Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Similar documents
Equipment Inventory. Seating. Stage. Dressing Rooms. Loading Bay

Half seating, gives a standard theatre style seating array at half the depth of the Full seating, can accommodate 201 Patrons, including Balcony.

Anvil Theatre. Technical Information

Phil L. Thomas Performing Arts Center Shiprock, New Mexico

Technical Specifications and Inventory Spring 2018

Stage: A hardwood maple floor, sprung on rubber cushions. No screws, nails, or other fasteners may be used.

SOUND. * All instruments and circuits have standard 2 pin and ground stage pin connectors. Page 1 of 5

Harbourfront Centre Theatre Technical Specifications As of Jan. 2018

Arcadia Performing Arts Center Technical Specifications and Information

* All public events require the presence of Centerville High School Security. Contact Theatre Manager for details.

Technical Specifications

Technical Services and Specification

Technical Specifications. Taylor Little Theater

Concert Hall Technical Specifications

THE CAPITOL CIVIC CENTRE MANITOWOC, WISCONSIN RENTAL RIDER and SPECIFICATIONS As of September 2015

NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY

Marjorie S. Deane Little Theater

Sandusky State Theatre Technical Specifications

Concert Hall Technical Specifications

HOLLYWOOD CENTRAL PERFORMING ARTS CENTER

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

SHUBERT THEATER 247 College Street, New Haven, CT

W.L. LYONS BROWN THEATRE TECH PACK. Under the Management of

RPAC REDLANDS PERFORMING ARTS CENTRE

Technical Specifications

Downtown Arts Center Tech Packet. General Information

ADDENDUM TO NEW COLLEGE THEATRE HANDBOOK: TECHNICAL INFORMATION

Technical Specifications

Patriots Theater at the War Memorial Technical Data

Main House Technical Specification

TECHNICAL SPECIFICATIONS AND INVENTORY RIALTO THEATER

Bell Cultural Events Center MidAmerica Nazarene University 2030 E. College Way Olathe, KS 66062

Technical Information

Amarillo Civic Center Auditorium 401 S. Buchanan Amarillo, Texas 79101

TECHNICAL INFORMATION PACKAGE WESTON AUDITORIUM FITCHBURG STATE UNIVERSITY 160 PEARL STREET FITCHBURG, MA UPDATED March 2013

Dale F. Halton Theater Technical Specifications

Dr JOHN GALLAGHER CONCERT CHAMBER

Technical Specifications

Technical Information

TECHNICAL PACKAGE.

Technical Specifications

Technical specifications Main theatre. Sound. Console: Soundcraft Si Performer 3

General & Technical Specifications

Parking for cars, busses and tractor/trailers available on the east side of building. Handicapped parking available on the north side of building

P.O Box 1171 Box Office & Theatre: (903) Main St Texarkana, TX TRAHC Office: (903) Texarkana, TX Fax: (903)

SAINT ANSELM COLLEGE DANA CENTER

SABAN THEATER, BEVERLY HILLS TECHNICAL SPECIFICATIONS

WRIGHT AUDITORIUM TECHNICAL INFORMATION. 1. Contact Information. 2. General Information

The ACT Facility Technical Specifications Main Stage Information

Cross Over Back Stage: -Hall way attaching stage right to stage left and the work room -Access from dressing rooms to stage through this hall way

University of Lethbridge University Theatre (W500 University Centre for the Arts) Technical Information

General & Technical Specifications:

1400 MARKET STREET ST LOUIS, MISSOURI Main Number Main Fax

ETC Congo Desk 1024 channels in two universes ( Universe 1 House dimming, Universe 2 Toured dimming) Digital light processor dimmers

Theatre Technical Specifications

SHOWBOX AT THE MARKET TECHNICAL SPECIFICATIONS

Technical Specifications

The Haymarket Basingstoke Technical Specifications

Performing Arts Theatre

Performing Arts Center 3825 HENDERSHOT NW GRAND RAPIDS, MI Phone: (616) Fax: (616)

Our History. Clara Hughes Brott Music Festival Gail Vaz-Oxlade Jimmie Vaughan CBC Townhalls Hamilton Philharmonic Youth Orchestra Wild Kratts

NORTH CHARLESTON PERFORMING ARTS

Theatre Technical Specifications

Jane Mallet Theatre Technical Specifications

O Donoghue Centre for Drama, Theatre and Performance National University of Ireland Galway

Martin W. Kappel Theater TECHNICAL INFORMATION Revision D February 25, 2013

SR Wing space = 2m SL Wing space = 1.1m There is an upstage cross over with pass doors onto stage USR & USL.

