Technical Specification Ardhowen Theatre

Similar documents
SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

INFORMATION FOR VISITING COMPANIES

Technical Specification for the Alley Theatre, Strabane

Technical Specification

ISLAND HALL TECHNICAL INFORMATION

Theatre Technical Specification

Main House Technical Specification

20 hemp bars, set at random intervals (SWL=150lbs) Fixed position situated Stage Right. Operated stage level, SL (counterweighted)

The Haymarket Basingstoke Technical Specifications

Dr JOHN GALLAGHER CONCERT CHAMBER

The Georgian Theatre Royal Technical Information For Visiting Companies

Matt Dann Cultural Centre

The Tower Theatre Contact - Peter Heselden Theatre Manager Tel

DEREHAM MEMORIAL HALL

Technical Specification Pavilion Dance

Technical Specifications Nov 2016

New Theatre Royal Lincoln Technical Information

RPAC REDLANDS PERFORMING ARTS CENTRE

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Theatre SPECIFICATIONS UPDATED: 13/08/13 21 KINGLAND ROAD, POOLE, DORSET, BH15 1UG TELEPHONE: FAX: ADDRESS: TECHNICAL MANAGER:

There are 18 wheelchair positions which will result in the loss of one seat for every wheelchair position allocated.

Stage. Get In & Parking

Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black)

Pleasance London Main House Visiting Company Information Pack May 2017

Technical requirements & conditions for hirers

Latrobe Performing Arts Centre

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

Technical Specification

Hopgood Theatre NOARLUNGA CENTRE

TECHNICAL SPECIFICATION

Technical Information

HIRE AND TECHNICAL INFORMATION

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

TECHNICAL SPECIFICATIONS

Theatre Technical Specifications

Dubbo Regional Theatre & Convention Centre Theatre Technical Specifications

Technical Data Sheet

Technical Specifications Updated 01/10/2017. Stage

THE STREET THEATRE. Technical Specifications

2017 TECHNICAL SPECIFICATIONS

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

Technical Specifications

Technical Information

Hopgood Theatre NOARLUNGA CENTRE

CENTRE FOR PERFORMING ARTS

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

CHELSEA THEATRE. Technical Specifications

Shouson Theatre Venue Specifications (updated Jan 2017)

JERWOOD VANBRUGH THEATRE

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

MERMAID ARTS CENTRE. Outline Technical Specifications as of 17 th January 2018.

TECHNICAL SPECIFICATIONS

Summary. Access and Parking

MAIN AUDITORIUM TECHNICAL INFORMATION

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications. Updated 08/02/2008

COURTYARD!!!!! THEATRE

PLEASE NOTE THAT DUE TO A VOIDED FLOOR PYROTECHNICS ARE NOT PERMITTED IN THE STUDIO.

Cornerstone Technical Specifications 2018 / V1

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

Technical Specifications

Technical Director of Production Andrew Quick Ext 252

Main House Technical Specifications

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

John Leslie Theatre. Technical Specifications. Updated July 2018

Esso BHP Billiton Wellington Entertainment Centre

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

Technical Specification Ver 01/16

Harrow Arts Centre, Harrow Council, Uxbridge Road, Hatch End, Harrow, HA5 4EA tel

Technical Information

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Technical Specification

Technical Specifications

TECHNICAL SPECIFICATIONS RIVERSIDE THEATRE

Concert Hall Technical Specifications

Hirers Technical Information Pack

Salisbury Arts Centre Technical Specification v Page 1 of 7

The Lantern Technical Information

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Technical Manager Dave Nott Tel: * Mo: Deputy Technical Manager Anton Holmes Tel: *

Main Stage Technical Specs - Hall #2

The Lights Technical Guide June 2017

Technical specifications Main theatre. Sound

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

MAIN HOUSE TECHNICAL SPECIFICATION

Tech specs: Main Auditorium. Dimensions. Prompt Corner. Stage Floor. Dressing Rooms (Under stage)

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Technical Services and Specification

Concert Hall Technical Specifications

UNIVERSITY CONCERT HALL. Technical Specification

Arcadia Performing Arts Center Technical Specifications and Information

GORDON CRAIG THEATRE TECHNICAL SPECIFICATION ISSUE 1 10/10/16

Festival City Theatres Trust Festival Theatre Technical Specification. Smoking Policy

MAIN THEATRE TECHNICAL SPECIFICATION Updated 17 th April 2014

"A Dance Tribute to Ping Pong " by Jo Strømgren Kompani. Technical Requirements

Stage. Please see Tron, Main House Lighting Rig Info.pdf for more information. Get In & Parking

