Lumiblade OLED Product Catalog OLED panels

Similar documents
Lumiblade OLED GL46. Data Sheet

Lumiblade OLEDs Product Catalog OLED panels

OLEDWorks OLED Panel Brite Amber Marker Light

Lumiblade OLED Panel Brite FL300 wm

OLEDWorks Lumiblade OLED Panel Brite 3 FL300 ww Warm white 3000K

Philips Lumiblade OLED Panel Brite 2 FL300L ww

Lumiblade OLED Panel Brite FL300 L ww + wm

Lumiblade OLED Panel Brite FL300 ww

Lumiblade OLED Panel Brite FL300 ww

Lumiblade OLED Panel Brite FL300 L ww + wm

OLEDWorks LumiCurve Wave FL300C nw Neutral white 4000K

LG OLED Light Panel. Flexible panels

LED MODULES READYLINE DL

Handling Instruction. Light Panel. User Guide v1.0. Please read this user guide carefully before using the product.

Features. High Brightness SMD LED Light source

Design-in Guide OLED Panel Brite 3 Family. July 2018

OLED light Panel. Please read this user guide carefully before using the product. User Guide v3.0. LG Display User manual

Specification. EdiLex AC UFO Module 230V Series Datasheet 5ELACN2T23A ELACN2T23A ELACN2T23B Drawn Approval Approval

Design-in guide. Philips Lumiblade OLED Panel Brite Family

R xx-C0900-J074

Design-in guide. OLED Panel Brite 2 Family. September 2016

Benefits. Applications

SubstiTUBE Value ST8-HV5

R Rxx-Vxxxx-L334-x

ET-5050x-BF1W Datasheet

Federal 3535 FX-C White Datasheet

SubstiTUBE Value ST8V-0.6m

LUXFLEX PREMIUM THIN & FLEXIBLE BACKLIGHTING. Indoor/Outdoor Series

OLED Light Panel. Please read this user guide carefully before using the product. User Guide v1.0. OLED Light Division

LCD MODULE SPECIFICATION

W LC Datasheet

PLCC W 2 Series IEC White Datasheet

EdiLex 120V AC Module G2 series Datasheet

SubstiTUBE Value EM ST8V-1.2m-17W-EM

OLED Technology Introduction

PLCC W CRI90 Datasheet

Specification. EdiLex AC Ultra-Low Flicker Module 230V Datasheet. Drawn Approval Approval

Coreline Malaga LED BRP101/102. Time for Coreline Malaga LED

PLCC Series 2835 SE PCT

PLCC Series 5630B HE High CRI

Filament Series Flexible Filament

Bulb Down Light Decorative Light

YJ-VTC-5730-G02 High CRI LED

PLCC W 6000K Series Datasheet

L xxx-C0720-K255

PLCC Series W. Datasheet. Introduction : Feature and Benefits : Description : PLCC Series

3528 1W 2 Series White (IP)

Lumiblade Living Shapes Interactive light installation

3528 1W 3 Series White

LUXFLEX STANDARD THIN & FLEXIBLE BACKLIGHTING. Indoor Series

YJ-BC-3030-G01 High CRI LED

PLCC W CRI K Datasheet

PLCC W LC CRI80 Datasheet

V. PLCC Series. Datasheet. Introduction : Description : Feature and Benefits : PLCC Series

PLCC S Series W 9V

PLCC 5630B 0.5W High CRI Datasheet

PLCC W CRI 80 Datasheet

AA3528VR4AS-W2 3.5 x 2.8 mm Surface Mount LED Lamp

YJ-VTC-2835-G01 High CRI LED

Mini LED Pin Spot Light Model: PLS00571

YJ-BC-2835L-G02 High CRI LED

LA1500R USER S GUIDE.

LUXFLEX FLEXIBLE, COLORFUL BACKLIGHTING

EdiLine III Series Datasheet

SubstiTUBE Advanced ST8-HA4

SubstiTUBE Advanced UO EM ST8AU-1.5m-24W-EM

Technical operating data

SMART CINEMAHORIZONTAL. User Guide VPSP Projector side. model. Notice SmartCrystal Cinema MUV V1R0

Emergency lighting units EM powerled

PLCC Series EMC 3030 Single color

WAH WANG HOLDINGS (HONG KONG) CO., LTD.

