Updated 151120 TableTop series Hardware version 6
We keep expanding Hardware 6 Introduced 2011 Hardware 5 Introduced 2006 Hardware 4 Introduced 2003 32KByte 128KByte 256KByte
What's new? Feature Hardware 5 Hardware 6 Built-in 455 KHz receiver for B&O Yes No External 455 KHz receiver required for B&O No Yes Reading IR receivers buttons No Yes Control of IR receivers LEDs No Yes Number of RS232 comports 1 2 Programmable RS232 signals/port No Yes Ready for B&O Masterlink Gateway No Yes Number of low-power IR outputs 1 2 Programmable IR low-power outputs No Yes Programmable IR high-power output No Yes B&O 455 KHz transmitter software soft/hardware Filters BEO4/BEO5 long-codes No Yes RS485 Yes No X10 port Yes No Flash program size 128KB 256KB Volatile memory (SRAM) 4KB 8KB Non-volatile memory (EEPROM) 4KB 4KB Multi-purpose Timers 3 5
Hardware 6.1 includes a new 3 volt IR LED with 30% more light adding 30% to the original range. When controlling B&O systems, this increases the operation range to beyond BEO4 level. 850 NM 940 NM Hardware Version 5.0 Hardware Version 6.1
Circuit boards dimensions RED LED GREEN LED 1 GREEN LED 2 940 nm 850 nm 940 nm 16 mm 59 mm 93 mm
Programmable jack-connector 1 1 1 1 IR LOW-POWER OUTPUT 2 2 2 2 2 IR BUTTONS/LED FACTORY DEFAULT 3 3 3 3 IR RECEIVER LED 1 Button 1 Button 2 Button 3 v v Button 4 LED 2
TT-IR-8087030 IR RECEIVER 1 2 3 4 5 3 4 5 A B C NOTE: The IR receiver (alu case) and the cable, are delivered to us separately. Unfortunately the cable wires, often vary in colors. Below we have listed the typical combinations. If the cable you have received, is not included below, then please contact LinTronic, or get some local help to measure how the cable is wired. Cable type 1 Cable type 2 Pin Letter Desc Color 3 B IR data Green 4 C 5 Volt Yellow 5 A Ground Brown Pin Letter Desc Color 3 B IR data Red 4 C 5 Volt Black 5 A Ground unisolated
Programmable jack-connector IR AND BUTTONS CONTROL If you want to make use of the buttons or the LEDs of your external B&O receiver, the jumpers must be in this position (factory set). You wire two 3.5 mm jack connectors as show below: - one for the buttons/leds (2-wires, pin 1-2) - one for the infrared signals (3-wires, pin 3-5) For the buttons/leds you may optionally use a stereo connector or a mono-connector. It is easier to verify that connectors are correctly inserted if you use a mono-connector for the buttons. TT-IR-8087030 5 4 3 2 1 3 = IR signal 4 = 5 volt 5 = Ground Infrared/power Buttons/LEDs Jack connector seen from solderside 5 3 4 4 3 1 - CLOCK 2 - DATA 2 1 2 1 Not used Mono Stereo 1 5 Jack connector seen from solderside 2 Not used
Programmable jack-connector BUTTONS CONTROL ONLY If you only want to control the TT455-RT-238 by the buttons on the front of the external receiver, you will still need to install both connectors. The data wire carrying the IR signal can be leaved out. TT-IR-8087030 5 4 3 2 1 3 = IR signal 4 = 5 volt 5 = Ground Infrared/power Buttons/LEDs Jack connector seen from solderside 5 3 4 4 3 1 - CLOCK 2 - DATA 2 1 Mono 1 5 Jack connector seen from solderside Not used 2
IR receiver USING ONE RECIVER FOR TWO SYSTEMS B&O 8087030 1 2 3 4 5 3 - B IR SIGNAL 4 - C 5 Volt 5 - A Ground Jack connector seen from solderside A B C TO TT455-RT-238 OR BEOSYSTEM A C A B IR/DATA Ground Do not connect center, 5 volt A B TO TT455-RT-238 OR BEOSYSTEM B Jack connector seen from solderside A B
