NTB-500A. Medium Speed Network Terminal Box. Supports dynamic measurement at medium-speed synchronous sampling!

Similar documents
LAUREL ELECTRONICS, INC.

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

AI-1204Z-PCI. Features. 10MSPS, 12-bit Analog Input Board for PCI AI-1204Z-PCI 1. Ver.1.04

Product Information. EIB 700 Series External Interface Box

SCALE & WEIGHT DISPLAYS

263 Series LED Bargraph Indicator and Controllers

Scanning System S-2100

Electronic MICROSTAT-T Temperature controller with digital indication for use with resistance thermometers and thermocouples Series 8650

PROGRAMMABLE DC SOURCE VIEW RECORDERS Programmable DC Source FEATURES

Ethernet to VGA over IP Converter

Process Transmitter RMA 422

MT32 Telemetry Multi channel telemetry system for rotating application

DT3162. Ideal Applications Machine Vision Medical Imaging/Diagnostics Scientific Imaging

FX-4AD-TC SPECIAL FUNCTION BLOCK USER'S GUIDE

Hybrid Chart Recorder 250 mm (10")

Portable USB Potentiostat Low-Current Portable USB Potentiostat Extended Voltage USB Potentiostat

LX3V-4AD User manual Website: Technical Support: Skype: Phone: QQ Group: Technical forum:

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

IMPAC Infrared Thermometers

Chromalog T. Technical Information. Paper recorder Mulit-channel strip chart recorder with digital measured value display

RK-2 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD. Main characteristics

REMOTE I/O R30 SERIES. PC CONFIGURATOR SOFTWARE Model: R30CFG Ver Users Manual

Panel cutout required: 1.772" x 3.622" (45mm x 92mm) 1.76" (45mm) 2.45" (62mm) 3.20" (81mm) 3.60" (91mm) 0.59" (15mm) Special Features

WaveDriver 20 Potentiostat/Galvanostat System

Progressive Scan CCD Color Camera KP-FD30M. Specifications ( Revision.1 )

DCP100 Digital Control Programmer Specifications

Detect Color and Shape for various inspection

Instruction Manual. Universal Flow Controller Model 261 / 261-EC-01

Analog Input Module HART Ex n Inputs, 8 Channels Series 9461/15

MSO-28 Oscilloscope, Logic Analyzer, Spectrum Analyzer

Electrical and Electronic Laboratory Faculty of Engineering Chulalongkorn University. Cathode-Ray Oscilloscope (CRO)

Quick Start. RSHS1000 Series Handheld Digital Oscilloscope

Process transmitter RMA422

Analog Arts SA985 SA975 SA935 SA915 Product Specifications [1]

F250. Advanced algorithm enables ultra high speed and maximum flexibility. High-performance Vision Sensor. Features

Solid-State Digital Timer

PT-LW330 S P E C F I L E. LCD Projectors. As of April Specifications and appearance are subject to change without notice. 1/9.

FX-2DA SPECIAL FUNCTION BLOCK USER'S GUIDE

Analog Input Module HART Ex i / I.S. Inputs, 8 Channels Type 9461/

The measurements are stored in non-volatile memory, which retains data even when the power down.

EVENT INPUT/OUTPUT MODULE [PUME]

UDC100 Universal Digital Controller. Specification. Overview. Features. Features, continued /99 Page 1 of 4

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD SPECIAL FUNCTION BLOCK USER S GUIDE

Signal Conditioners. Highlights. Battery powered. Line powered. Multi-purpose. Modular-style. Multi-channel. Charge & impedance converters

INTRODUCTION TERMINAL LAYOUTS FX2N-4AD-TC SPECIAL FUNCTION BLOCK USER S GUIDE

PT-TX400 S P E C F I L E. LCD Projectors. As of December Specifications and appearance are subject to change without notice.

General Specifications

MX1609 T. Data sheet. Thermocouple amplifier Type T. Special features. Block diagram. B en

Assembly. Front view. LEDs. Parametrization interface. Power Bus

Micro-DCI 53ML5100 Manual Loader

IS 140 IGA 140 IS 140-PB IGA 140-PB IS 140-PN IGA 140-PN IS 140-ET IGA 140-ET

R1MS-GH3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL THERMOCOUPLE & DC INPUT MODULE MODEL. (8 points; isolated)

JD725A Cable and Antenna Analyzer - Dual Port

P-2 Installing the monitor (continued) Carry out as necessary

UNIVERSAL DIGITAL METER DC Volts and Amps AC RMS Volts and Amps Thermocouples and RTDs Process Signals Strain Gauge and Load Cell

Ocean Sensor Systems, Inc. Wave Staff III, OSSI With 0-5V & RS232 Output and A Self Grounding Coaxial Staff

PT-TW340 S P E C F I L E. LCD Projectors. As of May Specifications and appearance are subject to change without notice. 1/8.

