AUDITORIUM PERFORMANCE AREA Standard (with END ON seating) 8.75m Wide x 7.3m Deep (to US black) Open Floor (seating retracted) 8.75m Wide x 13m Deep (to US black) Standard (with THRUST seating) 6.1m Wide x 4.6m Deep Open Floor (seating removed) 9.3m Wide x 6.3m Deep HEIGHT 4.24m (to grid) 2.76m (to grid) 2.44m (to beams) The ceiling consists of structural beams with recessed lighting bars, so for set purposes the ceiling is at 2.44m. SEATING CAPACITY ACCESS Standard 98 in semi-permanent rake Open Floor Up to 120 chairs possible, on floor and/or rostra (the venue has 60 chairs available). Other seating configurations available on request. Preferred LOAD IN doors are stage left, with access through the corridor from the foyer. There are additional doors at the rear of the auditorium. Doors: 1.6m Wide x 2.1m High Please advise in advance of arrival how much equipment is to be loaded Standard 52 in semi-permanent THRUST configuration. Other seating configurations available on request. Preferred LOAD IN doors are stage right, via a staircase with two 180 turns There is additional access to stage left via a narrow staircase. Door: 760mm(w) x 2100m(h) Please advise in advance of arrival how much equipment is to be loaded 1 OF 6
FLOOR Hardboard skin over hardwood parquet with an internally sprung substructure, painted black. Minimal screwing permitted. Please note, the floor is NOT load bearing. Hardboard skin over concrete, painted black. Screwing is not permitted. WALLS Exposed brick, painted black. Exposed brick, painted black. MASKING ACCESS EQUIPMENT CONTROL BOX COMMS Full-width black serge, and full-width black gauze. 4 x black serge legs. An assortment of small soft pieces. 2 x Zarges ladders 2 x stepladder Located at the rear of the auditorium, behind the raked seating with an excellent view of the playing space. Suitable for 2 / 3 ops. Space outside of the box for a sound op to be positioned. Alternative positions are available. Please contact the Technical Manager for further information. A walkie talkie is available to the company to contact the Duty Technician during performances. Canford comms system with two belt packs. Full-width black serge. An assortment of small soft pieces. Located SL, small space for one operator with a small window and view of the playing space. Alternative positions are available. Please contact the Technical Manager for further information. A walkie talkie is available to the company to contact the Duty Technician during performances. 13 AMP POWER 4 x RCD protected double sockets, two on each side of the auditorium 2 x RCD protected double sockets, one on the upstage wall and one on the stage left wall 2 OF 6
THE PIT A sunken area at the upstage. The pit can be used as a storage area, but may be used for technical applications (e.g. the placement of low-level backlight), or as a crossover. LIGHTING GRID CIRCUITS Safe Working Load is 100kg per bar (including lanterns). 6 Internally Wired Bars (IWBs), each with 10 x 15A sockets (some paired). 6 x 15A sockets at floor level. Safe Working Load is 100kg per bar (including lanterns). 12 sets of 4 x 15A sockets, spaced throughout the auditorium. CONTROL ETC Ion ETC Nomad DIMMERS 2 x Strand LD24 racks, for a total of 48 4 x Zero88 Betapacks, for a total of 24 ways ways Additional 18 ways at floor level (located in The Pit) on request. PATCH Addresses 1-24 hard-patchable from 30 circuits in grid and 6 floor circuits Addresses 25-48 hard-wired from 30 circuits (18 single and 12 paired) Addresses 1-24 hard-patchable from 48 circuits HOUSE LIGHTS 2 x Coda Floods 4 x 150W Floods 3 OF 6
LANTERNS Units may be interchangeable between venues. Please contact Technical Manager for availability details. PROFILE FRESNEL PC 5 x Source Four 50 575W 2 x Source Four 36 575W 2 x 26 Lens Tubes 6 x Source Four Junior Zoom 14 x Patt 743 1K 4 x Teatro Spazio 1K (2 missing Barn Doors) 6 x Selecon Acclaim 650W 2 x Harmony 1K (1 missing Barn Door) 6 x CCT Minuette 21/36 Zoom 8 x CCT Minuette 650W 2 x Patt 123 PAR 10 x Par 64, various lamps 6 x Par 56 (MFL) FLOOD 6 x Coda Flood 500W 6 x 150W Flood LED 7 x Showtec Compact Par 18 SOUND DESK Yamaha TF1 Soundcraft Spirit F1 Mixer AMPLIFIERS SPEAKERS 2 x Carver PM-600 1 x Yamaha P3500S 2 x Bose 802 with system controller (FRONT) 2 x Fostex SP11 (Auditorium) 2 x Fostex SP11 (US) 1 x Tannoy TS10 (SUBS) 2 x Mackie SRM450 v2 Active 2 x T-Amp E400 4 x JBL Control 1 s 4 OF 6
PLAYBACK Mac Book Pro running Qlab 3 - Mini-Jack / RCA input to mixer Macbook Pro running Qlab 3 Mini-Jack / RCA input to mixer MICROPHONES COMPUTER 2 x Shure SM58 1 x Sennheiser EW 112P imac MacBook Pro - Depending on availability, please contact Technical Manager for further information MacBook Pro - Depending on availability, please contact Technical Manager for further information VIDEO PROJECTOR Optoma H180X HD DLP Optoma H182X 3D DLP Both with HDMI / VGA feed to control box or anywhere in the auditorium SCREEN ADAPTERS 2.6m x 1.5m, 16:9 ratio, retractable by remote control 2 x Mac to HDMI 2 x Mac to VGA 2.6m x 1.5m, 16:9 ratio, retractable by remote control MISCELLANEOUS HAZER Martin Magnum Hazer (DMX) SCAFF 4 x Boom Bases (Doughty Tank Traps) Scaff Bars (various lengths) Boom Arms We have a small stock of clamps and connectors, please contact Technical Manager for further information 5 OF 6
MIRROR BALL 40cm diameter with DMX-controllable rotator LAUNDRY Laundry facilities are available including a domestic washer/dryer, iron and ironing board. Locally there are several dry cleaners should the company prefer. 6 OF 6