Technical Specifications

Access to back stage is off Fletcher St on the eastern side of the building

THEATRE ROYAL MARGATE Technical Specification April 2018

Transcription:

Technical Specification Ardhowen Theatre Stage Proscenium Width Depth Forestage Height Stage Floor Flying System Stage Manager Orchestra Pit House Curtains Masking Cyclorama 8.6M (28.2ft) wide by 5.3M (17.3ft) high. Width may be reduced by the use of the House Curtains or masking. 5.9M (19.3ft) Centre line to stage left. 4.9M (16.0ft) Centre line to stage right. 8.5M (27.8ft) From tab line to back wall. 8.6M (28.3ft) From Stage face of the Proscenium. 1.4M (4.6ft) From Stage face of the Proscenium to permanent stage edge. The orchestra pit extend the stage a further 2.8M (9.2ft) beyond the permanent stage edge. Under Galleries around stage area 4.9M (16.0ft) Under ceiling main stage area. 7.5M (24.6ft) Stage height above auditorium floor 0.6M (1.8ft) Flat and level. Maple flooring painted black. 16 installed counterweight sets at varied distances apart. Maximum Bar Weight (evenly distributed) 400 kg. (7.8cwt) Bar length 13M (42.6ft) NO FLYTOWER FACILITY. Working corner is stage left with portable mobile control desk. The desk incorporates, show relay, intercom, bar bells, backstage and foyer page. Stage left also has control switches for work lights, performance states and two speed house tab motor. Pit area 30 cubic metres. Depth below stage level 2.6M (8.6ft) Dimmer controlled power supply. Full house curtains coloured Marine Blue on powered curtain track. Five sets of black velour legs and borders. One set of black velour travellers on 2 curtain tracks, manual hand line open/close. Can be set where required. Full length white cyclorama. Width 12.9M. Depth 6.5M.

Stage Equipment Get In Storage 1 Gene GR20 MEWP. 3 sets of Zarges step ladders. 12 sets of rostra 8ft x 4ft with bolt in legs of varying sizes. Get in via scene dock on stage level. Minimal. Lighting and Power Supply. Technical Data. Independent Power Sources Dimmers Lighting Control Secondary Circuits Mains Power On Stage 2 x 200 amp T.P.N. with separate meter facility. (One designated special effects and one designated outside broadcast.) Both situated at stage level up stage left. 96 x 2.5kw to 15amp three pin socket outlets. Dimmers ETC Sensor+ dimmers contained in dimmer room in scene dock stage left. Memory control is a ETC Expression with Emphasis, 2 LCD screens, wired and wireless remote focus units. 1 Avolites Tiger Touch. 30 single 5amp secondary circuits with independent 3 pin 5amp socket outlets controlled from effects panel in Control Room. Single 13amp ring main with 8 only 3 pin socket outlets with local ELCB.(20amp max) N.B Dip channels 89 to 94 and 98 to 103 have local switch over facility to divert output to alternative locations on forestage. Lantern List 6 Martin MAC 250 Krypton 4 I-solution I-Move 250 2 Robe Robin DLF led 20 750w ETC Source Four Zoom Profiles 20 600w Strand SL 15/32 Profiles 6 600w Strand SL 23/50 Profiles 20 1Kw Strand Harmony 15/28 Profiles 11 1Kw Strand Harmony F Fresnels 2 1Kw Strand Harmony PCs 5 1.2Kw Strand Cantata Fresnel 4 1.2Kw Selecon Fresnel 8 1Kw Selecon Rama Fresnel 32 1Kw Par 64 Par Cans 6 500w Par 64 Floor Cans

10 500w 4cell Strand Coda Battens Cables/Leads Lighting Stands Other Equipment There is a reasonable stock of varying lengths of 15amp to 15amp/15amp to 13amp/15amp to 5amp etc. 4 Strand fully adjustable Lighting stands. 3 UV Tubes in fittings. 1 Hazer Sound Technical Data Outlets Sound Desks Speakers FOH Monitors Amplifiers Graphics/Effects Recording and Playback Equipment 32:8 multicore with 2 only 16:4 surface mount boxes located DSL/DSR & 5M tails on control room end. Allen & Heath GL3300 32 channel mixer. Yamaha LS9 32 channel mixer. Allen & Heath QU 16 4 Nexo PS15 speakers. 2 Nexo LS1200 sub speakers. 4 Martin Audio LE12J monitor. 2 Martin Audio LS 1500 monitor. 1 Nexo 4.1 Digital Amplifier. 2 Martin Audio MA2.8 Amplifiers. 1 Martin Audio MA3.0 Digital Amplifier. 3 Dbx 2231 graphic equaliser.(31 band) 2 Behringer MDX 4600 Multicom Pro. 1 Lexicon MPX550 reverb. 1 Lexicon MPX1 reverb. 1 Tascam CD160 CD Player. 1 Denon DN600F CD Player. 2 Tascam MD 301 MK 2 MiniDisc players. 1 Denon DRM 555 Cassette Player 4 Shure Beta 58 Mic. 6 Shure SM 58 Mic. 6 Shure SM 57 Mic. 5 Sennheiser 835 Mic. 3 Crown PCC 160 Mic. 2 Shure LX Radio Mic. (1 Lapel,1 Handheld.) 1 Sennheiser Lapel Mic. 3 EMO Passive D.I. Boxes.