PT-LB300 S P E C F I L E. LCD Projectors. As of April Specifications and appearance are subject to change without notice. 1/8.

B. The specified product shall be manufactured by a firm whose quality system is in compliance with the I.S./ISO 9001/EN 29001, QUALITY SYSTEM.

MBUS 10 RS232 TO MBUS LEVEL CONVERTER

AI-1616L-LPE. Features. High-precision Analog input board (Low Profile size) for PCI Express AI-1616L-LPE 1. Ver.1.02 Ver.1.01

AI-1664LAX-USB. Features. 100KSPS 16-bit Analog Input Unit for USB AI-1664LAX-USB 1. Ver.1.01

Analog Arts SA985 SA975 SA935 SA915 Product Specifications

PicoScope 4000 Automotive PC Oscilloscopes

In-process inspection: Inspector technology and concept

Product Number : LB303 Product Name : As of October Specifications and appearance are subject to change without notice.

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

Accessories. Servo Motors. Servo Motors B-47. Accessories

Digital Storage Oscilloscopes 2550 Series

Operating instructions Electronic preset counter Type series 717

Part 2. LV5333 LV5381 LV5382 LV7390 LV7770 LV7330 LV5838 LT4610 LT4600 LT4446 LT4100 LT4110 Accessories

PT-LB382 S P E C F I L E. LCD Projectors. As of July Specifications and appearance are subject to change without notice. 1/9.

Weekly Timer. Mounting track 50 cm (1.64 ft) length PFP-50N 1 m (3.28 ft) length PFP-100N

PRODUCT NO.: PT-L735 PRODUCT NAME: Ultra Portable LCD Projector

PRODUCT NO.: PT-L735NT PRODUCT NAME: Ultra Portable Wireless LCD Projector

Kuhnke Technical Data. Contact Details

ZN-PD. Smallest Air Particle Sensor in the Industry for In-line Measurement. Air Particle Sensor. Features

1/3 INCH COLOR HIGH RESO. CAMERA

Analog Storage Oscilloscope TS-81000/ Newly developed CCD(Charge-coupled device) scan converter tube

LOW-COST, 3 1/2 DIGIT DC VOLTMETERS MODEL 201A & 201AN OPTION 201AN-AC / 301AN

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

EMS DATA ACQUISITION AND MANAGEMENT (LVDAM-EMS) MODEL 9062-C

02/11/2015

BL67 electronic module 2 analog inputs for thermoelements BL67-2AI-TC

Slot-type Photomicrosensor with connector or pre-wired models (Non-modulated) *1. configuration. Dark-ON/Light-ON

Model Number Structure

Technical data. General specifications. Indicators/operating means

ABS ST700 Compact Type Series

R3267/3273 Spectrum Analyzers

Multifunction devices

Ordering Information. Absolute 60-mm-dia. Rotary Encoder E6F-A. High Accuracy and Durability for Automatic Equipment.

Vector Network Analyzer TTR503A/TTR506A USB Vector Network Analyzer Preliminary Datasheet. Subject to change.

Intelligent Pendulum Hardness Tester BEVS 1306 User Manual

PT-LB385 S P E C F I L E. LCD Projectors. As of December Specifications and appearance are subject to change without notice.

Oscilloscope Guide Tektronix TDS3034B & TDS3052B

multi-function meters

STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Product Number : LW373 Product Name : As of October Specifications and appearance are subject to change without notice.

General Specifications

Transcription:

Medium Speed Network Terminal Box Supports dynamic measurement at medium-speed synchronous sampling!

Decentralized arrangement and synchronous sampling of all channels. Medium Speed Network Terminal Box Features Synchronous measurement of all channels at a max of 1 k Hz Up to 8 channels per unit ( channels when 8 units are synchronized) Decentralized arrangement with one wire Controlled by DCS-100A (Dynamic Data Acquisition Software) Voltage/Thermocouple Unit NTB-51A Maximum Voltage: 50 V Thermocouples: K and T Frequency Response Voltage: 100 Hz Thermocouple: 10 Hz Isolated among channels Strain Unit NTB-50B Large strain measurement of 300 k m/m Frequency response of 100 Hz 24-bit A/D converter (Resolution: 0.1 m/m) Built-in bridge circuits TEDS-compatible 1

