SyG 02 and SyG 02-SB

Similar documents
DATA SHEET. Synchronisers, FAS-113DG ANSI code 25

SINAMICS G130 / G150. Line harmonics filter. Operating Instructions 05/2010 SINAMICS

CURRENT INJECTION RELAY TESTER CR-100. ( Code P60212 (770081) ) INSTRUCTIONS MANUAL ( M / 05A ) (c) CIRCUTOR S.A.

EA63-7D. Generator Automatic Voltage Regulator Operation Manual. Self Excited Automatic Voltage Regulator

Operating Instructions 07/2007 Edition. SINAMICS G130/G150 Line harmonics filter. sinamics

MATE3 Owner s Manual Addendum

EG4015. Digital Generator Governor Controller User Manual

Self Excited Automatic Voltage Regulator For Generator Compatible with Marathon SE350* Operation Manual

Operating Manual (Edition 04/2004) sinamics. Line Reactors SINAMICS G130

Warner Photoscanner MCS-500 Series LED Photoelectric Control

KHT 1000C HV-Probe Calibrator. Instruction Manual

EA350. Generator Automatic Voltage Regulator Operation Manual

DLP200M 2 Relay Module for Heating and Cooling Plants

Capacitance Limit Detection nivotester FTC 420/421/422

DLP600M 6+1 Relay Module for Heating and Cooling Plants

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

KRF EMC Filters Installation, Operation and Maintenance Manual

SINAMICS G130. dv/dt filter plus Voltage Peak Limiter. Operating Instructions 03/2013 SINAMICS

Contents. Instruction Manual T-Rex Page 2 of 16 Release 1.01

SQM40/41 Actuators for air and gas dampers

Figure 1: Device components

Level Measurement silometer FMC 420, FMC 423

PRINCIPLES AND APPLICATIONS

Instruction Manual. 2.4G Digital Wireless Four Channel Transmitter System RVS-554W. Reverse With Confidence 1

EGM Einthoven Goldberger Module Type 701

82384R. SPM-A Synchronizer. Installation, Operation, and Calibration Manual. Manual 82384R

AK-PVE4 Operating Instructions. Measuring of norm signals in wall-type units. Performance:

System 2000 System 2000 HLK relay insert. 1 Safety instructions. 2 Device components. 3 Function. Order No. : Operating instructions

Guide for installers. METTLER TOLEDO MultiRange System solution analog Ex1. Hazardous area. Safe area

Electronic M.O.P Card. Instruction Manual Model D

EVC300i. Generator Automatic Voltage Regulator Operation Manual

Owner s Manual. multiswitch Firmware-Version 1.06 OS- Version 1.02

PLC Control Unit for a CSM-E Electrical Compact Clean Steam Generator

CAMTO LTD. Arc detecting system DC/AC

Model Number Structure

ER-100 Eurorack 8 Channel Stereo, Transformer Balanced Out Summing Mixer User Manual

Master Time Clock MTC Users Manual

Multi-functional safety relay modules PROTECT SRB-E

MICROMASTER Encoder Module

RD RACK MOUNT DIMMER OWNERS MANUAL VERSION /09/2011

Atlas SCR. User Guide. Thyristor and Triac Analyser Model SCR100

multi-function meters

User s Manual Model WF100 Extension Cable for EXA100

Industriefunkuhren. Technical Manual. IRIG-B Generator-Module for analogue / digital Signals of Type: IRIG-B / IEEE C / AFNOR NF S87-500

Product Manual (Revision U, 10/2007) Original Instructions. SPM-A Synchronizer. Installation and Operation Manual

VHF + UHF Amplified HDTV Antenna Model OA8000 & OA8001 Installation Instructions Reception Frequencies

Cryoelectronics. MS-FLL User s Manual. Mr. SQUID Flux-Locked Loop. STAR Cryoelectronics 25 Bisbee Court, Suite A Santa Fe, NM U. S. A.

Utility Amplifier GA6A Model

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Assembly. Front view. LEDs. Parametrization interface. Power Bus

EVC600i. Generator Automatic Voltage Regulator Operation Manual

Wired Troubleshooting Manual

REGO Start&Go USER MANUAL

NetterVibrotron SRF. Operating Instructions for. Series SRF. These operating instructions apply to. Netter Static Adjustable Frequency Control

TriLIN Program Utility TPU_ TriLIN Programming Manual

User Guide UD51. Second encoder small option module for Unidrive. Part Number: Issue Number: 5.

Catalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web:

Model R177M and R177S Baseband Switch

Installation Manual SaVi Note Underwater LED Light

INSTRUCTION & OPERATION MANUAL. MODEL MMW-05 (5kW) MUROMACHI MICROWAVE FIXATION SYSTEM

WIRING INSTRUCTIONS CROP-LINK Drip Installation

TRIPLETT. PairMaster. Lan Cable Test Set. Instruction Manual

Catalogue. BUDAPEST 1064 RÓZSA UTCA 90. TEL. (+36-1) FAX. (+36-1) Web:

Trusted 40 Channel 120 Vac Digital Input FTA

LIGHT AIR SWITCH. User Manual and Troubleshooting Guide WIRELESS LIGHTING MODULE ACKNOWLEDGEMENTS SAFETY WARNINGS EQUIPMENT DESCRIPTION

Website: Tel: ADDRESS: 6475 Las Positas Rd. Livermore, CA Item No. E5B/E5S Installation Guide

OPERATING MANUAL. DMX LED Current Dimmer 5004A-EP Mk2

1.5mm amplitude at 10 to 55Hz frequency in each X, Y, Z direction for 2 hours 500m/s² (approx. 50G) in each X, Y, Z direction for 3 times

Standard signal metering in wall-mounting case

ALM-6813/6812 INSTALLATION AND PROGRAMMING MANUAL

Junior Max (JR Max ) Controller

Aspect 2 Circuit Digital Scene Control

Noise Detector ND-1 Operating Manual

CR-R880-BL: Indoor/Outdoor Proximity Reader with 10cm (4in) read range

17 19 PROFESSIONAL LCD COLOUR MONITOR ART

User Guide. Centrex Recording Interface

CONTACT-DUO-PROFILE. Contact-Duo-Profile overview

INSTRUCTION MANUAL. Controller CLT-500 / RG-500

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS UP TO 300 cm. of width

User Instructions. 16 SCB Sync Station.

CATHODE CURRENT DISTRIBUTION CONTROL DEVICE

TRF STEP-DOWN TRANSFORMER USER MANUAL

Installation Guide VL-MV10. Model No.

Lt DELTA USA, Inc

USER MANUAL. WARNING Read the instructions before using the machine. EN (Original Instruction) / 1704

45LM Series Modules. Features. Specifications. Plug-in Logic and Display Modules for Q45 Series Photoelectric Sensors

Electronic lubrication control unit

Kuhnke Technical Data. Contact Details

Safety Information. Camera System. If you back up while looking only at the monitor, you may cause damage or injury. Always back up slowly.

OPERATING MANUAL. DMX / DSI / DALI Dekoder 3004B-H Mk2

Digital Ratio Controller

CLASS 300 EQUIPMENT BE3-25A AUTO-SYNCHRONIZER (Single Phase)

DAAB DB409 INSTRUCTION MANUAL FOR THE VFD-EL FREQUENCY CONVERTER. For the DAAB EP104 automatic control system with software version 4.

Sensor module. Safety instructions. Function Correct use. Product characteristics. Structure of the device. Operation. Ref.No.

Heating thermostat Series AMHs B Operating Instructions 11.06/

Linear flow controls VFC Linear flow controls with actuator IFC

Instruction Manual. 7" Wireless Camera System with Wired Side Camera Inputs RVS-355W. Reverse With Confidence 1

SCREEN WINCH SYSTEM INSTALLATION MANUAL FOR SCREENS FROM 300 cm. UP TO 450 cm. of width

OPERATING MANUAL. DMX512 to DALI Dekoder 7044A-H Mk4

32 Channel CPCI Board User Manual

Transcription:

Heinzmann GmbH & Co. KG Engine & Turbine Controls Am Haselbach 1 D-79677 Schönau (Schwarzwald) Germany Phone +49 7673 8208-0 Fax +49 7673 8208-188 E-mail info@heinzmann.com www.heinzmann.com V.A.T. No.: DE145551926 HEINZMANN Electronic Speed Governors Synchronizing Unit SyG 02 and SyG 02-SB Copyright 2004 by Heinzmann GmbH & Co KG. All rights reserved. This document may not be reproduced or handed on to third parties. Manual E 82 002-e / 11-05

