Technical Information RIA45

Similar documents
RIA45. Technical Information. Panel meter Digital panel meter with control unit for monitoring and visualizing analog measured values

RMA42. Technical Information

RIA46. Technical Information. Field meter Digital field meter with control unit for monitoring and visualizing analog measured values

Process transmitter RMA422

Process Transmitter RMA 422

Capacitance Level Measurement Electronic insert FEC 12

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

Level Measurement silometer FMC 420, FMC 423

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

02/11/2015

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

PSI-MOS-RS232/FO 850 E Serial to Fiber Converter

Thermocouple and RTD Modules for Compact FieldPoint

SITRANS F flowmeters SITRANS F M. Transmitter MAG 6000 I/6000 I Ex d e 4/43

DMP 335 DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. Pressure Transmitter. Industrial

LAUREL ELECTRONICS, INC.

ACT20X Series for hazardous area applications Section A

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0,35 % FSO. Nominal pressure

Signal conditioning instruments

LXM23DU10M3X motion servo drive - Lexium 23 - single phase V - 1 kw - I/O

Capacitance Limit Detection nivotester FTC 420/421/422

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

DMP 331 DMP 331. Industrial Pressure Transmitter. for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial. tri-matic.

Assembly. Front view. LEDs. Parametrization interface. Power Bus

MINI MCR-SL-F-UI-NC. Frequency transducers. Data sheet. 1 Description

Wall-/Pipe-Mount Level Indicator

Display Information Type Backlit blue on white STN Type

LONWORKS Fibre Optic Converter

Fibre Optic Modem ODW-622

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

LMP 331 LMP 331. Screw-In Transmitter with piezoresistive Stainless Steel Sensor

Datasheet - SRB301LC 24VAC/DC

Magnetic field sensor for pneumatic cylinders BIM-IKT-Y1X

Digital Input Modules for Compact FieldPoint

TEK-LCD 7801A. NEMA 4X Loop-Powered Feet and Inches Level Meter. ACCESSORIES. Technology Solutions

DS 210. Electronic Pressure Switch. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Hybrid Chart Recorder 250 mm (10")

Inductive sensor. 2-wire, analog output BI8-M18-LI-EXI

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

DS 200 P DS 200 P. Electronic Pressure Switch with Flush Process Connection

DMP 331i / DMP 333i LMP 331 i

Fibre optic router for TP/FT-10 LRW-112PP

User Manual M1. Thermocouple type K, B, S, N, E, T, R, L, J. Technical features:

Level Measurement Point level measurement - RF Capacitance switches

TFRN Industrial RTD temperature sensor. CombiTemp TM

Gamma instabus. Technical product information

Magnetic Field Sensor for pneumatic cylinders BIM-IKT-Y1X

Inductive sensor BI1.5-EG08K-Y1

ODW-621. RS-232 Point-to-point applications

Soft starter, 66 A, V AC, Us= 24 V DC, with control unit, Frame size N. Function Soft starter for three-phase loads, with control unit

Generator protection relay

FIELD MOUNTED RATE TOTALISER MODEL 202D

5700 series Displays PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY

DMP 339. Pressure Transmitter. with G ¼" flush diaphragm. Pressure Transmitter. Industrial. accuracy according to IEC 60770: 0.

9 Control Equipment. Measurement- and Control Equipment Series 8214, 8218

FTS84/85 Feature Application Field. Temperature & Humidity / Flow Measuring Specialist. Monitor gas and flow for industrial process

DMP 335. Industrial Pressure Transmitter. Welded, Dry Stainless Steel Sensor. accuracy according to IEC 60770: 0.5 % FSO.