Main Stage Technical Specs - Hall #2

Technical Data Sheet

Quick-Advance Fact Sheet

Stage Height: 3-2 CL to SL: 19-9 CL to SR: 22-3

Melrose Veteran s Memorial Middle School Auditorium 250 Lynn Fells Parkway, Melrose, MA, 02176

The Breen Center for the Performing Arts Saint Ignatius High School

Bloomington Center for the Performing Arts. Technical Specifications

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

Matt Dann Cultural Centre

Smothers Theatre Rental Technical Specifications

Camden Opera House Theater. Technical Information

Technical specifications Main theatre. Sound

NORTH CHARLESTON PERFORMING ARTS

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS AND INVENTORY PANTAGES THEATER

Dr. Fred Speckeen Theatre. Information and Technical Specifications

Technical Informa on.zack Theater

Technical Specifications

Theatre Technical Specification

New Theatre Royal Lincoln Technical Information

Lane Community College Performance Hall 4000 E. 30 th Eugene, OR

Technical Facilities Description. Egyptian Theatre. 135 N. Second Street DeKalb, Illinois 60115

Smothers Theatre Technical Specifications Pepperdine University

Scheman Building Suite 102, 1805 Center Drive, Ames, IA Fax Number: Website:

PHOTO : SÉBASTIEN DION TECHNICAL RIDER. imperialbell.com

2017 TECHNICAL SPECIFICATIONS

THE BELDING THEATER. 166 Capitol Avenue Hartford, CT The Bushnell Box Office: (860) The Bushnell Box Office FAX: (860)

Project manager (PM): Pamela Næss Mail: Phone:

THE BUSHNELL CENTER FOR THE PERFORMING ARTS Mortensen Hall

Technical Rider. For more info : Simon Vaillancourt, Technical director (514)

Stage Right wing = 3m 10cm Depth X 6m 40cm Width. Stage to underside of fly galleries from flat floor = 7m

Center Theater Technical Information 9/1/12

The Haymarket. Technical Specifications. The Haymarket, Wote Street, Basingstoke, Hampshire, RG21 7NW

Transcription:

Equipment Inventory Seating Massey Theatre is a fully equipped, 1260 seat facility with 867 seats in the orchestra and the remainder in the balcony. Stage - Black Marmoleum (battleship linoleum) surface with hard crossover along upstage wall - Proscenium width: 39'-10" - Proscenium height: 20' - Width of stage: 79'-9" (including wing space) - SR wing width: 15'--- SL wing width: 24'-6" (Wings measured from edge of Prosc. to offstage wall / pin rail) - Usable depth: 30' - Height of Stage: 40" from orchestra pit floor - Orchestra Pit: 14' at widest depth (at Centre) 38' at widest length - Note: No screwing, nailing, painting stage surface. Dressing Rooms - Under the stage, with easy access to outside and to Stage Left. Currently, there is NO wheelchair access to the dressing rooms. - Max 88 Person capacity - Two water-closets with toilet and sink - Four 4-person dressing rooms with sink (10sq. meters) - Two water-closets with 2 toilets and sink - Two 8-person dressing rooms with double sinks (33.2 sq. meters) - All dressing rooms are equipped with mirrors and make-up lights - Each room, plus common area have program sound - Limited Wi-Fi connection in dressing rooms Loading Bay - Stage: Truck height loading dock (3'-6") - Truck access: 48' long (with a 16' overhang to street) by 21' wide - Loading dock: 26' wide by 19' deep - Access ramp: 4' wide (runs perpendicular to loading dock) - Exterior Loading door: 6'-11" wide by 14'-10" high - (90 degrees to loading dock). 1 P a g e

- Interior Loading door: 5'2" x 14'10" - House: Ramp along house-right exit (via backstage) - Ramp access through lobby. Rigging - All pipe battens are Hemp/ Multiline II line sets - Grid - 47' high wooden grid (unrated) - 4 electrics (1st dead hung, 2nd, 3rd & 4th on winches) - 17 Multiline II/ hemp line sets (max 250 lbs.) o 10 available not in house hang Drapes - Main Drape - red velour (dead hung - opens at centre stage with a hand pull SR) - 3 Black IFR Velour 25oz travelers (flown with hand winches, operated from SR) - 3 Black IFR Velour 25oz Borders and 1 set of legs (flown line sets) o Borders at 2nd and 3rd Lx and cyclorama - Soft Cyclorama (flown line set) Note: All rigging is subject to the approval of the Technical Director. All flies must be operated by authorized Massey Theatre staff. Stage Decks - 8-8 x4 Riser Decks o Have either 8 or 16 legs - 2 Variable Height Cross section legs with wheel attachments used to make a movable 8 x8 platform - 5 8 x4 Wooden platforms with 24 tall wooden supports Audio System FOH Console - Yamaha QL5 Digital Mixing Console o Mix channels: 64 mono, 8 stereo o Busses: 16 mix, 8 matrix (Input to Matrix supported) o Local I/O: 32 in, 16 out o Fader configuration: 32 + 2 (Master) 4 Standard Layers, 4 Custom Layers - Rio 1608-D Stage Box 2 P a g e