Warning Read this entire manual and all other publications appertaining to the work to be performed before installing, operating or servicing your equipment. Practice all plant and safety instructions and precautions. Danger Failure to follow instructions may result in personal injury and/or damage to property. HEINZMANN will refuse all liability for injury or damage which results from not following instructions Danger! High Voltage Please note before commissioning the installation: Before starting to install any equipment, the installation must have been switched dead! Be sure to use cable shieldings and power supply connections meeting the requirements of the European Directive concerning EMI. Danger Check the functionality of the existing protection and monitoring systems. Danger To prevent damages to the equipment and personal injuries, it is imperative that the following monitoring and protection systems have been installed: Overspeed protection acting independently of the speed governor Overtemperature protection HEINZMANN will refuse all liability for damage which results from missing or insufficiently working overspeed protection Generator installation will in addition require: Overcurrent protection Protection against faulty synchronization due to excessive frequency, voltage or phase differences Reverse power protection Overspeeding can be caused by: Failure of the voltage supply Failure of the actuator, the control unit or of any accessory device Sluggish and blocking linkage

Warning Electronically controlled injection (MVC) will in addition require to observe the following: With Common Rail systems a separate mechanical flow limiter must be provided for each injector pipe. With Pump-Pipe-Nozzle (PPN) and Pump Nozzle (PNE) systems fuel release may be enabled only by the movement of control piston of the solenoid valve. This is to inhibit fuel from being delivered to the injection nozzle in case of seizure of the control piston. Warning The examples, data and any other information in this manual are intended exclusively as instruction aids and should not be used in any particular application without independent testing and verification by the person making the application. Danger Independent testing and verification are especially important in any application in which malfunction might result in personal injury or damage to property. HEINZMANN make no warranties, express or implied, that the examples, data, or other information in this volume are free of error, that they are consistent with industry standards, or that they will meet the requirements for any particular application. HEINZMANN expressly disclaim the implied warranties of merchantability and of fitness for any particular purpose, even if HEINZMANN have been advised of a particular purpose and even if a particular purpose is indicated in the manual. HEINZMANN also disclaim all liability for direct, indirect, incidental or consequential damages that result from any use of the examples, data, or other information contained in this manual. HEINZMANN make no warranties for the conception and engineering of the technical installation as a whole. This is the responsibility of the user and of his planning staff and specialists. It is also their responsibility to verify whether the performance features of our devices will meet the intended purposes. The user is also responsible for correct commissioning of the total installation.

Contents Contents Page 1 Safety Instructions and Related Symbols... 1 1.1 Basic Safety Measures for Normal Operation... 2 1.2 Basic Safety Measures for Servicing and Maintenance... 2 1.3 Before Putting an Installation into Service after Maintenance and Repair Works... 3 2 Application... 4 3 Method of Operation... 5 4 Block Diagram of the Synchronizer... 6 5 Technical Data... 7 6 Electrical Details... 8 6.1 Specification... 8 6.2 Electrical Connections... 9 7 Dimensional Drawing... 10 8 Setting Up Procedure... 11 8.1 Initial... 11 8.2 Adjusting the Synchronizer... 11 8.3 Note for Maintenance Work at the Plant... 12 9 Special Applications... 13 9.1 Synchronization of Island Sets to the Mains... 13 9.2 Switch-off of Synchronizer... 13 9.3 Stand-by Synchronization... 14 10 Ordering Specifications... 15 11 Wiring Diagrams... 16 12 Trouble Shooting... 17 13 Figure List... 19 14 Order Specifications for Manuals... 20 Synchronizing Unit SyG 02

1 Safety Instructions and Related Symbols 1 Safety Instructions and Related Symbols This publication offers wherever necessary practical safety instructions to indicate inevitable residual risks when operating the engine. These residual risks imply dangers to persons product and engine environment. The symbols used in this publication are in the first place intended to direct your attention to the safety instructions! Warning This symbol is to indicate that there may exist dangers to the engine, to the material and to the environment. Danger This symbol is to indicate that there may exist dangers to persons. (Danger to life, personal injury)) Danger! High Voltage This symbol is to indicate that there exist particular danger due to electrical high tension. (Mortal danger). Note This symbol does not refer to any safety instructions but offers important notes for better understanding the functions that are being discussed. They should by all means be observed and practiced. The respective text is printed in italics. The primary issue of these safety instructions is to prevent personal injuries! Whenever some safety instruction is preceded by a warning triangle labelled Danger this is to indicate that it is not possible to definitely exclude the presence of danger to persons, engine, material and/or environment. If, however, some safety instruction is preceded by the warning triangle labelled Caution this will indicate that danger of life or personal injury is not involved. The symbols used in the text do not supersede the safety instructions. So please do not skip the respective texts but read them thoroughly! Synchronizing Unit SyG 02 1