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

TFR5 Room or outdoor temperature sensor. CombiTemp TM

- special pressure ranges - variety of electrical and mechanical. Characteristics. - other versions on request

Actuators IC 20, IC 40

Inductive sensor NI3-EG08K-Y1-H1341

DS 400 P. Intelligent Electronic Pressure Switch in Hygienic Stainless Steel Ball Housing. on hygienic process connections

LONWORKS Fibre Optic Router

TeSys contactors. Model d. Type of contactor LC1- LC1- LC1- LC1- LC1-D115 & D09 D18 D25 D38 D40 D50 D95 LC1-D150 DT20 & DT25 DT32 & DT40

263 Series LED Bargraph Indicator and Controllers

Inductive sensor NI10-M18-Y1X-H1141

High performance circuit breakers

DCP100 Digital Control Programmer Specifications

Datasheet - SRB-E-201ST

Ordering details. Approval. Classification

PRINCIPLES AND APPLICATIONS

DMP 331i DMP 333i. Precision Pressure Transmitter. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Technical data. General specifications. Indicators/operating means

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

Multifunction devices

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

LMP 305. Slimline Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Inductive sensor With analog output BI15-M30-LI-EXI

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

SCALE & WEIGHT DISPLAYS

Flow Measurement SITRANS F M

4-in-1 Motor Controller CAN

Fibre Optic Modem ODW-611

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Micro-DCI 53ML5100 Manual Loader

TFRH Hygienic RTD temperature sensor. CombiTemp TM

Technical Information Gamma Modulator FHG65 Synchronizer FHG66

DMK 457 DMK 457. Pressure Transmitter for Shipbuilding and Offshore

Magnecraft General Purpose Relays 750R Series DPDT and 3DPT, 10 A

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Eddy Current Probe System

Signal conditioning instruments

45 Hz to 500 Hz 1.0% Hz to 1 khz 2.0% + 3. Accuracy 0.09% + 2. Range / resolution. Range / resolution. Accuracy 1% + 2

Supply voltage 230 V AC Service button 1. Power connector Light track contacts Service LED 1, red

Transcription:

TI00141R/09/EN/05.16 71315968 Products Solutions Services Technical Information RIA45 Panel meter Panel meter with control unit for monitoring and visualizing measured values Application Plant and apparatus engineering and construction Control rooms and cabinets Laboratories Process recording and supervision Process control Signal adjustment and signal conversion WHG compliant limit signal transmitter Min./max. value saved 1 or 2 calculated values One linearization table with 32 points for each calculated value 1 or 2 analog outputs Digital status output (open collector) Operation using 3 keys SIL2 approval (optional) Your benefits 5-digit, 7-segment backlit LC display User-configurable dot matrix display range for bar graph, units and tag name 1 or 2 universal inputs 2 relays (optional)

Function and system design Application Analog in 2 Analog in 1 1 Example for "differential pressure" application A0010350 The RIA45 panel meter powers the transmitter and processes analog signals from transmitters, particularly from the area of process instrumentation. These signals are monitored, evaluated, calculated, saved, separated, linked, converted and displayed. The signals, intermediate values and the results of calculations and analysis are transmitted by digital or analog means. Measuring system Mathematics functions The RIA45 is a process transmitter, which is controlled by a microcontroller, and exhibits a display, analog inputs for process and status signals, analog and digital outputs, as well as an interface for configuration. Connected sensors (e.g. temperature, pressure) can be powered by the integrated transmitter power supply system. The signals to be measured are converted from analog to digital signals, processed digitally in the device, and then converted from digital to analog signals and made available to the various outputs. All measured values, and values calculated in any way, are available as a signal source for the display, all outputs, relays and the interface. It is possible to make multiple use of the signals and results (e.g. a signal source as an analog output signal and limit value for a relay). The following mathematics functions are available in RIA45: Sum Difference Multiplication Mean Linearization Linearization function Up to 32 user-definable points are available in the device per calculated value to linearize the input, e.g. for tank linearization. In the case of the two-channel device (option), mathematics channel M2 can be used to linearize mathematics channel M1. Linearization is also available in the FieldCare configuration software. 2 Endress+Hauser