EdiPower II Series. Features LED light engine High power operation Instant on Long lifetime. Copyright 2010 Edison Opto. All rights reserved.

Technical operating data

Decorative lighting. Decorative Light

Guidelines for Specification of LED Lighting Products 2010

SURFACE MOUNT DISPLAY. Features. Descriptions. Package Dimensions& Internal Circuit Diagram

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 872 LIGHT EMITTING DIODE TRAFFIC SIGNAL LAMP UNITS JULY 19, 2002

ELECTRICAL-OPTICAL CHARACTERISTICS (T C = 25 C) VALUE MIN. TYP. MAX.

DEM A SBH-CW-N

DEM K SBH-PW-N

COOLEDGE LINE - SPECIFICATIONS (CE COMPLIANT) SYSTEM OVERVIEW GENERAL SPECIFICATION FEATURES. DATE NOTE For Luminous Surfaces

Flexible Filament Bulb ST64_4W Golden Datasheet

LED bar- Built-in constant current - 105Lm/W-thin 5.5mm-waterproof

FLUID VIEW 12V LED TAPE LIGHT

DOB Series PHI33. EdiPower III. Dim to Warm 230V Datasheet. Introduction :

Fortimo LED downlight module Twistable Gen 2

SmartCrystal Cinema Neo

ELECTRICAL-OPTICAL CHARACTERISTICS (T C = 25 C) VALUE MIN. TYP. MAX.

3B SCIENTIFIC PHYSICS

EdiPower II HM Series (PAR) Datasheet

Datasheet. LED Transformers. LED Transformer 120W 24V V. LED Transformers

HYL-080D1750G358. Constant current LED driver DALI Dimmable. LED Driver. Product description. Benefits. Interfaces.

Tube Roller Shakers. User Guide. Version 1.2

DEM A SBH-PW-N

LED DRIVERS. LQC4D-V1 4 channels. User Manual FEATURES

CHIMEI INNOLUX DISPLAY CORPORATION

LED Spot 300W. Please read this user manual before your operation

It s important to stand out from the crowd.

KHT 1000C HV-Probe Calibrator. Instruction Manual

LED Lighting 12 th Annual Building Codes Education Conference March Bozeman, MT Jaya Mukhopadhyay, Co-Director, Integrated Design Lab

Transcription:

Lumiblade OLED Product Catalog OLED panels 2012 1

Welcome to the new art of lighting Lumiblade is OLED lighting at Philips and definitely more than just another light source it is a highly-adaptable material that removes the boundaries of shape and size associated with conventional lighting. It offers incredible potential to change the way we use light to shape objects and architecture. At the forefront of OLED technology, Philips Lumiblade demonstrates unique characteristics and capabilities that can redefine lighting, and the way we use and experience it: its homogenous output, unusual appearance, low heat emission, extremely flat nature and high degree of controllability. 1

Reduce to the max With less than 2mm total height of the light emitting surface, Lumiblade OLEDs enable thin lighting applications. Plus, there is no secondary optics needed anymore as the lit material can already be the functional surface. This adds up to 100% system efficiency and 0% waste of space. Almost no heat, definitely in all materials With OLEDs being surface emitters, they also do not have a heat sink as the temperature is already distributed. Thus, Lumiblade OLED panels can be used in harmonic coexistence with most other materials, where using other light sources was simply not possible before. Finest material in lighting If quality of lighting matters, the natural light from the surface of Lumiblade OLED panels will be the right material to satisfy any customers requirements. As an alternative to the shiny reflective surfaces, Philips is also offering solutions which contain a light outcoupling foil for higher light output and for a soft and warm material surface. These factors open up endless opportunities to create groundbreaking new lighting concepts and experiences, which will in turn provide consumers with dramatic and unexpected ways to create atmosphere in a room. This catalog can only deliver basic information on the nominal operating characteristics. In case you cannot find the characteristics you are looking for or you want to discuss an OLED lighting project with our experts, feel free to contact us any time. 2

Contents Philips Lumiblade OLED panel GL8 page 4 9 Philips Lumiblade OLED panel GL26 page 10 15 Philips Lumiblade OLED panel GL55 page 16 20 Philips Lumiblade OLED panel GL30 page 21 26 Philips Lumiblade OLED panel GL46 page 27 32 OLED Application Note page 33 36 Philips Lumiblade SCP 1002 page 37 40 Technical Drawings page 41 45 Safety Statement page 46 3

