 User Manual 5 P/N: 621-0708_Version 1.1

Control Menu 1. From the Main Menu, press the Up or Down buttons to scroll through the control menu options. 2. Press the Enter button to select a control menu option. 3. Use the Up and Down buttons to scroll through the settings available. 4. Press the Enter button for 2 seconds to select and save a setting. The screen goes back to the Main Menu. The Exit button can be pressed at any time and the screen goes back to the previous menu. Main Menu / DMX Address To set the DMX start address, 1. Press Enter 2. Press Up or Down to adjust the DMX start address 3. Press Enter for 2 seconds to save The display goes back to the Main Menu. Control Mode The fixture can be set to operate in 2 DMX controlled modes and 3 standalone modes. Mode Name Ch Description 1 Dim1x 1 All LEDs 11 Look sel 1 Look Select 12 Mastr StndAlon Standalone Master 13 Slave StndAlon Standalone Master Manual Manual Chroma-Q FxForce IR TM 12 User Manual 6 P/N: 621-0708_Version 1.1

Manual: In this mode, the intensity level Intensity can be set and adjusted in standalone operation. To adjust the Intensity levels, 1. In Manual mode, press Enter once, 00% level will flash. 2. Press Up or Down to adjust the value. 3. Press Enter for 2 seconds to save. The display goes back to the Main Menu. When DMX is Lost If DMX is not detected various output options can be selected: Option Function Off will snap to off Hold will hold the last valid DMX state Look 1-31 will snap to the Look of your choice Look Store In this mode, 31 looks can be stored for standalone operation. To replay a Look in standalone operation, 1. From the Main Menu, scroll and select Look Store. 2. In Look Store, scroll and select the desired look. 3. Press Enter for 2 seconds to save. To replay a Look with a DMX console, 1. From the Main Menu, scroll and select Look sel. 2. Press Enter for 2 seconds to save. 3. Use the DMX console with the assigned channel to playback the various looks stored. (1-31 looks in 1 single channel) Note: DMX has priority over internal Looks Looks can be recorded to the internal flash memory by users and will be preserved on power down. However, looks will be returned to default setting if Reset is performed. There are two ways to record a look: Simple, create and save a look with a DMX console: 1. Set the fixture to the desired Control Mode. 2. Use a DMX console to adjust channel levels and create the desired look or effect. 3. From the Main Menu, scroll and select Look Store. 4. Scroll and select the Look Store number. 5. Press Enter for 2 seconds to save the Look. Advanced, create and save a look in standalone (DMX is unplugged) 1. From the Main Menu, scroll and select Look Store. 2. Scroll and select a Look Store number. 3. Press Enter to access the memory data. The data is presented as two numbers separated by a letter c. The number to the left of the c is the channel number and to the right is the channel level. Pressing Up/Down up to the far end will show the Mode at which the selected Look was programmed. To edit the Mode of a selected Look: 1. From the Main Menu, scroll and select Look Store. 2. Scroll and select a Look Store number. 3. Press Enter to access the memory data. Chroma-Q FxForce IR TM 12 User Manual 7 P/N: 621-0708_Version 1.1

4. Press the Up/Down buttons up to the far end until the Control Mode number is shown then press Enter. 5. Press the Up/Down buttons to adjust the Mode number. 6. Press Enter to toggle back to the channel numbers. To edit the channel numbers and levels of a selected Look: 1. From the Main Menu, scroll and select Look Store. 2. Scroll and select a Look Store number. 3. Press Enter to access the memory data. 4. Press the Up/Down buttons and select the channel number. 5. To edit the channel level, press Enter and use the Up/Down buttons to adjust the level (shown as 0-255). 6. Press Enter to toggle back to the channel number. When the desired effect is created press Enter for 2 seconds to save the edited Look. Technical In this mode, Frequency settings of the fixture can be changed. Software updates for the LED engines can be uploaded. Frequency: The fixture has four frequency settings available to allow for the LED scan rate to be synchronised with the video camera and avoid a flickering effect. 600 1200 2400 4800 Upload Engines: Software updates for the LED engines can be uploaded to the fixture from the Chroma-Q Uploader: To set the fixture for engine upload, 1. From the Main Menu, scroll and select Technical. 2. In Technical, select Upload Engines. 3. Press Enter, and the display shows Ready. Proceed to execute uploading: 1. Connect an XLR 5-pin cable from the Uploader to the unit. 2. Power-up the Uploader - display shows the file name, and Ready. 3. On the Uploader, press the GO button once to execute the uploading - red indicator light on the GO button blinks. The Uploader display shows a simulated arrow moving from left to right indicating the uploading process. All the LEDs of the fixture lights up (low intensity) to indicate completion of a successful upload and the Uploader display shows DONE. 4. Power-cycle the unit. (See Quick Start Guide of the Chroma-Q Uploader) Fan Speed The fixture is built with an internal fan with 4 speed options to regulate noise levels and the cooling process. Live High velocity Live when Light Live mode is activated when the fixture LEDs are on Studio Low velocity Quiet Off Chroma-Q FxForce IR TM 12 User Manual 8 P/N: 621-0708_Version 1.1