1 Safety Instructions and Related Symbols In this publication the Table of Contents is preceded by diverse instructions that among other things serve to ensure safety of operation. It is absolutely imperative that these hints be read and understood before commissioning or servicing the installation. 1.1 Basic Safety Measures for Normal Operation The installation may be operated only by authorized persons who have been duly trained and who are fully acquainted with the operating instructions so that they are capable of working in accordance with them. Before turning the installation on please verify and make sure that - only authorized persons are present within the working range of the engine; - nobody will be in danger of suffering injuries by starting the engine. Before starting the engine always check the installation for visible damages and make sure it is not put into operation unless it is in perfect condition. On detecting any faults please inform your superior immediately! Before starting the engine remove any unnecessary material and/or objects from the working range of the installation/engine. Before starting the engine check and make sure that all safety devices are working properly! 1.2 Basic Safety Measures for Servicing and Maintenance Before performing any maintenance or repair work make sure the working area of the engine has been closed to unauthorized persons. Put on a sign warning that maintenance or repair work is being done. Before performing any maintenance or repair work switch off the master switch of the power supply and secure it by a padlock! The key must be kept by the person performing the maintenance and repair works. Before performing any maintenance and repair work make sure that all parts of engine to be touched have cooled down to ambient temperature and are dead! Refasten loose connections! Replace at once any damaged lines and/or cables! Keep the cabinet always closed. Access should be permitted only to authorized persons having a key or tools. 2 Synchronizing Unit SyG 02

1 Safety Instructions and Related Symbols Never use a water hose to clean cabinets or other casings of electric equipment! 1.3 Before Putting an Installation into Service after Maintenance and Repair Works Check on all slackened screw connections to have been tightened again! Make sure the control linkage has been reattached and all cables have been reconnected. Make sure all safety devices of the installation are in perfect order and are working properly! Synchronizing Unit SyG 02 3

2 Application 2 Application The HEINZMANN synchronizer was designed to be used for the synchronization of a single generator set to island sets, or the whole island to the mains in connection with any of the electronic governors produced by the HEINZMANN company. The synchronizer compares the frequency and the phase at zero crossing between two generators or between generator and the mains respectively and brings both up to the same values. The measuring voltage will be checked at zero crossing and if the difference is more than 80 volt, the connection will be supressed. Warning The real generator voltage has to be adjusted before synchronizing with the voltage governor of the generator or a voltage adjusting unit. When the values agree the synchronization switch in the device is closed. With the closing of the synchronization switch the main contactor resp. (in the case of insufficient switching capacity) an auxiliary contactor may be closed; as an alternative, a standby indication is activated, and the generator set can any time be connected to the mains manually or automatically. With mains operation, synchronization presupposes appropriate load sharing resp. load adjustment which can be obtained by speed droop or by zero speed droop in conjunction with a load sharing device. The different methods of load sharing are described in our manual E 80 003. 4 Synchronizing Unit SyG 02

3 Method of Operation 3 Method of Operation The synchronizer SyG 02 measures the frequency, phase angle and voltage between two generators, or between a generator and the mains. Measurement extends to three phases. From the circuits for comparison of frequency and phase, the integrator and the output amplifier receive a signal corresponding to the actual deviation. This signal is handed on to the control unit of the electronic speed governor of the prime mover. Measuring voltage comparison is used as an additional synchronization window; it will be operative only within the range of the zero crossings and have no effect upon the generator voltage. The light emitting diode Voltage will signal that the voltage difference is within the synchronization window. generator setpoint (mains) allowed phase error voltage difference for synchronization window Figure 1: Synchronization Window When the frequency and phase errors have been reduced to zero the contactor relay is energised with an adjustable time delay between 0.5 and 5 secs., this delay ensures bumpless loading of the generator. When the relay closes there is an automatic reset function which will operate with a 0.5-1 sec. delay, and the synchronizer is then disconnected from the governor. However, the supply voltage of the synchronizer must not be switched off by no means. This would cause a stationary speed change. The voltage supply of the synchronizer has to be connected Note - to the generator bar for synchronization of a single aggregate, - to the middle bar (consumer bar) when synchronizing with several aggregates. Synchronizing Unit SyG 02 5