Philips Lumiblade OLED panel GL8 L0032 CE30 40 49,5 40 49,5 Type L0032 CE30 9254.000.031 Color / CCT CIE x/y white 2950K Lum. Flux CRI Voltage Rated Current 8.0 lm 89 7.0 V 75 ma Notes: All values are nominal values measured at standard temperature and pressure. Connectors This OLED is delivered with solderable patches. Electrical Rated voltages Type Rated Max Minimum Nominal Maximum Current Current voltage voltage voltage L0032 CE30 75 ma 225 ma 6.7 V 7.0 V 7.3 V Rated voltages and maximum values apply to new OLEDs. Voltage can increase over lifetime. We strongly recommend the usage of a short protection circuit. 4

Forward current versus forward voltage Luminous fl ux Rated luminous flux Type Rated Luminous fl ux Luminous fl ux Luminous fl ux Current min nominal max L0032 CE29 75 ma 7.2 lm 8.0 lm 8.8 lm Luminous flux versus forward current 5

Luminous efficacy versus current density Lifetime Lifetime Type Lifetime L0032 CE29 10000 h 1 1 Until 50% decrease in luminance or defect (L50B50) at nominal current Homogeneity. At room temperature. Homogeneity Homogeneity Type Rated Current Homogeneity min Homogeneity nominal Homogeneity max L0032 CE29 75 ma 90% Luminance Luminance Type Rated Current Luminance min Luminance nominal Luminance max L0032 CE29 75 ma 1350 cd/m² 1500 cd/m² 1650 cd/m² 6

Luminance versus current Luminance versus angle Normalized luminous intensity versus angle 7

Color Integral spectrum Correlated Color Temperature Type Rated Current CCT min CCT nominal CCT max L0032 CE29 75 ma 2950 K Color rendering index Type Rated Current CRI min CRI nominal CRI max L0032 CE29 87 8

Color versus angle Integral color point versus current density 9

Philips Lumiblade OLED panel GL26 L0023 CE29 61± 0.2 74 ± 0.2 61± 0.2 74 ± 0.2 Type L0023 CE29 9254.000.032 Color / CCT CIE x/y white 2900K Lum. Flux1 CRI Voltage Rated Current 26.0 lm 87 7.2 V 270 ma Notes: All values are nominal values measured at standard temperature and pressure. Connectors OLEDs of this product family are shipped with minimal 100mm red cables, finished with Molex Picoblade connector: 51021-0500. Electrical Rated voltages Type Rated Current Max Current Minimum voltage Nominal voltage Maximum voltage L0023 CE29 270 ma 450 ma 6.9 V 7.2 V 7.5 V Rated voltages and maximum values apply to new OLEDs. Voltage can increase over lifetime. Philips strongly recommend the usage of SCP 1002, see page 32. 10

Forward current versus forward voltage Luminous fl ux Rated luminous flux Type Rated Current Luminous fl ux min Luminous fl ux nominal Luminous fl ux max L0023 CE29 270 ma 24.7 lm 27.5 lm 30.3 lm Luminous flux versus forward current 11

Luminous efficacy versus current density Lifetime Lifetime Type Lifetime L0023 CE29 10000 h 1 1 Until 50% decrease in luminance or defect (L50B50) at nominal current Homogeneity Homogeneity Type Rated Current Homogeneity min Homogeneity nominal Homogeneity max L0023 CE29 270 ma 90% 12

Luminance Luminance Type Rated Luminance Luminance nominal Luminance Current min max L0023 CE29 270 ma 1800 cd/m² 2000 cd/m² 2200 cd/m² Luminance versus current Luminance versus angle 13

Luminous intensity versus angle Color Integral spectrum Correlated Color Temperature Type Rated CCT CCT CCT Current min nominal max L0023 CE29 270 ma 2900 K Color rendering index Type Rated CRI CRI CRI Current min nominal max L0023 CE29 270 ma 87 14