Input Measured variable Measuring ranges Number of inputs Update time Galvanic isolation Current, voltage, resistance, resistance thermometer, thermocouples Current: 0/4 to 20 ma +10% overrange Short-circuit current: max. 150 ma Load: 10 Ω Voltage: 0 to 10 V, 2 to 10 V, 0 to 5 V, 0 to 1 V, 1 to 5 V, ±1 V, ±10 V, ±30 V, ±100 mv Max. permitted input voltage: Voltage 1 V: ±35 V Voltage < 1 V: ±12 V Input impedance: > 1 000 kω Resistance: 30 to 3 000 Ω Resistance thermometer: Pt100 as per IEC60751, GOST, JIS1604 Pt500 and Pt1000 as per IEC60751 Cu100, Cu50, Pt50, Pt46, Cu53 as per GOST Ni100, Ni1000 as per DIN 43760 Thermocouple types: Typ J, K, T, N, B, S, R as per IEC60584 Typ U as per DIN 43710 Typ L as per DIN 43710, GOST Typ C, D as per ASTM E998 One or two universal inputs 200 ms Towards all other circuits Output Output signal One or two analog outputs, galvanically isolated Current/voltage output Current output: 0/4 to 20 ma Overrange up to 22 ma Voltage: 0 to 10 V, 2 to 10 V, 0 to 5 V, 1 to 5 V Overrange: up to 11 V, short-circuit proof, I max < 25 ma HART HART signals are not affected Loop power supply Open-circuit voltage: 24 V DC (+15% /-5%) Ex version: > 14 V at 22 ma Non-hazardous operation: > 16 V at 22 ma Maximum 30 ma short-circuit-proof and overload-proof Galvanically isolated from system and outputs Switching output Open Collector for monitoring of the device state and alarm notification. The OC output is closed in normal state. In error state, the OC output is opened. Endress+Hauser 3

I max = 200 ma U max = 28 V U on/max = 2 V at 200 ma Galvanic isolation towards all other circuits; test voltage 500 V Relay output Relay output for limit function Relay contact Maximum contact burden DC Maximum contact burden AC Minimum contact load Galvanic isolation towards all other circuits Switching cycles Changeover 30 V / 3 A (permanent state, without destruction of the input) 250 V / 3 A (permanent state, without destruction of the input) 500 mw (12 V/10 ma) Test voltage 1500 V AC > 1 million Power supply Terminal assignment RTD I LPS 2-W LPS 4-W x2 x4 x5 x6 x7 x8 4-W 3-W 2-W TC U<=1V U>1V x7 x8 Typ J,K,T,N... 0/4...20mA ±100mV...±1V x4 x8 x7 x8 R12 R11 R13 R22 R21 R23 x1 x2 0...10V 0/1...5V ±10V ±30V x4 x8 4...20mA Analog Out 4...20mA CH1 CH2 x1 x2 x4 x8 0/4...20mA x3 21 22 23 24 x8 25 26 27 28 11 12 13 14 15 16 17 18 L + N - 2 Terminal assignment of the panel meter (relays (terminals Rx1-Rx3) and channel 2 (terminals 21-28 and O25/O26) optional) A0010228 Supply voltage Power consumption Wide-area power supply unit 24 to 230 V AC/DC (-20 % / +10 %) 50/60 Hz Max. 21.5 VA / 6.9 W 4 Endress+Hauser