5 DBX Active D.I. Boxes. Portable PA Mic Stands Cables 1 Allen & Heath PA20 16 channel mixer.(flight cased) 2 Martin Audio F12 speaker. 2 15 bass Bins. 2 Loudspeaker stands. 1 Studiomaster 1200D Amp. (spare) 16 Boom Mic stands and varying lengths of XLR mic cable. 3 10M 8 way stagebox-tail multicore. 1 30M 16:4 stagebox-tail multicore. Audio Visual Equipment Projection Equipment Back Stage Facilities 1 Christie projector Full size roll up cinema screen. Beko 28 Television set. Philips VHS Video Cassette Player. Four Dressing rooms. Laundry room with Washing Machine and Tumble Dryer. Both with metered charge. Ironing board and Iron available. Green room with electric kettle, fridge, and microwave oven. Gents shower situated in gents toilets area. Ladies shower situated in ladies toilets area. Technical Supervisor Mick McLoughlin. Tel. 07581116726 Email michael.mcloughlin@fermanaghomagh.com Technical Assistant Joe Gregory Ardhowen Theatre Information The following information is for person/s or groups using the Ardhowen Theatre. It is in your interest to make sure everyone in your group or company are aware of the regulations that apply to everyone using the stage to avoid any misunderstanding. 1. Times and details of get in and fit up or any technical requirements must be advised to the Technical Supervisor prior to your visit. 2. Should you require lighting rig or stage/theatre plans or technical specifications contact the Technical Supervisor at the theatre.

3. On arrival at the theatre you should use the Stage door entrance and contact the Technical Supervisor or Technical Assistant. If any doubt report to the Administration Office. 4. If you are going to be late or held up for any reason, please contact the theatre and let us know. Telephone No. (028) 66323233. 5. The Ardhowen Theatre is a Non Smoking building. This regulation is strictly enforced. 6. Food, Drinks or Liquids of any kind are not to be taken to or consumed in the Control Room, Auditorium, On Stage or Back Stage Areas. Again the only exemption is when it constitutes part of a legitimate performance. The only areas exempt from this regulation are The Green Room and Dressing Rooms. 7. Any company or act intending to use naked flames/pyrotechnics on stage should notify the Technical Supervisor prior to arrival and subsequent performance. A person familiar in the use of Fire Extinguishers must be present at the time of use. Fire Extinguishers are situated at both sides of the stage. The same regulations apply to the use of flammable liquids and materials. In some cases, i.e. straw/hay permission will not be granted. 8. The painting of sets and scenery should be completed prior to arrival at the theatre, by prior arrangement some painting may be allowed in the scene dock. Painting will not be allowed on stage. 9. Sets or flats must not be spiked, nailed or screwed to the stage floor. The use of staples of any kind is also prohibited and if you intend to use double sided tape, it must not to be put directly on to the stage floor. Contact the Technical Supervisor for advice or clarification. 10. All lanterns in use at the Theatre have a safety bond fitted, they also are complete with a colour frame. It is in your interest to check this. Any colour frame or safety bond missing when you leave will be charged to your company. Any lantern brought into the theatre for use on stage must be complete with safety chain and be within the P.A.T. Wiring and Electrical Appliance regulations. This also applies to any portable equipment used in the theatre, i.e. Smoke Machines, P.A. equipment, lanterns and any other portable electrical equipment. 11. All flats, scenery, drapes, costumes and props etc. must be fireproofed prior to use at the theatre, advice is available from the Technical Supervisor. 12. The use of aerosol paint sprays must not be used anywhere inside the theatre buildings. 13. The Green Room is provided for use by visiting companies. It is important to note that because of its unusual design it is not sound proofed from the Foyer and Gallery areas of the theatre and that excessive noise may be heard in these areas. 14. The Scene Dock and Stage Door entrances are in the Rear Courtyard.