Color versus angle Integral color point versus current density 15

Philips Lumiblade OLED panel GL55 L0022 CE32 ILO 130,2 116,73 47,8 35,2 Type L0022 CE32 ILO 9254.000.033 Color / CCT CIE x/y white 3200K Lum. Flux 1 CRI Voltage Rated Current 55.0 lm 86 7.2 V 390 ma Notes: All values are nominal values measured at standard temperature and pressure. Connectors OLEDs of this product family are shipped with minimal 100mm long red cables, finished with Molex Picoblade connector: 51021-0500. Electrical Rated voltages Type Rated Max Minimum Nominal Maximum Current Current voltage voltage voltage L0022 CE32 ILO 390 ma 450 ma 7.0 V 7.3 V 7.6 V Rated voltages and maximum values apply to new OLEDs. Voltage can increase over lifetime. Philips strongly recommend the usage of SCP 1002, see page 32. 16

Forward current versus forward voltage Luminous fl ux Rated luminous flux Type Rated Current Luminous fl ux min Luminous fl ux nominal Luminous fl ux max L0022 CE32 ILO 390 ma 49.0 lm 55.0 lm 61.0 lm Luminous flux versus forward current Lifetime Lifetime Type Lifetime L0022 CE32 ILO 7000 h 1 L0022 CE32 ILO 20000 h 2 1 Until 50% decrease in luminance or defect (L50B50) at nominal current 2 Until 70% decrease in luminance or defect (L70B50) at 1000 cd/m² 17

Homogeneity Homogeneity Type Rated Current Homogeneity min Homogeneity nominal Homogeneity max L0022 CE32 ILO 390 ma 80% Luminance Luminance Type Rated Current Luminance min Luminance nominal Luminance max L0022 CE32 ILO 390 ma 3750 cd/m² 4200 cd/m² 4650 cd/m² Luminance versus current Luminance versus angle 18

Normalized luminous intensity versus angle Color Integral spectrum Correlated Color Temperature Type Rated Current CCT min CCT nominal CCT max L0022 CE32 ILO 390 ma 3200 K Color rendering index Type Rated Current CRI min CRI nominal CRI max L0022 CE32 ILO 390 ma 86 19

Color versus angle Integral color point versus current density 20

Philips Lumiblade OLED panel GL30 L0060 CE32 120 94,64 Type L0060 CE32 9254.000.035 Color / CCT CIE x/y white 3200K Lum. Flux1 CRI Voltage Rated Current 35.6 lm 86 7.3 V 350 ma Notes: All values are nominal values measured at standard temperature and pressure. Connectors OLEDs of this product family are shipped with minimal 100mm long red cables, finished with Molex Picoblade connector: 51021-0500. Electrical Rated voltages Type Rated Max Minimum Nominal Maximum Current Current voltage voltage voltage L0060 CE32 350 ma 400 ma 7.0 V 7.3 V 7.6 V Rated voltages and maximum values apply to new OLEDs. Voltage can increase over lifetime. Philips strongly recommend the usage of SCP 1002, see page 32. 21

Forward current versus forward voltage Luminous fl ux Rated luminous flux Type Rated Luminous fl ux Luminous fl ux Luminous fl ux Current min nominal max L0060 CE32 350 ma 35.6 lm Luminous flux versus forward current 22

Luminous efficacy versus current density Lifetime Lifetime Type Lifetime L0060 CE32 6500 h 1 L0060 CE32 10000 h 2 1 Until 50% decrease in luminance or defect (L50B50) at nominal current 2 Until 70% decrease in luminance or defect (L70B50) at 1000 cd/m² Homogeneity Homogeneity Type Rated Current Homogeneity min Homogeneity nominal Homogeneity max L0060 CE32 350 ma 80% 23

Luminance Luminance Type Rated Current Luminance min Luminance nominal Luminance max L0060 CE32 350 ma 2250 cd/m² 2450 cd/m² 2700 cd/m² Luminance versus current Luminance versus angle 24

Normalized luminous intensity versus angle Color Integral spectrum Correlated Color Temperature Type Rated Current CCT min CCT nominal CCT max L0060 CE32 350 ma 3200 K Color rendering index Type Rated Current CRI min CRI nominal CRI max L0060 CE32 350 ma 86 25