4 Block Diagram of the Synchronizer 4 Block Diagram of the Synchronizer Generator Mains Switch S1 230 V AC 115 V AC 1 2 4 5 3 6 10 11 12 Isolation Transformer Isolation Transformer Delay time Angle Isolation Transformer Power supply Frequency comparison Phase angle comparison Voltage comparison +10 V -5 V + Gain Synchronising time Integrator Output amplifier Reset circuit Synchronizer relay 16 16A 18 17 17 15 14 9 7 8 to governor Figure 2: Block Diagramm of the Synchronizer 6 Synchronizing Unit SyG 02

5 Technical Data 5 Technical Data Supply voltage 115 or 230 V AC ±10 % Power input Generator voltage range Generator frequency range Contact load of the synchronization switch approx. 10 VA 115-440 V AC phase to phase 50/60 Hz (special type up to 400 Hz) maximum 8 A at 250 V AC Phase angle adjustable ±2 to ±15 Voltage detection range (synchronization window) Synchronization time Synchronization puls Output signal Maximal frequency correction Switching delay adjustable Temperature range Weight 80 V AC approx. 3 to 15 secs. dependent upon installation approx. 1 sec. 1 to 9 V DC ±2 Hz 0.5 up to 5 sec. -40 C up to +80 C approx. 2.6 kg Synchronizing Unit SyG 02 7

6 Electrical Details 6 Electrical Details 6.1 Specification 6.1.1 Wiring diagram is described on next page. 6.1.2 The synchronizer can be connected to all HEINZMANN speed governors. For connection details refer to wiring diagram on next page. 6.1.3 The voltage inputs of the synchronizer which are necessary for measuring the frequency, the phase and the voltage appear in order terminals 1 (L1), 2 (L2), 3 (L3) for the generator to be synchronized and in order terminals 4 (L1), 5 (L2), 6 (L3) for the setpoint connections, mains or bus bar. Warning Pay attention to correct wiring. 6.1.4 The synchronizer power supply is delivered from a 115 V AC (terminal 10 and 11) or 230 V AC (terminal 10 and 12). If the voltage of the generator between Phase and Neutral is equal to one of these values,the synchronizer s power supply may be taken from one generator Phase and Neutral. 6.1.5 The contactor relay rating can be at 115 V AC up to 250 V AC max. 8 A resistive load, or at 24 V DC max. 1 A, resistive load. It might be used as an opener (NC, terminals 7 and 8) or as a closing contact (NO, terminals 8 and 9). 6.1.6 For governor connections use terminal 16 and 17 (16 = signal, 17 = 0 volt). The connection cable has to be screened Terminal 16A is described later with the terminals 14, 15 and 17, 18 in chapter special applications. 8 Synchronizing Unit SyG 02

6 Electrical Details 6.2 Electrical Connections Incoming Generator (Slave) N L1 At connection of the synchronizer with a control unit with EMV or of the series E 2000 the screen on the synchronizer side has to be connected on a earth terminal directly outside the housing. KG 1-06 F / KG 2-06 F Synchronizer relay max. 8 A, 250 V AC blue brown SyG 02 Connection for governor E 1 and E 2 L2 L3 KG 6-04 up to KG 94-04 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 16A17 17 18 A 3 B 3 Connection for governor E 6 up to E 94 Synchronizer on / off (off when switch closed) S1 115 V AC During maintenance work the switch S1 has to be opened to prevent any voltage at the synchronizer and the generator! 230 V AC Attention! Supply voltage has to be connected all the time during operation. This voltage has to come from the generator for generator synchronizer and from the bus bar when used for synchronizing to the mains. Conntactor supply Generator on / off Bus (Master) Cable size: N L1 L2 L3 Accessory inputs SyG - KG 2 x 1 mm² with screen Rest 1,5 mm² Figure 3: Electrical Connections Synchronizing Unit SyG 02 9

7 Dimensional Drawing 7 Dimensional Drawing 90 4 38 4,2 228 130 160 30 90 150 210 240 Figure 4: Dimensional Drawing of the Synchronizer 10 Synchronizing Unit SyG 02