Applications of Repetitive loading test for concrete beams, etc. Vibration exciter NTB Verifying structure s durability Load cell Large strain of 300 k m/m measurement Measurement is possible for a wide range of input, up to near plastic domain of composite materials. Strain gages Control board PC NTB Web camera Power supply Stress measurement for construction machinery including cranes Simplified measurement on-site Deflection (Strain, displacement) of each part of the construction machinery is measured on-site. Synchronous acquisition of all channels data Different from scanning mode, sampling mode makes data acquisition of all channels perfectly synchronized and therefore no time lags among channels. Strain gages NTB Power supply PC Field observation of bridges, etc. Large-scale structure test Strain and displacement of each part of the bridge are measured while vehicles are passing. Sensor NTB Decentralized arrangement with one cable Connected every two s with one cable, the decentralized arrangement is available. Up to channels are connected within 100 m from the PC to the last. Power supply PC 2

Configuration Diagrams One DC power cable P-76 (Provided) or AC adapter SA-10A-EDS Sync communication cable for N-119 (1 m) USB/CAN converter 1.4 m LEAF LIGHT HS V2 Strain Gages Strain-gage Transducers NTB-50B Voltage Thermocouples NTB-51A Terminal resistor CANTERM120 Dynamic Data Acquisition Software DCS-100A (Provided) Docked 4 s DC power cable P-76 (Provided) or AC adapter SA-10A-EDS Sync communication cable for N-119 (1 m) USB/CAN converter 1.4 m LEAF LIGHT HS V2 Strain Gages Strain-gage Transducers NTB-50B Voltage Thermocouples NTB-51A Terminal resistor CANTERM120 Dynamic Data Acquisition Software DCS-100A (Provided) Connection of up to 4 s for 32 channels Decentralized Arrangement Sync Y cable for N-120 (0.1 m) USB/CAN converter 1.4 m LEAF LIGHT HS V2 Sync communication cable for N-119 (1 m) Terminal resistor CANTERM120 Dynamic Data Acquisition Software DCS-100A (Provided) Sync communication cable for N-119 (1 m) In addition, every requires a DC power cable or an AC adapter. Connection of up to 8 s for channels 3

Specifications of the Medium Speed Network Terminal Box Measuring Targets and Measuring Units Measuring units Voltage/ Strain Unit Thermocouple Measuring targets NTB-50B Unit NTB-51A Strain Gages Quater-bridge 120 2-wire system 3-wire system Half-bridge Active-active system 120 to 1000 Strain-gage Transducers Channels Synchronous Operations Sampling Frequencies Sampling Frequencies 1 k Hz 500 Hz 200 Hz 100 Hz 50 Hz 20 to 1 Hz Voltage Thermocouples Cable Length TEDS Interfaces Full-bridge 120 to 1000 8 16 40 Full bridge 10.0000 V 50.000 V K T Max. 8 channels/unit Measuring units (4 channels/unit) A Mixed combination of 2 is possible. Max. 8 units for channels 1, 2, 5, 10, 20, 50, 100, 200, 500, and 1k Hz (Synchronous sampling of all channels) Maximum measuring channels Cable length 20 m Cable length 80 m Cable length 100 m 4 8 20 40 4 8 20 40 Total extended cable length, max. 100 m Excluding when the sampling frequency is 1 khz.) Reads information from TEDS-installed sensors Channel name writing if the manufacturer s ID is Kyowa when NTB-50B is mounted. Bosch2.0 B active supported (ISO-11898-compliant high-speed CAN) Data Storage Measured data is saved on the PC. (No internal storage) Operating Temperature -10 to 50 C Operating Humidity 20 to 85%RH (No condensation) Power Supply 11 to 16 VDC Current Consumption (When using 12 VDC) Dimensions Measuring units On standby In measuring 2 NTB-50Bs installed 200 ma or less 230 ma or less 2 NTB-51As installed 250 ma or less 300 ma or less Weight EMC Directive 175 W 28.7 H 106.4 D mm (Excluding protrusions) Approx. 490 g EN61326-1 (Class A), (Within 30 m among units) Specifications of the Strain Unit NTB-50B Channels 4 Input Terminals One-touch terminal blocks Measuring Targets Strain gages Strain-gage transducers Applicable Gages Quater-bridge 120, 2-wire, 3-wire Half-bridge and Full-bridge 120 to 1000 Gage Factors 2.00 fixed Bridge Excitation 2 VDC 1% Check Functions Cable disconnection check TEDS Reads information from TEDS-installed sensors. Channel names writing if the manufacturer s ID is Kyowa Measuring Range, Resolution, and Range accuracy Measuring range Resolution Range accuracy 30 k m/m 0.1 m/m 300 k m/m 1 m/m Frequency Response DC to 100 Hz (Deviation +1 db, -3 db) Dimensions 152.2 W 6.1 H 45 D mm (Excluding protrusions) Weight Approx. 85 g Specifications of the Voltage/Thermocouple Unit NTB-51A Channels 4 Input Terminals Screw-soldering terminal blocks Measuring Targets Voltage, thermocouples (K, T) Check Functions Burnout check TEDS N/A Measuring Range, Resolution, and Accuracy Voltage Measurement Measuring range Resolution Range accuracy Input resistance 10 V 100 V 0.1% FS 1 M 50 V 1 mv Thermocouple Measurement 0.1% FS Accuracy Resolution Types Measuring External reference junction Ambient temp. (25 10) C Internal reference junction range K 200.0 to 1230.0 (0.5 % of (0.5% of reading + 2.0 ) C 0.1 T 200.0 to 400.0 reading+ 1.0 ) (Input pins at an equilibrium temp.) *Accuracy doesn't include the accuracy of the thermocouple. *Switching between internal and external reference junction compensator is possible. *Thermocouple s resistance: 1 k or less Frequency Response Voltage measurement: DC to 100 Hz (Deviation +1 db, -3 db) Thermocouple measurement: DC to 10 Hz (Deviation +0.5 db, -1 db) Isolation Between channels: 50 M or more (500 VDC) Dimensions 152.2 W 6.1 H 45 D mm (Excluding protrusions) Weight Approx. 95 g 4

