Additional instructions Memograph M, RSG45 Advanced Data Manager

Similar documents
Application Note 11 - Totalization

ORM0022 EHPC210 Universal Controller Operation Manual Revision 1. EHPC210 Universal Controller. Operation Manual

DSIM-GI Installation Guide Revision P

Welcome. Explanation of Counter-, Integrator- and Operating time counter function of the LOGOSCREEN 500 cf. Dipl.-Ing. Manfred Schleicher

Wall-/Pipe-Mount Level Indicator

THE ASTRO LINE SERIES GEMINI 5200 INSTRUCTION MANUAL

Philips LightMaster. KNX Timeclock Installation and Operation Manual

Electronic Pulse Counter Combination device

SCS318. User Instructions. SCS318 comprising of SCS317 7 Day Wireless Programmable Room Thermostat and SSR303 Receiver

Revision History. SDG2000X Firmware Revision History and Update Instructions

ControlMaster CM15 Universal process indicator 1 /8 DIN

ControlMaster CM15 Universal process indicator 1 /8 DIN

User Guide Stand-Alone Metering for OptiPlant

Training Note TR-06RD. Schedules. Schedule types

User interface. Abbreviations / Meanings

application software

OPERATION MANUAL OF MULTIHEAD WEIGHER

Portable Data Recorder HMG Operating Manual (Original Manual)

application software

Operations. BCU Operator Display BMTW-SVU02C-EN

VOB - data over Video Overlay Box

Operating Instructions Liquistation CSF34

TRANSCENSION 6-CHANNEL DMX DIMMER PACK (order code: BOTE40) USER MANUAL

Vorne Industries. 87/719 Analog Input Module User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

COMPANY. MX 9000 Process Monitor. Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:MXMAN082416

MTL Software. Overview

Weschler AMT Software for the Enhanced Version Transformer Advantage

Chapter 23 Dimmer monitoring

icontrol Integrated Control System Operator s Card

MARCO CORNER, 19/ THIENE (VI) ITALIA

Short Manual. ZX2 Short Manual.doc Page 1 of 12

Digital differential Pressure switch Model DPS Instruction manual

Instructions for DataMark PDF Temperature Logger

Performing a Measurement/ Reading the Data

Revision 1.2d

SPG700 Multiformat Reference Sync Generator Release Notes

Quick Start Operating Instructions

CHOICECONNECT 100W ENDPOINT OVERVIEW

Troubleshooting CS800/LC900 Bikes

WELDING CONTROL UNIT: TE 450 USER MANUAL

Variwrap Controller Manual

ScreenMaster and ControlMaster Process recorders, controllers and indicator

Herzlich Willkommen Bienvenue Welcome. General Basics JUMO Screen Recorders. Manfred Schleicher

XTM72E & F Real-Time Clock Modules

Automatic Transfer Switch Control PLC Operator s Manual

Tebis application software

802DN Series A DeviceNet Limit Switch Parameter List

IO-Link Data Reference Guide: EZ-ARRAY Series

OPERATION AND MAINTENANCE

Modbus for SKF IMx and Analyst

Cat. No. N093-E1-1A. K3NR Frequency/Rate Meter

2G Video Wall Guide Just Add Power HD over IP Page1 2G VIDEO WALL GUIDE. Revised

IDS. Decoder Controller. Two-wire Decoder Control in an Advanced Industrial Package for the Largest Installations. Programming and Operations Manual

Registers type ILR7XX and ILR7XXT

Installation and User Guide 458/CTR8 8-Channel Ballast Controller Module

FACTORY AUTOMATION AS-INTERFACE MAINTENANCE AND TROUBLESHOOTING GUIDE

ED3. Digital Encoder Display Page 1 of 13. Description. Mechanical Drawing. Features

OWL micro+ WIRELESS ELECTRICITY MONITOR

Using different reference quantities in ArtemiS SUITE

MG-XV operating instruction. Measuring of norm signals, 4-8-digit. Panel instrument type MG-BV Construction instrument type MG-AV

Laser Beam Analyser Laser Diagnos c System. If you can measure it, you can control it!