8 Setting Up Procedure 8 Setting Up Procedure 8.1 Initial Before adjusting the synchronization unit, the voltages of the generators must be set to the same values. Furthermore, the reactive load sharing must be ensured, e.g., by paralleling the generator brushes. If necessary, supplementary information can be obtained from the generator manufacturers. With links connected between terminals 14 and 15 and terminals 17 and 18 resp. on the synchronizer, start the generators and supply voltage to synchronizer (refer to electrical connection). Set and adjust engine to the synchronous speed, i.e. 50 Hz (refer to the governor manuals). Stop the generator sets and remove the link between terminal 14 and 15. 8.2 Adjusting the Synchronizer HEINZMANN GmbH+Co. Speed Govenor Company Phasenwinkel Phase angle Angle de Phase Am Haselbach 1 79677 Schönau Germany Tel:(07673)8208-0 Fax:(07673)8208-88 0 5 10 15 Syn.-Zeit Syn. Time Temps de Syn. 10 5 0 0 Gain 5 10 Schaltverzögerung Delay Delai de Coupure 0 sek sec 5 Frequenz Frequency Frequence Phase Spannung Voltage Tension Figure 5: Adjusting Potentiometers and LED s When the frequency, phase and voltage of both generators are equal, the synchronizer relay will close with an adjustable delay time from 0.5 to 5 secs. For all adjustments, the link between terminals 17 and 18 must remain to inhibit the above synchronizing relay. However, the frequency, phase and voltage indicators will remain working to assist with adjusting. 8.2.1 Set the required phase angle. The smaller the phase angle the longer the synchronization time. 8.2.2 Set the required synchronizer relay switching delay (usually 0.5-1.5 secs.). 8.2.3 Turn synchronization time and gain anti-clockwise to stop. Synchronizing Unit SyG 02 11

8 Setting Up Procedure 8.2.4 Start the generator sets. 8.2.5 Turn gain clockwise until engine is unstable then turn back anti-clockwise until engine is stable. 8.2.6 Turn synchronisation time clockwise until engine is unstable then turn back anticlockwise until engine is stable. 8.2.7 Once the above setting have been made, check that the generator synchronizes correctly by either disturbing the actuator fuel lever or by temporarily linking terminals 14 and 15. If the generator does not have an acceptable synchronizing time then re-adjust 8.2.1 up to 8.2.6 to optain the optimum settings. Danger! High Voltage Before closing the mains breaker for the first time it has to be checked that the voltage over the breaker is near zero volt. This is to insure that there will be no phase mismatch over the mains breaker. Take care of high voltages! When satisfied with above synchronization, then remove link between terminals 17 and 18 which will allow the mains breaker to operate. 8.3 Note for Maintenance Work at the Plant During maintenance work, the switch S1 shown in fig. 2 and fig. 3 has to be open! This is to prevent any voltage coming via the synchronizer to the generator side of the mains breaker. 12 Synchronizing Unit SyG 02

9 Special Applications 9 Special Applications 9.1 Synchronization of Island Sets to the Mains When synchronizing a group of generators to the mains, the mains synchronizing unit must act upon the load sharing device. Normally, this will be resistive load sharing using the load measuring unit LMG 10. In this case, the load measuring unit LMG 10 has to be connected to terminal 16A instead of terminal 16! The mains synchronization unit is to be connected to only one of the load measuring units LMG 10. The mains synchronization unit will then act via the connection lines upon the the aggregate resp. the aggregates that are currently working. For this, please refer to manual E 02 001-e (Load Measuring Unit LMG 10). 13 14 15 16 16A 17 17 18 SyG 02 to terminal 22 of LMG 03 to terminal 23 of LMG 03 Figure 6: Connection for Group Synchronizer 9.2 Switch-off of Synchronizer In isolated parallel operation, when there are no voltages yet applied to the bus bar the synchronization units have to be switched off. It is only after connecting the first aggregate manually to the bus bar that the synchronization units of the other aggregates may be activated (otherwise there might be undefined speed oscillations around the synchronization frequency). Disconnection is executed by a switch. There will be no signal to the governor, and the synchronization relay will not close. Synchronizing Unit SyG 02 13

9 Special Applications 13 14 15 16 16A 17 17 18 SyG 02 open switch: synchronizer switched-on closed switch : synchronizer switched-off Figure 7: Switch-off of Synchronizer It is recommended to have this circuitry always provided and to enable the synchronization unit only immediately before the desired synchronization. 9.3 Stand-by Synchronization For stand-by synchronization the aggregate is brought up to the desired frequency and phase position and then kept in this state. After this, connection to the mains can be executed manually or automatically any time. 13 14 15 16 16A 17 17 18 SyG 02 open switch: automatic system closed switch: no breaker closure Figure 8: Stand-by Synchronization 14 Synchronizing Unit SyG 02