IR receivers & transmitters IR TRANSMITTER FRONT B&O 455 KHz oscillator IR LOW-POWER OUTPUT 2 1 2 3 1 2 3 IR RECEIVER IR LOW-POWER 2 IR LOW-POWER 1 3-CHANNEL SOFTWARE PROGRAMMABLE IR DISTRIBUTOR LEVEL IR FRONT BOOSTER 50% or 100% IR TRANSMITTER IR LOW-POWER 1 IR LOW-POWER 2
External low-power IR output TT-IR-ET03 TableTop Transmitter or Converter Input Output Communication Output Power 2 pcs low-power IR outputs
RS232 comports 1 2 Digital Inputs 5 volt pulled-up. 100K Digital Outputs active low, 5 volt pulled-up 1 2 Gnd Gnd RS232 PORT 2 Gnd Rx (in) Tx (out) 5 4 3 2 1 9 8 7 6 Programmable RS232 PORT 1 Gnd Rx (in) Tx (out) SOFTWARE PROGRAMMABLE RS232 DISTRIBUTOR RS232 COMPORT 2 RS232 COMPORT 1
Digital Inputs 5 4 3 2 1 9 8 7 6 Digital Inputs 1 or 4 100K 5 volt 5 The digital Input is internally pulled up by a 100 Kohm resistor. In order to activate the input, the input pin 1, must be grounded. The TT455-RT-238 s digital inputs can be configured to react to both ON and OFF. This allows you to activate one action when the input is activated and another action when the input is released. For example: 1) Connect a motion PIR detector and let the TT455-RT-238 control your light system by RS232 when the PIR is activated or deactivated. 2) Used by some dealers: An outside motion sensor, turn on the TV and play a DVD when people pass by the window.
Digital Outputs The digital outputs are programmable in the in/out tab, in Memory Map of the Configurator. Outputs can work as: Active 12 volt (default) or Active Ground or Ative Ground with 5 volt pull-up
Digital Outputs, Active 12 volt The digital outputs are designed for direct control of 12 V relays. This can be used to control lamps, curtains, motors, etc. We offer Schrack relays and DIN/WALL mount housing. 5 4 3 2 1 9 8 7 6 12 volt Active 12 volt 3R3 Pin 6 = digital output 1 Pin 9 = digital output 2 Pin 5 = Ground A2 A1 21 24 COM NO 11 14 Can be screwed to the wall or mounted in a DIN rail. SCHRACH A2 22 COIL NC A1 12 Side view Front view
Digital Output 1, Active 12 volt 5 4 3 2 1 9 8 7 6 21 24 COM NO 11 14 12 volt SCHRACH 3R3 Pin 6 Digital output 1 A2 22 COIL A1 12 Pin 5 = Ground NC Digital Output 2, Active 12 volt 5 4 3 2 1 9 8 7 6 21 24 COM NO 11 14 12 volt SCHRACH 3R3 Pin 9 Digital output 2 A2 22 COIL A1 12 Pin 5 = Ground NC
Digital Outputs, Active 12 volt Example on how the TT455-RT-238 may control a 115/230 vac lamp on/off. NOTE: In some countries - by law - only an electrician may install 115/230 vac. Run the fused phase (brown) to pin 11 (lamp 1) and pin 21 (lamp 2). Run the neutral/ground (can have different names) to lamp 1 and lamp 2. Run pin 14 (on/off output for lamp 1) to lamp 1. Run pin 24 (on/off output for lamp 2) to lamp 2. Run TT455-RT-238's digital output 1 (or 2) to A2 (coil) of the relay. Run TT455-RT-238's ground to A1 (coil) of the relay. The TT455-RT-238 is totally isolated from the 115/230 vac due to the relay. 115-230 vac 50/60 Hz (fused) 2 lamps 21 COM 11 TT455-RT-238 24 NO 14 12 volt SCHRACH 3R3 digital output 5 A2 COIL 22 12 NC Front view A1
Digital Outputs, Active Ground 5 volt Active ground 100K solder pad 3R3 6 or 9 5 The Digital Output is a Ground-active Open Collector. When the output is on the signal is grounded. An internal optional 5 volt pull-up resistor can be connected, by soldering a solder-pad for each output. The pull-up for digital output 1 is shown below with blue marking. The pull-up for digital output 2 is shown below with red marking. Updated 110725