Connection data interface Commubox FXA291 PC USB interface Connection: 4-pin connector Transmission protocol: FieldCare Transmission rate: 38,400 Baud Interface cable TXU10-AC PC USB interface Connection: 4-pin connection Transmission protocol: FieldCare Delivery scope: Interface cable incl. FieldCare Device Setup DVD with all Comm DTMs and Device DTMs Performance characteristics Reference operating conditions Maximum measured error Power supply: 230 V AC, 50/60 Hz Ambient temperature: 25 C (77 F) ± 5 C (9 F) Humidity: 20 %...60 % rel. humidity Universal input: Accuracy Input: Range: Maximum measured error of measuring range (omr): Current 0 to 20 ma, 0 to 5 ma, 4 to 20 ma; Overrange: up to 22 ma ±0.05% Voltage 1 V 0 to 10 V, 2 to 10 V, 0 to 5 V, 1 to 5 V, 0 to 1 V, ±1 V, ±10 V, ±30 V ±0.1% Voltage < 1 V ±100 mv ±0.05% Resistance measurement 30 to 3000 Ω 4-wire: ± (0.10% omr + 0.8 Ω) 3-wire: ± (0.10% omr + 1.6 Ω) 2-wire: ± (0.10% omr + 3 Ω) RTD Pt100, 200 to 850 C ( 328 to 1 562 F) (IEC60751, α=0.00385) Pt100, 200 to 850 C ( 328 to 1 562 F) (JIS1604, w=1.391) Pt100, 200 to 649 C ( 328 to 1 200 F) (GOST, α=0.003916) Pt500, 200 to 850 C ( 328 to 1 562 F) (IEC60751, α=0.00385) Pt1000, 200 to 600 C ( 328 to 1 112 F) (IEC60751, α=0.00385) 4-wire: ± (0.10% omr + 0.3 K (0.54 F)) 3-wire: ± (0.10% omr + 0.8 K (1.44 F)) 2-wire: ± (0.10% omr + 1.5 K (2.7 F)) Cu100, 200 to 200 C ( 328 to 392 F) (GOST, w=1.428) Cu50, 200 to 200 C ( 328 to 392 F) (GOST, w=1.428) Pt50, 200 to 1 100 C ( 328 to 2 012 F) (GOST, w=1.391) Pt46, 200 to 850 C ( 328 to 1 562 F) (GOST, w=1.391) Ni100, 60 to 250 C ( 76 to 482 F) (DIN43760, α=0.00617) Ni1000, 60 to 250 C ( 76 to 482 F) (DIN43760, α=0.00617) 4-wire: ± (0.10% omr + 0.3 K (0.54 F)) 3-wire: ± (0.10% omr + 0.8 K (1.44 F)) 2-wire: ± (0.10% omr + 1.5 K (2.7 F)) Thermocouples Cu53, 50 to 200 C ( 58 to 392 F) (GOST, w=1.426) Typ J (Fe-CuNi), 210 to 1 200 C ( 346 to 2 192 F) (IEC60584) Typ K (NiCr-Ni), 200 to 1 372 C ( 328 to 2 502 F) (IEC60584) 4-wire: ± (0.10% omr + 0.3 K (0.54 F)) 3-wire: ± (0.10% omr + 0.8 K (1.44 F)) 2-wire: ± (0.10% omr + 1.5 K (2.7 F)) ± (0.10% omr +0.5 K (0.9 F)) from 100 C ( 148 F) ± (0.10% omr +0.5 K (0.9 F)) from 130 C ( 202 F) Endress+Hauser 5