PCM-16 Phase Synchronization Controller Operators Manual

Compressed Air Management Systems SIGMA AIR MANAGER Pressure flexibility Switching losses Control losses next.

2000 W, 2450 MHz Microwave Generator GMP 20K SM 56M230 FST 3 IR

127566, Россия, Москва, Алтуфьевское шоссе, дом 48, корпус 1 Телефон: +7 (499) (800) (бесплатно на территории России)

The Measurement Tools and What They Do

K-BUS Dimmer Module User manual-ver. 1

EAN-Performance and Latency

Programming instructions Software Version 5

Quick Setup Guide for IntelliAg Model NTA

Process transmitter RMA422

MPEG4 Digital Recording System THE VXM4 RANGE FROM A NAME YOU CAN RELY ON

HOME GUARD USER MANUAL

Measurements on GSM Base Stations According to Rec

MICROMASTER Encoder Module

REMOTE I/O R30 SERIES. PC CONFIGURATOR SOFTWARE Model: R30CFG Ver Users Manual

K3NX Process Meter OPERATION MANUAL

3200NT System 14. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

IQACO Changeover Switch

Service and Technical Support PLEASE CONTACT YOUR NEAREST DISTRIBUTOR If unknown then fax: 44 (0)

Configuring and Troubleshooting Set-Top Boxes

VLC-3 USER'S MANUAL. Light Program Controller. M rev. 04 K rev. 00 & ( ( 5, 352*5$0 1 : $ 2 ' 6(77,1*6 )81&7,216

51109 Köln St. Asaph, Denbigshire LL17OLJ

User Manual M1. Direct current / Direct voltage signals 0-20 ma, 4-20 ma, 0-10 VDC. Technical features:

FN:4181M5.DOC MC4181N SERIES MASTER CLOCKS MC4181N

Operating instructions Electronic preset counter Type series 717

Manual. Analog (U/I) Sendix M3661 / M3681. Sendix M3661R. Sendix M5861. Absolute multiturn encoder. Order code: 8.M36X1.XXXX.XX12

PowerMonic. FAQs [2/12]

AMIQ-K2 Program for Transferring Various-Format I/Q Data to AMIQ. Products: AMIQ, SMIQ

Installation / Set-up of Autoread Camera System to DS1000/DS1200 Inserters

DATA LOGGER MODEL L452 ENGLISH

Design and Use of a DTV Monitoring System consisting of DVQ(M), DVMD/DVRM and DVRG

Electronic Panel Meters DIGEM Preference Program Process control, automation & laboratory uses Class 0.01 to 1 Current, Voltage, Frequency,

Quick Setup Guide for IntelliAg Model CTA

Transmitter Interface Program

This document is a reference document that shows the menus in the 5500sc, 9610sc and 9611sc analyzers. There are 3 top-level menus:

OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE OPERATOR S GUIDE.

BUSES IN COMPUTER ARCHITECTURE

MT03A Electronic converter for flow rate transmitters

Agilent MOI for HDMI 1.4b Cable Assembly Test Revision Jul 2012

Transcription:

BA01337R/09/en/01.15 71302215 Firmware version ENU000A, V02.00.xx Products Solutions Services Additional instructions Memograph M, RSG45 Advanced Data Manager Option of wastewater + RSB (rain spillway basin) Additional functions of water/wastewater software

2 Advanced Data Manager

Advanced Data Manager Table of contents 1 General description of the function... 4 1.1 Alarm statistics............................. 5 2 Device configuration, application setup 6 2.1 General programming guidelines.............. 6 2.2 Advanced Setup - Application - Wastewater.... 6 2.3 Advanced setup - Application - Signal analysis (alarm statistics)............................ 7 2.4 Example: Recording of reservoir and overflow events at the rain spillway basin............... 9 2.5 Use during operation...................... 10 3 Error messages and troubleshooting. 11 4 Technical data.................... 11 3