o 16 In, 8 Out - Ro8-D Monitor patch rack o 8 Out Main PA - Meyer M elodie line array system. 8 M elodie powered cabinets per side, flown 5 downstage of the proscenium opening - 2 Meyer sound 700hp powered subwoofers (1 each side) - All Meyer Sound components driven by Meyer Galileo 616 system, located in the booth Monitor mix (Mixed from FOH console) - 10 Pre/ Post- fade aux s (2 are semi-permanent to flown monitors), Patchable to various locations around stage - 3 QSC MX 1500a amps Booth Equipment - 2 Denon CD/MP3 Decks (DN - 620) - PC Media Server w/ BluRay playback capabilities - Mic Input Patch Bay - Clear-Com SM Station Mix Location - Booth located at rear of lower seating (under balcony) - 82' to stage front (allow at least 150' cable run to prosc.) - Monitor mix at FOH - Microphone lines - 30 patchable inputs from the stage. 5 locations - 48-8ch Snake from SL to console - Monitor patches 19 patchable outputs from 5 locations Microphones - 8 Shure SM 58 (1 switched) - 6 Shure Beta 58a - 3 Shure Beta 87a - 6 Shure SM 57-4 Shure Beta 57a - 1 Shure Beta 52-3 Shure PG56 (w/ drum mounts) - 2 Audio Technica Pro 37 Condensers - 4 Audio Technica ES935ML6-3 Sennheiser E614 Condensers 3 P a g e

- 4 AKG C3000 Condenser Mics - 1 Audio Technica Microlines - 2 Crown PCC - 5 DOD 625 Passive DI - 3 JDI Duplex DI - 3 JDI Mk III DI - 3 JDI Stereo DI - 1 JDI Passive DI Monitor Speakers - 8 db Technologies LVX XM12 Active Monitors - 4 EV SX300 Monitors (flown) - 2 EV SX80 Monitors (Off Stage Fill) Assorted microphone (XLR), speaker (1/4"), and sub snake cables Assorted microphone and speaker stands Communications - 3 channel Clear-Com Party Line o Patchable: Backstage/ Fly Rail/ Lighting/ Audio/ Spots/ Booth/ FOH - HME DX-200 Wireless Com o 4 Headsets and Transmitters - Program sound to Booths and Dressing Rooms o Stage management announce to Dressing Rooms from SL, SR - Lobby Feed o music / chimes Lighting Control/ Dimmers Console - ETC Ion w/ ELO Touch Screen and 2 nd monitor o 1024 Outputs/Parameters o 10,000 Channels o 10,000 Cues o 999 Cue Lists o 4 x 1000 Palettes (Intensity, Focus, Color, Beam) o USB ports for flash drives, pointing devices, keyboards - ETC Universal Fader Wing 2x20 Dimmers 4 P a g e

- 3 Colortran 1 Series 96 racks o 2.4 kw dimmers o Presently 270 dimmers wired circuit per dimmer House Hang Includes - 15 Area front wash (Source Four 750W Ellipsoidal) - 2 Color top wash (cool & scrollers)(source Four 575W Pars) - Two color bax-wash (Par 64s 1 KW WFL) - Two color side-wash (Altman 6x12's and 6x16's) - 34 Ellipsoidal specials ( 18 in FOH, 16 on stage) o Various Source Four barrels to select from (19 degree to 50 degree) Follow Spots - 2 Robert Juliat 1159 Victor Follow Spot w/ GT4000 Tripod Stands o 208V 1800W MSR Discharge o Optics: 7 14.5 Degree Any additions or changes to the house hang must be approved by the Technical Director prior to your contract date. Projection Booth Projector - Christie HD10K-M o 3Chip DLP o Dual 350W P-VIP lamps o 10K ANSI Lumens o Up to 10,000:1 Contrast o 1920x1080 Native Resolution Stage Projector - Christie DWU599-GS o Inputs: HDMI, VGA, and Mini Display Port o 5400 ANSI Lumens o 6065 ISO Lumens o 1920x1080 Native Resolution Film Screen - 35 W x 15 H Acoustically Perforated Screen - Hung at mid Stage 5 P a g e

Power - Tie in, tie out and daily amperage use are separate charges. - 400 Amp three phase service available (requires 100' feeder run to stage right) - 100 Amp three phase tie-in (stage right proscenium wall) 20amp break out available - Assorted 15 Amp circuits onstage If you have any questions concerning the technical information and inventory list please contact Technical Director, Stephen Jackson: stephen@masseytheatre.com or 604 517 5900 ext. 6116 6 P a g e