Dimensions (Excluding protrusions) 175 28.7 106.4 Note: Appearance of the box when one NTB-50B and one NTB-51A are mounted. Standard Accessories Instruction manuals Simplified software Driver for a USB/CAN converter Dynamic Data Acquisition Software: DCS-100A * Wire connection seal DC power cable: P-76 Ground wire: P-72 Rubber feet x 4 Driver holder (With a mini screw driver) dummy panel: NTB500-DUMMY ** * For, the DCS-100A is provided. For -0, the DCS-100A is an option. ** The dummy panel is mounted on a vancant slot before shipping. DVD Caution Do not use NTB-100A series/201a together with. No relay box NTB-21A allows to be used for. No communication cables for NTB-100A series/201a (N-102 and the like) allows to be used for. No connection boards for the NTB-100A series/201a (CN-1A) allows to be used for No software for NTB-100A series/201a (NTB-10A) allows to be used for. Optional Accessories AC adapter: SA-10A-EDS Strain unit: NTB-50B Voltage/thermocouple unit: NTB-51A sync communication cable: N-119 (1 m) Note: For other length of cables, please contact us. sync Y cable: N-120 (0.1 m ) USB cable: N-38 (1 m) Docking board for 2 boxes of : CN-10A Docking board for 4 boxes of : CN-11A dummy panel: NTB500-DUMMY Data analysis software: DAS-200A USB/CAN converter: LEAF LIGHT HS V2 Power supply box for NTB: NTB-20A* Terminal resistor: CANTERM 120 DIN rail mounting plate: DRA-1 DIN rail (35 mm) N-119 N-120 NTB-20A *For details about NTB-20A, contact us, please. CANTERM 120 5