Color versus angle Integral color point versus current density 26

Philips Lumiblade OLED panel GL46 L0050 CE32 ILO 85 85 Ø 71 Type L0050 CE32 ILO 9254.000.034 Color / CCT CIE x/y white 3200K Lum. Flux1 CRI Voltage Rated Current 48.0 lm 89 7.1 V 350 ma Notes: All values are nominal values measured at standard temperature and pressure. Connectors OLEDs of this product family are shipped with minimal 100mm long red cables, finished with Molex Picoblade connector: 51021-0500. Electrical Rated voltages Type Rated Current Max Current Minimum voltage Nominal voltage Maximum voltage L0050 CE32 ILO 350 ma 400 ma 6.9 V 7.1 V 7.3 V Rated voltages and maximum values apply to new OLEDs. Voltage can increase over lifetime. Philips strongly recommend the usage of SCP 1002, see page 32. 27

Forward current versus forward voltage Luminous fl ux Rated luminous flux Type Rated Current Luminous fl ux min Luminous fl ux nominal Luminous fl ux max L0050 CE32 ILO 350 ma 43.0 lm 48.0 lm 53.0 lm Luminous flux versus forward current 28

Luminous efficacy versus current density Lifetime Lifetime Type Lifetime L0050 CE32 ILO 8500 h 1 L0050 CE32 ILO 20000 h 2 1 Until 50% decrease in luminance or defect (L50B50) at nominal current 2 Until 70% decrease in luminance or defect (L70B50) at 1000 cd/m² Homogeneity Homogeneity Type Rated Current Homogeneity min Homogeneity nominal Homogeneity max L0050 CE32 ILO 350 ma 75% Luminance Luminance Type Rated Current Luminance min Luminance nominal Luminance max L0050 CE32 ILO 350 ma 3400 cd/m² 3800 cd/m² 4200 cd/m² 29

Luminance versus current Luminance versus angle Normalized luminous intensity versus angle 30

Color Integral spectrum Correlated Color Temperature Type Rated Current CCT min CCT nominal CCT max L0050 CE32 ILO 350 ma 3200 K Color rendering index Type Rated Current CRI min CRI nominal CRI max L0050 CE32 ILO 350 ma 89 31

Color versus angle Integral color point versus current density 32

OLED Application Note Introduction The purpose of this application note is to give general information on how to drive and handle an organic light emitting diode (OLED). Recommendations are made and a few best practice examples are presented. OLED OLED Architecture A typical example of the architecture of an OLED is depicted in Figure 1. It comprises the following layers/components: glass substrate transparent anode made of indium tin oxide (ITO) being the fi rst electrode multiple organic layers, each having a different function metallic cathode being the second electrode cover glued to the substrate protecting the organic materials, mostly made of glass getter to chemically bind oxygen and water penetrating through the glue rim. Figure 1: Lumiblade GL350 B1 STAN In the case a constant voltage is applied to the electrodes of the OLED a current starts to flow through the organics generating light. Electrical parameters OLEDs are supplied by direct current (DC). The OLED current depends on the size of the OLED and the light output one wants to achieve. The voltage of an OLED depends on the organic stack, the internal architecture and the aging of the OLED. It may vary between 3 V and 16 V per OLED. Details about voltage and current are given in the individual datasheets. A simple equivalent OLED model is given in Figure 4. It comprises the ITO resistance R ITO 15 Ω/, OLED capacitance C OLED 200 400 pf/mm 2 and the OLED IV-characteristic, which can be described with a parabolic or exponential equation. Figure 4: Simplifi ed equivalent circuit of an OLED The obtained model is well suitable to use for the design of the OLED driver, especially for simulations, e.g. with PSpice, Matlab/ Simulink and Simplorer. 33

OLED Short Circuit Protection In the rare event that an OLED fails it goes into a short condition, its voltage decreases. This condition should be avoided! Hence, an electronic circuitry to prevent local heating due to shorts is strongly recommended. Philips offers approved short circuit protection circuitries. DRIVER ARCHITECTURES Drivers for LEDs Drivers developed for inorganic LEDs can be used for OLEDs. An example of a LED driver that can be used to power OLEDs is the Philips Xitanium 25W LED TD/Is. Figure 5: Xitanium LED driver However, these drivers do not shut off in the case a short occurs. Philips has designed products, so called short circuit protection, to overcome this problem. Examples are the SCP1002 and the Philips Lumiblade SCP GL350. The resulting architecture is depicted in the example below. Figure 6: Dual-stage architecture using LED driver and SCP Low voltage intermediate bus A second driver architecture is depicted in Figure 7. It uses an intermediate low-voltage bus. Short-circuit protection is implemented in the LV drivers. Figure 7: Dual-stage driver architecture with 24V DC bus 34