Accuracy Input: Range: Maximum measured error of measuring range (omr): Typ T (Cu-CuNi), 270 to 400 C ( 454 to 752 F) (IEC60584) Typ N (NiCrSi-NiSi), 270 to 1 300 C ( 454 to 2 372 F) (IEC60584) Typ L (Fe-CuNi), 200 to 900 C ( 328 to 1 652 F) (DIN43710, GOST) Typ D (W3Re/W25Re), 0 to 2 495 C (32 to 4 523 F) (ASTME998) Typ C (W5Re/W26Re), 0 to 2 320 C (32 to 4 208 F) (ASTME998) Typ B (Pt30Rh-Pt6Rh), 0 to 1 820 C (32 to 3 308 F) (IEC60584) Typ S (Pt10Rh-Pt), 50 to 1 768 C ( 58 to 3 214 F) (IEC60584) Typ U (Cu-CuNi), 200 to 600 C ( 328 to 1 112 F) (DIN 43710) ± (0.10% omr +0.5 K (0.9 F)) from 200 C ( 328 F) ± (0.10% omr +0.5 K (0.9 F)) from 100 C ( 148 F) ± (0.10% omr +0.5 K (0.9 F)) from 100 C ( 148 F) ± (0.15% omr +1.5 K (2.7 F)) from 500 C (932 F) ± (0.15% omr +1.5 K (2.7 F)) from 500 C (932 F) ± (0.15% omr +1.5 K (2.7 F)) from 600 C (1 112 F) ± (0.15% omr +3.5 K (6.3 F)) für 50 to 100 C ( 58 to 212 F) ± (0.15% omr +1.5 K (2.7 F)) from 100 C (212 F) ± (0.15% omr +1.5 K (2.7 F)) from 100 C (212 F) AD converter resolution Temperature drift 16 bit Temperature drift: 0.01%/K (0.1%/18 F) omr 0.02%/ K (0.2%/18 F) omr for Cu100, Cu50, Cu53, Pt50 and Pt46 Analog output: Current 0/4 to 20 ma, overrange bis 22 ma ±0.05% of measuring range Max. load Max. inductivity 500 Ω 10 mh Max. capacity 10 µf Voltage Resolution Temperature drift Galvanic isolation Max. ripple 0 to 10 V, 2 to 10 V 0 to 5 V, 1 to 5 V Overrange: up to 11 V, shortcircuit proof, I max < 25 ma Max. ripple 13 bit 0.01%/K (0.1%/18 F) of measuring range Testing voltage of 500 V towards all other circuits 10 mvpp at 500 Ω, frequency < 50 khz ±0.05% of measuring range ±0.1 % of measuring range 10 mvpp at 1 000 Ω, frequency < 50 khz Installation Mounting location Orientation Panel, cutout 92 x 45 mm (3.62 x 1.77 in) (see 'Mechanical construction'). Max. panel thickness 26 mm (1 in). No restrictions. The orientation is determined by the readability of the display. Max. viewing angle range +/- 45 from the central display axis in every direction. 6 Endress+Hauser

Environment Ambient temperature range NOTICE The life-time of the display is shortened when operated in the upper temperature range. To avoid heat accumulation, always make sure the device is sufficiently cooled. Non-Ex/Ex devices: 20 to 60 C ( 4 to 140 F) UL devices: 20 to 50 C ( 4 to 122 F) Storage temperature Operating height Climate class Degree of protection 40 to 85 C ( 40 to 185 F) < 2 000 m (6 560 ft) above MSL As per IEC 60654-1, Klasse B2 Front IP 65 / NEMA 4 (not evaluated by UL) Device casing/rear side IP 20 Electrical safety Protection class I, overvoltage category II, pollution degree 2 Condensation Electromagnetic compatibility (EMC) Front: permitted Device casing: not permitted Interference immunity: To IEC 61326 industrial environments / NAMUR NE 21 Interference emissions: To IEC 61326 Class A Endress+Hauser 7

Mechanical construction Design, dimensions 43.9 (1.73) 41.9 (1.65) 48 (1.89) 16.7 118.6 (4.67) (0.66) 151.8 (5.98) 175 (6.89) 96 (3.78) 1 90.9 (3.56) 88.9 (3.50) 3 Dimensions of the panel meter in mm (in) 1 Distance piece for terminals (Ex option) A0010208 Weight Approximately 300 g (10.6 oz) Material Housing: plastic PC-GF10 Terminals Spring terminals Relay / auxiliary voltage terminals Input / output terminals 0.2 to 2.5 mm 2 (24 to 12 AWG) 0.2 to 1.5 mm 2 (24 to 16 AWG) Panel thickness Max. 26 mm (1 in) 8 Endress+Hauser