Reset to Default The fixture can be reset to factory default settings: DMX address 001 Control Mode Dim1x When DMX is Lost Hold Looks 01 Frequency 600 Fan Speed Live DMX Protocol DMX Personality FxForce IR 12 V2.1 Control Mode 1 Dim1x [1ch] Control Mode 11 Look sel [1ch] Channel 1 All LEDs Look 1-31 Total 1 DMX channel 1 DMX channel Thermal Performance The FxForce IR 12 fixture is equipped with an internal fan to drive the internal cooling system. When the internal temperature of the fixture exceeds 75ºC the output is reduced for automatic protection. This happens on rare and extreme conditions when ambient temperature is over 35ºC or the internal fans are blocked or damaged. The airflow to and from the fan must not be constricted to maintain the maximum operating capacity. Troubleshooting Troubleshooting is a process of elimination. First, rule out the other field factors (i.e. bad connections, faulty cables and power supplies). For technical support and/or parts, please contact your selling dealer or the offices listed in this manual. Symptom Possible Cause Solution Fixture does not respond to DMX control. Noise from fixture unit. Low LED output. Set to wrong or different DMX address. Bad cable connecting DMX control and fixture. Bad in/through connection between adjacent fixtures. Fan malfunction. Internal temperature is over the limit. Fan is not working. Check DMX address and Mode settings. Check/replace DMX cable. Check fans. Check Fan Control mode. Check the fans and airflow - to and from the internal fan. Check area ventilation. Chroma-Q FxForce IR TM 12 User Manual 9 P/N: 621-0708_Version 1.1

Technical specifications Product Code CHFXIR12 Net Dimensions(Without 335mm x 190mm x 219mm / 13.2" x 7.5" x 8.6" Fixings) - Width x Height x Depth Net Weight (Without 4kgs / 9lbs Fixings) Shipping Dimensions - 432mm x 343mm x 279mm / 17 x 13.5 x 11 Width x Height x Depth Shipping Weight 6kgs / 13lbs Power & Connections Power Supply Built-in Power Input Rating 100-240V AC 50-60Hz 160VA Power Factor 0.9 Power Consumption 110W (maximum intensity); 6W (stand-by) Typical Power & Current Measurements done with all LEDs at maximum intensity. Measurements made at nominal voltage. Allow for a deviation of +/- 10%. Power Connectors In/Out powercon Data Connectors In/Out XLR 5-pin Control Protocol ANSI E1.11 USITT DMX 512-A Cooling System Forced - 1 fan Operating Temperature 0 C to 40 C Construction Black anodised aluminium extrusion Colour Black Built-In Hardware Quick release lever for tilt adjustment IP Rating IP20 Approvals CISPR 22 :2006/EN55022 :2006 & CISPR 24 :1997/EN55024 :1998, ICES- 003 :2004 & FCC Part 15 Subpart B: 2007, CSA C22. No. 166-M1983:R2008 UL 1573:2003 Control & Photometric LED Engines 2 LEDs Per Engine 24 IR LEDs Total LEDs 48 IR LEDs Control Modes 1 channel Dim1x, 1 channel Look Select, Master Standalone, Slave Standalone, Manual Lamp Life L70 at 50,000 hours Chroma-Q FxForce IR TM 12 User Manual 10 P/N: 621-0708_Version 1.1

Drawings Maintenance With care, the FxForce IR 12 requires little maintenance. However, as the unit is likely to be used in a stage environment we recommend periodical internal inspection and cleaning of any resulting dust and cracked oil residue. Do not spray liquids on the front or rear panel. If the front enclosure requires cleaning, wipe with a mild detergent on a damp cloth. Chroma-Q FxForce IR TM 12 User Manual 11 P/N: 621-0708_Version 1.1