The LV driver can be integrated in the module as has been done in the Philips Lumiblade TILE-T product. Integrating the driver in the OLED lamp enables the inclusion of special functions. Examples are protection circuits, e.g. over current, over temperature and short circuit protection, dimming (AM and/or PWM), communication and compensation techniques. Figure 8: Lumiblade TILE-T BEST PRACTICES GL350 A system based on GL350 that has been successfully tested at Philips. It comprises: 3 OLEDs of type Lumiblade GL350 B1 STAN 10NC: 9254 000 019 1 SCP of type Lumiblade SCP GL350 PCBK 10NC: 9254 000 020 1 cable of type Fortimo LED DLM cable 10NC:9290 004 631 1 driver Xitanium LH 0.3-1A 62V TD/TE /I 230V 10NC:9290 006 171 All components can be easily clicked together. The light output of this system is 350 lm. L0022/ L0023 / L0050 / L0060 A second system that has been tested is depicted in Figure 9 below. Figure 9: Proposed architecture for L0022 with LED drivers (AC-to-DC) The system setup comprises the following components: 3 OLEDs of type Lumiblade L0022, L0023, L0050 or L006010NC: 9254 000 007 3 SCP of type Lumiblade SC1001 or SCP1002 0NC: 9254 000 008 1 driver: Microdriver 9 MDU-9-SC-35/70 The components have to be wired according to the scheme depicted in Figure 9. 35

DOS AND DON TS Electrical handling OLEDs should be powered by direct current (DC). The OLED driver should be current controlled [2]. OLEDs can only conduct current in forward direction. Dimming can be done by amplitude modulation (AM) or by pulse width modulation (PWM). It should be guaranteed that OLEDs are not powered during fault conditions (shorted OLED). Preferably OLEDs are connected in series not in parallel. Mechanical handling OLEDs are made of 1.8 mm glass, thus please avoid mechanical stress, such as shock, pressure and especially point loads on the OLED. To avoid fingerprints on the glass, preferably pick up the OLED by touching the sides. Gloves or finger cots are recommended to wear during the contact with the OLED at any time. Also the OLED edges are very sensitive. Please handle OLEDs with care and caution at any time. Please avoid contact with water, because the contact area might be damaged due to corrosion of the conductive metal. So if water has to be used, please pay attention to cover the contact areas with waterproof material. Do not submerge OLEDs in any kind of solvent, acids, bases, salts or other chemicals. Please avoid touching the OLED s front glass and the electrodes with bare fingers, as this will leave moisture and cause corrosion. Cleaning Please avoid scratching the front glass with any hard or sharp objects. Do not use any other chemical than isopropanol or ethanol for removing stains and finger prints. OLEDs can be cleaned with any soft textile. For every day cleaning, it is advised to use a compressed air deduster spray to remove regular dust from the individual panels. Cleaning should start on the top left and go from left to right downwards. Should finger prints or more persistent contamination have occurred, a lint-free cloth in combination with Isopropyl alcohol should be used. Apply a little of the liquid to the cloth and gently clean the surface of each OLED in circular movements beginning at the center of the OLED towards the outside. Never use water on the OLEDs as this may damage the electronic back plane of the installation. Storage and Operating Please note that the recommended storage temperature is 15 C to 40 C. The recommended relative storage humidity is below 70%. The optimal operating temperature range is between 15 C and 25 C. Safety Please be cautious when handling OLEDs. Especially, the edges of the OLED panels are sharp, can chip and break. Since OLED is a low voltage technology, no further danger from electricity is expected. Disposition Dispose OLED according to the local legislation. 36

Philips Lumiblade SCP1002 Description The Philips Lumiblade SCP1002 is an OLED supervision circuit, which bypasses the OLED in the case a fault occurs. It monitors the OLED forward voltage. If the OLED voltage drops below a defi ned threshold value, a bypass is created taking over the OLED current. The SCP1002 contains an OLED voltage detector, a fi xed trigger delay and a bypass thyristor. The voltage detector monitors the OLED forward voltage. The trigger delay enables proper start-up of the OLED. The thyristor is used as bypass. System setup The SCP1002 has to be placed between a standard LED driver, which can be connected to the wires of SCP1002 and compatible Philips Lumiblade OLED Panels. It is also possible to use multiple OLED Panels with multiple SCP1002 in series. An example is given in fi gure 3. Drawings 37