DCS-100A Dynamic Data Acquisition Software Standard accessory Specifications of DCS-100A for Operating Environment OS Windows Vista, 7, 8, 8.1, or 10, English/Japanese, 32, bits support CPU Core2Duo, 2 GHz or advanced Memory If 32-bit OS, 2 GB or more If -bit OS, 4 GB or more Interfaces Controllable Units Channel Conditions Sampling Frequencies Measuring Modes Manual Measurement Interval Measurement Analog Trigger Measurement End Triggers Delay TEDS Environment Settings Hardware Configulation 1 Hz to 1 khz, (Depends on the measuring channels and the cable length) Manual, manual (Data points preset), interval, and analog trigger Measurement is made from a press of the REC button to a press of the STOP button or to completion of recording to the preset data points. Measurement is made automatically at preset intervals from the preset starting time. (Interval of 5-step and 1-step are switchable.) Start and/or stop recording based on specified trigger conditions Settable Both start and end max. 262144 points/channel The delay differs with the measuring channels. Trigger Channels Any channel Trigger Level Sets physical quantities Trigger Slope Up, down Changing Stroke Static Measurement Repetition Acquisition Data Storage CAN, an optional USB/CAN converter is required. Setting Channel Conditions and Measuring Conditions Automatic Conversion Max. 8 for channels Measurement ON/OFF, mode, range, zero, LPF, calibration coefficient, offset, units, CH name, measuring range, decimal point, rated capacity, rated output, chk.val.(up), chk.val. (Down), (Selection of any display items is possible) Reads sensor's information and sets to channel condition automatically Changes the data before and after the stroke when using a displacement transducer. Every time the DCS-100A starts recording data, the DCS-100A additionally saves the movingaveraged measured data in a single CSV format file in manual and interval modes. In long-term data acquisition, a specified amount of data (Or time) is saved in KS2 file. Workable in manual mode (Data points preset). Measured data is saved in the PC in KS2 format. Setting of connected units, communications cable length, device name, measuring unit settings, and reading hardware configuration from the are possible. Data files are automaticlly transferred to the format of CSV, XLS, XLSX, or RPC upon completion of recording. Monitor Display and Data Reproduction Y-time Graphs Allows up to 16 channels of physical quantities to be graphed on Y axis with X axis for time. 1 to 10 graphs per window Y-time Graphs Allows all channels of physical quantities to be graphed on Y axis with X axis for time in the (All channels) same color curves. Y-time (DIV) Graphs X-Y Graphs Numeric Windows Graph Scale Display Color Dual-display Bar Graphs Circular Meters Bar Meters Over-input Indication Other Items of Data Reproduction Allows up to 16 channels of physical quantities to be graphed on Y axis with X axis for time. Zero point of each channel is moved freely to a desired position on a division of axis. Variables of desired 8 channels each for both X axis and Y axis are graphed in free combination. Shows numeric data of desired 1 or 16 channels or all channels. Capable of displaying auto-scale and full scale values on the Y-time graph (Y axis), X-Y graph (X, Y axes) and bar graph* (Y axis). The Y-time graph (Y axis) is able to be changed to 1 axis or 2 axes and CH (Channels). *Not for bar graph in data reproduction mode. Freely changeable graph by graph Titles and Labels Sets a desired title and labels for X and Y axes. Number of Simultaneously Displayed Windows Auxiliary lines Other Items of Monitor Display Comparative Data File Conversion Max., min., and average 32 numeric windows and 32 graph windows, in total, including reproduced data windows. Note: However that the number of windows may be restricted by the CPU speed and memory of the PC. Capable of displaying the desired auxiliary lines on the Y-time graphs (X axis and Y axis), X-Y Graphs (X axis and Y axis), and bar graphs (X axis and Y axis). (Up to 4 auxiliary lines each for both X axis and Y axis.) Capable of moving the numeric windows or graph windows onto the sub display. One bar graph has up to 32 channels and 1 to 4 graphs per window. Peak hold ON or OFF is possible. Variable of 1 desired channel per circular meter Variable of 1 desired channel in horizontal or vertical Capable of displaying the excessive channel values in red. Displays the comparative data (A previous KS2 format file) on the Y-time graphs, excluding the Y-time (All channels) graphs and Y-time (DIV) graphs, and X-Y graphs for comparing the monitor data. The size of the data file is maximum 10 MB. If the file size exceeds 10 MB, the DCS-100A displays the 10 MB-data from its head. Desired range of a channel is extracted and converted to the format of CSV, XLS, XLSX, or RPC. Capable of displaying the maximum value/ minimum value/average value within the window on the Y-time graphs when the number of channels is 1 or 2. Optional Units Registers up to 3 user-defined units. 6

Software for Reading/Displaying KS2 file data KS Viewer showing KS2* file data User-friendly View of Y-time graph data and file information http://www.kyowa-ei.com/eng/product/category/software/ksv-100a/index.html Sales Network China Japan Thailand Americas Region Americas Region KYOWA AMERICAS INC. TEL: +1-248-348-0348 E-mail: sales@kyowa-americas.com Web: http://www.kyowa-ei.us/ China KYOWA ELECTRONIC (SHANGHAI) TRADING CO., LTD. TEL: + E-mail: support-cn@d1.kyowa-ei.co.jp Web: http://www.kyowa-ei.cn/ Thailand KYOWA DENGYO (THAILAND) CO., LTD. TEL: + E-mail: sales-thailand@kyowa-ei.co.th Web: http://www.kyowa-ei.co.th/ Other Countries or Regions Please visit below URL. http://www.kyowa-ei.com/ KYOWA ELECTRONIC INSTRUMENTS CO., LTD. Cat.No.925c E3-5 Printed in Japan March 2017