10 Ordering Specifications 10 Ordering Specifications Spezification of the standard type SyG 02 For rapid start up service generator sets (no-break generator sets) a modified unit is necessary. Its specification is: SyG 02 - SB Synchronizing Unit SyG 02 15

11 Wiring Diagrams 11 Wiring Diagrams For different applications sketches are available, which can be ordered if required. E Sk 502.01 Generator sets with automatic synchronization and effective load sharing E Sk 503.00 Generator sets with automatic synchronization and effective load sharing, island and mains operation (basic load) E Sk 504.00 Generator sets with automatic synchronization and effective load sharing, island and mains operation (load setting for mains operation) E Sk 505.00 Generator sets with automatic synchronization and effective load sharing, island and mains operation (controlled mains supply) E Sk 507.00 Generator sets with automatic synchronization and effective load sharing, load anticipation unit, island and basic load mains operation E Sk 508.00 Generator sets with automatic synchronization and basic load mains operation 16 Synchronizing Unit SyG 02

12 Trouble Shooting 12 Trouble Shooting Symptom Probable Cause Synchronizer does not correct frequency no input voltage on terminals 1, 2, 3 or 4, 5,6 jumper between 14-15 input voltage too low no AC power to terminals 10-11 (115 V AC) or 10-12 (220 V AC) engine speed more than ± 2 Hz difference with bus Before synchronizing frequency unstable no input voltage on terminals 4, 5, 6, and nevertheless jumper between 14-15 open (synchronizer in operation mode) During synchronizing frequency unstable synchronizer gain wrong adjusted Engine governor unstable make jumper between 14-15 and observe governor connection governor/synchronizer no screened wire used or screen wrong connected Synchronizing Unit SyG 02 17

12 Trouble Shooting Symptom Probable Cause Synchronizer correct frequency, but no breaker closure occurs connection between 17-18 check if relay on synchronizer works, all 3 LED s must be on adjustment synchronizing time and time delay far too long speed governor unstable Generator frequency runs always high or low connections 16 and 17 reversed or input phases incorrectly wired connection generator and bus reversed After synchronization engine not taking power speed offset adjust wrong enginge speed too low setpoint for load measuring unit LMG 10 to low 18 Synchronizing Unit SyG 02

13 Figure List 13 Figure List Figure 1: Synchronization Window... 5 Figure 2: Block Diagramm of the Synchronizer... 6 Figure 3: Electrical Connections... 9 Figure 4: Dimensional Drawing of the Synchronizer... 10 Figure 5: Adjusting Potentiometers and LED s... 11 Figure 6: Connection for Group Synchronizer... 13 Figure 7: Switch-off of Synchronizer... 14 Figure 8: Stand-by Synchronization... 14 Synchronizing Unit SyG 02 19

14 Order Specifications for Manuals 14 Order Specifications for Manuals There is no charge for our technical manuals ordered in reasonable quantities. Order the necessary manuals on our speed governors from your nearest HEINZMANN location. (Please click on HEINZMANN location to see the list of our subsidiaries and agents in the world). Please include the following information: your name, the name and address of your company (you can simply include your business card), the address where you want the manuals sent (if different from above), the number(s) (as on front page bottom right) and title(s) of the desired manual(s), or the technical data of your HEINZMANN equipment, the quantity you want. You can directly use the following fax-form for ordering one or several manuals. Most of the manuals are available as acrobat PDF-files, too. On request they can be send via e-mail. We solicit comments about the content and the presentation of our publications. Please, send your comments to: HEINZMANN GmbH & Co. KG Service Department Am Haselbach 1 D-79677 Schönau Germany 20 Synchronizing Unit SyG 02

Fax Reply Order for HEINZMANN technical manuals Fax-Hotline +49 7673 8208 194 Please send me the following manuals: Quantity No. of the manual Title Please send me your new sales documentation about ( ) the HEINZMANN Analogue Governors Application:... ( ) the HEINZMANN Digital Governors Application:... ( ) the HEINZMANN Gas Engine Equipment Application:... Company... Contact Person... Department... Adress... Country/Code/Town... Phone... Fax... E-Mail... Activity... Date...