Operability Local operation 4 1 5 6 7 2 8 3 9 4 Display of the panel meter 1 Channel display: 1: analog input 1; 2: analog input 2; 1M: calculated value 1; 2M: calculated value 2 2 Dot matrix display for TAG, bar graph and unit 3 Limit value indicators in the bar graph 4 "Operation locked" indicator 5 Green LED; measuring device operational 6 Red LED; error/alarm 7 Yellow LED; status of relay 1 8 Yellow LED; status of relay 2 9 Minimum/maximum value indicator A0010223 Display 5-digit, 7-segment backlit LC display Dot matrix for text/bar graph Display range -99999 to +99999 for measured values Signaling Setup security locking (lock) Measuring range overshoot/undershoot 2 x status relay (only if relay option was selected) Operating elements 3 keys: -, +, E Remote operation Configuration The device can be configured with the PC software or on site using the operating keys. FieldCare Device Setup is delivered together with the Commubox FXA291 or TXU10-AC (see Accessories ) or can be downloaded free of charge from www.endress.com. Interface 4-pin socket for the connection with a PC via Commubox FXA291 or TXU10-AC interface cable (see 'Accessories') Endress+Hauser 9

Certificates and approvals CE mark EAC mark Ex approval Overfill prevention Functional safety Marine approvals UL Other standards and guidelines The measuring system meets the legal requirements of the applicable EC guidelines. These are listed in the corresponding EC Declaration of Conformity together with the standards applied. Endress +Hauser confirms successful testing of the device by affixing to it the CE mark. The product meets the legal requirements of the EEU guidelines. The manufacturer confirms the successful testing of the product by affixing the EAC mark. Information about currently available Ex versions (ATEX, FM, CSA, etc.) can be supplied by your E+H Sales Center on request. All explosion protection data are given in a separate documentation which is available upon request. WHG-compliant limit signal transmitter (optional) SIL2 (optional) German Lloyd (GL, optional) UL recognized component (see www.ul.com/database, search by keyword "E225237") IEC 60529: Degrees of protection provided by enclosures (IP code) IEC 61010-1: Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use EN 60079-11: Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "I" (optional) Ordering information Detailed ordering information is available from the following sources: In the Product Configurator on the Endress+Hauser website: www.endress.com -> Click "Corporate" -> Select your country -> Click "Products" -> Select the product using the filters and search field -> Open product page -> The "Configure" button to the right of the product image opens the Product Configurator. From your Endress+Hauser Sales Center: www.addresses.endress.com Product Configurator - the tool for individual product configuration Up-to-the-minute configuration data Depending on the device: Direct input of measuring point-specific information such as measuring range or operating language Automatic verification of exclusion criteria Automatic creation of the order code and its breakdown in PDF or Excel output format Ability to order directly in the Endress+Hauser Online Shop Accessories Various accessories, which can be ordered with the device or subsequently from Endress+Hauser, are available for the device. Detailed information on the order code in question is available from your local Endress+Hauser sales center or on the product page of the Endress+Hauser website: www.endress.com. 10 Endress+Hauser

Device-specific accessories Miscellaneous Extension relays Order no. Relay card incl. terminals RIA45X-RA Extension to two-channel device Order no. Multifunction input card for channel 2 incl. terminals, non-ex Multifunction input card for channel 2 incl. terminals, Ex-version RIA45X-IA RIA45X-IB Communication-specific accessories Designation Interface cable Commubox TXU10 incl. FieldCare Device Setup and DTM Library Commubox FXA291 incl. FieldCare Device Setup and DTM Library Supplementary documentation System components and data manager - solutions to complete your measuring point: FA00016K/09 Operating Instructions for process display unit RIA45: BA00272R/09 Ex-related additional documentation: ATEX II(1)GD [Ex ia] IIC: XA00076R/09 SIL Safety Manual: SD00014R/09 Endress+Hauser 11

www.addresses.endress.com