Functional Description The working of the detection circuit can be explained with the waveforms shown in fi gure 2. Figure 2: Idealized typical waveforms of the separate failure detection circuit. During normal operation a current is fed to the OLED resulting in an OLED voltage U OLED = U OLED,normal. At the instant the OLED fault occurs, the OLED voltage U OLED drops to U OLED = U OLED,short. This voltage drop is detected by the internal electronics of the SCP1002. The voltage at the gate Ugate of a bypass thyristor (SCR = silicon controlled rectifier) starts to rise. After some time has passed and a threshold value has been reached, the thyristor is triggered. The current through the OLED commutates to the SCR. Since the forward voltage of the SCR is lower than the forward voltage of the faulted OLED, also the OLED voltage drops to a level of U OLED = U OLED,clamp, which is equal to the forward voltage of the SCR. Characteristics Symbol Parmeter Condition Min Typ Max Unit U OLED OLED voltage Normal operation 5 7 10 V I OLED OLED current Normal operation 300 500 ma U OLED, short Shorted OLED voltage Fault condition 2 3.5 4 V t SCR on, delay SCR on delay time Fault condition 2 ms U SCR,on I SCR,on SCR on-state Fault condition, 0.8 V voltage SCR on-state I current OLED = 350mA 500 ma t lifetime Fault condition 20000 h Limiting Values Symbol Parmeter Condition Min Typ Max Unit U in Input voltage Normal operation 10 V I in Input current Normal operation 500 ma U in,switch-on Switch on voltage 10 V t SCR on, delay SCR on delay time Fault condition 2 ms 38

Environmental Storage conditions min type max unit temperature 10 20 40 C relative humidity 5 70 85 % due Transport conditions none min type max unit temperature -25 20 60 C relative humidity 5 70 85 % due Operating conditions none min type max unit temperature 5 20 40 C relative humidity 5 70 85 % due none Mechanical Dimensions (without wires) min type max unit dimension, x 40 mm dimension, y 9 mm dimension, d 5 mm weight 2 g Typical application with three OLEDs A typical use of the SCP1002 with three OLEDs in series is demonstrated in fi gure 3. A 230 V / 50 Hz power source feeds an nondiming AC-to-DC converter normally used for inorganic LEDs. The AC voltage is converted to a constant current, e.g. 350 ma. The constant current is fed to a series connection of three OLEDs. The supervision circuits SCP1002 are connected in parallel to the OLEDs. Figure 3: Typical application with three OLEDs Under normal operation, the OLED current is equal to the converter s output current. If a fault is detected the OLED is bypassed by the SCP1002. The current flows through the corresponding SCP1002. The other OLEDs are not affected. 39

Driver requirements Philips Lumiblade SCP1002 is designed for use within OLED application with normal inorganic LED drivers. To protect an OLED in case of a failure, the SCP1002 is connected to the OLED. The rise up time of the LED driver has to be shorter than the specified SCR on delay time tscr,on,delay. Recommended drivers can be found in the application note. OLED connection Make sure that the OLED is only connected with its connector to the output socket of SCP1002. Make sure that the wiring of OLED is not modified! OLED dimming The functionality of SCP1002 is only guaranteed for a minimum OLED current of 300mA. The functionality of SCP1002 cannot be guaranteed if a lower OLED current is used. Pulse with modulation (PWM) dimming cannot be used with SCP1002. Product compatibility list The SCP1002 can be used with the following Philips Lumiblade Panels: 10NC Product name 9254.000.03200 Philips Lumiblade OLED Panel GL26 9254.000.03300 Philips Lumiblade OLED Panel GL55 9254.000.03400 Philips Lumiblade OLED Panel GL46 9254.000.03500 Philips Lumiblade OLED Panel GL30 Attention: Please note the minimum OLED current of SCP1002! Product Identifier & Naming 10NC Product name 9254.000.04700 Philips Lumiblade SCP1002 BK 40