Digital Outputs, Active Ground The below red marking shows where to solder, in order to insert the 5 volt pull-up resistor for the digital output 2. Simply solder the two pads together. OBSERVE Please consult with LinTronic before soldering. Updated 110725
>> > > > > RADIO LinTronic MULTIPLE CONTROL OPTIONS perfect for open and hidden installations RS232 comport 1 RS232 comport 2 Computer, Controller, PLC, B&O MasterLink gateway, RELAY 208 board,tt455-rt-238, light system,audio/video switcher, tv, screen,projector, etc. Computer, Controller, PLC, B&O MasterLink gateway, RELAY 208 board, TT455-RT-238, light system, audio/video switcher, tv, screen, projector, etc. 2 pcs. Digital inputs 2 pcs. Digital outputs 3-way low-power infrared emitter B&O receiver TV LIGHT SAT DVD CD 3-way long-range high-power wide-angle infrared booster VTAPE RECORD ATAPE 7 8 9 4 5 6 1 2 3 TEXT 0 MENU GO >> LIST EXIT STOP Updated 110725 BANG & OLUFSEN
>> > > > > RADIO LinTronic Selectable IR and RS232 ports Send commands to an optional port In this example - triggered by the BEO4 or BEO5 - we send out an RS232 command to a relay board in order to close the curtains, we send an RS232 command to lower the light levels and we send an infrared PLAY command the DVD player. RS232 comport 1 RS232 comport 2 2 pcs. Digital inputs 2 pcs. Digital outputs 3-way low-power infrared emitter B&O receiver TV LIGHT SAT DVD CD 3-way long-range high-power wide-angle infrared booster VTAPE RECORD ATAPE 7 8 9 4 5 6 1 2 3 TEXT 0 MENU GO >> LIST EXIT STOP Updated 110725 BANG & OLUFSEN
Selectable IR and RS232 ports Receive RS232 commands as trigger In this example we receive a customized RS232 command from a B&O Masterlink Gateway, then converts it to a command for the RELAY 208 board (curtains, lift, etc.) or your light system - and control multiple audio/video devices by infrared. RS232 comport 1 RS232 comport 2 2 pcs. Digital inputs 2 pcs. Digital outputs 3-way low-power infrared emitter B&O receiver 3-way long-range high-power wide-angle infrared booster Updated 110725
Cascading transparent RS232 ports Our products can be configured to pass-on RS232 commands. This allows your remote to control the computer/controller, the TT455-RT-238 (audio/video), the RELAY 208 (curtains, lift, etc.) and your light system. Simply control the TT455-RT-238 and let it control the rest - or send the commands straight through the TT455-RT-238 or the RELAY 208. It also allows your computer to control the TT455-RT-238 directly and the RELAY and the light system - through the TT455-RT-238/RELAY 208. Light system B&O receiver COM1 COM2 GND 12V G B A 2 1 C A R C A R C A R C A R 1 2 3 5 6 7 8 C A R C A R C A R C A R 1 2 3 4 RELAY 208 Updated 110725
Cascading transparent RS232 ports Perfect for B&O MasterLink Gateway Since the B&O MasterLink Gateway only holds one RS232 port, you can now expand the controls to include for example the TT455-RT-238 and/or the RELAY 208 and/or your light system, etc. etc. B&O MasterLink Gateway Light system B&O receiver COM1 COM2 GND 12V G B A 2 1 C A R C A R C A R C A R 1 2 3 5 6 7 8 C A R C A R C A R C A R 1 2 3 4 RELAY 208 Updated 110725
Control from your Iphone We offer you endless combinations The Iphone controls the B&O MasterLink Gateway, which controls the TT455-RT-238, which controls your audio/video by IR, and controls your curtains by relays and your light system by RS232 - even if your products are not supported by B&O MasterLink Gateway. B&O MasterLink Gateway Light system B&O receiver COM1 COM2 GND 12V G B A 2 1 C A R C A R C A R C A R 1 2 3 5 6 7 8 C A R C A R C A R C A R 1 2 3 4 RELAY 208 Updated 110725