General description of the function Advanced Data Manager 1 General description of the function This manual constitutes an additional description for a special software option. These additional instructions are not intended as a substitute for the Operating Instructions! Detailed information is provided in the Operating Instructions and the other documentation. Available for all device versions via: Internet: www.endress.com/deviceviewer Smart phone/tablet: Endress+Hauser Operations App The following functions are available in addition to the telealarm software functions: Recording the highest and lowest values for the analog channels The highest and lowest values of the analog channels are recorded based on x-minute average values (x is configurable: "From the instantaneous values", "From x-min. average values", "From x-hr. average values"). If "From the instantaneous values" is selected, a normal analysis (from the 100 ms values) is generated. 24h 15min 15min 15min 15min 15min Average value Average value Average value Average value Average value Minimum and maximum value from all 15min. average values Fig. 1: Recording the highest and lowest values over one day (x = 15 min.) Recording the floating highest and lowest values for quantities The flow rate from the last hour is recorded every minute for each quantity channel and the daily, weekly, monthly and yearly highest/lowest value determined based on this. The time of the highest/lowest value is also determined and stored. An exact load profile can be created from these values and thus abnormal daily situations can be recorded. Day changeover (synchron. time) = Previous value number of pulses before 1h + number of new pulses e.g. 200-5+1=196; 196-12 +8=192 the calculation only starts after the 1st hour 24h 1st hour 2nd hour Number of pulses (example) 5 12 1 0 22 1 8 3 5 3 5 1 hour 1 hour 1 hour 200 196 192 195 496 479 481 478 385 1 hour The highest and lowest values are determined from all minute values (-> min. = 192; max. = 496) Fig. 2: Recording the floating highest and lowest values for quantities 4

Advanced Data Manager General description of the function Infiltration water analysis To determine the infiltration water, the device calculates the quantity in a configurable timeframe. Infiltration water is the term used for water that does not really belong in a wastewater channel and does not have to be treated in a sewage treatment plant. A timeframe can be configured in Setup (e.g. from 03:00 to 04:00), during which an additional recording of the quantity takes place to determine the infiltration water, i.e. only the quantity that occurs during this timeframe is determined. This quantity is also displayed in daily, weekly, monthly and yearly analyses. The device can analyze the infiltration water for a maximum of 3 channels. Monitoring of rain spillway basins (RSB) All the relevant values for the reservoir and overflow are determined and saved in the event log for the rain spillway basins (RSB). The reservoir period is the length of time the water level in the basin is higher than the minimum water level. The set point violation (including date, time, duration, highest value, quantity) is recorded in an event message for upper analog set points (e.g. for overflow or reservoir). Alarm statistics are created for the basin overflow frequency. 1.1 Alarm statistics The following data are determined through the signal analysis cycles: How often was the set point violated (frequency)? Alternatively, the number of days during the analysis period on which at least one set point violation occurred can be recorded (e.g. required for reservoir frequency of the rain spillway basin). How long was the set point violated in total (in operating hours format 0000h00:00)? The alarm statistics are generated for every active signal analysis. The alarm statistics function is switched off as standard. The alarm statistics function must be activated for monitoring of the rain spillway basins (RSB). See the next section for description. Alarm statistics are not generated for externally controlled signal analysis for the time the analysis is not active. The alarm statistics are only generated for "analog" set points (upper, lower and gradient). No statistics are generated for "set points at counter". To determine the frequency, the system only reacts to the moment the set point is exceeded. If the set point is already violated at the time the analysis is started, the frequency value is NOT increased. The setting in the "Group days" parameter determines whether the number of set point violations or the days with a set point violation are counted. Example: Set point constantly violated from 08:59:50 to 09:01:10, analysis cycle 1 minute: Time span Frequency Duration 08:59:00 08:59:59 1 10 s 09:00:00 09:00:59 0 60 s 09:01:00 09:01:59 0 10 s 5