Technical Drawings Philips Lumiblade OLED panel GL8 Emission Side 8±0.2 1.8 4.7±0.2 40 LIT Area Rear Glass 2.5 52.2±0.2 6.7±0.2 Back Side 49.4±0.2 40(x2 2.5 Contact Are 54.7±0.2.5(x2).91 Rear Glass 48.4±0.2 41

Philips Lumiblade OLED panel GL26 Emission Side 1.8 6.7±0.2 Lighting Area 61.4 60.5 Back Side 74±0.2 Minimum100(x2) Pin1 Pin5 (+) (-) Molex Pico Blade_51021-0500 74±0.2 Mark for minus Cable Rear Glass.91 2.5 6.3±0.2 Rear Glass 69±0.2 Rear Glass 70±0.2 42

Philips Lumiblade OLED panel GL55 Emission Side 1.94 6.7±0.2 Lighting Area 116.7 35.2 Rear Glass 42.8±0.2 Outcoupling Foil 6.3±0.2 Back Side 130.2±0.2 Minimum 100mm (x2) Molex PicoBlade-51021-0500 Pin1 (+) Pin5 (-) 47.8±0.2 Mark for minus Cable Rear Glass 2.5(x4) Rear Glass 125.2±0.2 1.05 Outcoupling Foil 43

Philips Lumiblade OLED panel GL30 Emission Side 94.6(x3) 82 7.3±0.2(x3) Lighting area (3880mm2) Back Side 2.5(x3) 115.4(x3) 90 90 91.6±0.2 Rear Glass R3(x3) 30 1.8 Rear Glass Molex PicoBlade-51021-0500 Pin1 (Anode) Pin5 (Cathode) Minimum100(x2) Mark for minus cable 1.8 Rear Glass 104.3±0.2 44

Philips Lumiblade OLED panel GL46 Emission Side 7±0.2(x2) Lighting area (Ø=71) 7±0.2(x2) Back Side Pin 1 (+) Pin 5 (-) Molex PicoBlade-51021-0500 Minimum100(x2) Mark for minus cable Outcoupling Foil Rear Glass (Ø=80) Rear Glass 80±0.2 2.5(x2) Contact Area 80 85±0.2 7(x4) Contact Area 1.94 40±0.2 (x2) Rear Glass 1.05 80±0.2 85±0.2 Outcoupling Foil 45

Safety Statement Intended use This OLED panel is a component intended to be incorporated as light source into luminaires for indoor use only. It shall be installed by qualified professionals in accordance with these instructions and general safety requirements for electrical installations. Safety instructions In case of damage to the product, the OLED must be disconnected from the supply voltage immediately. It may not be reconnected or used in any other way. For safety reasons it is not permitted to convert or modify the product. Philips Lumiblade OLED panels may only be used in conjunction with a short circuit protection approved for the OLED panel to be used. Short circuit protections are available from Philips Lumiblade. The OLED panel is a class III electrical component with accessible live parts. Care must be taken that adequate electrical protection is provided when the OLED is connected to a power supply. This can be achieved by supplying the OLED from an SELV power supply and/or through appropriate electrical insulation. OLED panels are intended for use in dry, weather-protected locations. OLEDs may not be exposed directly to any liquids. OLEDs are fragile electrical components and not toys. Keep out of reach of children! OLEDs contain glass with sharp corners. In case of improper use OLEDs can break and glass splinters may be exposed. Please handle all OLEDs with care to avoid breakage. In case of broken OLEDs or OLEDs with sharps edges/corners, protective gloves shall be worn to avoid injury. Avoid direct contact with broken OLEDs. OLEDs are sensitive to direct pressure to the glass surface. Avoid applying pressure to the glass surface by handling OLEDs near the edges. 46

Standards, compliance and sustainability Philips Lumiblade products are environmentally friendly by avoiding the use of hazardous materials and by providing efficient illumination. This product is RoHS (EU directive 2002/95/EC) compliant. Contact: Philips Technologie GmbH Business Center OLED Lighting Philipsstr. 8, 52068 Aachen, Germany info.lumiblade@philips.com For more information visit: www.lumiblade.com www.facebook.com/lumiblade www.twitter.com/lumiblade www.youtube.com/user/philipslumiblade 2012 Koninklijke Philips Electronics N.V. All rights reserved. Correct at 01.03.2012. 47