Device configuration, application setup Advanced Data Manager 2 Device configuration, application setup 2.1 General programming guidelines 1. First install and configure the device as described in Sections 1 to 9 of the Operating Instructions. Observe all the safety instructions! 2. Make the additional settings needed for wastewater application (see the next section). 3. Make the additional settings needed for the telealarm (see the additional description). 4. Configure the display, i.e. group the values for displaying and select the display mode. See from Section 10 of the Operating Instructions. 2.2 Advanced Setup - Application - Wastewater Settings for using the device in the wastewater sector. Depending on the selected function, the device's user interface is adapted, so that each time only parameters that are required have to be checked/set. Fig. 3: Application - Wastewater "Application - Wastewater" menu items Highest and lowest value Floating min/max 1 Floating min/max 2 Floating min/max 3 Configurable parameters (factory settings are highlighted in bold) The highest and lowest values of the analog channels are determined from the current values or from the ¼-hourly average values. Note: The highest and lowest values are determined for all the active analog channels. Signal analysis must be reset manually ("Advanced Setup -> Application -> Signal analysis -> Reset to zero") following a change in this menu so that the highest and lowest values are correctly generated. Picklist: From the instantaneous values, From x min. average values, From x hr. average values To determine the highest and lowest values for quantities, the quantity of the last 60 minutes is recorded every minute. An exact load profile can be created from these values and thus abnormal daily situations can be recorded. Select the channel for which the floating min/max value should be determined. Picklist: Switched off, Analog input x, Digital input x, Maths x Note: Totalization must be active for an analog channel. The function must be configured to pulse counter for a digital channel. For maths channels, the result must be a counter or integrated. Direct access code 500000/000 500001/000 500002/000 500003/000 6

Advanced Data Manager Device configuration, application setup "Application - Wastewater" menu items Configurable parameters (factory settings are highlighted in bold) Direct access code Infiltration water 1 Infiltration water 2 Infiltration water 3 Start infiltration water End infiltration water RSB 1 RSB 2 RSB 3 RSB 4 To determine the infiltration water, the device calculates the quantity in a configurable timeframe. Infiltration water is the term used for water that does not really belong in a wastewater channel and does not have to be treated in a sewage treatment plant. Select the channel for which the infiltration water should be determined. Picklist: Switched off, Analog input x, Digital input x, Maths x Note: Totalization must be active for an analog channel. The function must be configured to pulse counter, counter or quantity from time for a digital channel. For maths channels, the result must be a counter or integrated. Starting time for recording the volumes for determining infiltration water. Input: HH:MM; factory setting: 00:00 End time for recording the volumes for determining infiltration water. Input: HH:MM; factory setting: 00:00 All the relevant values for the reservoir and overflow are determined and saved in the event log for the rain spillway basins (RSB). Here, select the set point which causes reservoir or overflow to begin if the value is exceeded, and causes reservoir or overflow to end when the value is undershot. Picklist: Switched off, Set point x 500004/000 500005/000 500006/000 500007/000 500008/000 500009/000 500010/000 500011/000 500012/000 2.3 Advanced setup - Application - Signal analysis (alarm statistics) Setup in order to get signal analysis for a preset time range/cycle as well as the function to manually reset the signal analysis. Only settings relevant for the wastewater option are described here. For all the other signal analysis functions, see the Operating Instructions. Depending on the selected function, the device's user interface is adapted, so that each time only parameters that are required have to be checked/set. Fig. 4: Application - Signal analysis - Alarm statistics 7

Device configuration, application setup Advanced Data Manager "System - Signal analysis" menu items Configurable parameters (factory settings are highlighted in bold) Direct access code Alarm statistics The following data can be determined by means of the signal analysis cycles (e.g. daily analysis): How often was the set point violated (frequency) How long was the set point violated (duration in operating hours format 0000h00:00) Picklist: no, yes 440006/000 Group days (only if "Alarm statistics" - "Yes") The alarm statistics are generated for every active signal analysis. Alarm statistics are not generated for externally controlled signal analysis for the time the analysis is not active. The alarm statistics are only generated for "analog" set points (upper, lower and gradient). No statistics are generated for "set points at counter". Set points can be set for the data of the alarm statistics. These set points can monitor the frequency or duration of set point violation for the analysis duration. Configuration under "Advanced setup -> Application -> Set points -> Set point x -> Channel or type" (see Operating Instructions). "Yes" should be selected here for the "rain spillway basins RSB" option. Set up how often the weekly, monthly or yearly analysis is to be calculated. "No": Each individual set point violation is counted. "Yes": The number of days during the analysis period on which at least one set point violation occurred is recorded (e.g. required for reservoir frequency of the rain spillway basin even if this already started on the previous day). Picklist: no, yes "Yes" should be selected here for the "rain spillway basins RSB" option. 440008/000 The modified settings only take effect once the display mode (measured value display) is resumed after configuration. Exit the operating menus by repeatedly pressing the "Back" option. Until this time, the device still works with the previous data. 8

Advanced Data Manager Device configuration, application setup 2.4 Example: Recording of reservoir and overflow events at the rain spillway basin 2.4.1 Step-by-step: reservoir 1. Set the upper set point (e.g. set point 1) to the level (e.g. universal input 1) under "Setup -> Advanced setup -> Application -> Set points -> Set point 1". The reservoir event begins when this set point is exceeded. 2. Set "RSB 1" to this set point under "Setup -> Advanced setup -> Application -> Wastewater -> RSB 1: set point 1" 2.4.2 Step-by-step: overflow 1. Set the linearization table to the overflow level (e.g. universal input 2) under "Setup -> Advanced setup -> Inputs -> Universal inputs -> Universal input 2 -> Linearization -> Points" 2. Activate totalization for the overflow amount of the corresponding channel under "Setup -> Advanced setup -> Inputs -> Universal inputs -> Universal input 2 -> Totalization" 3. Set the upper set point (e.g. set point 2) to the overflow amount of the corresponding channel under "Setup -> Advanced setup -> Application -> Set points -> Set point 2". The overflow event begins when this set point is exceeded. 4. Set "RSB 2" to this set point under "Setup -> Advanced setup -> Application -> Wastewater -> RSB 2: set point 2" 2.4.3 Recording the duration and frequency Activate monthly, annual and alarm statistics under "Setup -> Advanced setup -> Application -> Signal analysis" 9

Device configuration, application setup Advanced Data Manager 2.5 Use during operation 2.5.1 The event log During operation, the event log can be called up by pressing softkey 1 (user-configurable) or via "Main menu -> Diagnostics -> Event log": Fig. 5: Event log All the set point violations for the reservoir and overflow of the rain spillway basin (RSB) can be viewed here. For this purpose, select the entry in question in the event log and press softkey 3 "Details". To return to instantaneous value display, press softkey 1 "ESC". 2.5.2 Signal analysis During operation, signal analysis can be called up via "Main menu -> Operation -> Signal analysis": Fig. 6: Operation - Signal analysis In addition to the normal quantities, the highest and lowest values (incl. dimension) can be displayed here for the channels, for which the highest and lowest values are determined. The highest and lowest values are displayed in the completed analyses. The infiltration water is displayed both in the current intermediate analysis and in the completed analyses. To return to instantaneous value display, press softkey 1 "ESC". 10

Advanced Data Manager Error messages and troubleshooting 2.5.3 Alarm statistics in signal analysis During operation, signal analysis with alarm statistics can be called up via "Main menu -> Operation -> Signal analysis": Fig. 7: Signal analysis with alarm statistics The alarm statistics (frequency/duration) are displayed here in addition to the signal analysis selected (see Operating Instructions). To return to instantaneous value display, press softkey 1 "ESC". The alarm statistics are reset via normal signal analysis "Advanced setup -> Application -> Signal analysis -> Reset to zero". The data of the alarm statistics can also be displayed, printed out and exported with the Field Data Manager (FDM) PC software supplied. 3 Error messages and troubleshooting Plain text on the screen of your device will keep you informed in the event of a fault or incorrect input. The error code is displayed in the Display mode (measured value display) on the top right of the screen. Version with navigator and front interfaces: In addition, a red LED indicates an error or flashes on a warning or if maintenance is required. Refer to Section 12 "Diagnostics and troubleshooting" of the Operating Instructions for detailed error messages and solutions to problems. 4 Technical data The technical data of the Operating Instructions apply for this device option. 11

www.addresses.endress.com